Search NASA⌕ Search

SEARCH · Search NASA

Results for “VASCULAR DISEASES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Long-Term Results of Stent Placement in Patients with Outflow Block After Living-Donor-Liver Transplantation

PurposeTo evaluate long-term results of stent placement retrospectively in patients with outflow block after living-donor-liver transplantation (LDLT).Materials and MethodsFor this institutional review board approved retrospective study conducted during 2002–2012, stents were placed in outflow veins in 15 patients (11.3 %, 15/133) (12 men; 3 female) in whom outflow block developed after LDLT. Their mean age was 52.3 years ± 15.3 (SD) (range, 4–69 years). Venous stenosis with a pressure gradient ≥5 mmHg (outflow block) was observed in the inferior vena cava in seven patients, hepatic vein in seven patients, and both in one patient. Technical success, change in a pressure gradient and clinical manifestations, and complications were evaluated. Overall survival of 15 patients undergoing outflow block stenting was compared with that of 116 patients without outflow block after LDLT.ResultsStents were placed across the outflow block veins without complications, lowering the pressure gradient ≤ 3 mmHg in all patients (100 %, 15/15). Clinical manifestations improved in 11 patients (73.3 %, 11/15), and all were discharged from the hospital. However, they did not improve in the other 4 patients (26.7 %, 4/15) who died in the hospital 1.0–3.7 months after stenting (mean, 2.0 ± 1.2 months). No significant difference in 5-year survival rates was found between patients with and without outflow block after LDLT (61.1 vs. 72.2 %, p = .405).ConclusionStenting is a feasible, safe, and useful therapeutic option to resolve outflow block following LDLT, providing equal survival to that of patients without outflow block.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aorta Balloon Occlusion in Trauma: Three Cases Demonstrating Multidisciplinary Approach Already on Patient’s Arrival to the Emergency Room

PurposeTo describe the usage of aortic balloon occlusion (ABO), based on a multidisciplinary approach in severe trauma patients, emphasizing the role of the interventional radiologist in primary trauma care.MethodsWe briefly discuss the relevant literature, the technical aspects of ABO in trauma, and a multidisciplinary approach to the bleeding trauma patient. We describe three severely injured trauma patients for whom ABO was part of initial trauma management.ResultsThree severely injured multi-trauma patients were treated by ABO as a bridge to surgery and embolization. The procedures were performed by an interventional radiologist in the early stages of trauma management.ConclusionsThe interventional radiologist and the multidisciplinary team approach can be activated already on severe trauma patient arrival. ABO usage and other endovascular methods are becoming more widely spread, and can be used early in trauma management, without delay, thus justifying the early activation of this multidisciplinary approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Usefulness of Cone-Beam Computed Tomography and Automatic Vessel Detection Software in Emergency Transarterial Embolization

BackgroundThis study was designed to evaluate the utility of dual phase cone beam computed tomography (DP-CBCT) and automatic vessel detection (AVD) software to guide transarterial embolization (TAE) of angiographically challenging arterial bleedings in emergency settings.MethodsTwenty patients with an arterial bleeding at computed tomography angiography and an inconclusive identification of the bleeding vessel at the initial 2D angiographic series were included. Accuracy of DP-CBCT and AVD software were defined as the ability to detect the bleeding site and the culprit arterial bleeder, respectively. Technical success was defined as the correct positioning of the microcatheter using AVD software. Clinical success was defined as the successful embolization. Total volume of iodinated contrast medium and overall procedure time were registered.ResultsThe bleeding site was not detected by initial angiogram in 20 % of cases, while impossibility to identify the bleeding vessel was the reason for inclusion in the remaining cases. The bleeding site was detected by DP-CBCT in 19 of 20 (95 %) patients; in one case CBCT-CT fusion was required. AVD software identified the culprit arterial branch in 18 of 20 (90 %) cases. In two cases, vessel tracking required manual marking of the candidate arterial bleeder. Technical success was 95 %. Successful embolization was achieved in all patients. Mean contrast volume injected for each patient was 77.5 ml, and mean overall procedural time was 50 min.ConclusionsC-arm CBCT and AVD software during TAE of angiographically challenging arterial bleedings is feasible and may facilitate successful embolization. Staff training in CBCT imaging and software manipulation is necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unenhanced Cone Beam Computed Tomography and Fusion Imaging in Direct Percutaneous Sac Injection for Treatment of Type II Endoleak: Technical Note

AimTo evaluate safety, feasibility, technical success, and clinical success of direct percutaneous sac injection (DPSI) for the treatment of type II endoleaks (T2EL) using anatomical landmarks on cone beam computed tomography (CBCT) and fusion imaging (FI).Materials and MethodsEight patients with T2EL were treated with DPSI using CBCT as imaging guidance. Anatomical landmarks on unenhanced CBCT were used for referencing T2EL location in the first five patients, while FI between unenhanced CBCT and pre-procedural computed tomography angiography (CTA) was used in the remaining three patients. Embolization was performed with thrombin, glue, and ethylene–vinyl alcohol copolymer. Technical and clinical success, iodinated contrast utilization, procedural time, fluoroscopy time, and mean radiation dose were registered.ResultsDPSI was technically successful in all patients: the needle was correctly positioned at the first attempt in six patients, while in two of the first five patients the needle was repositioned once. Neither minor nor major complications were registered. Average procedural time was 45 min and the average administered iodinated contrast was 13 ml. Mean radiation dose of the procedure was 60.43 Gy cm{sup 2} and mean fluoroscopy time was 18 min. Clinical success was achieved in all patients (mean follow-up of 36 months): no sign of T2EL was reported in seven patients until last CT follow-up, while it persisted in one patient with stability of sac diameter.ConclusionsDPSI using unenhanced CBCT and FI is feasible and provides the interventional radiologist with an accurate and safe alternative to endovascular treatment with limited iodinated contrast utilization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Aneurysm Repair and Sealing (EVARS): A Useful Adjunct in Treating Challenging Morphology

An 81-year-old male with previous open abdominal aortic aneurysm repair presented with asymptomatic large pseudoaneurysms at both ends of an open surgical tube graft. Endovascular aneurysm sealing (EVAS) in combination with the iliac limbs of a standard endovascular aneurysm repair (EVAR) successfully excluded both pseudoaneurysms from circulation. We describe the combination of elements of EVAS and EVAR and have termed this endovascular aneurysm repair and sealing (EVARS). EVARS has the advantage of harnessing the benefits of endobag sealing in aortic necks unsuitable for standard EVAR whilst providing the security of accurate stent placement within short common iliac arteries. In conclusion, EVAS may be combined with standard endovascular iliac limbs and is a possible treatment option for pseudoaneurysm following open aneurysm repair.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Osteomyelitis and Discitis Following Translumbar Repair of a Type II Endoleak

Here we present the case of an 80-year-old man who developed a type II endoleak following endovascular abdominal aortic aneurysm repair. Initial attempts at treating the endoleak via a transarterial approach were unsuccessful; therefore the patient underwent percutaneous translumbar endoleak embolization. Approximately 1 month following the translumbar procedure, he developed back pain, with subsequent workup revealing osteomyelitis and discitis as a complication following repair via the translumbar approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostatic Artery Embolization (PAE) for Symptomatic Benign Prostatic Hyperplasia (BPH): Part 1, Pathological Background and Clinical Implications

Pathological features of benign prostatic hyperplasia (BPH) dictate various responses to prostatic artery embolization (PAE). Typically, BPH originates in the transition zone and periurethral region, where should be considered the primary target area in PAE procedures. Given that histological heterogeneity of components in hyperplasia nodules, epithelial or stromal, identifying the more responsive nodules to PAE will have clinical implications. Since some lower urinary tract symptoms (LUTS) in patients with BPH are usually related to bladder outlet obstruction-induced changes in bladder function rather than to outflow obstruction directly, proper selection of candidate patients prior to PAE is of great clinical importance. BPH is a typical chronic progressive condition, suggesting PAE could aim not only to relieve LUTS but also to delay or prevent the clinical progression. Awareness of the pathological background of BPH is essential for interventional radiologists to improve clinical outcomes and develop new treatment strategies in clinical practice of PAE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intra-vesical Prostatic Protrusion (IPP) Can Be Reduced by Prostatic Artery Embolization

BackgroundProstate artery embolization (PAE) is a new approach to improve lower urinary tract symptoms (LUTS) related to benign prostatic hyperplasia. PAE results in global reduction of prostate volume (PV). There are no data available on the efficacy of PAE in reducing intra-vesical prostatic protrusion (IPP), an anatomic feature that is clinically related with bladder outlet obstruction and LUTS.ObjectiveTo assess the results of PAE in patients with significant IPP due to median lobe hyperplasia and to compare the IPSS decrease and IPP change.Material and MethodsProspective analysis of 18 consecutive patients with significant IPP (>5 mm) related to median lobe hyperplasia undergoing PAE using 30–500-μm-calibrated trisacryl microspheres. We measured IPP on sagittal T2-weighted images before and 3 months after PAE. IPSS and clinical results were also evaluated at 3 months.ResultsPAE resulted in significant IPP reduction (1.57 cm ± 0.55 before PAE and 1.30 cm ± 0.46 after PAE, p = 0.0005) (Fig. 1) with no complication. IPSS, quality of life (QoL), total prostate-specific antigen (PSA) level, and PV showed significant reduction after PAE, and maximum urinary flow rate (Q{sub max}) showed significant increase after PAE. No significant change of International Index of Erectile Function (IIEF) for clinical evaluation after PAE. A significant correlation was found between the IPP change and the IPSS change (r = 0.636, p = 0.0045).ConclusionPatients had significant IPP reduction as well as significant symptomatic improvement after PAE, and these improvements were positively correlated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Evaluation and Preparation in Vascular and Interventional Radiology: What Every Interventional Radiologist Should Know (Part 2: Patient Preparation and Medications)

Performing an interventional procedure imposes a commitment on interventional radiologists to conduct the initial patient assessment, determine the best course of therapy, and provide long-term care. Patient care before and after an interventional procedure, identification, and management of early and delayed complications of various procedures are equal in importance to the procedure itself. In this second part, we complete the comprehensive, methodical review of pre-procedural care and patient preparation before vascular and interventional radiology procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk Factors for Immediate and Delayed-Onset Fever After Percutaneous Transhepatic Biliary Drainage

ObjectivesTo prospectively investigate the pre and intra-procedural risk factors for immediate (IF) and delayed-onset (DOF) fever development after percutaneous transhepatic biliary drainage (PTBD).MethodsInstitutional review board approval and informed patient consent were obtained. Between February 2013 and February 2014, 97 afebrile patients (77 at the Sapienza University of Rome, Italy and 20 at the Sun Yat-sen University of Guangzhou, China) with benign (n = 31) and malignant (n = 66) indications for a first PTBD were prospectively enrolled. Thirty pre- and intra-procedural clinical/radiological characteristics, including the amount of contrast media injected prior to PTBD placement, were collected in relation to the development of IF (within 24 h) or DOF (after 24 h). Fever was defined as ≥37.5 °C. Binary logistic regression analysis was used to assess independent associations with IF and DOF.ResultsFourteen (14.4 %) patients developed IF and 17 (17.5 %) developed DOF. At multivariable analysis, IF was associated with pre-procedural absence of intrahepatic bile duct dilatation (OR 63.359; 95 % CI 2.658–1510.055; P = 0.010) and low INR (OR 4.7 × 10{sup −4}; 95 % CI 0.000–0.376; P = 0.025), while DOF was associated with unsatisfactory biliary drainage at the end of PTBD (OR 4.571; 95 % CI 1.161–17.992; P = 0.030).ConclusionsThe amount of contrast injected is not associated with post-PTBD fever development. Unsatisfactory biliary drainage at the end of PTBD is associated with DOF, suggesting that complete biliary tree decompression should be pursued within the first PTBD. Patients with unsatisfactory drainage and those with the absence of pre-procedural intrahepatic bile duct dilatation, which is associated with IF, require tailored post-PTBD management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Amplatzer Vascular Plug Anchoring Technique to Stabilize the Delivery System for Microcoil Embolization

PurposeTo evaluate the feasibility of a novel embolization technique, the Amplatzer vascular plug (AVP) anchoring technique, to stabilize the delivery system for microcoil embolization.Materials and methodsThree patients were enrolled in this study, including two cases of internal iliac artery aneurysms and one case of internal iliac arterial occlusion prior to endovascular aortic repair. An AVP was used in each case for embolization of one target artery, and the AVP was left in place. The AVP detachment wire was then used as an anchor to stabilize the delivery system for microcoil embolization to embolize the second target artery adjacent to the first target artery. The microcatheter for the microcoils was inserted parallel to the AVP detachment wire in the guiding sheath or catheter used for the AVP.ResultsThe AVP anchoring technique was achieved and the microcatheter was easily advanced to the second target artery in all three cases.ConclusionThe AVP anchoring technique was found to be feasible to advance the microcatheter into the neighboring artery of an AVP-embolized artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transjugular Intrahepatic Portosystemic Shunt Flow Reduction with Adjustable Polytetrafluoroethylene-Covered Balloon-Expandable Stents Using the “Sheath Control” Technique

PurposeA complication of transjugular intrahepatic portosystemic shunts (TIPS) placement is refractory portosystemic encephalopathy (PSE) often requiring TIPS reduction. We report the results of a “sheath control technique” utilizing constraining sheaths during deployment of polytetrafluoroethylene (PTFE)-covered balloon-expandable stents, minimizing stent migration, and providing additional procedural control.MethodsTIPS reduction was performed in 10 consecutive patients for PSE using Atrium iCast covered stents (Atrium Maquet Getinge Group, Germany). Within the indwelling TIPS stent, a 9 mm × 59 mm iCast stent was deployed with 2 cm exposed from the sheath’s distal end and the majority of the stent within the sheath to create the distal hourglass shape. During balloon retraction, the stent was buttressed by the sheath. The proximal portion of the stent was angioplastied to complete the hourglass configuration, and the central portion of the stent was dilated to 5 mm. Demographics, pre- and post-procedure laboratory values, and outcomes were recorded.ResultsTen patients underwent TIPS reduction with 100 % technical success. There was no stent migration during stent deployment. All patients experienced initial improvement of encephalopathy. One patient ultimately required complete TIPS occlusion for refractory PSE, and another developed TIPS occlusion 36 days post-procedure. There was no significant trend toward change in patients’ MELD scores immediately post-procedure or at 30 days (p = 0.46, p = 0.47, respectively).ConclusionTIPS reduction using Atrium iCast PTFE balloon-expandable stents using the “sheath control technique” is safe and effective, and minimizes the risk of stent migration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Covered Stent and Coils Embolization of a Pulmonary Artery Pseudoaneurysm After Gunshot Wound

We report the first case of endovascular covered stent implantation for the treatment of a large pulmonary artery pseudoaneurysm (PAPA) following a right thoracic gunshot wound. After resuscitation and hemodynamic stabilization, a CT angiography was performed to analyze the neck size of the PAPA and its position relative to the branches of the parent artery. Covered stent implantation with additional coil embolization was successfully performed. At the 4-year follow-up, the stents remained patent and there was neither pseudoaneurysm recurrence nor treatment-related complication.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Impact of Tunneled Catheters for Ascites and Peritoneal Carcinomatosis on Patient Rehospitalizations

PurposeThe aim of the study is to assess patient outcomes, complications, impact on rehospitalizations, and healthcare costs in patients with malignant ascites treated with tunneled catheters.Materials and MethodsA total of 84 patients with malignant ascites (mean age, 60 years) were treated with tunneled catheters. Patients with peritoneal carcinomatosis and malignant ascites treated with tunneled drain catheter placement over a 3-year period were studied. Overall survival from the time of ascites and catheter placement were stratified by primary cancer and analyzed using the Kaplan–Meier method. Complications were graded by the Common Terminology Criteria for Adverse Events v3.0 (CTCAE). The differences between pre- and post-catheter admissions, hospitalizations, and Emergency Department (ED) visits, as well as related inpatient expenses were compared using paired t tests.ResultsThere were no significant differences in gender, age, or race between different primary cancer subgroups. One patient (1 %) developed bleeding (CTCAE-2). Four patients (5 %) developed local cellulitis (CTCAE-2). Three patients (4 %) had prolonged hospital stay (between 7 and 10 days) to manage ascites-related complications such as abdominal distention, discomfort, or pain. Comparison between pre- and post-catheter hospitalizations showed significantly lower admissions (−1.4/month, p < 0.001), hospital stays (−4.2/month, p = 0.003), and ED visits (−0.9/month, p = 0.002). The pre- and post-catheter treatment health care cost was estimated using MS-DRG IPPS payment system and it demonstrated significant cost savings from decreased inpatient admissions in post-treatment period (−$9535/month, p < 0.001).ConclusionsTunneled catheter treatment of malignant ascites is safe, feasible, well tolerated, and cost effective. Tunneled catheter treatment may play an important role in improving patients’ quality of life and outcomes while controlling health care expenditures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Aneurysm Neck Angle Change After Endovascular Aneurysm Repair Clinical Investigations

PurposeTo evaluate the aneurysm neck angle changes and post-endovascular aneurysm repair (EVAR) complications.MethodsWe retrospectively analyzed 72 cases of elective EVAR for abdominal aortic aneurysm among 109 consecutive cases from December 2005 to April 2014. Patients were divided into angulated and non-angulated groups. The angulated group was defined as neck angulation ≥60°. Neck angle was evaluated pre- and post-EVAR during short- (within 1 month), mid- (3–6 months), and long-term (>1 year) follow-up. Aneurysm sac diameter change, aneurysm neck morphology other than angulation, endoleaks, and other post-procedural complications were also documented.ResultsA total of 34 patients were enrolled in the angulated group. There were no statistical differences in age, sex, follow-up duration, and aneurysm neck profile between the two groups (p > 0.05). Both groups showed statistically significant and consistent decreases in angulation during the follow-up period (p < 0.01). The angulated group revealed 22.45 % more straightening than the non-angulated group. Recoil of the Endurant device occurred in the angulated group. No statistically significant intergroup differences were observed in any endoleaks, complications, or re-intervention rates (p > 0.05). Pre-EVAR angle was the only predictor for post-procedural angle change (p < 0.001).ConclusionEVAR is applicable for patients with highly angulated aneurysm neck and provides consistent neck straightening over long-term follow-up. Recoil was evident in the angulated group using the Endurant device.

62 RADIOLOGY AND NUCLEAR MEDICINE↗