Search NASA⌕ Search

SEARCH · Search NASA

Results for “TOF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Isotopic Heterogeneity Imaged in a Uranium Fuel Pellet with Extreme Ultraviolet Laser Ablation and Ionization Time-of-Flight Mass Spectrometry

We use extreme ultraviolet laser ablation and ionization time-of-flight mass spectrometry (EUV TOF) to map uranium isotopic heterogeneity at the nanoscale (=100 nm). Using low-enriched uranium fuel pellets that were made by blending two isotopically distinct feedstocks, we show that EUV TOF can map the 235U/238U content in 100 nm-sized pixels. The two-dimensional (2D) isotope maps reveal U ratio variations in sub-microscale to =1 µm areas of the pellet that had not been fully exposed by microscale or bulk mass spectrometry analyses. Compared to the ratio distribution measured in a homogeneous U reference material, the ratios in the enriched pellet follow a ~3× wider distribution. These results indicate U heterogeneity in the fuel pellet from incomplete blending of the different source materials. EUV TOF results agree well with those obtained on the same enriched pellets by nanoscale secondary ionization mass spectrometry (NanoSIMS), which reveals a comparable U isotope ratio distribution at the same spatial scale. EUV TOF’s ability to assess and map isotopic heterogeneity at the nanoscale makes it a promising tool in fields such as nuclear forensics, geochemistry, and biology that could benefit from uncovering sub-microscale sources of chemical modifications.

Rush, Lydia A.↗

Molecular Imaging of Microbially Induced Corrosion of Synthetic Archeological Glasses by a Rhizosphere Bacterium

Microbially induced corrosion (MIC) focuses on the degradation of solid materials, such as glass or metal. Soil microbes are often associated with the corrosion of foreign objects in the rhizosphere. Paenibacillus polymyxa SCE2, a facultative anaerobic bacterium in soil, is of the same genus as bacteria found near nuclear waste disposal sites. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used for imaging surface changes induced by P. polymyxa SCE2 cultured on two synthetic glass coupons to represent natural analogs of materials that were studied in relation to the vitrification of nuclear waste. Multimodal imaging was used to verify bacterial coverage across the glass surface after long-term growth. ToF-SIMS spectral analysis showed detection of glass component ions, such as silicon oxide (m/z – 59.96 SiO 2 – ) and aluminum oxide (m/z – 101.95 Al 2 O 3 – ), and biofilm’s extracellular polymeric substance (EPS) components, such as pentadecanoic acid (m/z – 241.22 C 15 H 29 O 2 – ) and sterol lipids (m/z – 311.16 C 20 H 23 O 3 – ). ToF-SIMS spectral, imaging, and depth profiling analyses showed that the glass rich in silica and other light elements (“granite glass”) had more “corrosion related” peaks than the glass that was less silica-rich and contained more iron (“dike glass”). Furthermore, these surface and interface compositional and spatial differences observed in the mass spectra and imaging were attributed to bacterial metabolism and an electron transfer mechanism influenced by morphological and compositional differences between the two types of glasses. ToF-SIMS is effective in studying microbial effects, bringing new molecular insights into MIC in a broader context of materials degradation.

Amorphous materials↗

Native MS Analysis of Bacteriorhodopsin and an Empty Nanodisc by Orthogonal Acceleration Time-of-Flight, Orbitrap and Ion Cyclotron Resonance

Over the past two decades orthogonal acceleration time-of-flight has been the de facto analyzer of choice for solution and membrane soluble protein native mass spectrometry (MS) studies; this however is gradually changing. Here we compare three MS instruments, the Q-ToF, the Orbitrap and the FT-ICR to analyze, under native instrument and buffer conditions, the 7-transmembrane helical protein bacteriorhodopsin-octylglucoside micelle complex and the empty nanodisc (MSP1D1-Nd) using both MS and tandem-MS modes of operation. Bacteriorhodopsin can be released from the octylglucoside-micelle efficiently on all three instruments (MS-mode of operation) producing a narrow charge state distribution (z = 8+ to 10+) by either increasing the source lens or collision cell (or HCD) voltages. A lower center-of-mass collision energy (0.20–0.41 eV) is required for optimal bacteriorhodopsin liberation on the FT-ICR, in comparison to the Q-ToF and Orbitrap instruments (0.29–2.47 eV). The empty MSP1D1-Nd can be measured with relative ease on a three instruments, resulting in a highly complex spectrum of overlapping, polydisperse charge state; a consequence of varying levels of phospholipid incorporation. There is a measurable difference in MSP1D1-Nd charge state distribution (z = 15+ to 26+), average molecular weight (141.7 to 169.6 kDa) and phospholipid incorporation number (143 to 184) under low activation conditions. Utilizing tandem-MS, bacteriorhodopsin can be effectively liberated from the octylglucoside-micelle by collisional (Q-ToF and FT-ICR) or continuous IRMPD activation (FT-ICR). MSP1D1-Nd spectral complexity can also be significantly reduced by tandem-MS (Q-ToF and FT-ICR) followed by mild collisional or continuous IRMPD activation, resulting in a spectrum in which the charge state and phospholipid incorporation levels can easily be determined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lead Isotope Fingerprinting of Nanoscale Mineral Particles via Single Particle Inductively Coupled Plasma Mass Spectrometry

Determining lead (Pb) isotopic ratios is of broad interest across chemical disciplines for source tracing and age determinations, but the technique is inherently limited when multiple sources of Pb are present in a single sample. Single particle methods offer a solution to directly resolve multiple distinct isotopic ratios within individual samples. In this study, single particle inductively coupled plasma-mass spectrometry (spICP-MS) was performed using time-of-flight (TOF) and multicollector (MC)-based platforms to measure the Pb isotopic composition of individual nanoscale particles. Distinct Pb isotope ratios were measured in particles from four powdered galena samples of different origins (average single-particle 206Pb/207Pb ratios ranging from 0.91 to 1.28) using both the TOF and the MC-based platforms. Differentiation of galena particles in a mixture (liberated grains and those hosted in a silicate matrix) was possible due to detecting their unique multielemental fingerprints. The differing behavior of the two galena samples during digestion was investigated; undigested galena particles trapped within silicate minerals were detected using spICP-MS, which has implications for Pb recovery in bulk-scale isotopic analysis. The multinuclide detection capability of the ICP-TOF-MS instrument allowed for the simultaneous detection of secondary constituent elements within the nanoparticles and the identification of multiple populations of isotopically distinct Pb-bearing particles in a copper ore sample, whereas the increased sensitivity of the MC instrument enabled quantification of 204Pb, allowing differentiation using multiple isotopic ratios. A single particle isotope ratio analysis module was developed within an open-source spICP-TOF-MS data processing platform, enabling its adoption across chemical disciplines.

Goodman, Aaron J. [University of Montreal, Quebec,↗

Exploiting the Semidestructive Nature of Gas Cluster Ion Beam Time-of-Flight Secondary Ion Mass Spectrometry Imaging for Simultaneous Localization and Confident Lipid Annotations

Lipids have been considered as key players in cell signaling and disease. Information on their location and distribution within a biological system, under varying conditions, is necessary to understand the contributions of different lipid species to an altered phenotype. Imaging mass spectrometry techniques, such as time-of-flight secondary ion mass spectrometry (ToF-SIMS) and matrix-assisted laser desorption/ionization (MALDI), are capable of revealing global lipid distributions in tissues in an untargeted fashion. Yet, to confidently identify the species present in a sample, orthogonal analyses like tandem MS (MS/MS) are often required. This can be accomplished by bulk sample analysis with liquid chromatography (LC)-MS/MS, which can provide confident lipid identifications, at the expense of losing location-specific information. Here, using planarian flatworms as a model system, we demonstrate that imaging gas cluster ion beam (GCIB)-ToF-SIMS has the unique capability to simultaneously detect, identify, and image lipid species with subcellular resolution in tissue sections. The parallel detection of both, intact lipids and their respective fragments, allows for unique identification of some species without the need of performing an additional orthogonal MS/MS analysis. This was accomplished by correlating intact lipid and associated fragment SIMS images. The lipid assignments, respective fragment identities, and locations gathered from ToF-SIMS data were confirmed via LC-MS/MS on lipid extracts and ultrahigh mass resolution MALDI-MS imaging. Together, these data show that the semidestructive nature of ToF-SIMS can be utilized advantageously to enable both confident molecular annotations and to determine the locations of species within a biological sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accelerated Steam Methane Reforming by Dynamically Applied Charges

Catalyst design has traditionally focused on tuning active site properties to optimally bind reaction intermediates and balance the kinetic requirements of multiple competing chemical processes, as necessitated by the Sabatier principle. It has recently been proposed that for reactions following certain potential energy landscapes, the activity limit imposed by the Sabatier principle may be overcome by using programmed oscillations of surface electron density at the timescales of surface reactions (i.e., “catalytic resonance”). Here, we use a combination of density functional theory (DFT) simulations and transient kinetic models (TKMs) to simulate the kinetics of steam methane reforming (SMR) on Ru(211) surfaces under statically and dynamically applied charges. DFT-calculated binding energies of SMR intermediates and transition states exhibit strong sensitivity to positively applied charges and follow unique scaling relationships that deviate from linear periodic trends across transition metals. Our simulations demonstrate that applying a small positive charge to Ru dramatically enhances the steady-state turnover frequency (TOF) of SMR by up to 5 orders of magnitude above the TOF observed over neutral Ru. Thus, statically charging Ru catalysts may be an effective strategy to lower the temperature requirements for SMR. Dynamic square-wave oscillations in charge resulted in SMR catalytic resonance with an onset frequency f ∼ 106 Hz and the corresponding average TOFs exceeding the statically charged Ru surface by an additional 15%. Here, based on sensitivity analyses performed for the two end points of oscillation, we propose that dynamic TOF improvement beyond the Sabatier maximum can be expected when the system oscillates between two kinetic regimes that are uniquely controlled by distinct elementary steps.

Catalysts↗

Comparison of FTIR and Particle Mass Spectrometry for the Measurement of Paticulate Organic Nitrates

While multifunctional organic nitrates are formed during the atmospheric oxidation of volatile organic compounds, relatively little is known about their signatures in particle mass spectrometers. High resolution time-of-flight aerosol mass spectrometry (HR-ToF-AMS) was applied to NH4NO3, NaNO3 and isosorbide 5-mononitrate (IMN) particles, and to secondary organic aerosol (SOA) from NO3 radical reactions at 22 C and 1 atm in air with and pinene, 3-carene, limonene and isoprene. For comparison, single particle laser ablation mass spectra (SPLAT II) were also obtained for IMN and SOA from the pinene reaction. The mass spectra of all particles exhibit significant intensity at m/z 30, and for the SOA, weak peaks corresponding to various organic fragments containing nitrogen [CxHyNzOa]+ were identified using HR-ToF-AMS. The NO+/NO2+ ratios from HR-ToF-AMS were 10-15 for IMN and the SOA from the and pinene, 3-carene and limonene reactions, ~5 for the isoprene reaction, 2.4 for NH4NO3 and 80 for NaNO3. The N/H ratios from HR-ToF-AMS for the SOA were smaller by a factor of 2 to 4 than the -ONO2/C-H ratios measured using FTIR on particles impacted on ZnSe windows. While the NO+/NO2+ ratio may provide a generic indication of organic nitrates under some conditions, specific identification of particulate organic nitrates awaits further development of particle mass spectrometry techniques.

54 ENVIRONMENTAL SCIENCES↗

High Mass Analysis with a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer: From Inorganic Salt Clusters to Antibody Conjugates and Beyond

Analysis of proteins and complexes under native mass spectrometric (MS) and solution conditions was typically performed using time-of-flight (ToF) analyzers, due to their routine high m/z transmission and detection capabilities. However, over recent years, the ability of Orbitrap-based mass spectrometers to transmit and detect a range of high molecular weight species is well documented. Herein, we describe how a 15 Tesla Fourier transform ion cyclotron resonance mass spectrometer (15 T FT-ICR MS) is more than capable of analyzing a wide range of ions in the high m/z scale (>5000), in both positive and negative instrument polarities, ranging from the inorganic cesium iodide salt clusters; a humanized IgG1k monoclonal antibody (mAb; 148.2 kDa); an IgG1-mertansine drug conjugate (148.5 kDa, drug-to-antibody ratio; DAR 2.26); an IgG1-siRNA conjugate (159.1 kDa; ribonucleic acid to antibody ratio; RAR 1); the membrane protein aquaporin-Z (97.2 kDa) liberated from a C8E4 detergent micelle; the empty MSP1D1-nanodisc (142.5 kDa) and the tetradecameric chaperone protein complex GroEL (806.2 kDa; GroEL dimer at 1.6 MDa). We also investigate different regions of the FT-ICR MS that impact ion transmission and desolvation. Finally, we demonstrate how the transmission of these species and resultant spectra are highly consistent with those previously generated on both quadrupole-ToF (Q-ToF) and Orbitrap instrumentation. This article serves as an impactful example of how FT-ICR mass analyzers are competitive to Q-ToFs and Orbitraps for high mass detection at high m/z.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of [Ni(PPh2NPh2)2(CH3CN)]2+ and [Pd(PPh2NPh2)2]2+ as Electrocatalysts for H2 Production

The complexes [Ni(PPh2NPh2)2(CH3CN)]2+ and [Pd(PPh2NPh2)2]2+, where PPh2NPh2 is 1,5-diphenyl-3,7-diphenyl-1,5-diaza-3,7-diphosphacyclooctane, are compared as electrocatalysts for H2 production under identical experimental conditions. With [(DMF)H]+ as the acid in acetonitrile solution, [Pd(PPh2NPh2)2]2+ afforded a turnover frequency (TOF) of 230 s-1 for formation of H2 under dry conditions and a TOF of 640 s-1 when H2O was added. These rates are similar to the TOF’s of 590 s-1 (dry) and 720 s-1 (wet) that were previously measured for [Ni(PPh2NPh2)2(CH3CN)]2+ using [(DMF)H]+. The [Ni(PPh2NPh2)2(CH3CN)]2+ and [Pd(PPh2NPh2)2]2+ complexes both exhibited large current enhancements when treated with trifluoroacetic acid (TFA). At a TFA concentration of 1.8 M, TOF values of 5670 s-1 and 2060 s-1 were measured for [Ni(PPh2NPh2)2(CH3CN)]2+ and [Pd(PPh2NPh2)2]2+, respectively. The fast rates observed using TFA are, in part, attributed to homoconjugation of TFA in acetonitrile solutions, which decreases the effective pKa of the acid. In support of this hypothesis, dramatically lower rates of H2 production were observed using p anisidinium, which has a pKa comparable to TFA but does not homoconjugate significantly in acetonitrile solutions. This research was supported as part of the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences. Pacific Northwest National Laboratory is oper-ated by Battelle for the U.S. Department of Energy.

electrocatalysis↗

Forward Modeling of 3-D Ion Properties in Jupiter’s Magnetosphere Using Juno/JADE-I Data

The Jovian Auroral Distributions Experiment Ion sensor (JADE-I) on NASA’s Juno mission provides in-situ measurements of ions from 0.1 to 46.2 keV/q inside Jupiter’s magnetosphere. JADE-I is used to study the plasma with two types of datasets from the same measurement: Time-of-flight (TOF) and SPECIES. The TOF dataset provides mass-per-charge measurements with a range of 1–64 amu/q but oversamples particles over 6π steradian viewing per spacecraft spin and has little directional information. On the other hand, the SPECIES dataset can provide a good measurement of the flow direction but does not provide mass-per-charge information due to the telemetry limit. In this study, we developed a 2-step forward modeling method that combines the advantages and avoids the disadvantages of TOF and SPECIES data to derive the 3-D properties of heavy ions. Assuming that the ion velocity distribution can be described with the kappa distribution, we first perform the forward model fit of the TOF data to calculate the relative abundance of heavy ion species. Then we fix the relative abundance and perform the second forward model fit on the SPECIES data. Here, using this method, we obtain the densities of different heavy ions, the shared temperature and kappa value, and the 3-D flow velocity vector. Some data examples of the equatorial plasma disk before Perijove 24 are included to demonstrate the method. Plasma properties can then be mapped to explore spatial and temporal variabilities in Jupiter’s magnetosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

Advanced characterization of surface-modified nanoparticles and nanofilled antibacterial dental adhesive resins

Nanotechnology can improve the performance of dental polymers. The objective of this study was to modify the surfaces of nanoparticles with silanes and proteins, characterize nanoparticles’ agglomeration levels and interfaces between nanoparticles and the polymeric matrix. Undoped (n-TiO 2 ), nitrogen-doped (N_TiO 2 ) and nitrogen-fluorine co-doped titanium dioxide nanoparticles (NF_TiO 2 ) were synthesized and subjected to surface modification procedures in preparation for Small-Angle X-Ray Scattering (SAXS) and Small-Angle Neutron Scattering (SANS) characterizations. Experimental adhesives were manually synthesized by incorporating 20% (v/v) of n-TiO 2 , N_TiO 2 or NF_TiO 2 (as-synthesized or surface-modified) into OptiBond Solo Plus (OPTB). Specimens (n = 15/group; d = 6.0 mm, t = 0.5 mm) of OPTB and experimental adhesives were characterized using Time-of-Flight Secondary Ion Mass Spectroscopy (ToF-SIMS), 2-D ToF-SIMS chemical imaging and SANS. SAXS results indicated that surface-modified nanoparticles displayed higher scattering intensities in a particle-size dependent manner. ToF-SIMS results demonstrated that nanoparticles’ incorporation did not adversely impact the parental polymer. 2-D ToF-SIMS chemical imaging demonstrated the distribution of Ti + and confirmed nitrogen-doping levels. SANS results confirmed nanoparticles’ functionalization and revealed the interfaces between nanoparticles and the polymer matrix. Metaloxide nanoparticles were successfully fabricated, incorporated and covalently functionalized in a commercial dental adhesive resin, thereby supporting the utilization of nanotechnology in dentistry.

60 APPLIED LIFE SCIENCES↗

Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass spectral molecular mapping shows benefits of thermal evaporation in prelithiated silicon-based electrodes

Silicon based composites have become increasingly popular as potential anodes for lithium-ion batteries due to their large storage capacity and potential ability to generate batteries with energy densities greater than 350 Wh kg −1 . These anodes often see reduced initial columbic efficiency (ICE) due to disruptive volume expansionup to 300% and continuous solid electrolyte interphase (SEI) layer formation. Prelithiation, where an excess reservoir of Li is added to the electrode to compensate for irreversible SEI formation losses during their sample preparation, has proven to solve the issue of immediate capacity loss. Thermal evaporation is a prelithiation technique with limited studies on its effectiveness. In this study, time-of-flight secondary ion mass spectrometry (ToF-SIMS) is used to highlight the benefits of prelithiation via thermal evaporation. ToF-SIMS provides chemical mapping and spatial information in 2D and 3D visualizing the deposition of lithium, identifying Li x Si y alloy and Li x Si y O z silicate formation, and the distribution of lithium passivation into the electrodes. Passivation under different atmospheric conditions, such as inert Argon (Ar) and Ar/ carbon dioxide (CO 2 ), highlights the impact of the environment on the passivation effectiveness and formation of Li x Si y alloy and Li x Si y O z silicate. The ToF-SIMS molecular imaging and depth profiling results indicate that prelithiation via thermal evaporation effectively distributes lithium throughout the depth profile thickness of several hundred nanometers. It induces a greater degree of Li x Si y O z silicate formation over Li x Si y alloy. Our ToF-SIMS characterization results show the effectiveness of thermal evaporation in producing a more stable electrode and an electrode with an effective lithium reserve that can preserve its capacity.

Parker, Gabriel D. [Oak Ridge National Laboratory ↗

Evaluation of the 235 U resonance parameters to fit the standard recommended values

A great deal of effort has been dedicated to the revision of the standard values in connection with the neutron interaction for some actinides. While standard data compilation are available for decades nuclear data evaluations included in existing nuclear data libraries (ENDF, JEFF, JENDL, etc.) do not follow the standard recommended values. Indeed, the majority of evaluations for major actinides do not conform to the standards whatsoever. In particular, for the n + 235 U interaction the only value in agreement with the standard is the thermal fission cross section. We performed a resonance re-evaluation of the n + 235 U interaction in order to address the issues regarding standard values in the energy range from 10-5 eV to 2250 eV. Recently, 235 U fission cross-section measurements have been performed at the CERN Neutron Time-o-Flight facility (TOF), known as n_TOF, in the energy range from 0.7 eV to 10 keV. The data were normalized according to the recommended standard of the fission integral in the energy range 7.8 eV to 11 eV. As a result, the n_TOF averaged fission cross sections above 100 eV are in good agreement with the standard recommended values. The n_TOF data were included in the 235 U resonance analysis that was performed with the code SAMMY. In addition to the average standard values related to the fission cross section, standard thermal values for fission, capture, and elastic cross sections were also included in the evaluation. Our paper presents the procedure used for re-evaluating the 235 U resonance parameters including the recommended standard values as well as new cross section measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recent Advances and Future Advances in Time-of-Flight PET

Simple theory predicts that the statistical noise variance in PET can be reduced by an order of magnitude by using time-of-flight (TOF) information. This reduction can be obtained by improving the coincidence timing resolution, and so would be achievable in clinical, whole body studies using with PET systems that differ little from existing cameras. The potential impact of this development is large, especially for oncology studies in large patients, where it is sorely needed. TOF PET was extensively studied in the 1980's but died away in the 1990's, as it was impossible to reliably achieve sufficient timing resolution without sacrificing other important PET performance aspects, such as spatial resolution and efficiency. Recent advances in technology (scintillators, photodetectors, and high speed electronics) have renewed interest in TOF PET, which is experiencing a rebirth. However, there is still much to be done, both in instrumentation development and evaluating the true benefits of TOF in modern clinical PET. This paper looks at what has been accomplished and what needs to be done before time-of-flight PET can reach its full potential.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A multichannel time-of-flight system for observation of energetic ions of multispecies generated from relativistic laser plasma

A multichannel time-of-flight (TOF) system was constructed to observe the ions generated from relativistic laser plasma, where the ions have polychromatic energies and multiple species. The TOF system is composed of a ten-channel scintillation detector array and an electromagnet that generates a magnetic field of 0-1.24 T. The magnet field enables us to analyze protons, deuterons, and full-stripped carbon ions to 50, 25, and 150 MeV, respectively. The system experimentally identified protons of 0.27-1.6 MeV energy and ions of a half specific charge (deuterons of 0.3-0.8 MeV and full-stripped carbons of 1.8-4.8 MeV). The measured TOF values agree well with the calculated values within the designed accuracy; {+-}2.5 ns for protons and {+-}5 ns for the others (d or C{sup 6+}) on each detector channel. Comparison of ion numbers detected by a track detector (CR-39) and the TOF system enabled us to obtain the number of ions detected on each scintillation counter with less than 16% error.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time of flight elastic recoil detection analysis with a position sensitive detector

A position sensitive detection system based on the microchannel plate detector has been constructed and installed at the existing time of flight (TOF) spectrometer in order to perform a kinematic correction and improve the surface time/depth resolution of elastic recoil detection analysis (ERDA) system. The position resolution of the detector has been tested for different types of ions and anode voltages. TOF spectra of recoiled O ions from SiO{sub 2} and F from CaF{sub 2} were collected in coincidence with position sensitive detector signal. Kinematic correction of TOF spectra improved surface time/depth resolution by {approx}20% for our system; however even higher improvements could be obtained in larger solid angle TOF-ERDA systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydrogen released from bulk ZnO single crystals investigated by time-of-flight electron-stimulated desorption

Electron beam (e-beam) irradiation effects on ZnO single crystals have been investigated by using time-of-flight electron-stimulated desorption (TOF-ESD). The samples were irradiated by using a continuous 0.5 or 1.5 keV e-beam, while the TOF-ESD spectra were taken by using a pulsed 0.5 keV e-beam. For both the O-terminated and Zn-terminated surfaces, the major desorption is H{sup +} desorption. The main trend of H{sup +} desorption intensity and evolution as a function of irradiation time is similar for both faces. The H{sup +} peak is much higher after 1.5 keV irradiation than after 0.5 keV irradiation. The intensity of the H{sup +} peak decreases exponentially as a function of irradiation time and partially recovers after the irradiation is stopped. These observations suggest that the main contribution of the H{sup +} desorption is hydrogen released from the dissociation of H-related defects and complexes in the bulk region of the ZnO by e-beam irradiation. This finding can be used to explain the reported ultraviolet degradation of ZnO single crystals under electron irradiation observed by cathodoluminescence. The surfaces play a lesser role for the H{sup +} desorption, as there are differences of the decreasing rate between the two faces and additionally the intensity of the H{sup +} peak for both the unclean O-face and Zn-facesis smaller than that for clean faces. While the H{sup +} desorption is mainly dominated by the bulk region, O{sup +} desorption is more influenced by the surfaces. There are two kinds of O{sup +} desorbed from ZnO having 13.0 {mu}s TOF and 14.2 {mu}s TOF. The O{sup +} desorption depends on the surface polarity, the surface conditions and the energy used for irradiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗