Search NASA⌕ Search

SEARCH · Search NASA

Results for “VAPOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A Portable Electronic Nose For Toxic Vapor Detection, Identification, and Quantification

A new prototype instrument based on electronic nose (e-nose) technology has demonstrated the ability to identify and quantify many vapors of interest to the Space Program at their minimum required concentrations for both single vapors and two-component vapor mixtures, and may easily be adapted to detect many other toxic vapors. To do this, it was necessary to develop algorithms to classify unknown vapors, recognize when a vapor is not any of the vapors of interest, and estimate the concentrations of the contaminants. This paper describes the design of the portable e-nose instrument, test equipment setup, test protocols, pattern recognition algorithms, concentration estimation methods, and laboratory test results.

Linnell, B. R.↗

Correlation among Cirrus Ice Content, Water Vapor and Temperature in the TTL as Observed by CALIPSO and Aura-MLS

Water vapor in the tropical tropopause layer (TTL) has a local radiative cooling effect. As a source for ice in cirrus clouds, however, it can also indirectly produce infrared heating. Using NASA A-Train satellite measurements of CALIPSO and Aura/MLS we calculated the correlation of water vapor, ice water content and temperature in the TTL. We find that temperature strongly controls water vapor (correlation r =0.94) and cirrus clouds at 100 hPa (r = −0.91). Moreover we observe that the cirrus seasonal cycle is highly (r =−0.9) anticorrelated with the water vapor variation in the TTL, showing higher cloud occurrence during December-January-February. We further investigate the anticorrelation on a regional scale and find that the strong anticorrelation occurs generally in the ITCZ (Intertropical Convergence Zone). The seasonal cycle of the cirrus ice water content is also highly anticorrelated to water vapor (r = −0.91) and our results support the hypothesis that the total water at 100 hPa is roughly constant. Temperature acts as a main regulator for balancing the partition between water vapor and cirrus clouds. Thus, to a large extent, the depleting water vapor in the TTL during DJF is a manifestation of cirrus formation.

Flury, T.↗

A New Technique for the Retrieval of Near Surface Water Vapor Using DIAL Measurements

Water vapor is one of the most important atmospheric trace gas species and influences radiation, climate, cloud formation, surface evaporation, precipitation, storm development, transport, dynamics, and chemistry. For improvements in NWP (numerical weather prediction) and climate studies, global water vapor measurements with higher accuracy and vertical resolution are needed than are currently available. Current satellite sensors are challenged to characterize the content and distribution of water vapor in the Boundary Layer (BL) and particularly near the first few hundred meters above the surface within the BL. These measurements are critically needed to infer surface evaporation rates in cloud formation and climate studies. The NASA Langley Research Center Lidar Atmospheric Sensing Experiment (LASE) system, which uses the Differential Absorption Lidar (DIAL) technique, has demonstrated the capability to provide high quality water vapor measurements in the BL and across the troposphere. A new retrieval technique is investigated to extend these DIAL water vapor measurements to the surface. This method uses signals from both atmospheric backscattering and the strong surface returns (even over low reflectivity oceanic surfaces) using multiple gain channels to cover the large signal dynamic range. Measurements can be made between broken clouds and in presence of optically thin cirrus. Examples of LASE measurements from a variety of conditions encountered during NASA hurricane field experiments over the Atlantic Ocean are presented. Comparisons of retrieved water vapor profiles from LASE near the surface with dropsonde measurements show very good agreement. This presentation also includes a discussion of the feasibility of developing space-based DIAL capability for high resolution water vapor measurements in the BL and above and an assessment of the technology needed for developing this capability.

Ismail, Syed↗

Retrieval of Water Vapor Column Abundance and Aerosol Properties from ChemCam Passive Sky Spectroscopy

We derive water vapor column abundances and aerosol properties from Mars Science Laboratory (MSL) ChemCam passive mode observations of scattered sky light. This paper covers the methodology and initial results for water vapor and also provides preliminary results for aerosols. The data set presented here includes the results of 113 observations spanning from Mars Year 31 L(s) = 291 deg (March 30, 2013) to Mars Year 33 L(s) = 127 deg (March 24, 2016). Each ChemCam passive sky observation acquires spectra at two different elevation angles. We fit these spectra with a discrete-ordinates multiple scattering radiative transfer model, using the correlated-k approximation for gas absorption bands. The retrieval proceeds by first fitting the continuum of the ratio of the two elevation angles to solve for aerosol properties, and then fitting the continuum-removed ratio to solve for gas abundances. The final step of the retrieval makes use of the observed CO 2 absorptions and the known CO 2 abundance to correct the retrieved water vapor abundance for the effects of the vertical distribution of scattering aerosols and to derive an aerosol scale height parameter. Our water vapor results give water vapor column abundance with a precision of +/-0.6 precipitable microns and systematic errors no larger than +/-0.3 precipitable microns, assuming uniform vertical mixing. The ChemCam-retrieved water abundances show, with only a few exceptions, the same seasonal behavior and the same timing of seasonal minima and maxima as the TES, CRISM, and REMS-H data sets that we compare them to. However ChemCam-retrieved water abundances are generally lower than zonal and regional scale from-orbit water vapor data, while at the same time being significantly larger than pre-dawn REMS-H abundances. Pending further analysis of REMS-H volume mixing ratio uncertainties, the differences between ChemCam and REMS-H pre-dawn mixing ratios appear to be much too large to be explained by large scale circulations and thus they tend to support the hypothesis of substantial diurnal interactions of water vapor with the surface. Our preliminary aerosol results, meanwhile, show the expected seasonal pattern in dust particle size but also indicate a surprising interannual increase in water-ice cloud opacities.

Mcconnochie, Timothy H.↗

Understanding the Water Cycle Above the North Polar Cap on Mars Using MRO CRISM Retrievals of Water Vapor

The north polar cap (NPC) on Mars is the major reservoir of atmospheric water (H2O) currently on Mars. The retrieval and monitoring of atmospheric water vapor abundance are crucial for tracking the cycle of water above the NPC. The Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) aboard the Mars Reconnaissance Orbiter (MRO) has provided a wealth of data that extend over 5 + Martian years, covering the time period between 2006 and 2016. CRISM is ideally suited for spring and summer observations of the north polar region (latitudes poleward of 60 °N). The retrievals of water vapor column abundances over this extended period of time were performed over both ice-free and water ice covered surfaces, extending the coverage of the water vapor maps to include the permanent cap, where a maximum value of 90 precipitable micrometers (pr–µm) is retrieved, as compared to 60 pr–µm over ice-free regions in the North Polar Region. Away from summertime maximum, modest interannual variability in the water vapor abundance is observed. Zonal averages over all the observed Martian years combined show a developing water front that shifts northward towards summer, before dissipating over the permanent cap during mid-summer. A prominent feature at latitudes around 75 °N shows large abundances of water vapor, indicating a water vapor annulus encircling the retreating edge of the seasonal polar cap during late spring. Meridional transport of water modeled here show that the annulus may be a result of the convergence of water vapor from both south and north along the retreating edge of the NPC.

Khayat, Alain S. J.↗

Variability of Water Vapor in the Tropical Middle Atmosphere Observed From Satellites and Interpreted Using SD-WACCM Simulations

Water vapor in the middle atmosphere plays an essential role in global warming, ozone depletion, and the formation of polar stratospheric and mesospheric clouds. We show that tropical middle atmospheric water vapor simulated with the specified-dynamics version of the Whole Atmosphere Community Climate Model (SD-WACCM) is consistent with changes observed in a merged satellite data set, which encompasses the period 1993–2020. Consistent with previous work, we find no significant trend in the stratosphere in either the observations or the simulation; in the mesosphere, we find a long-term trend of 0.1 ppmv per decade, but only in the observations. We also analyze an SD-WACCM simulation for the longer period 1980–2019 to quantify the contribution of various factors to the decadal variation of middle atmospheric water vapor. Over 1980–1995, the simulated water vapor in the upper stratosphere and mesosphere, averaged zonally and over ±30° latitude, increases by 0.30 ppmv per decade due to increasing methane emissions. After 1995, a significant abrupt decrease of water vapor of 0.37 ppmv per decade and then a gradual increase of 0.33 ppmv per decade result from changes in stratospheric cold point temperature. The cold-point temperature is strongly influenced by the strength of the Brewer-Dobson circulation. The acceleration of the Brewer-Dobson circulation before about 2003 leads to a cooler tropical tropopause and a decrease of water vapor, and the deceleration thereafter leads to corresponding warming of the tropopause and an increase in water vapor.

Wandi Yu↗

The Relationship Between Volatile Element Abundances and Iron Carrying Capacity in Lunar Volcanic and Impact Vapors

The highly volatile elements (e.g. H, C, S, Cl) released during lunar volcanism provide important insights into the bulk volatile composition of the Moon. Once erupted, some fraction of the species containing these elements may have migrated to the poles where they could have become sequestered in shadowed cold traps such as those found near the lunar South pole. The volatiles trapped in the lunar South pole are of great interest to the upcoming Artemis missions, which will be operating nearby and could sample some of those materials. Volcanic vapor deposits in the polar regions might also be supplemented by volatiles from other sources both exogenous (i.e. comets) and endogenous (i.e. remobilization of lunar volatiles by impact). Characterizing these endogenous sources is challenging because the highly volatile elements often leave little trace behind in the rocks themselves, which are inherently refractory by nature. Minerals are found on vug, vesicle, or fracture surfaces that have characteristics consistent with phases formed via direct deposition of a vapor, as opposed to crystallization from a liquid or via solid state decomposition. One common vapor-deposited species is metallic Fe, typically observed as subhedral to euhedral crystals found on vug or vesicle walls in mare basalts and on select breccia clast surfaces in regolith soil samples returned from the Moon. A particularly striking example is seen below in Fig. 1, where numerous Fe crystals are deposited onto the wall of a vug in Apollo 17 basalt sample 71036. Euhedral Fe crystals are not very common in Apollo breccia samples, though this may be from the limited number of systematic searches that have been performed. However, when Fe crystals are found, they can occur in extremely high abundance(e.g., sample 15402 which was specifically selected because of its numerous Fe crystals, was found to have a clast with 477 euhedral Fe crystals in a 570 x 570 μm area). What struck us as interesting about this was not only that it takes a large amount of Fe to make these crystal-rich deposits, but also that these crystal-rich deposits are not ubiquitous, and therefore they must be controlled by some aspect of their depositional conditions that varies. Since those conditions are inherently difficult to investigate and are critically interesting, we used thermochemical modeling as a tool to investigate the relationship between vapor-deposited Fe and various intensive and extensive parameters. We assumed that a high abundance of Fe in the vapor is required to form these crystals, thus the mass of Fe in the vapor was used to determine the plausibility of the vapor-deposited, euhedral Fe crystals observed in Apollo samples.

thermodynamics↗

Vapor-Particle Separation Using Microporous Metallic Membrane in Crossflow Filtration

Simultaneous separation of vapor and particles in industrial processes could be a key step toward manufacturing of high-quality goods. The separation is critical for successful measurement of volatile or semi-volatile aerosol particles, which no reliable technique exists. We have developed a technique for separation of vapor and particles simultaneously using a specialty microporous metallic membrane. The separator allows the thermally denuded particles traverse straight through the membrane tube, while the vapor molecules permeate through the membrane, separate from the particles and are removed subsequently. The separation technique virtually eliminates the possibility of contamination by vapor re- condensation. We tested the prototype of the vapor-particle separator (VPS) using aerosols prepared from sodium chloride to represent non-volatile aerosols. Chemical like dioctyl phthalate was chosen to represent volatile particles. The test aerosol particles were generated by an atomizer followed by a tandem differential mobility analyser to produce a stream of monodisperse particles in the size range of 10 to 100 nm. In real world particles, we tested the VPS using diesel engine particles that is a mixture of complex chemical composition. Number concentration of the nonvolatile particles reduced as the temperature increased, but the mode diameter of the aerosol population remained unchanged. Number concentration of the volatile particles was also reduced as the temperature increased, but their mode diameters became smaller as particles shrunk in diameter. Differences in the thermal behaviour of the particles were attributed to its transition energy barrier and evaporation rate. Mass balance analysis suggests the separation of vapor and test particles was reasonably complete. Thus, we conclude the VPS could provide an effective means for quantitative characterization of aerosol volatility and separation of vapors from particles.

aerosol↗

Method for using a hydrocyclone for cryogenic gas vapor separation

A method for separating a vapor from a carrier gas is disclosed. A hydrocyclone is provided with one or more nozzles on the wall of the hydrocyclone. A cryogenic liquid is provided to the tangential feed inlet at a velocity that induces a tangential flow and a cyclone vortex in the hydrocyclone. The carrier gas is injected into the hydrocyclone through the one or more nozzles. The vapor dissolves, condenses, desublimates, or a combination thereof, forming a vapor-depleted carrier gas and a vapor-enriched cryogenic liquid. The vapor-depleted gas is drawn through the vortex finder while the vapor-enriched cryogenic liquid is drawn through the apex nozzle outlet. In this manner, the vapor is removed from the carrier gas.

42 ENGINEERING↗

Method for using an air-sparged hydrocyclone for cryogenic gas vapor separation

A method for separating a vapor from a carrier gas is disclosed. An air-sparged hydrocyclone is provided with a porous sparger covered by an outer gas plenum. A cryogenic liquid is provided to the tangential feed inlet at a velocity that induces a tangential flow and a cyclone vortex in the cyclone. The carrier gas is injected into the air-sparged hydrocyclone through the porous sparger. The vapor dissolves, condenses, desublimates, or a combination thereof, forming a vapor-depleted carrier gas and a vapor-enriched cryogenic liquid. The vapor-depleted gas is drawn through a vortex finder while the vapor-enriched cryogenic liquid is drawn through an apex nozzle outlet. In this manner, the vapor is removed from the carrier gas.

Baxter, Larry↗

Hydrocyclone for cryogenic gas-vapor separation

A hydrocyclone for separating a vapor from a carrier gas is disclosed. The hydrocyclone comprises one or more nozzles. A cryogenic liquid is injected to a tangential feed inlet at a velocity that induces a tangential flow and a cyclone vortex in the hydrocyclone. The carrier gas is injected into the cryogenic liquid, causing the vapor to dissolve, condense, desublimate, or a combination thereof, forming a vapor-depleted carrier gas and a vapor-enriched cryogenic liquid. The vapor-depleted carrier gas is drawn through a vortex finder and the vapor-enriched cryogenic liquid is drawn through an apex nozzle outlet. In this manner, the vapor is removed from the carrier gas.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Air-sparged hydrocyclone for cryogenic gas vapor separation

An air-sparged hydrocyclone for separating a vapor from a carrier gas is disclosed. The cyclone comprises a porous sparger covered by an outer gas plenum. A cryogenic liquid is injected to a tangential feed inlet at a velocity that induces a tangential flow and a cyclone vortex in the air-sparged hydrocyclone. The carrier gas is injected into the cyclone through the porous sparger. The vapor dissolves, condenses, desublimates, or a combination thereof, forming a vapor-depleted carrier gas and a vapor-enriched cryogenic liquid. The vapor-depleted carrier gas is drawn through a vortex finder and the vapor-enriched cryogenic liquid is drawn through an apex nozzle outlet. In this manner, the vapor is removed from the carrier gas.

Baxter, Larry↗

Microstructure of vapor deposited coatings on curved substrates

Thermal barrier coating systems consisting of a metallic bond coat and ceramic over layer are widely used to extend the life of gas turbine engine components. They are applied using either high-vacuum physical vapor deposition techniques in which vapor atoms rarely experience scattering collisions during propagation to a substrate, or by gas jet assisted (low-vacuum) vapor deposition techniques that utilize scattering from streamlines to enable non-line-of-sight deposition. Both approaches require substrate motion to coat a substrate of complex shape. Here, direct simulation Monte Carlo and kinetic Monte Carlo simulation methods are combined to simulate the deposition of a nickel coating over the concave and convex surfaces of a model airfoil, and the simulation results are compared with those from experimental depositions. The simulation method successfully predicted variations in coating thickness, columnar growth angle, and porosity during both stationary and substrate rotated deposition. It was then used to investigate a wide range of vapor deposition conditions spanning high-vacuum physical vapor deposition to low-vacuum gas jet assisted vapor deposition. The average coating thickness was found to increase initially with gas pressure reaching a maximum at a chamber pressure of 8–10 Pa, but the best coating thickness uniformity was achieved under high vacuum deposition conditions. However, high vacuum conditions increased the variation in the coatings pore volume fraction over the surface of the airfoil. The simulation approach was combined with an optimization algorithm and used to investigate novel deposition concepts to tailor the local coating thickness.

42 ENGINEERING↗

Experimental and Modeling Study of the Flammability of Fuel Tank Headspace Vapors from Ethanol/Gasoline Fuels; Phase 3: Effects of Winter Gasoline Volatility and Ethanol Content on Blend Flammability; Flammability Limits of Denatured Ethanol

This study assessed differences in headspace flammability for summertime gasolines and new high-ethanol content fuel blends. The results apply to vehicle fuel tanks and underground storage tanks. Ambient temperature and fuel formulation effects on headspace vapor flammability of ethanol/gasoline blends were evaluated. Depending on the degree of tank filling, fuel type, and ambient temperature,fuel vapors in a tank can be flammable or non-flammable. Pure gasoline vapors in tanks generally are too rich to be flammable unless ambient temperatures are extremely low. High percentages of ethanol blended with gasoline can be less volatile than pure gasoline and can produce flammable headspace vapors at common ambient temperatures. The study supports refinements of fuel ethanol volatilityspecifications and shows potential consequences of using noncompliant fuels. E85 is flammable at low temperatures; denatured ethanol is flammable at warmer temperatures. If both are stored at the same location, one or both of the tanks' headspace vapors will be flammable over a wide range of ambient temperatures. This is relevant to allowing consumers to splash -blend ethanol and gasoline atfueling stations. Fuels compliant with ASTM volatility specifications are relatively safe, but the E85 samples tested indicate that some ethanol fuels may produce flammable vapors.

02 PETROLEUM↗

Bench Scale Study of Coating Formulations for Abatement of Mercury Vapor and Recovery of Mercury Spills

A sealant formulation has been developed that effectively mitigates human exposure to elemental mercury vapor evolving from spilled mercury. The sealant may be dispensed using a fogging methodology (for industrial settings) or a common spray bottle (for home or school settings). In parallel, the potential for Hg recovery using strippable coatings was evaluated. Four liquid coatings were evaluated: one fogging fixative (FX2) developed at INL for the containment of surface and airborne contamination and three commercially available strippable decontamination gels (Carboset 441, Encor 449, and Stripcoat TLC Free). Bench scale mercury vapor abatement tests were conducted in an enclosure using FX2 with the addition of a mercury absorbent and a mercury reactant. Testing with FX2 showed the reactant contributed significantly to reducing the rate of mercury evaporation. The reactant had a minimal impact on the mercury evaporation rate for the strippable coatings. The potential of strippable coatings to remove/recover mercury was inferred from the adhesive and cohesive performance of sprayable dilutions of the coatings applied to porous and non-porous surfaces. Testing provided the following results: • Mercury vapor concentration was reduced by a factor of 40 using the reactant enhanced FX2 solution, as well as with dilutions of Carboset and Encor. Dilute Stripcoat was less effective at reducing Hg evaporation. • A 100× reduction in Hg evaporation rate was achieved using a coating of FX + the Hg reactant (a.k.a. FX Hg), compared to uncoated Hg. • A 2× reduction in the Hg vapor accumulation rate was achieved using FX Hg, compared to the strippable coatings. • Strippability and adhesion tests show that dilutions of Carboset and Stripcoat can be stripped from a variety of indoor surfaces. Dilute Encor was not strippable. Results suggest FX Hg and dilute Carboset will likely reduce Hg vapor concentrations, in an indoor setting, to a level at or below the Occupational Safety and Health Administration 8-hour human exposure limit (0.1 mg/m3). FX Hg dispensed via fogging would increase worker safety during remediation and demolition of industrial facilities with high levels of elemental mercury contamination. When applied via spray bottle, FX Hg may provide a safe and convenient method for the mitigation of Hg vapor in residential or commercial settings (e.g., offices, homes, schools). This approach would be most beneficial where recovery of the spilled Hg is impractical. A sprayed then stripped application of dilute Carboset may provide a safe and convenient method for recovery of small Hg spills in residential and commercial settings. Further testing is required to determine if liquid Hg sufficiently adheres to the strippable coating to be recovered in this way. If it can be dispensed as a fog, dilute Carboset could be employed to recover Hg contamination in industrial settings. Testing of the foggability of dilute Carboset is required to assess this potential.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation of a Multiphase Computational Fluid Dynamics Model for Vapor Pull-Through in Normal and Low Gravity

On-orbit fluid transfer such as refueling of propellant tanks and life-support systems can enable long-duration space missions. For safe and efficient liquid transfer operations, prior knowledge of liquid positioning and liquid-vapor interface behavior while draining in a low-gravity environment is required. Numerical models capable of predicting vapor ingestion (or vapor pull-through) can be used to design liquid transfer operations while reducing liquid residuals, mission risk and settling thrust required to prevent vapor ingestion. An experimental program conducted in the 2.2 Second Drop Tower facility at NASA Glenn Research Center investigated the vapor ingestion phenomenon for a range of outflow rates and tank sizes providing a database for validation. This study presents a Computational Fluid Dynamics model capable of accurately predicting the vapor ingestion using the Volume-of-Fluid multiphase solver in commercial code STAR-CCM+. A description of the experimental setup and general trends from similar studies are presented. Comparisons of the numerical prediction and test data in normal and low gravity show good agreement and give confidence in pursuing design of full-scale propellant transfer systems.

Computational Fluid Dynamics↗

Validation of a Multiphase Computational Fluid Dynamics Model for Vapor Pull-Through in Normal and Low Gravity

On-orbit fluid transfer such as refueling of propellant tanks and life-support systems can enable long-duration space missions. For safe and efficient liquid transfer operations, prior knowledge of liquid positioning and liquid-vapor interface behavior while draining in a reduced-gravity environment is required. Numerical models capable of predicting vapor ingestion (or vapor pull-through) can be used to design liquid transfer operations while reducing liquid residuals, mission risk and settling thrust required to prevent vapor ingestion. An experimental program conducted in the 2.2 Second Drop Tower facility at NASA Lewis Research Center in 1969 investigated the vapor ingestion phenomenon for a range of outflow rates and tank sizes providing a database for validation. This study presents a Computational Fluid Dynamics model capable of accurately predicting the vapor ingestion using the Volume-of-Fluid multiphase solver in commercial code STAR-CCM+. A description of the experimental setup and general trends from similar studies are presented. Comparisons of the numerical prediction and test data in normal and low gravity show good agreement and give confidence in pursuing design of full-scale propellant transfer systems.

Computational Fluid Dynamics↗

Validation of A Multiphase Computational Fluid Dynamics Model for Vapor Pull-Through in Normal and Low Gravity

On-orbit fluid transfer such as refueling of propellant tanks and life-support systems can enable long-duration space missions. For safe and efficient liquid transfer operations, prior knowledge of liquid positioning and liquid-vapor interface behavior while draining in a reduced-gravity environment is required. Numerical models capable of predicting vapor ingestion (or vapor pull-through) can be used to design liquid transfer operations while reducing liquid residuals, mission risk and settling thrust required to prevent vapor ingestion. An experimental program conducted in the 2.2 Second Drop Tower facility at NASA Lewis Research Center in 1969 investigated the vapor ingestion phenomenon for a range of outflow rates and tank sizes providing a database for validation. This study presents a Computational Fluid Dynamics model capable of accurately predicting the vapor ingestion using the Volume-of-Fluid multiphase solver in commercial code STAR-CCM+. A description of the experimental setup and general trends from similar studies are presented. Comparisons of the numerical prediction and test data in normal and low gravity show good agreement and give confidence in pursuing design of full-scale propellant transfer systems.

Propellant Transfer↗