Search NASA⌕ Search

SEARCH · Search NASA

Results for “Technology and Operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

NECQST: Novel Electronics for Cryogenic Quantum Sensors Technology

Development of low-noise cryogenic readout circuits for SNSPDs based on state-of-the art, commercially available SiGe HBT technology, operating at a range of 1-4 Kelvin. Targeting a reduction of the timing jitter of SNSPDs (from the current record of 2.7 ps FWHM at 400 nm), and a reduction in the power dissipation allowed by the development of dedicated low-noise cryogenic amplifiers, which will enable the scaling of ultra-low-jitter SNSPDs to large arrays. Such performance advances will directly benefit the Caltech/Fermilab INQNET (Intelligent Quantum Networks & Technologies) program, which aims to demonstrate high-rate quantum communication at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recommendations for Distributed Energy Resource Patching

While computer systems, software applications, and operational technology (OT)/Industrial Control System (ICS) devices are regularly updated through automated and manual processes, there are several unique challenges associated with distributed energy resource (DER) patching. Millions of DER devices from dozens of vendors have been deployed in home, corporate, and utility network environments that may or may not be internet-connected. These devices make up a growing portion of the electric power critical infrastructure system and are expected to operate for decades. During that operational period, it is anticipated that critical and noncritical firmware patches will be regularly created to improve DER functional capabilities or repair security deficiencies in the equipment. The SunSpec/Sandia DER Cybersecurity Workgroup created a Patching Subgroup to investigate appropriate recommendations for the DER patching, holding fortnightly meetings for more than nine months. The group focused on DER equipment, but the observations and recommendations contained in this report also apply to DERMS tools and other OT equipment used in the end-to-end DER communication environment. The group found there were many standards and guides that discuss firmware lifecycles, patch and asset management, and code-signing implementations, but did not singularly cover the needs of the DER industry. This report collates best practices from these standards organizations and establishes a set of best practices that may be used as a basis for future national or international patching guides or standards.

97 MATHEMATICS AND COMPUTING↗

Evolving Architectures and Considerations to address Distributed Energy Resources and Non-Wired Alternatives

The electric grid is in the beginning stage of a transformation, driven by a combination of shutdowns of coal-fired plants, commissioning of new natural-gas plants, and tremendous growth in energy supply from renewables such as wind, and solar. As utilities navigate this transformation, their progress is supported by advances in Operational Technologies (OT), and Informational Technologies (IT), such as automation, smart inverters, cloud computing, mobile computing, machine learning, big data analytics, which have the potential to enable advanced capabilities more efficiently and at a lower cost. This white paper focuses on the architectural considerations that will allow the industry to transition in a planned manner. It introduces and formalizes two architectural constructs –the data bus and the control bus. The data bus is responsible for carrying all non-operational models and information necessary to drive utility decisions. In contrast, the control bus is responsible for carrying all operational data and control actions taken at the local level, centralized level, or other levels in-between. The paper reviews those architectural considerations, their requirements and how they will evolve. This paper intends to provide a context for vendors, utilities, and their service providers to review and understand the changes that are coming and get ready for them.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Patterns of Variation in the External Quantum Efficiency of InGaN/GaN Green LEDs during Accelerated Tests

The causes and mechanisms of variation in the quantum efficiency and other characteristics of InGaN/GaN heterostructures are actively investigated in various operating modes. The results are presented from an experimental study of the variation in the external quantum efficiency of low-power InGaN/GaN green light-emitting diodes with and without a quantum well in the space–charge region (SCR) of the heterostructure in the accelerated test mode. It is found that after 8 hours of testing at a temperature of 300 K in the pulse mode with a pulse amplitude of 0.5 A, a pulse duration of 100 µs, and a duty cycle of 100, the external quantum efficiency grows for all LEDs without a quantum well in the SCR and diminishes for LEDs with a quantum well throughout the range of operating currents. It is shown that at a low level of injection, the intensity of emission of light emitting diodes without a quantum well in the SCR is determined by recombination processes according to the Shockley–Read–Hall mechanism, while that of LEDs with a quantum well is determined by tunneling–recombination processes. Current training of green LEDs based on InGaN/GaN heterostructures in the forced pulse mode for 4 hours can be used as a technological operation for stabilizing their lighting characteristics, and for identifying potentially unreliable products under conditions of mass production.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrity Enhancing Protocols: Performance and Recommendations for Nuclear Systems

In today’s communication landscape there are multiple technologies and protocols used for communication between end devices. Within security paradigms for these protocols, integrity management is a common goal of system designers. Communication protocols focused on maintaining message integrity can provide assurance that some received data has not been altered or tampered with. While integrity is often coupled with confidentiality in protocol design, this analysis focuses on an evaluation of only integrity protocols. This report outlines various ways message integrity may be preserved with respect to high performance operational technology (OT) systems. It describes a series of experiments and an evaluation framework used to evaluate the performance of the identified integrity approaches regarding common system design goals. Finally, it addresses the testing environment utilized and closes the report with a summary of experimental results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sustainable solid waste management: An integrated approach for Asian countries

Solid waste management (SWM) has been an integral part of every human society. The approaches for SWM should be compatible with the nature of a given society, and, in this regard, Asian countries are no exception. In keeping with global trends, the systems are being oriented to concentrate on sustainability issues; mainly through the incorporation of 3R (reduce, reuse and recycle) technologies. However, degree and nature of improvements toward sustainability are varying and depend on the economic status of a country. High-income countries like Japan and South Korea can afford to spend more to incorporate 3R technologies. Most of the latest efforts focus on 'Zero Waste' and/or 'Zero Landfilling' which is certainly expensive for weaker economies such as those of India or Indonesia. There is a need to pragmatically assess the expectations of SWM systems in Asian countries. Hence, in this paper, we analyze the situation in different Asian countries, and explore future trends. We conceptually evaluate issues surrounding the sustainability of SWM. We propose a multi-pronged integrated approach for improvement that achieves sustainable SWM in the context of national policy and legal frameworks, institutional arrangement, appropriate technology, operational and financial management, and public awareness and participation. In keeping with this approach, a generic action plan has been proposed that could be tailored to suit a situation in a particular country. Our proposed concept and action plan framework would be useful across a variety of country-specific scenarios.

54 ENVIRONMENTAL SCIENCES↗

INS–Support for Formal Cyber Security Education in Brazil–After Action Report

The adoption of digital technology into Instrumentation and Control (I&C) systems in nuclear facilities fundamentally changes the nature of these systems. Greater interconnectivity of reprogrammable, and functionally interdependent control systems has given rise to the need for computer security consideration in digital I&C Systems. The cyber security of I&C systems presents a growing risk to nuclear facilities and requires the development of educational and research tools to ensure the safety of these facilities. Currently there is a major gap in formal educational offerings on cyber security for these Operational Technology (OT) systems. To provide formal cyber security education resources, DOE’s office of International Nuclear Security (INS) partnered with the University of São Paulo (USP) to develop a training course on the cyber security of nuclear facility I&C systems using the hypothetical Nuclear Power Plant, Asherah.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-Power Ion Thruster Development Status

An effort is on-going to examine scaling relationships and design criteria for ion propulsion systems, and to address the need for a light weight, low power, high specific impulse propulsion option for small spacecraft. An element of this activity is the development of a low-power (sub-0.5 kW) ion thruster. This development effort has led to the fabrication and preliminary performance assessment of an 8 cm prototype xenon ion thruster operating over an input power envelope of 0.1-0.3 kW. Efficiencies for the thruster vary from 0.31 at 1750 seconds specific impulse at 0.1 kW, to about 0.48 at 2700 seconds specific impulse and 0.3 kW input power. Discharge losses for the thruster over this power range varied from about 320-380 W/A down to about 220-250 W/A. Ion optics performance compare favorably to that obtained with 30 cm ion optics, when scaled for the difference in beam area. The neutralizer, fabricated using 3 mm hollow cathode technology, operated at keeper currents of about 0.2-0.3 A, at a xenon flow rate of about 0.06 mg/s, over the 0.1-0.3 kW thruster input power envelope.

Patterson, Michael J.↗

A Cybersecurity Testbed for Smart Buildings

Smart buildings are equipped with a plethora of cyber-physical systems, such as Internet of Things (IoT) devices and building automation systems. These devices, especially in commercial buildings, use legacy communications and hardware that were not designed with cybersecurity in mind. With increasing cyber threats in recent years, smart buildings have become an increasing target for attacks, but not enough published data are available from these incidents to study or replicate the scenarios to defend buildings. As part of the U.S. Department of Energy-funded project focusing on developing the Building Intelligence with Layered Defense Using Security-Constrained Optimization and Security Risk Detection (BUILD-SOS) platform, we developed a cybersecurity test bed for smart buildings. This test bed includes a building simulation tool, virtual devices, emulated operational technology networks, and remote hardware-in-the-loop. Using this test bed, we performed different cyberattacks on the smart building model and collected both physical building data, to understand the impacts on the building, and network data, to aid in separating mechanical faults from cyberattacks during the detection. This test bed is a significant tool in protecting smart buildings from cyberattacks because they can aid in both cybersecurity analysis and the evaluation of cyberattack detection tools by testing the tools in a secure environment without impacting the building operations.

alfalfa↗

Cubesat Proximity Operations Demonstration (CPOD)

The CubeSat Proximity Operations Demonstration (CPOD) project will demonstrate rendezvous, proximity operations and docking (RPOD) using two 3-unit (3U) CubeSats. Each CubeSat is a satellite with the dimensions 4 inches x 4 inches x 13 inches (10 centimeters x 10 centimeters x 33 centimeters) and weighing approximately 11 pounds (5 kilograms). This flight demonstration will validate and characterize many new miniature low-power proximity operations technologies applicable to future missions. This mission will advance the state of the art in nanosatellite attitude determination,navigation and control systems, in addition to demonstrating relative navigation capabilities.The two CPOD satellites are scheduled to be launched together to low-Earth orbit no earlier than Dec. 1, 2015.

Relative navigation capabilities↗

A Cybersecurity Testbed for Smart Buildings

Smart buildings are equipped with a plethora of cyber-physical systems, such as Internet of Things (IoT) devices and building automation systems. These devices, especially in commercial buildings, use legacy communications and hardware that were not designed with cybersecurity in mind. With increasing cyber threats in recent years, smart buildings have become an increasing target for attacks, but not enough published data are available from these incidents to study or replicate the scenarios to defend buildings. As part of the U.S. Department of Energy-funded project focusing on developing the Building Intelligence with Layered Defense Using Security-Constrained Optimization and Security Risk Detection (BUILD-SOS) platform, we developed a cybersecurity test bed for smart buildings. This test bed includes a building simulation tool, virtual devices, emulated operational technology networks, and remote hardware-in-the-loop. Using this test bed, we performed different cyberattacks on the smart building model and collected both physical building data, to understand the impacts on the building, and network data, to aid in separating mechanical faults from cyberattacks during the detection. This test bed is a significant tool in protecting smart buildings from cyberattacks because it can aid in both cybersecurity analysis and the evaluation of other cyberattack detection tools by testing the tools in a secure environment without impacting the building operations.

cyber-physical systems↗

1st Advanced Marine Renewable Energy Instrumentation Experts Workshop: April 5-7, 2011

The U.S. marine energy industry is actively pursuing development of offshore wind and marine hydrokinetic (MHK) energy systems. Experience in the wind energy sector demonstrates that new technology development requires thorough measurement and characterization of the environmental conditions prevalent at installation sites and of technology operating in the field. Presently, there are no turn-keyinstrumentation system solutions that meet the measurement needs of the marine energy industry. The 1st Advanced Marine Renewable Energy Instrumentation Experts Workshop brought together technical experts from government laboratories, academia, and industry representatives from marine energy, wind, offshore oil and gas, and instrumentation developers to present and discuss the instrumentationneeds of the marine energy industry. The goals of the meeting were to: 1. Share the latest relevant knowledge among technical experts; 2. Review relevant state-of-the-art field measurement technologies and methods; 3. Review lessons learned from recent field deployments; 4. Identify synergies across different industries; 5. Identify gaps between existing and needed instrumentation capabilities;6. Understand who are the leading experts; 7. Provide a forum where stakeholders from the marine energy industry could provide substantive input in the development of new marine energy field deployable instrumentation packages.

13 HYDRO ENERGY↗

1st Advanced Marine Renewable Energy Instrumentation Experts Workshop

The U.S. marine energy industry is actively pursuing development of offshore wind and marine hydrokinetic (MHK) energy systems. Experience in the wind energy sector demonstrates that new technology development requires thorough measurement and characterization of the environmental conditions prevalent at installation sites and of technology operating in the field. Presently, there are no turn-key instrumentation system solutions that meet the measurement needs of the marine energy industry. The 1st Advanced Marine Renewable Energy Instrumentation Experts Workshop brought together technical experts from government laboratories, academia, and industry representatives from marine energy, wind, offshore oil and gas, and instrumentation developers to present and discuss the instrumentation needs of the marine energy industry. The goals of the meeting were to: 1. Share the latest relevant knowledge among technical experts; 2. Review relevant state-of-the-art field measurement technologies and methods; 3. Review lessons learned from recent field deployments; 4. Identify synergies across different industries; 5. Identify gaps between existing and needed instrumentation capabilities; 6. Understand who are the leading experts; 7. Provide a forum where stakeholders from the marine energy industry could provide substantive input in the development of new marine energy field deployable instrumentation packages.

DOE/GO-102011-3342↗

Assessing Anomaly-Based Intrusion Detection Configurations for Industrial Control Systems

To reduce cost and ease maintenance, industrial control systems (ICS) have adopted Ethernetbased interconnections that integrate operational technology (OT) systems with information technology (IT) networks. This integration has made these critical systems vulnerable to attack. Security solutions tailored to ICS environments are an active area of research. Anomalybased network intrusion detection systems are well-suited for these environments. Often these systems must be optimized for their specific environment. In prior work, we introduced a method for assessing the impact of various anomaly-based network IDS settings on security. This paper reviews the experimental outcomes when we applied our method to a full-scale ICS test bed using actual attacks. Our method provides new and valuable data to operators enabling more informed decisions about IDS configurations.

Gillen, Rob↗

Method for Assessment of Security-Relevant Settings in Anomaly-Based Intrusion Detection for Industrial Control Systems

Ensuring the integrity of Ethernet-based networks is a challenging and constantly evolving domain. This problem is exacerbated for those operational technology (OT) networks supporting industrial control systems (ICS) since much of that equipment was originally designed to be on a network that was isolated and generally considered free of malefactors. Increasing pressure to bridge these systems with traditional information technology (IT) networks has introduced a bevy of new threats. In response, both academia and industry have responded with security solutions tailored to ICS environments. Deploying these protection systems often involves several configuration choices. While some of these choices are clear (e.g., block/enable protocol X) others are far more subjective (e.g. alert threshold == 3.43). Further complicating the situation, while often similar to IT networks, OT networks have unique challenges and characteristics that make the task of protecting them simultaneously more difficult and straight forward.Extant solutions for quantifying the relative security of intrusion detection systems fail to effectively support the operators of said systems with understanding the impact of various configuration changes. Further, they assume that the attacks are static and not subject to manipulation or alteration in the face of defenses. In this paper, we present a threat-based method for quantifying the relative impact of various security settings for intrusion detection systems (IDSs) within ICS environments. This method provides operational staff with a clear understanding of the relative impact of their settings and assumes that the attacks levied against them are dynamic. The model is described in detail, we apply the model to a synthetic data set, and discuss the inferences that can be made and what types of decisions they could be used to support.

Gillen, Rob↗

Oak Ridge National Laboratory Pilot Demonstration of an Attestation and Anomaly Detection Framework using Distributed Ledger Technology for Power Grid Infrastructure

This report summarizes the design and pilot demonstration of a framework called Grid Guard that was created to provide increased data and device trustworthiness to electric grid devices by leveraging distributed ledger technology (DLT), specifically blockchain. Grid Guard contains a combination of core cryptographic methods such as the secure hash algorithm (SHA), and asymmetric cryptography, private permissioned blockchain, baselining configuration data, consensus algorithm (Raft) and the Hyperledger Fabric (HLF) framework. The system implements a low energy, fast, and robust enhancement to system trustworthiness within and across electric grid systems such as substations, control centers and metering infrastructures. Blockchain is a distributed database structured that provides a practically unalterable (immutable) timeline of stored transactions. By relying on hashing and the Raft consensus algorithm, if an entity tries to illegitimately alter a record at one instance of the database the other ledger nodes are not altered. They work to cross-reference each other and easily locate any incorrectly added data and remove it. The bulk raw data is stored in an off-chain storage (outside of the blockchain ledger) and a hash of this baseline data is stored in the Blockchain ledger via hashing windows of time-series and configuration data, after aggregation and filtering. The bulk off-chain data repository is then considered to be trust-anchored using the hashes stored in the blockchain. To secure the electric grid testbed devices and data, device configuration baselines were compared to those baselines that had been previously stored in the ledger. Statistical baselines for device configurations, network communication patterns, and high-speed sensor data are calculated and then stored off-chain and hashes stored in the ledger. Measurements such as three-phase voltage and current, frequency, breaker status, protection scheme settings, network configuration settings (and other device configuration artifacts) and network traffic features (packet interarrival times) are compared every minute or other selected time windows. During phase 1 of the Grid Guard DLT project different DLT technologies were studies, and an assessment was performed on DLT technology vulnerabilities, uses, and key characteristics. DLT consensus protocols were studies (e.g., RAFT, named after Reliable, Replicated, Redundant, And Fault-Tolerant). Also, cryptography, public, private and permissioned or permissionless systems were assessed. Grid Guard implements a permissioned private DLT. Consensus algorithm selection and choice of DLT implementation depended heavily on the use-case. For this use-case, parameters were selected to measure performance and existing tools for assessment. Benchmarking was performed theoretically and practically. During phase 2 hashed transactions/blocks were inserted into the ledger every second. During phase 2 of the Grid Guard DLT project, a prototype framework was developed and demonstrated for attestation of critical substation devices and data using precision timing systems that use PTP and IRIG-B protocols) on a testbed of operational devices that emulated a distribution substation, control center, and power metering infrastructure using real Operational Technology (OT). The testbed includes OT devices such as protective relays, human machine interfaces (HMI), and power meters. To determine when to collect and compare system and network baselines, an initial examination of an anomaly detection capability to identify malicious manipulation of data streams was conducted. The resulting anomaly detection was demonstrated in a set of experiments and leveraged to trigger device artifact attestation checks. Attestation checks occur against device configuration baselines when compared with the immutable blockchain-stored baselines, which provided a cryptographically supported means by which to store baselines. The electrical substation-grid testbed was created to test the Grid Guard framework. The testbed emulates the operations of a portion of a power grid and SCADA systems as closely as possible. The testbed integrates real protocols, mainly IEC 61850 standard protocols, such as the Sampled Value (SV) and the GOOSE protocols. The testbed also supports DNP3 and other layer 2 and layer 3 protocols such as Telnet, SSH, SFTP/FTP and other proprietary protocols needed to connect to industrial control system equipment. The testbed emulates real power conditions using the OpalRT hardware-in-the-loop (HIL) device which can create fault situations that cannot be easily tested on real systems. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that electrical utilities commonly use.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Emerging Technologies for Privacy Preservation in Energy Systems

This study explores the intersection of digitalization and privacy within the energy sector, focusing on the emerging challenges and opportunities presented by integrating Distributed Energy Resources (DERs) and advanced metering infrastructure. The need for robust digital privacy measures has become crucial as the energy industry evolves towards a more decentralized, digitalized, and decarbonized future. This study delves into four cutting-edge privacy-preserving technologies—Homomorphic Encryption (HE), Secure Multiparty Computation (SMPC), Differential Privacy (DP), and Federated Learning (FL)—each offering unique solutions to safeguard consumer data by increasing digital connectivity and data exchange. Through a detailed examination of these methods, the study explains how each technology operates, its applications within the energy sector, and the specific privacy challenges it addresses. Homomorphic Encryption allows for secure computations on encrypted data, enabling data analysis without compromising privacy. Secure Multiparty Computation enables collaborative data analysis across different entities while protecting the confidentiality of the inputs. Differential Privacy introduces randomness into the assembled data set, preventing the identification of individual records in statistical databases. Lastly, Federated Learning offers a paradigm shift in data analysis, where machine learning models are trained at the edge, minimizing the centralization of sensitive data. The research underscores the significance of implementing these privacy-enhancing technologies to comply with strict data protection regulations, foster consumer trust, and enhance the security of the energy infrastructure. By providing a comprehensive overview of these methodologies and their practical implications for the energy sector, this study aims to contribute to the ongoing discourse on digital privacy, offering insights into how the energy industry can navigate the complexities of data privacy in the digital age.

Cali, Umit↗

Radiation Hardness Assurance: Evolving for NewSpace

During the past decade, government agencies, private companies and academic institutions, have launched hundreds of small satellites into space, with dramatically expanded dependence on advanced commercial-off-the-shelf (COTS) technologies and systems required for mission success. While the radiation effects vulnerabilities of components within small satellites are the same as those of their larger, traditional relatives, revised approaches are needed for risk management because of differences in technical requirements and programmatic resources. While moving to COTS components and systems may reduce direct costs and procurement lead times, it undermines many cost-reduction strategies used for conventional radiation hardness assurance (RHA). Limited resources are accompanied by a lack of radiation testing and analysis, which can pose significant risks. Small satellites have benefited from short mission durations in low Earth orbits with respect to their radiation response, but as mission objectives grow and become reliant on advanced technologies operating for longer and in harsher environments, requirements need to reflect the changing scope without hindering developers that provide new capabilities. In this course we suggest RHA strategies that engineers and scientists can apply to a wide range of aerospace systems, including constellations, with a focus on how to manage aggressive system scaling for smaller platforms.

Radiation Hardness Assurance (RHA)↗