Search NASA⌕ Search

SEARCH · Search NASA

Results for “THRESHOLD CURRENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Effects of arc current on the life in burner rig thermal cycling of plasma sprayed ZrOsub2-Ysub2Osub3

An analysis of thermal cycle life data for four sets of eight thermal barrier coated specimens representing arc currents (plasma gun power) of 525, 600, 800, or 950 amps is presented. The ZrO2-8Y2O3/NiCrAlY plasma spray coated Rene 41 rods were thermal cycled to 1040 C in a Mach 0.3-Jet A/air burner flame. The experimental results indicate the existance of a minimum or threshold power level which coating life expectancy is less than 500 cycles. Above the threshold power level, coating life expectancy more than doubles and increases with arc current.

Hendricks, R. C.↗

Investigating the Airspace Safety Threshold of the NAS

As self-separation systems are being developed for integration into the airspace, it is crucial to determine a standard that the systems must meet so that airspace safety does not degrade. To do this, the current level of safety of the NAS (National Airspace System) needs to be determined as a benchmark for comparison. This presentation is an overview of some of the ongoing work being done to evaluate the airspace as it is today. The research analyzes the distribution of encounter statistics of IFR-VFR (Instrument Flight Rules-Visual Flight Rules) traffic using unmodified historical flight data to account for mitigation effects present in the current NAS.

Airspace Encounters↗

A visual detection model for DCT coefficient quantization

The discrete cosine transform (DCT) is widely used in image compression and is part of the JPEG and MPEG compression standards. The degree of compression and the amount of distortion in the decompressed image are controlled by the quantization of the transform coefficients. The standards do not specify how the DCT coefficients should be quantized. One approach is to set the quantization level for each coefficient so that the quantization error is near the threshold of visibility. Results from previous work are combined to form the current best detection model for DCT coefficient quantization noise. This model predicts sensitivity as a function of display parameters, enabling quantization matrices to be designed for display situations varying in luminance, veiling light, and spatial frequency related conditions (pixel size, viewing distance, and aspect ratio). It also allows arbitrary color space directions for the representation of color. A model-based method of optimizing the quantization matrix for an individual image was developed. The model described above provides visual thresholds for each DCT frequency. These thresholds are adjusted within each block for visual light adaptation and contrast masking. For given quantization matrix, the DCT quantization errors are scaled by the adjusted thresholds to yield perceptual errors. These errors are pooled nonlinearly over the image to yield total perceptual error. With this model one may estimate the quantization matrix for a particular image that yields minimum bit rate for a given total perceptual error, or minimum perceptual error for a given bit rate. Custom matrices for a number of images show clear improvement over image-independent matrices. Custom matrices are compatible with the JPEG standard, which requires transmission of the quantization matrix.

Ahumada, Albert J., Jr.↗

Evaluation of an Impedance Threshold Device as a VIIP Countermeasure

Visual Impairment/Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs (Braslets) and lower body negative pressure (LBNP; Chibis) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure. The ITD works by providing up to 7 cm H2O (approximately 5 mmHg) resistance to inspiratory air flow, effectively turning the thorax into a vacuum pump upon each inhalation which lowers the intrathoracic pressure (ITP) and facilitates venous return to the heart. The ITD is FDA-approved and was developed to augment venous return to the central circulation and increase cardiac output during cardiopulmonary resuscitation (CPR) and in patients with hypotension. While the effect of ITD on CPR survival outcomes is controversial, the ITD's ability to lower ITP with a concomitant decrease in intracranial pressure (ICP) is well documented. A similar concept that creates negative ITP during exhalation (intrathoracic pressure regulator; ITPR) decreased ICP in 16 of 20 patients with elevated ICP in a hospital pilot study. ITP and central venous pressure (CVP) have been shown to decrease in microgravity however ITP drops more than CVP, indicating an increased transmural CVP. This could explain the paradoxical distention of jugular veins (JV) in microgravity despite lower absolute CVP and also suggests that JV transmural pressure is not dramatically elevated. Use of an ITD may lower JV pressure enough to remove or relieve cephalic venous congestion. During spaceflight experiments with Braslet thigh cuffs and modified (open-glottis) Mueller maneuvers, Braslets alone reduced cardiac preload but only reduced the internal JV (IJV) cross sectional area by 23%. The addition of Mueller maneuvers resulted in an IJV area reduction of 48%. This project will test if ITD essentially applies a Mueller maneuver with added negative ITP in every respiratory cycle, acting to: 1) reduce venous congestion in the neck and 2) potentially lower ICP. The expected mechanism of action is that in microgravity (or an analog) blood is relocated toward the heart from vasculature in the head and neck. Once validated, the ITD would be an exceptionally easy countermeasure to deploy and test on the ISS. Dosage could be altered though 1) duration of application and 2) inspiratory resistance set point. Effects could be additionally enhanced through co-application with other countermeasures such as thigh cuffs or LBNP.

Ebert, Douglas↗

Evaluation of an Impedance Threshold Device as a VIIP Countermeasure

Visual Impairment/Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs (Braslets) and lower body negative pressure (LBNP; Chibis) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure.

Ebert, D.↗

Evaluation of an Impedance Threshold Device as a VIIP Countermeasure

Visual Impairment/Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs and lower body negative pressure (LBNP) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure.

Ebert, Douglas↗

Net current measurements and secondary electron emission characteristics of the Voyager plasma science experiment and their impact on data interpretation

The Voyager Plasma Science (PLS) instrument is capable of returning integral (DC) current measurements, similar in some respects to measurements made with a Langmuir probe or a retarding potential analyzer, although there are significant differences. The integral measurements were made during a calibration sequence in the solar wind, during Cruise Science Maneuvers, and within the magnetospheres of Jupiter and Saturn by Voyager 1. After the failure of the PLS experiment following the Saturn encounter, that instrument was placed in the DC return mode returning possibly usable data from early 1981 through early 1985. The DC return measurements are difficult to interpret and are above threshold values only for relatively large fluxes; the determination of the measured current level is dependent on the operating temperature of the preamplifiers which further complicates the interpretation. Nevertheless, these measurements can be used to determine the efficiency of the suppressor grid at preventing the loss of secondary electrons off the collector plate. Some DC return measurements have been invaluable in aiding in the interpretation of some electron plasma measurements not previously understood. It is found that electron spectra can be significantly modified by the presence of second generation secondary electrons produced by either first generation secondaries or photoelectrons on the support ring of the negative high voltage modulator grid within the instrument housing.

Mcnutt, Ralph L., Jr.↗

MSL Telecom Automated Anomaly Detection

The Mars Science Laboratory (MSL) Telecom Operations Team at the Jet Propulsion Laboratory (JPL) has implemented a machine learning system in order to automate the anomaly detection process as a part of daily operations. Machine learning enables reliable detection of anomalies in Telecom-related telemetry and automated reporting of Telecom subsystem status, resulting in an 90% reduction in team workload and improved anomaly detection reliability. At present, machine learning methods are used to detect: 1. Anomalous long-term trends in telemetry data 2. Anomalous time-domain evolution of telemetry values Both types of anomalies pose their own unique challenges that are addressed in different ways. In the first case, long term trending of daily minima, maximum, and mean telemetry values in temperatures, currents, voltages, and radio frequency (RF) power levels is used in addition to hard threshold safety checks to look for changes in long-term equipment health and performance. Long-term trending methods allow for ordinary seasonal variations in these quantities caused by temperature changes over the course of the Martian year while allowing operators to determine whether current performance remains in line with historical values from previous years. Changes in long-term trends can provide important insights into the health and status of the rover's on-board systems as well as valuable early warning if subtle degradation begins to take hold. But while trending of daily statistics is valuable, it does not detect anomalies in the short-term time evolution of data over the course of minutes or hours during a day, and this task is handled with short-term shape analysis. Principal components analysis (PCA) has been found to provide robust detection of short-term anomalies, and several examples of the use of PCA to detect actual anomalous events will be provided here. In using PCA, we use both the percentage of explained variance and also a log likelihood test on the PCA expansion coefficients to flag telemetry data for human review. Previous work in the field of spacecraft anomaly detection includes [1] for MSL and [2] for some other JPL missions.

Mukai, Ryan↗

Evaluation of the Self Retrieval Augmented Generation Technique on Common Security Advisory Framework Data

This small experimental report evaluates a variation of Retrieval Augmented Generation (RAG), called Self-RAG. This method uses a generative language model that incorporates retrieved facts into its generation and is explicitly trained to be able to determine whether retrieved information is enough to answer the input query, with a user-defined threshold for confidence. We performed an experiment using data from the publicly available CISA Common Security Advisory Framework (CSAF) repository (https://github.com/cisagov/CSAF) as the database of facts to be used in retrieval. Qualitative results from the experiment demonstrate that the Self-RAG method has some ability to provide reasonable answers to queries that are in the dataset and will often ignore irrelevant information when asked outside of domain questions (e.g., general facts). In settings with deliberately confusing questions (the question is within domain, but asks about a fabricated advisory), it was able to refuse 40% of the time without further adjustments to the original framework. While this performance is not sufficient for current practical use, further improvements to data formatting, disambiguating results, and leveraging threshold values could improve performance significantly. However, evaluating this will require more extensive evaluations on larger datasets and potentially better models.

97 MATHEMATICS AND COMPUTING↗

Evaluation of an Impedance Threshold Device as a VIIP Countermeasure

Visual Impairment /Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs (Braslets) and lower body negative pressure (LBNP; Chibis) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure. The ITD works by providing up to 7 cm H2O (approximately 5 mmHg) resistance to inspiratory air flow, effectively turning the thorax into a vacuum pump upon each inhalation which lowers the intrathoracic pressure (ITP) and facilitates venous return to the heart. The ITD is FDA-approved and was developed to augment venous return to the central circulation and increase cardiac output during cardiopulmonary resuscitation (CPR) and in patients with hypotension. While the effect of ITD on CPR survival outcomes is controversial, the ITD's ability to lower ITP with a concomitant decrease in intracranial pressure (ICP) is well documented. A similar concept that creates negative ITP during exhalation (intrathoracic pressure regulator; ITPR) decreased ICP in 16 of 20 patients with elevated ICP in a hospital pilot study. ITP and central venous pressure (CVP) have been shown to decrease in microgravity however ITP drops more than CVP, indicating an increased transmural CVP. This could explain the paradoxical distention of jugular veins (JV) in microgravity despite lower absolute CVP and also suggests that JV transmural pressure is not dramatically elevated. Use of an ITD may lower JV pressure enough to remove or relieve cephalic venous congestion. During spaceflight experiments with Braslet thigh cuffs and modified (open-glottis) Mueller maneuvers, Braslets alone reduced cardiac preload but only reduced the internal JV (IJV) cross sectional area by 23%. The addition of Mueller maneuvers resulted in an IJV area reduction of 48%. This project will test if ITD essentially applies a Mueller maneuver with added negative ITP in every respiratory cycle, acting to: 1) reduce venous congestion in the neck and 2) potentially lower ICP. The expected mechanism of action is that in microgravity (or an analog) blood is relocated toward the heart from vasculature in the head and neck. Once validated, the ITD would be an exceptionally easy countermeasure to deploy and test on the ISS. Dosage could be altered though 1) duration of application and 2) inspiratory resistance set point. Effects could be additionally enhanced through co-application with other countermeasures such as thigh cuffs or LBNP.

Ebert, D.↗

Josephson dynamics in two-dimensional ring-shaped condensates

We investigate Josephson transport in a fully closed, two-dimensional superfluid circuit formed by a ring-shaped 87 Rb Bose-Einstein condensate that contains two optical barriers acting as movable weak links. Translating these barriers at controlled speeds imposes a steady bias current, enabling direct mapping of the current-chemical-potential (𝐼−Δ⁢𝜇) characteristics. For narrow junctions (𝑤 ≈ 1µ⁢m), the circuit exhibits a pronounced dc branch that terminates at a critical current 𝐼 𝑐 = 9⁢(1) × 10 3 s −1 ; above this threshold, the system switches to an ac, resistive regime. Classical-field simulations that include the moving barriers quantitatively reproduce both the nonlinear 𝐼−Δ⁢𝜇 curve and the measured 𝐼 𝑐 , validating the underlying microscopic picture. Analysis of the ensuing phase dynamics shows that dissipation is mediated by the nucleation and traversal of vortex-antivortex pairs through the junctions, while the bulk condensate remains globally phase locked—direct evidence of the ring's topological constraint enforcing quantized circulation. These results establish a cold-atom analog of a superconducting quantum interference device in which Josephson dynamics can be resolved at the single-vortex level, providing a versatile platform for atomtronic circuit elements, nonreciprocal Josephson devices, and on-chip Sagnac interferometers for multiaxis rotation sensing.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measuring the growth of Alfvén wave parametric decay instability using counter-propagating waves: Theory and simulations

The parametric decay instability (PDI) of Alfvén waves—where a pump Alfvén wave decays into a backward-propagating child Alfvén wave and a forward ion acoustic wave—is a fundamental nonlinear wave-wave interaction and holds significant implications for space and laboratory plasmas. However, to date there has been no direct experimental measurement of PDI. Here, we propose a novel and experimentally viable scheme to quantify the growth of Alfvén wave PDI on a linear device using a large pump Alfvén wave and a small counter-propagating seed Alfvén wave, with the seed-wave frequency tuned to match the backward Alfvén wave generated by standard PDI. Using hybrid simulations, we show that energy transfer from the pump to the seed reduces the latter's spatial damping. By comparing seed-wave amplitudes with and without the pump wave, this damping reduction can be used as a direct and reliable proxy for PDI growth. The method is validated in our simulations across a range of plasma and wave parameters and agrees well with theoretical predictions. Notably, the scheme exhibits no threshold for PDI excitation and is, in principle, readily implementable under current laboratory conditions. Finally, this scheme is a critical step toward solving the challenge of experimentally accessing Alfvén wave PDI and provides an elegant method that may be used to validate fundamental theories of parametric instabilities in controlled laboratory settings.

heliosphere↗

Component damage analysis

Semiconductor breakdown in aircraft was investigated since lightning strikes induce large current and voltage pulses which may cause failure. Work was done to determine whether or not these voltages and currents cause upset or damage to active or passive components. Failure thresholds were studied extensively and an assessment was made of the vulnerability of a system to a transient environment.

Franklin A Fisher↗

Design of an arc-free thermal blanket

The success of a multilayer thermal blanket in eliminating arcing is discussed. Arcing is eliminated by limiting the surface potential to well below the threshold level for discharge. This is achieved by enhancing the leakage current which results in conduction of the excess charge to the spacecraft structure. The thermal blanket consists of several layers of thermal control (space approved) materials, bonded together, with Kapton on the outside, arranged in such a way that when the outer surface is charged by electron irradiation, a strong electric field is set up on the Kapton layer resulting in a greatly improved conductivity. The basic properties of matter utilized in designing this blanket method of charge removal, and optimum thermo-optical properties are summarized.

Fellas, C. N.↗

Plasma transport in the auroral return current region

The classical and anomalous transport properties of a multifluid plasma consisting of H(+), O(+), and electron populations in the presence of auroral field-aligned return currents are investigated, using a multimoment fluid model with anomalous transport coefficients. The macroscopic effects of the electrostatic ion cyclotron (EIC) instability and of an EIC-related anomalous resistivity mechanism which heats the electrons are included in the present version of the model. The responses of the outflowing polar wind plasma to the application of current, with and without instabilities, are exhibited. The simulations show that the electron drift velocity corresponding to a return current of 0.65 micro-A/sq m is above the threshold for EIC waves. Downward electron heat flow competes with upward convection and adiabatic effects to determine the direction of the electron temperature anisotropy. Resistive electron heating lowers the critical drift velocity for marginal EIC stability and leads to enhanced ion heating.

Ganguli, Supriya B.↗

Pseudo-Random Modulation of a Laser Diode for Generating Ultrasonic Longitudinal Waves

Laser generated ultrasound systems have historically been more complicated and expensive than conventional piezoelectric based systems, and this fact has relegated the acceptance of laser based systems to niche applications for which piezoelectric based systems are less suitable. Lowering system costs, while improving throughput, increasing ultrasound signal levels, and improving signal-to-noise are goals which will help increase the general acceptance of laser based ultrasound. One current limitation with conventional laser generated ultrasound is a material s damage threshold limit. Increasing the optical power to generate more signal eventually damages the material being tested due to rapid, high heating. Generation limitations for laser based ultrasound suggests the use of pulse modulation techniques as an alternate generation method. Pulse modulation techniques can spread the laser energy over time or space, thus reducing laser power densities and minimizing damage. Previous experiments by various organizations using spatial or temporal pulse modulation have been shown to generate detectable surface, plate, and bulk ultrasonic waves with narrow frequency bandwidths . Using narrow frequency bandwidths improved signal detectability, but required the use of expensive and powerful lasers and opto-electronic systems. The use of a laser diode to generate ultrasound is attractive because of its low cost, small size, light weight, simple optics and modulation capability. The use of pulse compression techniques should allow certain types of laser diodes to produce usable ultrasonic signals. The method also does not need to be limited to narrow frequency bandwidths. The method demonstrated here uses a low power laser diode (approximately 150 mW) that is modulated by controlling the diode s drive current and the resulting signal is recovered by cross correlation. A potential application for this system which is briefly demonstrated is in detecting signals in thick composite materials where attenuation is high and signal amplitude and bandwidth are at a premium.

Madaras, Eric I.↗

Current-driven plasma acceleration versus current-driven energy dissipation. I - Wave stability theory

The dominant unstable electrostatic wave modes of an electromagnetically accelerated plasma are investigated. The study is the first part of a three-phase program aimed at characterizing the current-driven turbulent dissipation degrading the efficiency of Lorentz force plasma accelerators such as the MPD thruster. The analysis uses a kinetic theory that includes magnetic and thermal effects as well as those of an electron current transverse to the magnetic field and collisions, thus combining all the features of previous models. Analytical and numerical solutions allow a detailed description of threshold criteria, finite growth behavior, destabilization mechanisms and maximized-growth characteristics of the dominant unstable modes. The lower hybrid current-driven instability is implicated as dominant and was found to preserve its character in the collisional plasma regime.

Kelly, A. J.↗

Gas composition sensing using carbon nanotube arrays

A method and system for estimating one, two or more unknown components in a gas. A first array of spaced apart carbon nanotubes (''CNTs'') is connected to a variable pulse voltage source at a first end of at least one of the CNTs. A second end of the at least one CNT is provided with a relatively sharp tip and is located at a distance within a selected range of a constant voltage plate. A sequence of voltage pulses {V(t.sub.n)}.sub.n at times t=t.sub.n (n=1, . . . , N1; N1.gtoreq.3) is applied to the at least one CNT, and a pulse discharge breakdown threshold voltage is estimated for one or more gas components, from an analysis of a curve I(t.sub.n) for current or a curve e(t.sub.n) for electric charge transported from the at least one CNT to the constant voltage plate. Each estimated pulse discharge breakdown threshold voltage is compared with known threshold voltages for candidate gas components to estimate whether at least one candidate gas component is present in the gas. The procedure can be repeated at higher pulse voltages to estimate a pulse discharge breakdown threshold voltage for a second component present in the gas.

Li, Jing↗