Search NASA⌕ Search

SEARCH · Search NASA

Results for “TOF resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

The Neutron Macromolecular Crystallography Instruments at Oak Ridge National Laboratory: Advances, Challenges, and Opportunities

The IMAGINE and MaNDi instruments, located at Oak Ridge National Laboratory High Flux Isotope Reactor and Spallation Neutron Source, respectively, are powerful tools for determining the positions of hydrogen atoms in biological macromolecules and their ligands, orienting water molecules, and for differentiating chemical states in macromolecular structures. The possibility to model hydrogen and deuterium atoms in neutron structures arises from the strong interaction of neutrons with the nuclei of these isotopes. Positions can be unambiguously assigned from diffraction studies at the 1.5–2.5 Å resolutions, which are typical for protein crystals. Neutrons have the additional benefit for structural biology of not inducing radiation damage to protein crystals, which can be critical in the study of metalloproteins. Here we review the specifications of the IMAGINE and MaNDi beamlines and illustrate their complementarity. IMAGINE is suitable for crystals with unit cell edges up to 150 Å using a quasi-Laue technique, whereas MaNDi provides neutron crystallography resources for large unit cell samples with unit cell edges up to 300 Å using the time of flight (TOF) Laue technique. The microbial culture and crystal growth facilities which support the IMAGINE and MaNDi user programs are also described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Programmable Chemical Gradient Patterns by Soft Grayscale Lithography

A method for fabricating chemical gradients on planar and nonplanar substrates using grayscale lithography is reported. Compliant grayscale amplitude masks are fabricated using a vacuum-assisted microfluidic filling protocol that employs dilutions of a carbon-black-containing polydimethylsiloxane emulsion (bPDMS) within traditional clear PDMS (cPDMS) to create planar, fully self-supporting mask elements. The mask is then placed over a surface functionalized with a hydrophobic coumarin-based photocleavable monolayer, which exposes a polar group upon irradiation. The mask serves to modulate the intensity of incident UV light, thereby controlling the density of molecules cleaved. The resulting molecular-level grayscale patterns are characterized by condensation microscopy and imaging mode time-of-flight secondary-ion mass spectrometry (ToF-SIMS). Due to the inherent flexibility of this technique, the photofuse as well as the gradient patterns can be designed for a wide range of applications; in this paper two proof-of-concept demonstrations are shown. The first utilizes the ability to control the resulting contact angle of the surface for the fabrication of a passive pressure-sensitive microfluidic gating system. The second is a model surface modification process that utilizes the functional groups deprotected during the photocleavage to pattern the deposition of moieties with complementary chemistry. The spatial layout, resolution, and concentration of these covalently linked molecules follow the gradient pattern created by the grayscale mask during exposure. Furthermore, the programmable chemical gradient fabrication scheme presented in this work allows explicit engineering of both surface properties that dictate nonspecific interactions (surface energy, charge, etc.) and functional chemistry necessary for covalent bonding.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of an epithermal neutron velocity selection system for the Penn State Breazeale Reactor

A series of mechanical neutron choppers to operate as a velocity selection system have been developed for the Pennsylvania State Breazeal Reactor (PSBR). This chopper system will provide pulsed epithermal neutrons in the energy range of 0.5–40 eV with 2% or better energy resolution, and with a transmission of 1E-6 or better. Four different chopper geometries have been evaluated for their utility as mechanical neutron choppers. Specifically, Fermi, ring, piston, and disc choppers have been evaluated to assess their potential neutronics performance and mechanical constructability. A series of high-speed disc choppers were selected for the final design, and optimization work was performed to maximize the neutron pulse intensity. It is estimated that the optimized system will produce an epithermal neutron intensity of approximately 96 n/s. This system can also be operated in a time of flight (TOF) configuration such that the neutrons arriving at the source have a white spectrum. This operation can be accomplished by leaving the second stage of choppers in the open position, or by removing it from the beam completely. Such unique source of epithermal neutrons produced by this chopper system will have applications in both prompt and delayed epithermal neutron activation analysis (ENAA), as well as in neutron resonance transmission analysis (NRTA).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-of-Flight Mass Measurements of Exotic Nuclei

Atomic masses play an important role in nuclear physics and astrophysics. The need of experimental mass values for unstable nuclides has triggered the development of a wide range of mass measurement techniques, with devices installed at many laboratories around the world. We have implemented a time-of-flight magnetic-rigidity (TOF-B ) technique at the National Superconducting Cyclotron Laboratory (NSCL) that includes a position measurement for magnetic rigidity corrections and uses the A1900 separator and the S800 spectrograph. We performed a successful first experiment measuring masses of neutron-rich isotopes in the region of Z 20 30, important for calculations of processes occurring in the crust of accreting neutron stars. The masses of 16 nuclei were determined, for 61V, 63Cr, 66Mn, and 74Ni for the first time, with atomic mass excesses of 30.510(890) MeV, 35.280(650) MeV, 36.900(790) MeV, and 49.210(990) MeV, respectively. The mass resolution achieved was 1.8 10 4.

Matos, M.↗

Extreme Ultraviolet and Beyond Extreme Ultraviolet Lithography Using Amorphous Zeolitic Imidazolate Resists Deposited by Atomic/Molecular Layer Deposition

Amorphous zinc-imidazolate (aZnMIm) resists show potential to meet the demands for next-generation high-numerical aperture (high-NA) metal-containing extreme ultraviolet (EUV) resist materials, given their ease of deposition by atomic/molecular layer deposition (ALD/MLD) at thicknesses of 20 nm and below. Here, this study demonstrates that aZnMIm thin films, previously identified as high-resolution electron beam resists, can also function as negative-tone EUV photoresists. Water development achieves high sensitivity (5 mJ/cm 2 ) but leaves significant residue, while acetic acid development results in poor contrast. A hybrid approach─water followed by acetic acid─enables residue-free development with a sensitivity of 181 mJ/cm 2 . Dry development using 1,1,1,5,5,5-hexafluoroacetylacetone (hfacH) is also possible but shows lower sensitivity (375 mJ/cm 2 ) compared to wet development methods. EUV photoelectron spectroscopy (PES), reflectometry/EUV absorption, total electron yield (TEY), residual gas analysis (RGA), and time-of-flight secondary ion mass spectrometry (TOF-SIMS) were used to investigate the effects of EUV irradiation on aZnMIm resists. Reflectometry experiments reveal an aZnMIm EUV absorption coefficient of 6.2 μm –1 , while PES and TEY analyses show that, compared to poly(4-hydroxystyrene) (PHS), a polymer-based reference resist, aZnMIm emits more primary and secondary electrons but generates fewer slow electrons relative to its primary electron emission; its total electron yield is similar to that of poly(methyl methacrylate) (PMMA) resists. When exposed to EUV, aZnMIm predominantly outgasses H 2 , as determined by RGA. TOF-SIMS measurements demonstrate that high-dose EUV exposure only partially fragments the 2-methylimidazole (2MIm) organic linkers, unlike high-dose electron beam exposure, which is known to completely degrade them. Additionally, aZnMIm resists show promise for potential beyond EUV lithography (BEUVL) due to the presence of Zn, which provides higher sensitivity at a wavelength of 6.7 nm compared to other metal ions, such as Sn, that are currently used in the best-performing EUV metal–organic resists. TEY measurements demonstrate that aZnMIm emits nearly twice as many electrons as PHS at 6.7 nm. The BEUV TEY of aZnMIm also surpasses that of PMMA, poly(pentafluorostyrene), and poly(4-iodostyrene), with the latter two being known for their high EUV TEYs. This work provides insight into zeolitic imidazolate framework (ZIF)-based EUV and BEUV resists and highlights their potential for both wet and dry development.

lithography↗

The Solar Neutron TRACking (SONTRAC) Instrument for the Detection of Fast Neutrons

The detection of fast neutrons has important applications in several fields including solar, Geospace and planetary physics. Neutrons are challenging to detect and measurements of them typically suffer from high background rates. High-energy neutrons (>50 MeV) pose even more challenges, because the traditional double-scatter technique based on a time-of-flight (ToF) measurement is limited by short flight paths and small detector sizes characteristic of small satellite platforms. It is now possible to perform high-energy neutron measurements inside a large monolithic detector by imaging the recoil proton tracks, thus eliminating the need for a measure of the time-of-flight. The concept is based on a spectrometer assembled from numerous thin hydrogenous scintillating fibers that allow ionization track imaging. Fine grained readout is now possible with arrays of1-mm pitch silicon photomultipliers (SiPMs). The Solar Neutron TRACking (SONTRAC) instrument, equipped with scintillating fibers readout with SiPMs sensors, provides high-resolution, fine grained, imaging of fast (between 20-200 MeV) neutron scatters in a compact, low-power design ideal for small satellite(and aircraft) platforms. We discuss below applications of this technology and performance characteristics of the prototype SONTRAC instrument.

de Nolfo, Georgia A.↗

WE-E-18A-01: Large Area Avalanche Amorphous Selenium Sensors for Low Dose X-Ray Imaging

Purpose: A large area indirect flat panel imager (FPI) with avalanche gain is being developed to achieve x-ray quantum noise limited low dose imaging. It uses a thin optical sensing layer of amorphous selenium (a-Se), known as High-Gain Avalanche Rushing Photoconductor (HARP), to detect optical photons generated from a high resolution x-ray scintillator. We will report initial results in the fabrication of a solid-state HARP structure suitable for a large area FPI. Our objective is to establish the blocking layer structures and defect suppression mechanisms that provide stable and uniform avalanche gain. Methods: Samples were fabricated as follows: (1) ITO signal electrode. (2) Electron blocking layer. (3) A 15 micron layer of intrinsic a-Se. (4) Transparent hole blocking layer. (5) Multiple semitransparent bias electrodes to investigate avalanche gain uniformity over a large area. The sample was exposed to 50ps optical excitation pulses through the bias electrode. Transient time of flight (TOF) and integrated charge was measured. A charge transport simulation was developed to investigate the effects of varying blocking layer charge carrier mobility on defect suppression, avalanche gain and temporal performance. Results: Avalanche gain of ∼200 was achieved experimentally with our multi-layer HARP samples. Simulations using the experimental sensor structure produced the same magnitude of gain as a function of electric field. The simulation predicted that the high dark current at a point defect can be reduced by two orders of magnitude by blocking layer optimization which can prevent irreversible damage while normal operation remained unaffected. Conclusion: We presented the first solid state HARP structure directly scalable to a large area FPI. We have shown reproducible and uniform avalanche gain of 200. By reducing mobility of the blocking layers we can suppress defects and maintain stable avalanche. Future work will optimize the blocking layers to prevent lag and ghosting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

YSO implantation detector for beta-delayed neutron spectroscopy

A segmented-scintillator-based implantation detector was developed to study the energy distribution of β-delayed neutrons emitted from exotic isotopes. The detector comprises a 34 × 34 YSO scintillator coupled to an 8 × 8 anode Position-Sensitive Photo-Multiplier Tube (PSPMT) via a tapered light guide. The detector was used at RIBF, RIKEN for time-of-flight-based neutron spectroscopy measurement in the 78Ni region. The detector provides the position and timing resolution necessary for ion-beta correlations and time of flight measurements. The detector provides a high ~80% beta-detection efficiency and a sub-nanosecond timing resolution. This contribution discusses the details of the design, operation, implementation, and analysis developed to obtain neutron time-of-flight spectrum and the analysis methods in the context of neutron-rich nuclei in the 78Ni region.

Implantation detector↗

Improving metastable impact electron spectroscopy and ultraviolet photoelectron spectroscopy signals by means of a modified time-of-flight separation

The separation of ultraviolet photoelectron spectroscopy (UPS) and metastable impact electron spectroscopy (MIES) is usually performed by a time-of-flight (ToF) separation using pre-set ToF for both types of signal. In this work, we present a new, improved ex situ signal separation method for the separation of MIES and UPS for every single measurement. Signal separation issues due to changes of system parameters can be overcome by changing the ToF separation and therefore allowing for the application of a wider range of measuring conditions. The method also enables to identify and achieve separation of the two signals without any time consuming calibration and the use of any special material for the calibration. Furthermore, changes made to the discharge source are described that enable to operate an existing MIES/UPS source over a broader range of conditions. This allows for tuning of the yield of UV photons and metastable rare gas atoms leading to an improved signal to noise ratio. First results of this improved setup are well in agreement with spectra reported in literature and show increased resolution and higher signal intensities for both MIE and UP spectra compared to the previous, non-optimized setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An FPGA Wave Union TDC for Time-of-Flight Applications

An 18-channel time-of-flight (TOF) grade time-to-digit converter (TDC) has been implemented in a low cost FPGA device. The TDC has the following unique features. (1) The time recording structures of the TDC is based on the 'wave union TDC' we developed in our previous work. A leading edge of the input hit launches a bit pattern, or wave union into the delay chain-register array structure which yields two usable measurements. The two measurements effectively sub-divide timing bins for each other especially the 'ultra-wide bins' caused by the FPGA logic array block (LAB) structure and improves measurement precision both in terms of maximum bin width and RMS resolution. A coarser measurement on input signal trailing edge is also provided for time-over-threshold (TOT) applications. (2) The TDC supports advanced timing reference distribution schemes that are superior to conventional common start/stop schemes. The TDC has 16 regular measurement channels plus two channels for timing reference. The timing reference is established with multiple measurements rather than single shot common start/stop. An advanced scheme, the mean-timing approach even eliminates needs of high quality timing distribution media. (3) The ASIC-like encapsulation of the FPGA TDC significantly shorten the learning curve for potential users while maintain certain flexibility for various applications. Necessary digital post-processing functions including semicontinuous automatic calibration, data buffer, data link jam prevention logic etc. are integrated into the firmware to provide a turn-key solution for users.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Clusters of Monoisotopic Elements for Calibration in (TOF) Mass Spectrometry

Precise calibration in TOF MS requires suitable and reliable standards, which are not always available for high masses. We evaluated inorganic clusters of the monoisotopic elements gold and phosphorus (Au{sub n}{sup +}/Au{sub n}{sup -} and P{sub n}{sup +}/P{sub n}{sup -}) as an alternative to peptides or proteins for the external and internal calibration of mass spectra in various experimental and instrumental scenarios. Monoisotopic gold or phosphorus clusters can be easily generated in situ from suitable precursors by laser desorption/ionization (LDI) or matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Their use offers numerous advantages, including simplicity of preparation, biological inertness, and exact mass determination even at lower mass resolution. We used citrate-stabilized gold nanoparticles to generate gold calibration clusters, and red phosphorus powder to generate phosphorus clusters. Both elements can be added to samples to perform internal calibration up to mass-to-charge (m/z) 10–15,000 without significantly interfering with the analyte. We demonstrated the use of the gold and phosphorous clusters in the MS analysis of complex biological samples, including microbial standards and total extracts of mouse embryonic fibroblasts. We believe that clusters of monoisotopic elements could be used as generally applicable calibrants for complex biological samples. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Li 3– x Zr x (Ho/Lu) 1– x Cl 6 Solid Electrolytes Enable Ultrahigh-Loading Solid-State Batteries with a Prelithiated Si Anode

We report two new families of lithium metal chloride solid electrolytes Li 3–x Zr x (M) 1–x Cl 6 (0 ≤ x ≤ 0.8; M = Ho or Lu) with ionic conductivities of up to 1.8 mS cm –1 and a low activation energy of 0.34 eV. Structural elucidation via high-resolution neutron diffraction determines the Li ion distribution in trigonal Li 3 HoCl 6 , orthorhombic-I Li 3 LuCl 6 , and orthorhombic-II Li 2.4 Zr 0.6 (Ho/Lu) 0.4 Cl 6 . The last compound exhibits well-connected Li-ion pathways and abundant Li-ion carriers/vacancies to promote diffusion. All-solid-state batteries with Li 2.6 Zr 0.4 (Ho/Lu) 0.6 Cl 6 solid electrolytes and NCM85 cathodes exhibit stable cycling up to 4.6 V vs Li + /Li, which is even preserved up to 4.8 V. Stable cathode interphases are formed for both electrolytes upon cycling to 4.3, 4.6, and 4.8 V cutoff potentials, as identified by a ToF-SIMS analysis. Solid-state cells with a prelithiated Li 0.7 Si anode exhibit a significantly increased initial coulombic efficiency of 94.5% compared to Si and a high areal capacity of up to 16.3 mAh·cm –2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward Revealing Microcystin Distribution in Mouse Liver Tissue Using MALDI-MS Imaging

Cyanotoxins can be found in water and air during cyanobacterial harmful algal blooms (cHABs) in lakes and rivers. Therefore, it is very important to monitor their potential uptake by animals and humans as well as their health effects and distribution in affected organs. Herein, the distribution of hepatotoxic peptide microcystin-LR (MC-LR) is investigated in liver tissues of mice gavaged with this most common MC congener. Preliminary matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) imaging experiments performed using a non-automated MALDI matrix deposition device and a MALDI-time-of-flight (TOF) mass spectrometer yielded ambiguous results in terms of MC-LR distribution in liver samples obtained from MC-LR-gavaged mice. The tissue preparation for MALDI-MS imaging was improved by using an automated sprayer for matrix deposition, and liver sections were imaged using an Nd:YAG MALDI laser coupled to a 15 Tesla Fourier-transform ion cyclotron resonance (FT-ICR)-mass spectrometer. MALDI-FT-ICR-MS imaging provided unambiguous detection of protonated MC-LR (calculated m/z 995.5560, z = +1) and the sodium adduct of MC-LR (m/z 1017.5380, z = +1) in liver sections from gavaged mice with great mass accuracy and ultra-high mass resolution. Since both covalently bound and free MC-LR can be found in liver of mice exposed to this toxin, the present results indicate that the distribution of free microcystins in tissue sections from affected organs, such as liver, can be monitored with high-resolution MALDI-MS imaging.

59 BASIC BIOLOGICAL SCIENCES↗

Water–gas shift reaction over gold nanoparticles dispersed on nanostructured CeO x –TiO 2 (110) surfaces: Effects of high ceria coverage

We used scanning tunnelling microscopy to study the morphology of an overlayer of ceria in contact with a TiO 2 (110) substrate. Two types of domains were observed after ceria deposition. An ordered ceria film covered half of the surface and high-resolution imaging suggested a near-c(6 × 2) relationship to the underlying TiO 2 (110)-(1 × 1). For the other half of the surface, it comprised CeO x nanoparticles and reconstructed TiOx supported on TiO 2 (110)-(1 × 1). Exposure to a small amount of gold resulted in the formation of isolated gold atoms and small clusters on the ordered ceria film and TiO 2 (110)-(1 × 1) areas, which exhibited significant sintering at 500 K and showed strong interaction between the sintered gold clusters and the domain boundaries of the ceria film. The Au/CeO x /TiO 2 (110) model system proved to be a good catalyst for the water–gas shift (WGS) exhibiting much higher turnover frequencies (TOFs) than Cu(111) and Pt(111) benchmarks, or the individual Au/TiO 2 (110) and Au/CeO 2 (111) systems. Finally, for Au/CeO x /TiO 2 (110) catalysts, there was a decrease in catalytic activity with increasing ceria coverage that correlates with a reduction in the concentration of Ce 3 + formed during WGS reaction conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Morphology and CO Oxidation Activity of Pd Nanoparticles on SrTiO 3 Nanopolyhedra

Single crystal SrTiO 3 nanocuboids having primarily TiO 2 -(001) surfaces and nanododecahedra having primarily (110) surfaces were created by two separate hydrothermal synthesis processes. Pd nanoparticles grown on the two sets of STO nanopolyhedra by atomic layer deposition show different morphologies and CO oxidation performance. Transmission electron microscopy and small-angle X-ray scattering show that 2-3 nm Pd nanoparticles with 3-5 nm interparticle distances decorate the STO surfaces. When the number of ALD cycles increases, the growth of the Pd nanoparticles is more significant in size on TiO 2 -(001)-STO surfaces, while that on (110)-STO surfaces is more predominant in number. High resolution electron microscopy images show that single crystal and multiply twinned Pd nanoparticles coexist on both types of the STO nanopolyhedra and exhibit different degrees of adhesion. The CO oxidation reaction, which was employed to determine the dependence of catalytic activity, demonstrated that the Pd catalytic performance was dominated by the coverage of CO, which is more directly related to Pd nanoparticle size than to shape. CO turnover frequency analysis and diffuse reflectance infrared Fourier transform spectroscopy show that regardless of the shape or degrees of wetting, larger Pd nanoparticles (~ 3 nm) have lower catalytic activity due to high CO coverage on nanoparticle facets. Smaller nanoparticles (~ 2 nm) have more edge and corner sites and present 2-3 times higher TOF at 80 and 100 degrees C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vertical gradient freeze growth of detector grade CdZnTeSe single crystals

Here, we report the growth of detector grade Cd 0.9 Zn 0.1 Te 0.97 Se 0.03 (CZTS) single crystals, a recently discovered quaternary semiconductor for room temperature radiation detection, by a vertical gradient freeze (VGF) method. VGF is a comparatively low-temperature growth method and avoids relative motion between the heater and the ampoule containing the precursor materials which minimizes any thermal drift or temperature fluctuations. As a result, CZTS single crystals with superior charge transport properties has been obtained. Growth of detector-grade CZTS single crystals using VGF method has not been reported yet. X-ray spectroscopy based elemental analysis showed that the grown crystals demonstrated the desired stoichiometry required for high resolution radiation detection. Planar detectors fabricated by deposition of gold contacts (~0.07 cm 2 ) demonstrated high bulk resistivity ~10 10 Ω-cm and a very low leakage current density of 2.8 × 10 –8 A/cm 2 at a bias of 100 V when measured at room temperature. The detectors showed excellent radiation response with 100 % charge collection efficiency when exposed to 5486 keV alpha particles. The electron mobility-lifetime (μτ) product was measured to be 3 × 10 –3 cm 2 /V using a single polarity Hecht analysis which is at par with the recently reported values measured in CZTS grown using conventional Bridgman or travelling heater method. The electron mobility has been calculated to be 964 cm 2 V –1 s –1 using a time-of-flight (TOF) method, a substantial improvement over that obtained from conventionally grown CZTS single crystals.

36 MATERIALS SCIENCE↗

CHERENCUBE: Concept definition and implementation challenges of a Cherenkov-based detector block for PET

Purpose: A new concept for a depth-of-interaction (DOI) capable time-of-flight (TOF) PET detector is defined, based only on the detection of Cherenkov photons. The proposed “CHERENCUBE” consists of a cubic Cherenkov radiator with position-sensitive photodetectors covering each crystal face. By means of the spatial distribution of the detected photons and their time of arrival, the point of interaction of the gamma-ray in the crystal can be determined. This study analyzes through theoretical calculations and Monte Carlo simulations the potential advantages of the concept toward reaching a Cherenkov-only detector for TOF-PET with DOI capability. Furthermore, an algorithm for the DOI estimation is presented and the requirements for a practical implementation of the proposed concept are defined. Methods: The Monte Carlo simulations consisted of a cubic crystal with one photodetector coupled to each one of the faces of the cube. The sensitive area of the detector matched exactly the crystal size, which was varied in 1 mm steps between 1 × 1 × 1 mm{sup 3} and 10 × 10 × 10 mm{sup 3}. For each size, five independent simulations of ten thousand 511 keV gamma-rays were triggered at a fixed distance of 10 mm. The crystal chosen was PbWO{sub 4}. Its scintillation properties were simulated, but only Cherenkov photons were analyzed. Photodetectors were simulated having perfect photodetection efficiency and infinite time resolution. For every generated particle, the analysis considered its creation process, parent and daughter particles, energy, origin coordinates, trajectory, and time and position of detection. The DOI determination is based on the distribution of the emission time of all photons per event. These values are calculated as a function of the coordinates of detection and origin for every photon. The common origin is estimated by finding the distribution with the most similar emission time-points. Results: Detection efficiency increases with crystal size from 8.2% (1 × 1 × 1 mm{sup 3}) to 58.6% (10 × 10 × 10 mm{sup 3}) and decreases applying a photon detection threshold of 5/10/20 photons to 6.3%/4.3%/0.7% and 49.3%/30.4%/2.8%, respectively. The detection rate in the six photodetectors is uniform due to the nearly isotropic cone emission. Most cones originated after a photoelectric effect interaction, with two dominating peaks for the kinetic energy of the electron at 422.99 and 441.47 keV. The detection distance between same-event photons defines the spatial resolution of the detector required for individual photon recognition, with 20% of the detected photons having their closest neighbor within a distance of 5% of the length of the cube. Same-event photons are detected within a time window whose width is determined by the crystal size, with values of 30 and 150 ps for a 1 × 1 × 1 mm{sup 3} and a 10 × 10 × 10 mm{sup 3} cube, respectively. The DOI reconstruction has an accuracy of approximately 23% of the length of the cube, with an average value of 2.2 mm for a 10 × 10 × 10 mm{sup 3} CHERENCUBE. Conclusions: The proposed concept requires a detector with high photodetection efficiency. The structure of the sensitive surface of the detector should be a two dimensional array of microcells, able to provide individual detection coordinates and time stamps. The microcell size determines the ability to recognize individual photons, influencing detection efficiency. The 3D DOI recognition relies on the accuracy of the time stamps and detection coordinates, without the need for a recognition of the projected patterns of photons. The refractive index of the material defines a detector intrinsic energy-based rejection of scattered PET events at the cost of reduced sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multi-threshold sampling method for TOF PET signal processing

As an approach to realizing all-digital data acquisition for positron emission tomography (PET), we have previously proposed and studied a multithreshold sampling method to generate samples of a PET event waveform with respect to a few user-defined amplitudes. In this sampling scheme, one can extract both the energy and timing information for an event. In this paper, we report our prototype implementation of this sampling method and the performance results obtained with this prototype. The prototype consists of two multi-threshold discriminator boards and a time-to-digital converter (TDC) board. Each of the multi-threshold discriminator boards takes one input and provides up to 8 threshold levels, which can be defined by users, for sampling the input signal. The TDC board employs the CERN HPTDC chip that determines the digitized times of the leading and falling edges of the discriminator output pulses. We connect our prototype electronics to the outputs of two Hamamatsu R9800 photomultiplier tubes (PMTs) that are individually coupled to a 6.25 x 6.25 x 25mm{sup 3} LSO crystal. By analyzing waveform samples generated by using four thresholds, we obtain a coincidence timing resolution of about 340 ps and an {approx}18% energy resolution at 511 keV. We are also able to estimate the decay-time constant from the resulting samples and obtain a mean value of 44 ns with an {approx}9 ns FWHM. In comparison, using digitized waveforms obtained at a 20 GSps sampling rate for the same LSO/PMT modules we obtain {approx}300 ps coincidence timing resolution, {approx}14% energy resolution at 511 keV, and {approx}5 ns FWHM for the estimated decay-time constant. Details of the results on the timing and energy resolutions by using the multi-threshold method indicate that it is a promising approach for implementing digital PET data acquisition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗