Search NASA⌕ Search

SEARCH · Search NASA

Results for “URANIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Gamma Spectrometry Code Rodeo for Uranium Enrichment—FY 2021 Report

In FY22, the participating Department of Energy (DOE) laboratories continued the work on the project “Gamma Spectrometry Code Rodeo for Uranium Enrichment”. Oak Ridge National Laboratory (ORNL) and Lawrence Livermore National Laboratory (LLNL) continued their efforts to acquire spectra using uranium sources. A collimator (with side and back shields) was custom designed and constructed at ORNL. Spectra were acquired at ORNL using the uranium enrichment standards supplied by New Brunswick Laboratory (NBL) and the collimated M400 detector. Spectra were also acquired using steel absorbers of different thickness placed between the source and the collimated M400 detector. The plan was to ship the collimator to LLNL so that spectra could be acquired using the LLNL detector in collimated geometries. This activity was suspended since problems were noticed with the performance of the LLNL M400 detector. Also, it was brought to light to the project team that some of the aspects of the M400 detector had been updated by the vendor H3D in response to requests by the IAEA. In February 2021, the ORNL and LLNL M400 detectors were returned to the H3D factory in order to resolve the problems with the LLNL detector and to update ORNL and LLNL detectors to the same configuration as the M400 supplied to the IAEA. H3D repaired the LLNL M400 and performed the IAEA updates on both the ORNL and LLNL detectors. ORNL and LLNL received the detectors in April 2021. Data acquisition was continued using the upgraded detectors. ORNL re-collected the spectra using point sources and the NBL standards in uncollimated and collimated geometries. The collimator was shipped from ORNL to LLNL. Spectra were acquired at LLNL through Q4 of FY22. When the ORNL spectra were examined closely, it became apparent that there were spurious artifacts present in some of the spectra. This rendered suspect the ORNL spectra collected in June/July 2021 time frame. ORNL contacted H3D and per H3D’s advice, the M400 detector was returned to H3D for repairs in mid-August 2021. H3D diagnosed the problem and established that the root cause was the extra tight packaging that created a strain on the CZT crystals, causing one of them to break down. The repaired M400 was returned to ORNL in early September 2021. ORNL re-started data acquisition for the third time. Data was continued to be acquired at ORNL and LLNL through September 2021. The ORNL and LLNL data will be shared with the principal investigators from the analyzing laboratories. The GADRAS code and FRAM have been developed to have the capability to analyze the M400 spectra. Good quality spectra from FY21 have been analyzed using modified versions of GADRAS and FRAM. The spectra have also been analyzed using the GEM code. The analysis results from GADRAS, FRAM and GEM codes are presented and discussed in this report. Some preliminary results from FRAM and GEM analysis were presented in February 2021 at the U-Pu Isotopics Workshop sponsored by the IAEA. CZTU code is being modified to analyze M400 spectra. Data collection, code development and analysis will be continued in FY22 as per the FY22 Project Work Plan (PWP).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ambient melting behavior of stoichiometric uranium oxides

As UO 2 is easily oxidized during the nuclear fuel cycle it is important to have a detailed understanding of the structures and properties of the oxidation products. Experimental work over the years has revealed many stable uranium oxides including UO 2 , U 4 O 9 (UO 2.25 ), U 3 O 7 (UO 2.33 ), U 2 O 5 (UO 2.5 ), U 3 O 8 (UO 2.67 ), and UO 3 , all with a number of different polymorphs. These oxides are broadly split into two categories, fluorite-based structures with stoichiometries in the range of UO 2 to UO 2.5 and less dense layered-type structures with stoichiometries in the range of UO 2.5 to UO 3 . While UO 2 is well characterized, both experimentally and computationally, there is a paucity of data concerning higher stoichiometry oxides in the literature. In this work we determine the ambient melting points of all the six stoichiometric uranium oxides listed above and compare them to the available experimental and/or theoretical data. We demonstrate that a family of the six ambient melting points map out a solid-liquid transition boundary consistent with the high-temperature portion of the phase diagram of uranium-oxygen system suggested by Babelot et al.

Burakovsky, Leonid↗

Angular Distribution of Characteristic Radiation Following the Excitation of He-Like Uranium in Relativistic Collisions

In this paper, we present an experimental and theoretical study of excitation processes for the heaviest stable helium-like ion, that is, He-like uranium occurring in relativistic collisions with hydrogen and argon targets. In particular, we concentrate on angular distributions of the characteristic Kα radiation following the K → L excitation of He-like uranium. We pay special attention to the magnetic sub-level population of the excited 1s2lj states, which is directly related to the angular distribution of the characteristic Kα radiation. We show that the experimental data can be well described by calculations taking into account the excitation by the target nucleus as well as by the target electrons. Moreover, we demonstrate for the first time an important influence of the electron-impact excitation process on the angular distributions of the Kα radiation produced by excitation of He-like uranium in collisions with different targets.

74 ATOMIC AND MOLECULAR PHYSICS↗

Editorial for Special Issue “Environmentally Sound In Situ Recovery Mining of Uranium”

This Special Issue features seven articles that cover a range of topics pertaining to the environmentally sound in situ recovery mining of uranium (U ISR). The topics include: (1) methods for assessing the potential environmental impacts of future U ISR operations using historical operational records and available geohydrologic, geochemical and climate data in a specific regional setting; (2) laboratory column studies to parameterize a uranium surface complexation model that can be used to predict uranium fate and transport in groundwater; and (3) a field evaluation of both a chemical reductant and a biostimulant to promote reducing geochemical conditions after oxidative mining at a U ISR facility.

54 ENVIRONMENTAL SCIENCES↗

Probing U 5f Covalency in Uranium Compounds through Oxidant 2p Bonding

Oxidant K (1s) X-ray Emission Spectroscopy (XES) was used to investigate covalency in the Oxidant 2p – Uranium 5f bonds of Uranium Dioxide (UO 2 ) and Uranium Tetrafluoride (UF 4 ). It will be shown that the width of the 2p Occupied Density of States (ODOS), determined from the XES measurements, correlates with the increased 5f covalency of UO 2 and the increased ionicity of UF 4 . Analysis of the XES results includes comparison to spectral simulations, cluster calculations and peak fitting, demonstrating the potential of the oxidant XES measurements as a probe of 5f covalency.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

MULTIPHYSICS-MODELING OF FIRE-INDUCED URANIUM AEROSOL FORMATION – A-POSTERIORI BENCHMARKING OF EXPERIMENTS

The formulation and solution of a model that properly described the temperature profiles of uranium in fire conditions was prepared, verified and validated, to support a-posteriori benchmarking of historical experiments. Data from the multi-physics model combined with data regression from the experiments provides a useful tool for exploring sources of potential bias in historical experiments. The approaches used are augmented by visual observations and photographic evidence allowing for correlations between various phenomena, independent of whether or not that specific phenomena are part of the validated model. In this manner, the validated model is a tool for a-posteriori benchmarking, and not a model designed to replicate the experimental output exactly for any specific experiment. For experiments like the Clark (2015) experiments, this integrated model (including chemistry) demonstrated that the largest bias was associated in the metallurgy of the coupons. The model developed does serve as a basis for defending which of the historical alloys tested are the most appropriate for any other alloy being considered (e.g., one that has not yet been tested). The model identifies key reactions that impact uranium chemistry and can significantly bias experimental results. Through use of the model and energy balances, data from historical experiments by Elder and Tinkle (1980) were regressed and benchmarked. This study identifies that all uranium alloys are not equal and that there are distinct differences between the dominant alloys representing distinct metallurgical phases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Assay Low Enriched Uranium Pyroprocessing and Electrometallurgical Treatment at the Fuel Conditioning Facility

Fuel Conditioning Facility (FCF) fulfills part of INL’s mission by reprocessing irradiated sodium-bonded fuel from the EBR-ll reactor and participates in research to further explore the fuel cycle for recovery of fuel from a variety of current reactors in use today. The fuel cycle of a nuclear reactor under the current non-proliferation act, leaves unused fuel in the spent fuel rods. The rods are safely stored until their fuel can be recovered. ? Fuel recovery from the EBR-II fuel pins has several steps to separate the uranium from the salts. The pyroprocessing technology involves high - temperatures, chemical and electrochemical methods for separating the unused uranium from the salts, fission products, and used fuel. The recovered uranium is then remixed and formed into ingots or Regulus with an enrichment of < 20% U-235. This final product is a source to fuel current nuclear reactors as well as research and development for future nuclear reactors

99 GENERAL AND MISCELLANEOUS↗

Methods that purify uranium

A method for purifying uranium includes forming primary uranyl peroxide precipitates (UO 2 O 2 .4H 2 O). Forming the primary uranyl peroxide precipitates includes obtaining impure uranium dissolved in an acidic solution, evaporating the acidic solution to increase uranium concentration and to form a concentrated solution, mixing a hydrogen peroxide (H 2 O 2 ) solution with the concentrated solution in a first container, and forming uranyl peroxide precipitates in the first container. The method includes collecting the uranyl peroxide precipitates and washing and drying the uranyl peroxide precipitates. The method also includes converting the washed and dried uranyl peroxide precipitates into triuranium octoxide (U 3 O 8 ).

Du, Miting↗

Technology Development of a High-Capacity High-Assay Low Enriched Uranium Transportation Concept

This paper discusses the technology development (TD) efforts that led to the development of a High-Capacity High-Assay Low Enriched Uranium Transportation (HALEU) transportation concept. In 2018, the Department of Energy (DOE) Office of Nuclear Technology and Research Development tasked Idaho National Laboratory (INL) to investigate strategies to transport large quantities of HALEU. To complete this task, INL collaborated with Pacific Northwest National Laboratory and Oak Ridge National Laboratory. The project was completed in 2020, and one of the project outcomes was a transportation concept that consisting of five individual Type B packages transported on a single legal-weight truck (LWT). The total payload capacity of this concept is 1,881 kg (4,149 lb) of HALEU in the form of uranium dioxide (UO2) powder. The concept utilizes an existing Type B packaging design carrying a novel fuel basket design with an incorporated flux trap. The basket can be loaded with 18 individual fuel canisters. The research collaboration investigated the U.S. certification potential of this concept. This part of the project included evaluations of criticality safety, radiological safety, thermal safety, structural integrity, and confinement under hypothetical accident scenarios of transport. The results of these evaluations demonstrated a promising potential for U.S. certification of this concept. Eventually, the described efforts led to the pursuance and issuance of a U.S. patent, thus, protecting the associated intellectual property (IP). Current short-term goals include making this IP available to private industry partners for licensing, directly supporting DOE’s objectives of accelerating commercialization of national laboratory-generated IP. If additional funding becomes available, long-term research goals could include exploring the feasibility of transporting other uranium chemical forms (e.g., UF4) with this concept, or refining operational procedures to load or unload the packagings.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Uranium Doped Gallium Nitride Epitaxial Thin Films

Gallium nitride (GaN) is near ubiquitous in modern day technologies, forming the backbone of solid-state lighting and high-power electronics. Engineering the physical properties of GaN has been investigated to some degree by the incorporation or doping of most of the elements of the periodic table, but the actinides remain unexplored. Molecular beam epitaxy is used to demonstrate uranium doping of GaN single crystals. High structural quality of the host matrix is maintained despite partial elemental segregation of the uranium dopant into 1D structures at the levels presented here. Electronic transport measurements reveal relatively high conductivity, which persists down to cryogenic temperature and is characterized by the formation of narrow gaps in the electronic band structures very close to the Fermi level. Photoluminescence measurements reveal that the U-doped GaN exhibits optical behavior similar to that of the GaN substrate. The addition of actinide materials to a non-centrosymmetric, optically active, radiation-hard, and electronically tunable host matrix opens a world of possibilities for investigating and leveraging elements with high electron correlations in the pursuit of novel devices.

36 - MATERIALS SCIENCE↗

An Allyl Uranium(IV) Sandwich Complex: Are ϕ Bonding Interactions Possible?

Abstract A method to explore head‐to‐head ϕ back‐bonding from uranium f‐orbitals into allyl π* orbitals has been pursued. Anionic allyl groups were coordinated to uranium with tethered anilide ligands, then the products were investigated by using NMR spectroscopy, single‐crystal XRD, and theoretical methods. The (allyl)silylanilide ligand, N ‐((dimethyl)prop‐2‐enylsilyl)‐2,6‐diisopropylaniline (LH), was used as either the fully protonated, singly deprotonated, or doubly deprotonated form, thereby highlighting the stability and versatility of the silylanilide motif. A free, neutral allyl group was observed in UI 2 (L1) 2 ( 1 ), which was synthesized by using the mono‐deprotonated ligand [K][ N ‐((dimethyl)prop‐2‐enyl)silyl)‐2,6‐diisopropylanilide] (L1). The desired homoleptic sandwich complex U[L2] 2 ( 2 ) was prepared from all three ligand precursors, but the most consistent results came from using the dipotassium salt of the doubly deprotonated ligand [K] 2 [ N ‐((dimethyl)propenidesilyl)‐2,6‐diisopropylanilide] (L2). This allyl‐based sandwich complex was studied by using theoretical techniques with supporting experimental spectroscopy to investigate the potential for phi (ϕ) back‐bonding. The bonding between U IV and the allyl fragments is best described as ligand‐to‐metal electron donation from a two carbon fragment‐localized electron density into empty f‐orbitals.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

An improved method for uranium separation from urine for rapid bioassay by inductively coupled plasma mass spectrometry

Bioassay monitoring is an important capability for any facility that works with significant amounts of radioactive material. The speed at which these analyses can be made is critical in the event of a potential exposure. Here, we present a new method that facilitates the rapid separation of uranium from a urine matrix for assay and isotopic determination by inductively coupled plasma mass spectrometry. This method is validated with archived urine samples that were previously analyzed using established, more time consuming methods. The sources of uncertainty for uranium assay and isotopic measurements are modelled using the Monte Carlo method to better understand the precision and accuracy of this method at the limit of quantification.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

International interlaboratory compilation of trace element concentrations in the CUP-2 uranium ore concentrate standard

Herein, a nuclear forensics investigation involving a uranium ore concentrate relies on accurate and precise analysis of impurities. Analytical data defensibility requires the use of reference materials as part of quality control. This study presents a compilation of trace element concentration results of the CUP-2 Uranium Ore Concentrate Standard measured by 11 different laboratories. The laboratories employed various dissolution methods, analytical preparation methods, and instrumental platforms. The data presented here contain concentrations of 66 impurities with up to 138 individual data points for each impurity. Consensus values have been assigned to each impurity following a statistical analysis of the data set.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Collaborative Study for Certification of Trace Elements in Uranium Ore Concentrate CRMs UCLO-1, UCHI-1, and UPER-1

Trace impurity patterns are important nuclear forensic signatures in uranium ore concentrates (UOCs) and Certified Reference Materials (CRMs) are used to validate the analysis methods employed by end users. Herein, we discuss the certification campaign for three new UOC CRMs from the National Research Council Canada: UCLO-1 (https://doi.org/10.4224/crm.2020.uclo-1), UCHI-1 (https://doi.org/10.4224/crm.2020.uchi-1), and UPER-1 (https://doi.org/10.4224/crm.2020.uper-1). This study involved 15 laboratories from 10 countries, using sector-field and (triple) quadrupole inductively-coupled plasma mass spectrometry to analyze 64 trace element impurities. We discuss the importance of the acids used for sample digestion, difficulties analyzing in a high uranium matrix, and data combination and uncertainty evaluation for this large dataset.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Qualitative assessment of uranium ore concentrates and related materials using scanning electron microscopy

Several studies have evaluated the morphology of uranium compounds produced under controlled conditions at the laboratory scale, but it is unclear whether the morphological characteristics of these materials persist in commercially produced uranium ore concentrates (UOCs). To assess the morphology in “real-world” UOCs, we qualitatively evaluated the morphological profile of secondary electron images from over 100 commercial UOCs using a previously published lexicon. We observe differences between samples with differing chemical composition and samples with similar chemical composition and differing provenance. Further, this work contextualizes morphology for commercially produced UOCs and will provide a basis for future machine learning efforts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary investigation of an uncertainty budget for uranium isotope ratio analysis using a liquid sampling—atmospheric pressure glow discharge—orbitrap mass spectrometer system

The liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source has proven to be an effective analysis tool for making uranium isotope ratio measurements when coupled to high-resolution mass spectrometers, such as the Orbitrap. While previous studies have shown the capabilities of the LS-APGD for isotope ratio determination, a systematic evaluation of the measurement uncertainty of the technique has not been conducted. To this end, the International Standards Organizations (ISO) guidelines to the expression of uncertainty in measurement (GUM analysis) have been applied to generate an uncertainty budget. For this work, a preliminary assessment derived from the GUM analysis was performed. The uncertainty in the instrument blank determination has been identified as a primary factor contributing to measurement uncertainty for the LS-APGD-Orbitrap method. These findings for the specific test case of uranium isotopic analysis will be invaluable in applications across the breadth of isotope ratio mass spectrometry performed on this unique instrumental platform.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Model ages of three uranium metal CRMs and implications for radiochronometry data interpretation

In this study, we report 230 Th/ 234 U and 231 Pa/ 235 U model ages in three uranium metal certified reference materials with distinct production histories and isotopic compositions ranging from depleted to highly enriched (CRMs 112-A, 115, and 116-A). Here, our results provide the first model age values for these materials using multiple radiochronometers, which can be used as reference values for quality control of radiochronometry measurements performed during nuclear forensic investigations. Furthermore, we evaluate the model ages in the context of available production records for the materials, which provides insight into the processes that may impact radiochronometry systems during uranium metal production.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Sample screening of uranium ore concentrates using portable spectrophotometers: investigating the correlation between visible colors and chemical signatures

A research collaboration between the Japan Atomic Energy Agency and the Department of Energy’s National Nuclear Security Administration examined nuclear forensic signatures and analytical methods for tracing the origins of uranium ore concentrates (UOCs). Here, this study focuses on utilizing portable spectrophotometers capable of reflectance measurements in the visible light spectrum as a potential rapid screening tool for nuclear forensics analysis. Unlike laboratory-based near-infrared spectroscopy or digital image analysis, this research investigated the potential to correlate visible color measurements with key nuclear forensics signatures using seven types of UOC samples with known origins and three UOC certified reference materials. Results demonstrated that distinct color groups, quantified using CIELAB values, correlated with major uranium compounds. Furthermore, the findings indicated that trace elements can influence the UOC colors, providing additional insights into material characteristics. Although this approach requires further validation across a broader range of UOC species, this study demonstrated that simple colorimetric analysis using visible spectrophotometry, which does not require complex sample preparation or data processing, can serve as a practical and novel rapid tool for preliminary screening and attribution in nuclear forensics investigations.

and nuclear chemistry↗