Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ultrasonication”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Ultrasonic Doppler measurement of renal artery blood flow

Implantable pulsed Doppler ultrasonic flowmeter development has resulted in designs for application to the aortas of dogs and humans, and to human renal and coronary arteries. A figure of merit was derived for each design, indicating the degree of its precision. An H-array design for transcutaneous observation of blood flow was developed and tested in vitro. Two other simplified designs for the same purpose obviate the need to determine vessel orientation. One of these will be developed in the next time period. Techniques for intraoperative use and for implantation have had mixed success. While satisfactory on large vessels, higher ultrasonic frequencies and alteration of transducer design are required for satisfactory operation of pulsed Doppler flowmeters with small vessels.

Source record↗

Computer automation of ultrasonic testing

Report describes a prototype computer-automated ultrasonic system developed for the inspection of weldments. This system can be operated in three modes: manual, automatic, and computer-controlled. In the computer-controlled mode, the system will automatically acquire, process, analyze, store, and display ultrasonic inspection data in real-time. Flaw size (in cross-section), location (depth), and type (porosity-like or crack-like) can be automatically discerned and displayed. The results and pertinent parameters are recorded.

Yee, B. G. W.↗

A transmission oscillator ultrasonic spectrometer

A continuous wave ultrasonic instrument capable of measuring very small changes in acoustic attenuation and phase velocity is described. This transmission oscillator ultrasonic spectrometer (TOUS) exhibits high sensitivity because it oscillates marginally. In spite of this high sensitivity, the TOUS system is relatively simple, compact, and inexpensive. These features suggest that the TOUS is suitable not only for precise laboratory measurements of the physical properties of materials, but also for field applications in nondestructive testing.

Conradi, M. S.↗

The feasibility of ranking material fracture toughness by ultrasonic attenuation measurements

A preliminary study was conducted to assess the feasibility of ultrasonically ranking material fracture toughness. Specimens of two grades of maraging steel for which fracture toughness values were measured were subjected to ultrasonic probing. The slope of the attenuation coefficient versus frequency curve was empirically correlated with the plane strain fracture toughness value for each grade of steel.

Vary, A.↗

Monitoring crack extension in fracture toughness tests by ultrasonics

An ultrasonic method was used to observe the onset of crack extension and to monitor continued crack growth in fracture toughness specimens during three point bend tests. A 20 MHz transducer was used with commercially available equipment to detect average crack extension less than 0.09 mm. The material tested was a 300-grade maraging steel in the annealed condition. A crack extension resistance curve was developed to demonstrate the usefulness of the ultrasonic method for minimizing the number of tests required to generate such curves.

Klima, S. J.↗

The feasibility of ranking material fracture toughness by ultrasonic attenuation measurements

A preliminary study was conducted to assess the feasibility of ultrasonically ranking material fracture toughness. Specimens of two grades of maraging steel for which fracture toughness values were measured were subjected to ultrasonic probing. The slope of the attenuation coefficient vs frequency curve was empirically correlated with the plane strain fracture toughness value for each grade of steel.

Vary, A.↗

Ultrasonic corona sensor study

The overall objective of this program is to determine the feasibility of using ultrasonic (above 20 kHz) corona detection techniques to detect low order (non-arcing) coronas in varying degrees of vacuum within large high vacuum test chambers, and to design, fabricate, and deliver a prototype ultrasonic corona sensor.

Harrold, R. T.↗

Ultrasonic evaluation of the strength of unidirectional graphite-polyimide composites

An acoustic-ultrasonic method is described that was successful in ranking unidirectional graphite-polyimide composite specimens according to variations in interlaminar shear strength. Using this method, a quantity termed the stress wave factor was determined. It was found that this factor increases directly with interlaminar shear strength. The key variables in this investigation were composite density, fiber weight fraction, and void content. The stress wave factor and other ultrasonic factors that were studied were found to provide a powerful means for nondestructive evaluation of mechanical strength properties.

Vary, A.↗

Monitoring crack extension in fracture toughness tests by ultrasonics

An ultrasonic method was used to observe the onset of crack extension and to monitor continued crack growth in fracture toughness specimens during three-point bend tests. A 20-MHz transducer was used with commercially available equipment to detect average crack extension less than 0.09 mm. The material tested was a 300-grade maraging steel in the annealed condition. A crack extension resistance curve was developed to demonstrate the usefulness of the ultrasonic method for minimizing the number of tests required to generate such curves.

Klima, S. J.↗

The correlation of ultrasonic attenuation and shear strength in graphite-polyimide composites

The buffer rod technique for measuring attenuation in thin specimens is modified here to apply to specimens having intermediate thicknesses and high attenuation. The described procedure, which requires only one accessible surface of the material, was used to determine the initial attenuation values of ultrasonic waves in short beam shear specimens of graphite-polyimide composite material. It is shown that there is good correlation between the initial attenuation values and the shear strengths of the specimens determined by the standard short beam shear test method. The modified ultrasonic buffer block technique offers much potential for service as a quantitative, nondestructive, quality assurance test for composite materials.

Hayford, D. T.↗

General relationships between ultrasonic attenuation and dispersion

General relationships between the ultrasonic attenuation and dispersion are presented. The validity of these nonlocal relationships hinges only on the properties of causality and linearity, and does not depend upon details of the mechanism responsible for the attenuation and dispersion. Approximate, nearly local relationships are presented and are demonstrated to predict accurately the ultrasonic dispersion in solutions of hemoglobin from the results of attenuation measurements.

Odonnell, M.↗

Quantitative ultrasonic evaluation of mechanical properties of engineering materials

Current progress in the application of ultrasonic techniques to nondestructive measurement of mechanical strength properties of engineering materials is reviewed. Even where conventional NDE techniques have shown that a part is free of overt defects, advanced NDE techniques should be available to confirm the material properties assumed in the part's design. There are many instances where metallic, composite, or ceramic parts may be free of critical defects while still being susceptible to failure under design loads due to inadequate or degraded mechanical strength. This must be considered in any failure prevention scheme that relies on fracture analysis. This review will discuss the availability of ultrasonic methods that can be applied to actual parts to assess their potential susceptibility to failure under design conditions.

Vary, A.↗

Ultrasonic analysis of bolt preloads

This paper covers an investigation into the feasibility of analyzing bolt preloads by ultrasonic techniques. Various techniques were evaluated and a pulse echo inteferometric method was selected for experimental testing. In agreement with theoretical predictions, the interferometer response was found to be linearly related to tensile stresses oriented parallel to the bolt axis. Under rather idealized conditions, bolt loads can be determined with errors of less than 1%. The ultimate operational accuracy depends on a number of variables, such as bolt dimensions and geometry, bolt temperature, uniformity of stresses, and bolt materials, but load analyses to within + or - 3% are readily achievable. Best results are obtained with the ultrasonic transducer contact coupled to a small flat area near the center of the bolt head. The transducer can be applied and measurements made without interfering with normal wrenching operations. Prototype instrumentation is described and calibration results are tabulated for numerous bolt sizes and materials.

Rollins, F. R., Jr.↗

Use of an ultrasonic-acoustic technique for nondestructive evaluation of fiber composite strength

This report describes the ultrasonic-acoustic technique used to measure a 'Stress Wave Factor'. In a prior study this factor was found effective in evaluating the interlaminar shear strength of fiber-reinforced composites. Details of the method used to measure the stress wave factor are described. In addition, frequency spectra of the stress waves are analyzed in order to clarify the nature of the wave phenomena involved. The stress wave factor can be measured with simple contact probes requiring only one-side access to a part. This is beneficial in nondestructive evaluations because the waves can run parallel to fiber directions and thus measure material properties in directions assumed by actual loads. Moreover, the technique can be applied where conventional through transmission techniques are impractical or where more quantitative data are required. The stress wave factor was measured for a series of graphite/polyimide composite panels and results obtained are compared with through transmission immersion ultrasonic scans.

Vary, A.↗

Influence of phase cancellation and pulse shape artifacts on ultrasonic spectrum analysis

Both continuous wave and Fourier transformed pulse ultrasonic spectroscopy are being applied to material and flow characterization. Ideal samples and flaws (flat, parallel, and homogeneous) and ideal ultrasonic apparatus (producing delta function stress waves) provide acoustic spectra which can be partially inverted. However, in the presence of material inhomogeneity, lack of sample flatness or parallelism, or finite risetime pulses, the spectra become quite complex and produce phase cancellations at the transducer as well as pulse shape spectral artifacts. In this paper, we examine the nature of these artifacts for both simple and practical samples. Sample spectra are contrasted for several different transducer/electronic systems. Spectra obtained with a phase insensitive acousto-electric transducer (AET) combined with a frequency tracked tone-burst spectroscopy (TBS) method are presented. Analysis of the test configuration is shown to produce spectra consistent with that obtained with the AET-TBS combination.

Heyman, J. S.↗

CDS solid state phase insensitive ultrasonic transducer

A phase insensitive ultrasonic transducer which includes a CdS crystal that is annealed for a selected period of time and at a selected temperature to provide substantially maximum acoustic attenuation at the operating frequency of the transducer is described. Two electrodes are attached to the crystal with amplifier means and a signal processing system connected to one of the electrodes to provide an ultrasonic receiver.

Heyman, J. S.↗

Ultrasonic nondestructive evaluation of impact-damaged graphite fiber composite

Unidirectional Hercules AS/3501-6 graphite fiber epoxy composites were subjected to repeated controlled low-velocity drop weight impacts in the laminate direction. The degradation was ultrasonically monitored using through-thickness attenuation and a modified stress wave factor (SWF). There appears to be strong correlations between the number of drop-weight impacts, the residual tensile strength, the through-thickness attenuation, and the SWF. The results are very encouraging with respect to the NDE potential of both of these ultrasonic parameters to provide strength characterizations in virgin as well as impact-damaged fiber composite structures.

Williams, J. H., Jr.↗

An ultrasonic plethysmograph for space flight applications

The development of an ultrasonic plethysmograph based on the transit time measurement principle is reported, which meets the space-imposed requirements for evaluating cardiovascular deconditioning. It consists of a pulse generator, pulse receiver amplifier, voltage comparator, synchronous pulse generator, elapsed time counter, and transmit and receive piezoelectric crystals resonant at 2 MHz and of 3 mm diameter. The transit time for an ultrasonic pulse to propagate across a limb cross section is computed in a digital fashion using a 32 MHz clock, and resolution is 0.049 mm with the range being approximately 200 mm. Experimental results regarding dynamic system response were found comparable in both accuracy and sensitivity to those of a Whitney strain gage using a 50 torr venous occlusion.

Bhagat, P. K.↗