Search NASA⌕ Search

SEARCH · Search NASA

Results for “X radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Transition radiation as a source of cosmic X-rays.

It is shown that transition radiation generated during the passage of relativistic charged particles through interstellar grains can be an important source of cosmic X-rays. In order to account for recent X-ray observations below 300 eV by transition radiation, an energy density in interstellar space of about 10 eV per cu cm in 10 MeV electrons is required. This seems to rule out transition radiation as an important source of diffuse cosmic X-rays in any energy region.

Ramaty, R.↗

Magnetic Flux Plays an Important Role during a Black Hole X-Ray Binary Outburst in Radiative Two-temperature General Relativistic Magnetohydrodynamic Simulations

Abstract Black hole (Bh) X-ray binaries cycle through different spectral states of accretion over the course of months to years. Although persistent changes in the Bh mass accretion rate are generally recognized as the most important component of state transitions, it is becoming increasingly evident that magnetic fields play a similarly important role. In this article, we present the first radiative two-temperature general relativistic magnetohydrodynamics simulations in which an accretion disk transitions from a quiescent state at an accretion rate of M ̇ ∼ 10 − 10 M ̇ Edd to a hard-intermediate state at an accretion rate of M ̇ ∼ 10 − 2 M ̇ Edd . This huge parameter space in mass accretion rate is bridged by artificially rescaling the gas density scale of the simulations. We present two jetted BH models with varying degrees of magnetic flux saturation. We demonstrate that in “standard and normal evolution” models, which are unsaturated with magnetic flux, the hot torus collapses into a thin and cold accretion disk when M ̇ ≳ 5 × 10 − 3 M ̇ Edd . On the other hand, in “magnetically arrested disk” models, which are fully saturated with vertical magnetic flux, the plasma remains mostly hot with substructures that condense into cold clumps of gas when M ̇ ≳ 1 × 10 − 2 M ̇ Edd . This suggests that the spectral signatures observed during state transitions are closely tied to the level of magnetic flux saturation.

Astronomy & Astrophysics↗

Using cyclotron radiation emission for ultra-high resolution x-ray spectroscopy

Abstract Cyclotron radiation emission spectroscopy (CRES) is an approach to measuring the energy of an electron trapped in an externally applied magnetic field. The bare electron can come from different interactions, including photoelectric absorption, Compton scatters, beta decay, and pair production. CRES relies on measuring the frequency of the electron’s cyclotron motion, and because the measurement times extend over 10 6 –10 7 cycles, the energy resolution is on the order of a single electronvolt. To date, CRES has only been performed on internal beta-emitting radioisotopes, but the technology can be applied to x-ray spectrometery through appropriate selection of a target gas and sufficient intensity of the distinct x-ray source. The applications of this technology range from high-precision measurements of atomic energy levels to calibrations of basic science experiments, to trace element identification. In this work we explore the use of CRES for x-ray spectroscopy within the rubric of measuring the energy levels of argon. Though the energy levels of argon are well established, we adopt this motivation as an example question around which a detector may be designed. The issues we explore include target material, density, electron trapping depth, noise levels, and overall efficiency. We also discuss spectral deconvolution and how the multiple peaks obtained from a single target/source pair can be used to enhance the robustness of the measurement.

07 ISOTOPE AND RADIATION SOURCES↗

Electromagnetic Radiation Effects on MgO-Based Magnetic Tunnel Junctions: A Review

Magnetic tunnel junctions (MTJs) have been widely utilized in sensitive sensors, magnetic memory, and logic gates due to their tunneling magnetoresistance. Moreover, these MTJ devices have promising potential for renewable energy generation and storage. Compared with Si-based devices, MTJs are more tolerant to electromagnetic radiation. In this review, we summarize the functionalities of MgO-based MTJ devices under different electromagnetic irradiation environments, with a focus on gamma-ray radiation. We explore the effects of these radiation exposures on the MgO tunnel barriers, magnetic layers, and interfaces to understand the origin of their tolerance. This review enhances our knowledge of the radiation tolerance of MgO-based MTJs, improves the design of these MgO-based MTJ devices with better tolerances, and provides information to minimize the risks of irradiation under various irradiation environments. This review starts with an introduction to MTJs and irradiation backgrounds, followed by the fundamental properties of MTJ materials, such as the MgO barrier and magnetic layers. Then, we review and discuss the MTJ materials and devices’ radiation tolerances under different irradiation environments, including high-energy cosmic radiation, gamma-ray radiation, and lower-energy electromagnetic radiation (X-ray, UV–vis, infrared, microwave, and radiofrequency electromagnetic radiation). In conclusion, we summarize the radiation effects based on the published literature, which might benefit material design and protection.

42 ENGINEERING↗

X-ray spectra and time variability of active galactic nuclei

X ray measurements taken with the HEAO-1 and -2 satellites are examined for clues to the source of emissions from active galactic nuclei (AGN). The data covered the energy range 2-100 keV and 0.5-4.5 keV and encompassed quasars, BL Lac objects, Seyfert I galaxies and broadline radio galaxies. The broadline spectra were best fit with a power law with a slope of about 0.68. The continua displayed roughly equivalent energy at all wavelengths except for radio bands. Spectral variability was detected in the BL Lac objects, which may emit optical, UV and soft X ray radiation from optically thin synchrotron emission with a hard X ray tail from inverse Compton scattering. No strong variability was evidenced with other AGN, suggesting that the emitting regions are below the Eddington luminosity and thus exhibit stable flow characteristics.

Mushotzky, R. F.↗

Effects of a finite plasma temperature on electron-cyclotron maser emission

Auroral kilometric radiation, Jupiter's decametric radio emission, and microwave spike bursts have all been attributed to the semirelativistic maser instability. The effect of a finite plasma temperature on the emission from this instability is investigated. Temperature effects reduce the frequency of the x mode and thereby enable fundamental x-mode radiation to occur at higher omega sub p/Omega sub e (where omega sub p is the plasma frequency and Omega sub e is the electron-cyclotron frequency). When the plasma frequency is sufficiently high to suppress x-mode growth, z-mode growth then dominates. The z-mode radiation is, however, subject to electron-cyclotron damping, and this damping can cause heating of the plasma in the vicinity of the source region. In this case, x-mode radiation can be generated even though initial conditions might favor z-mode growth.

Winglee, R. M.↗

Reduced volume of diabetic pancreatic islets in rodents detected by synchrotron X-ray phase-contrast microtomography and deep learning network

The pancreatic islet is a highly structured micro-organ that produces insulin in response to rising blood glucose. Here we develop a label-free and automatic imaging approach to visualize the islets in situ in diabetic rodents by the synchrotron radiation X-ray phase-contrast microtomography (SRμCT) at the ID17 station of the European Synchrotron Radiation Facility. The large-size images (3.2 mm × 15.97 mm) were acquired in the pancreas in STZ-treated mice and diabetic GK rats. Each pancreas was dissected by 3000 reconstructed images. The image datasets were further analysed by a self-developed deep learning method, AA-Net. All islets in the pancreas were segmented and visualized by the three-dimension (3D) reconstruction. After quantifying the volumes of the islets, we found that the number of larger islets (=>1500 μm 3 ) was reduced by 2-fold (wt 1004 ± 94 vs GK 419 ± 122, P < 0.001) in chronically developed diabetic GK rat, while in STZ-treated diabetic mouse the large islets were decreased by half (189 ± 33 vs 90 ± 29, P < 0.001) compared to the untreated mice. Our study provides a label-free tool for detecting and quantifying pancreatic islets in situ. It implies the possibility of monitoring the state of pancreatic islets in vivo diabetes without labelling.

59 BASIC BIOLOGICAL SCIENCES↗

X-ray induced stellar mass loss near active galactic nuclei

The effects of UV and X-ray radiation on stars in active galactic nuclei (AGN) are critically evaluated. Mass loss rates in X-ray-induced winds are evaluated for realistic red giant models, and the effects of the ablation of stellar envelopes by radiation pressure are considered. The importance of X-ray-induced mass loss in the standard quasar model is evaluated and whether it can provide a source of accretion fuel or emission-line clouds is discussed. It is concluded that thermal winds driven by X-ray heating are a minor total supply of mass to AGN, but that thermal plus line-driven winds and stellar ablation may increase the mass loss and improve the chances for supplying a fraction of the necessary mass supply to the central object. It is speculated that when steady winds are inefficient, complex time-dependent processes due to X-ray energy injection deep into a stellar atmosphere could still release significant mass from stars.

Voit, G. Mark↗

Investigation of Teflon FEP Embrittlement on Spacecraft in Low Earth Orbit

Teflon(registered trademark) FEP (fluorinated ethylene-propylene) is commonly used on exterior spacecraft surfaces in the low Earth orbit (LEO) environment for thermal control. Silverized or aluminized FEP is used for the outer layer of thermal control blankets because of its low solar absorptance and high thermal emittance. FEP is also preferred over other spacecraft polymers because of its relatively high resistance to atomic oxygen erosion. Because of its low atomic oxygen erosion yield, FEP has not been protected in the space environment. Recent, long term space exposures such as on the Long Duration Exposure Facility (LDEF, 5.8 years in space), and the Hubble Space Telescope (HST, after 3.6 years in space) have provided evidence of LEO environmental degradation of FEP. These exposures provide unique opportunities for studying environmental degradation because of the long durations and the different conditions (such as differences in altitude) of the exposures. Samples of FEP from LDEF and from HST (retrieved during its first servicing mission) have been evaluated for solar induced embrittlement and for synergistic effects of solar degradation and atomic oxygen. Micro-indenter results indicate that the surface hardness increased as the ratio of atomic oxygen fluence to solar fluence decreased for the LDEF samples. FEP multilayer insulation (MLI) retrieved from HST provided evidence of severe embrittlement on solar facing surfaces. Micro-indenter measurements indicated higher surface hardness values for these samples than LDEF samples, but the solar exposures were higher. Cracks induced during bend testing were significantly deeper for the HST samples with the highest solar exposure than for LDEF samples with similar atomic oxygen fluence to solar fluence ratios. If solar fluences are compared, the LDEF samples appear as damaged as HST samples, except that HST had deeper induced cracks. The results illustrate difficulties in comparing LEO exposed materials from different missions. Because the HST FEP appears more damaged than LDEF FEP based on depth of embrittlement, other causes for FEP embrittlement in addition to atomic oxygen and ultraviolet (UV) radiation, such as thermal effects and the possible role of soft x-ray radiation, need to be considered. FEP that was exposed to soft x-rays in a ground test facility, showed embrittlement similar to that witnessed in LEO, which indicates that the observed differences between LDEF and HST FEP might be attributed to the different soft x-ray fluences during these two missions.

deGroh, Kim K.↗

Time-resolved investigation of subnanosecond radiation from Al wire hybrid X pinches

K-shell x-ray spectra from Al wire hybrid X pinches have been studied using an x-ray streak camera with better than 0.1-ns time resolution together with a Focusing Spectrograph with Spatial Resolution (FSSR) spectrograph. High-intensity radiation with a continuumlike spectrum was observed in the subnanosecond initial phase of the x-ray pulse generated by the hybrid X pinch (HXP). Here, the absence of spectral lines in this phase and the extremely small x-ray source size indicates the importance of radiative processes in the final phase implosion dynamics. Plasma parameters in the following phases of the HXP were determined from analysis of the line intensities. Point-projection radiography together with a slit-step wedge camera and an FSSR spectrograph without time resolution were used to show the number of radiation sources, and to give information on the time-integrated photon energy spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation burnthrough measurements to infer opacity at conditions close to the solar radiative zone–convective zone boundary

Recent measurements at the Sandia National Laboratory of the x-ray transmission of iron plasma have inferred opacities much higher than predicted by theory, which casts doubt on modeling of iron x-ray radiative opacity at conditions close to the solar convective zone-radiative zone boundary. An increased radiative opacity of the solar mixture, in particular iron, is a possible explanation for the disagreement in the position of the solar convection zone-radiative zone boundary as measured by helioseismology and predicted by modeling using the most recent photosphere analysis of the elemental composition. In this report we present data from radiation burnthrough experiments, which do not support a large increase in the opacity of iron at conditions close to the base of the solar convection zone and provide a constraint on the possible values of both the mean opacity and the opacity in the x-ray range of the Sandia experiments. The data agree with opacity values from current state-of-the-art opacity modeling using the CASSANDRA opacity code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hydroxyl radical mediated damage of proteins in low oxygen solution investigated using X-ray footprinting mass spectrometry

In the method of X-ray footprinting mass spectrometry (XFMS), proteins at micromolar concentration in solution are irradiated with a broadband X-ray source, and the resulting hydroxyl radical modifications are characterized using liquid chromatography mass spectrometry to determine sites of solvent accessibility. These data are used to infer structural changes in proteins upon interaction with other proteins, folding, or ligand binding. XFMS is typically performed under aerobic conditions; dissolved molecular oxygen in solution is necessary in many, if not all, the hydroxyl radical modifications that are generally reported. In this study we investigated the result of X-ray induced modifications to three different proteins under aerobic versus low oxygen conditions, and correlated the extent of damage with dose calculations. We observed a concentration-dependent protecting effect at higher protein concentration for a given X-ray dose. For the typical doses used in XFMS experiments there was minimal X-ray induced aggregation and fragmentation, but for higher doses we observed formation of covalent higher molecular weight oligomers, as well as fragmentation, which was affected by the amount of dissolved oxygen in solution. The higher molecular weight products in the form of dimers, trimers, and tetramers were present in all sample preparations, and, upon X-ray irradiation, these oligomers became non-reducible as seen in SDS-PAGE. The results provide an important contribution to the large body of X-ray radiation damage literature in structural biology research, and will specifically help inform the future planning of XFMS, and well as X-ray crystallography and small-angle X-ray scattering experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-ray and gamma-ray observations of a white-light flare

Hard radiations (X-ray and gamma-ray) from a major solar flare observed by HEAO-1 on July 11, 1978, are discussed. It is noted that the observations showed gamma-ray line and continuum emission extending to the highest energy observed. The lines are identified with the 2.2 MeV line of deuterium formation and the 4.4 MeV line of inelastic scattering on C-12, both of which were previously observed in the flares of August 1972. The flare of July 11 is identified as a white-light flare. It therefore provides the first opportunity for a detailed examination of white-light flare theories that depend on proton heating of the photosphere. The line strength over a four-minute integration at 2.2 MeV is found to be 1.00 + or - 0.29 ph/sq cm-sec; the gamma-ray emission (excluding the 2.2 MeV line which was appreciably delayed) lagged by less than 20 sec approximately after the hard X-ray and microwave fluxes. It is concluded that the 'second-stage' acceleration of high-energy solar particles must commence promptly after the impulsive phase.

Hudson, H. S.↗

A simulation study of the loss cone driven cyclotron maser applied to auroral kilometric radiation

The linear growth and nonlinear saturation of electromagnetic radiation amplified by a hot (5-20 keV) population of electrons possessing a loss cone velocity distribution in the presence of a cold (20-500 eV) electron population are studied. A relativistic electromagnetic simulation code is used to study the emission process. Three cases are presented in detail to illustrate the generation process of auroral kilometric radiation. The first case, which has an electron plasma frequency omega(pe) = 0.2 omega(ce) (electron cyclotron frequency) and possesses a double loss cone distribution, exhibits a strong narrow peak of the fast extraordinary mode (X mode) radiation just above the X mode cutoff frequency. The second case with omega(pe) = 0.2 omega(ce) and a single loss cone distribution shows a preferred direction of propagation for the amplified radiation. The third case with omega(pe) = 0.5 omega(ce) shows a peak in the ordinary mode (O mode) radiation. In all cases, the radiation saturates by turbulent scattering of resonant particles into the loss cone.

Wagner, J. S.↗

A mechanism for bursty radio emission in planetary magnetospheres

Bursty radio emissions are often observed from the polar magnetospheres of the earth, Jupiter, Saturn, and Uranus in addition to the smooth radio emissions commonly detected. It is shown that in plasma regimes in which the electron plasma frequency is less than the electron cyclotron frequency, anisotropic electron beams or gyrating electron beams can excite directly broadband electromagnetic radiation. The largest growth is for right-hand X-mode radiation with frequencies above the electron cyclotron frequency. This instability can produce bursty, broadband emission, consistent with some of the properties of the radiation observed from the magnetized planets.

Wong, H. K.↗

Comparative Effects of Radiation Sterilization Modality on Medical PVC Tubing

As the production volume of single-use, polymer-based medical devices increases each year, so does the need for throughput capacity to sterilize the devices. Around 80% of radiation-sterilized devices are processed using gamma-ray radiation from industrial cobalt-60 sources. Supply chain, security, and disposal concerns are prompting manufacturers and contract sterilizers to explore alternatives to irradiation using cobalt-60 gamma-rays, such as electron beam (E-beam) and X-ray radiation. Advantages of these ‘machine’ sources over radioisotope-based sources are that they do not decay, a characteristic that requires cobalt-60 to be replaced over time, they can be turned off when not in use, and they do not represent the same level of concern regarding misuse. One of the barriers to direct transition from gamma-ray sterilization to E-beam or X-ray sterilization is concern over the relatively unknown effects of sterilization dose of these alternative modalities on the performance of medical device polymers. Commercially available medical devices sterilized with gamma-ray irradiation exhibit acceptable device function, acceptable mechanical performance, and acceptable discoloration. To be viable, alternate sterilization methods must not only achieve acceptable sterilization, but the process must also result in a product with functional, mechanical, and visual effects acceptable to customers and the regulator. Flexible polyvinyl chloride (PVC) is a plastic material that is commonly found in single-use medical devices and is known for its sensitivity to radiation processing. For instance, transparent PVC is known to yellow upon irradiation. To encouraging sterilization alternatives to cobalt-60 gamma-ray, we directly compared the effects of gamma-ray, E-beam, and X-ray radiation exposure at similar sterilization-relevant doses on key properties of medical grade PVC tubing.

cobalt-60↗

Visible emission spectra of thermographic phosphors under x-ray excitation

Thermographic phosphors have been employed for temperature sensing in challenging environments, such as on surfaces or within solid samples exposed to dynamic heating, because of the high temporal and spatial resolution that can be achieved using this approach. Typically, UV light sources are employed to induce temperature-sensitive spectral responses from the phosphors. However, it would be beneficial to explore x-rays as an alternate excitation source to facilitate simultaneous x-ray imaging of material deformation and temperature of heated samples and to reduce UV absorption within solid samples being investigated. Here, the phosphors BaMgAl 10 O 17 :Eu (BAM), Y 2 SiO 5 :Ce, YAG:Dy, La 2 O 2 S:Eu, ZnGa 2 O 4 :Mn, Mg 3 F 2 GeO 4 :Mn, Gd 2 O 2 S:Tb, and ZnO were excited using incident synchrotron x-ray radiation. These materials were chosen to include conventional thermographic phosphors as well as x-ray scintillators (with crossover between these two categories). X-ray-induced thermographic behavior was explored through the measurement of visible spectral response with varying temperature. The incident x-rays were observed to excite the same electronic energy level transitions in these phosphors as UV excitation. Similar shifts in the spectral response of BAM, Y 2 SiO 5 :Ce, YAG:Dy, La 2 O 2 S:Eu, ZnGa 2 O 4 :Mn, Mg 3 F 2 GeO 4 :Mn, and Gd 2 O 2 S:Tb were observed when compared to their response to UV excitation found in literature. Some phosphors were observed to thermally quench in the temperature ranges tested here, while the response from others did not rise above background noise levels. This may be attributed to the increased probability of non-radiative energy release from these phosphors due to the high energy of the incident x-rays. These results indicate that x-rays can serve as a viable excitation source for phosphor thermometry.

42 ENGINEERING↗