Search NASA⌕ Search

SEARCH · Search NASA

Results for “VAPOR, WATER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Influence of Local Water Vapor Analysis Uncertainty on Ensemble Forecasts of Tropical Cyclogenesis Using Hurricane Irma (2017) as a Testbed

Abstract Tropical cyclone formation is known to require abundant water vapor in the lower to middle troposphere within the incipient disturbance. In this study, we assess the impacts of local water vapor analysis uncertainty on the predictability of the formation of Hurricane Irma (2017). To this end, we reduce the magnitude of the incipient disturbance’s water vapor perturbations obtained from an ensemble-based data assimilation system that constrained moisture by assimilating all-sky infrared and microwave radiances. Five-day ensemble forecasts are initialized two days before genesis using each set of modified analysis perturbations. Growth of convective differences and intensity uncertainty are evaluated for each ensemble forecast. We observe that when initializing an ensemble forecast with only moisture uncertainty within the incipient disturbance, the resulting intensity uncertainty at every lead time exceeds half that of an ensemble containing initial perturbations to all variables throughout the domain. Although ensembles with different initial moisture uncertainty amplitudes reveal a similar pathway to genesis, uncertainty in genesis timing varies substantially across ensembles since moister members exhibit earlier spinup of the low-level vortex. These differences in genesis timing are traced back to the first 6–12 h of integration, when differences in the position and intensity of mesoscale convective systems across ensemble members develop more quickly with greater initial moisture uncertainty. In addition, the rapid growth of intensity uncertainty may be greatly modulated by the diurnal cycle. Ultimately, this study underscores the importance of targeting the incipient disturbance with high spatiotemporal water vapor observations for ingestion into data assimilation systems. Significance Statement Hurricanes form from clusters of thunderstorms that organize into a coherent system. One of the key ingredients for the formation process is an abundance of moisture. In this study, we test the sensitivity of hurricane formation to the initial moisture content in the vicinity of the cluster of thunderstorms that would become Hurricane Irma (2017). To do so, we initialize sets of forecasts each having a different variability of initial moisture content within the embryonic disturbance. Our results show that the predictability of hurricane formation is highly dependent on the uncertainty of the moisture content within the initial disturbance. Consequently, more high-quality observations of the moisture within the precursor disturbances to hurricanes are expected to improve forecasts of their formation.

Hartman, Christopher M.↗

Dropsonde Observations of Total Integrated Water Vapor Transport within North Pacific Atmospheric Rivers

A0.0ircraft dropsonde observations provide the most comprehensive measurements to date of horizontal water vapor transport in atmospheric rivers (AR). The CalWater experimen0 t 0.0recently more than tripled the number of ARs probed with the required measurements. This study uses vertical profiles of water vapor, wind, and pressure obtained from 304 dropsondes across 21 ARs. On average, total water vapor transport (TIVT) in an AR was 4.7108 2108 kg s-1. This magnitude is 2.6 times larger than the average discharge of liquid water from the Amazon River. The mean AR width was 890 270 km. Subtropical ARs contained larger IWV but weaker winds than midlatitude ARs, although average TIVTs were nearly the same. Mean TIVTs calculated by defining the lateral edges of ARs using an IVT-threshold versus an IWV-threshold produced results that differed by less than 10 across all cases, but did vary between midlatitudes and subtropical regions.

water vapor↗

Observation of Mountain Lee Waves with MODIS NIR Column Water Vapor

Mountain lee waves have been previously observed in data from the Moderate Resolution Imaging Spectroradiometer (MODIS) "water vapor" 6.7 micrometers channel which has a typical peak sensitivity at 550 hPa in the free troposphere. This paper reports the first observation of mountain waves generated by the Appalachian Mountains in the MODIS total column water vapor (CWV) product derived from near-infrared (NIR) (0.94 micrometers) measurements, which indicate perturbations very close to the surface. The CWV waves are usually observed during spring and late fall or some summer days with low to moderate CWV (below is approx. 2 cm). The observed lee waves display wavelengths from3-4 to 15kmwith an amplitude of variation often comparable to is approx. 50-70% of the total CWV. Since the bulk of atmospheric water vapor is confined to the boundary layer, this indicates that the impact of thesewaves extends deep into the boundary layer, and these may be the lowest level signatures of mountain lee waves presently detected by remote sensing over the land.

satellite remote sensing↗

Water Vapor Tacers as Diagnostics of the Regional Atmospheric Hydrologic Cycle

Understanding of the local and remote sources of water vapor can be a valuable diagnostic in understanding the regional atmospheric hydrologic cycle, especially in North America where moisture transport and local evaporation are important sources of water for precipitation. In the present study, we have implemented passive tracers as prognostic variables to follow water vapor evaporated in predetermined regions until the water tracer precipitates. All evaporative sources of water are accounted for by tracers, and the water vapor variable provides the validation of the tracer water and the formulation of the sources and sinks. The Geostationary Operational Environmental Satellites General Circulation Model (GEOS GCM) is used to simulate several summer periods to determine the source regions of precipitation for the United States and India. Using this methodology, a detailed analysis of the recycling of water, interannual variability of the sources of water and links to the Great Plains low-level jet and North American monsoon will be presented. Potential uses in GCM sensitivity studies, predictability studies and data assimilation especially regarding the North American monsoon and GEWEX America Prediction Project (GAPP) will be discussed.

Bosilovich, Michael G.↗

Removal of water vapor from streams containing carbon dioxide and/or carbon monoxide

Methods and systems for removing water vapor from a feed gas prior to further processing the feed gas according to a downstream PSA process are described. The feed gas can include CO2 and/or CO and/or H2 and the PSA process can be used to separate components of the feed gas from one another, for instance, for CO2 capture. Light product off of the PSA process is utilized to regenerate desiccant of a dryer used in the water vapor removal process that is carried out prior to the feed gas entering the PSA process. The water vapor removal process can be heated by providing thermal energy directly to the dryer and/or to a regenerating stream that regenerates the desiccant of the dryer. The thermal energy can be low cost energy—for instance, waste heat off of a system that provides the feed gas.

Ritter, James A.↗

Study of the 10 micron continuum of water vapor

Radiation attenuation by atmospheric water vapor is considered. A formula based on laboratory data is recommended for approximating continuous absorption in the spectra region in question. Data of full scale measurements and laboratory experiments are compared. It was concluded that only molecular absorption need be taken into account under clear atmospheric conditions during the warm part of the year, while in winter or in cloudy conditions, the effect of aerosol can be significant.

Arefyev, V. N.↗

Preliminary endurance tests of water vaporizers for resistojet applications

Three water vaporizers designed for resistojet applications were built and tested for periods up to 500 h and 250 thermal cycles. Two of the vaporizers were not sensitive to orientation with respect to gravity, an indication of likely compatibility with low-gravity environments. Some temperatures and pressures in the third were impacted by orientation, although operation was always stable. The pressure drop across the sand-filled version increased by 147 percent in 38 h and 19 thermal cycles. Bonding of the sand granules in the downstream end of the heat exchanger was the suspected cause of failure of this vaporizer. Pressure drops across the two sintered stainless steel-filled versions were more gradual. One, with a pore size of 60 microns, showed an 80 percent increase in 500 h and 250 thermal cycles and another, with a 10 microns poresize, showed a 29 percent increase in 350 h and 175 thermal cycles. Testing of the latter metal-filled vaporizer was ongoing as of this writing. Oxidation of the porous metal packing materials in these vaporizers, with subsequent deposition of oxide particles within the pores, was believed to have caused the observed increases in pressure drops.

Morren, W. Earl↗

Preliminary endurance tests of water vaporizers for resistojet applications

Three water vaporizers designed for resistojet applications were built and tested for periods up to 500 h and 250 thermal cycles. Two of the vaporizers were not sensitive to orientation with respect to gravity, an indication of likely compatibility with low-gravity environments. Some temperatures and pressures in the third were impacted by orientation, although operation was always stable. The pressure drop across the sand-filled version increased by 147 percent in 38 h and 19 thermal cycles. Bonding of the sand granules in the downstream end of the heat exchanger was the suspected cause of failure of this vaporizer. Pressure drops across the two sintered stainless steel-filled versions were more gradual. One, with a pore size of 60 microns, showed an 80 percent increase in 500 h and 250 thermal cycles and another, with a 10 microns poresize, showed a 29 percent increase in 350 h and 175 thermal cycles. Testing of the latter metal-filled vaporizer was ongoing as of this writing. Oxidation of the porous metal packing materials in these vaporizers, with subsequent deposition of oxide particles within the pores, was believed to have caused the observed increases in pressure drops.

Morren, W. E.↗

A Demonstration of Precise Calibration of Tropospheric Delay Fluctuations with Water Vapor Radiometers

The ability of water vapor radiometers (WVRs) to calibrate changes in tropospheric delay was demonstrated during very long baseline radio interferometer (VLBI) observations at Goldstone, California. WVR measurements reduced the observed VLBI delay variations over a 13 hr period by a factor of approx. = 2.5. When applied to shorter time scales, a approx. = 50% reduction in 100-700 s delay variations was achieved during conditions of high tropospheric activity. Thermal WVR noise precluded calibration of short time scale delay fluctuations during quiet tropospheric conditions.

Teitelbaum, L. P.↗

Water Vapor Intercomparisons TES - AIRS - AMSR

Water vapor intercomparisons using Tropospheric Emission Spectrometer (TES), Atmospheric Infrared Sounder (AIRS) and Advanced Microwave Scanning Radiometer (AMSR) radiances are presented.

global surveys↗

Ground-based lidar measurements of ozone, water vapor and aerosols in the lower stratosphere and troposphere

Lidar measurements of ozone and water vapor concentrations were performed during several field experiments in 1980-1981 by means of the differential absorption laser technique. Profiles up to 26 km for ozone and up to 9 km for water vapor are presented. Also, a lidar survey of aerosol layers ranging from 12 to 23 km were performed following the Mt. St. Helens major eruption (May 1980). Experiments were conducted at the CNRS lidar facility of the Haute Provence Observatory which is located in southern France (44 deg N, 5 deg E). For ozone a vertical profile is recorded in three sequences, each requiring 15 min of acquisition time. The relative accuracy is better than 5 percent at the lower altitude and falls to 20 percent at 25 km. For water vapor the time sequences are 4 min or 8 min long and the accuracy is better than 10 percent in the lower troposphere.

Flamant, P. H.↗

Column Closure Studies of Lower Tropospheric Aerosol and Water Vapor During ACE-Asia Using Airborne Sunphotometer, Airborne In-Situ and Ship-Based Lidar Measurements

We assess the consistency (closure) between solar beam attenuation by aerosols and water vapor measured by airborne sunphotometry and derived from airborne in-situ, and ship-based lidar measurements during the April 2001 Asian Pacific Regional Aerosol Characterization Experiment (ACE-Asia). The airborne data presented here were obtained aboard the Twin Otter aircraft. Comparing aerosol extinction o(550 nm) from four different techniques shows good agreement for the vertical distribution of aerosol layers. However, the level of agreement in absolute magnitude of the derived aerosol extinction varied among the aerosol layers sampled. The sigma(550 nm) computed from airborne in-situ size distribution and composition measurements shows good agreement with airborne sunphotometry in the marine boundary layer but is considerably lower in layers dominated by dust if the particles are assumed to be spherical. The sigma(550 nm) from airborne in-situ scattering and absorption measurements are about approx. 13% lower than those obtained from airborne sunphotometry during 14 vertical profiles. Combining lidar and the airborne sunphotometer measurements reveals the prevalence of dust layers at altitudes up to 10 km with layer aerosol optical depth (from 3.5 to 10 km altitude) of approx. 0.1 to 0.2 (500 nm) and extinction-to-backscatter ratios of 59-71 sr (523 nm). The airborne sunphotometer aboard the Twin Otter reveals a relatively dry atmosphere during ACE- Asia with all water vapor columns less than 1.5 cm and water vapor densities w less than 12 g/cu m. Comparing layer water vapor amounts and w from the airborne sunphotometer to the same quantities measured with aircraft in-situ sensors leads to a high correlation (r(sup 3)=0.96) but the sunphotometer tends to underestimate w by 7%.

Schmid, B.↗

Retrieval of water vapor profiles from microwave radiometric measurements near 90 and 183 GHz

Upwelling radiometric measurements at 90 GHz and three side bands near 183 GHz are used to retrieve water vapor profiles over the ocean surface. An algorithm incorporating a new technique of handling moderate cloud cover is illustrated for the profiling of both relative humidity and water vapor burden. It is shown that the retrieved relative humidity profiles reflect gross features of the corresponding profiles recorded by the radiosondes. However, the retrieval generally cannot produce fine details of the observed profiles at altitudes where a rapid change in relative humidity occurs. For this reason, comparison of retrieved and observed values at a given altitude often yields an appreciable rms error. Profiling of water vapor burden, a parameter equivalent to total integrated water vapor above a certain altitude, results in much better agreement, as expected. The rms error obtained from the results of the retrieval at the surface is comparable to that derived from the combination of measurements at 18 GHz and 21 GHz channels of the Scanning Multichannel Microwave Radiometer aboard the Nimbus 7 satellite.

Wang, J. R.↗

Annual variations of water vapor in the stratosphere and upper troposphere observed by the Stratospheric Aerosol and Gas Experiment II

Data collected by the Stratospheric Aerosol and Gas Experiment II are presented, showing annual variations of water vapor in the stratosphere and the upper troposphere. The altitude-time cross sections of water vapor were found to exhibit annually repeatable patterns in both hemispheres, with a yearly minimum in water vapor appearing in both hemispheres at about the same time, supporting the concept of a common source for stratospheric dry air. A linear regression analysis was applied to the three-year data set to elucidate global values and variations of water vapor ratio.

Mccormick, M. P.↗

Water vapor as an error source in microwave geodetic systems: Background and survey of calibration techniques

Water vapor as an error source in radio interferometry systems is briefly examined. At microwave frequencies, the delay imposed by tropospheric water vapor becomes a limiting error source for high accuracy geodetic systems. The mapping of tropospheric induced errors into 'solved-for' parameters depends upon baseline length and observing strategy. Simulation analysis (and experience) indicates that in some cases, errors in estimating tropospheric delay can be magnified in their effect on baseline components. The various techniques by which tropospheric water can be estimated or measured are surveyed with particular consideration to their possible use as a calibration technique in support to very long baseline interferometry experiments. The method of remote sensing using a microwave radiometer seems to be the most effective way to provide an accurate estimate of water vapor delay.

Claflin, E. S.↗

Water vapor differential absorption lidar development and evaluation

A ground-based differential absorption lidar (DIAL) system is described which has been developed for vertical range-resolved measurements of water vapor. The laser transmitter consists of a ruby-pumped dye laser, which is operated on a water vapor absorption line at 724.372 nm. Part of the ruby laser output is transmitted simultaneously with the dye laser output to determine atmospheric scattering and attenuation characteristics. The dye and ruby laser backscattered light is collected by a 0.5-m diam telescope, optically separated in the receiver package, and independently detected using photomultiplier tubes. Measurements of vertical water vapor concentration profiles using the DIAL system at night are discussed, and comparisons are made between the water vapor DIAL measurements and data obtained from locally launched rawinsondes. Agreement between these measurements was found to be within the uncertainty of the rawinsonde data to an altitude of 3 km. Theoretical simulations of this measurement were found to give reasonably accurate predictions of the random error of the DIAL measurements. Confidence in these calculations will permit the design of aircraft and Shuttle DIAL systems and experiments using simulation results as the basis for defining lidar system performance requirements

Browell, E. V.↗