Search NASA⌕ Search

SEARCH · Search NASA

Results for “X radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A portable X-pinch design for x-ray diagnostics of warm dense matter

We describe the design and x-ray emission properties (temporal, spatial, and spectral) of Dry Pinch I, a portable X-pinch driver developed at Imperial College London. Dry Pinch I is a direct capacitor discharge device, 300 × 300 × 700 mm3 in size and ∼50 kg in mass, that can be used as an external driver for x-ray diagnostics in high-energy-density physics experiments. Among key findings, the device is shown to reliably produce 1.1 ± 0.3 ns long x-ray bursts that couple ∼50 mJ of energy into photon energies from 1 to 10 keV. The average shot-to-shot jitter of these bursts is found to be 10 ± 4.6 ns using a combination of x-ray and current diagnostics. The spatial extent of the x-ray hot spot from which the radiation emanates agrees with previously published results for X-pinches—suggesting a spot size of 10 ± 6 µm in the soft energy region (1–10 keV) and 190 ± 100 µm in the hard energy region (>10 keV). These characteristics mean that Dry Pinch I is ideally suited for use as a probe in experiments driven in the laboratory or at external facilities when more conventional sources of probing radiation are not available. At the same time, this is also the first detailed investigation of an X-pinch operating reliably at current rise rates of less than 1 kA/ns.

47 OTHER INSTRUMENTATION↗

Toward fully coherent soft x-ray free-electron laser via echo-enabled harmonic generation in fourth generation synchrotron light sources

Having previously reported on bunching via echo-enabled harmonic generation (EEHG) as an effective way to improve the longitudinal coherence in the NSLS-II storage ring [X. Yang et al., Sci. Rep. 12, 9437 (2022)], we demonstrate that this EEHG scheme can be easily adopted to any fourth generation diffraction-limited synchrotron light source with significant benefits. The advantage of the scheme is that it requires no change of the lattice and is fully compatible with other beamlines. Since the EEHG performance is mainly determined by the momentum compaction, beam emittances, and beta functions of a SR lattice, we have identified these crucial parameters and successfully built a generalized model, which can predict the performance of nearly any SLS. Regarding the fourth generation SLSs, momentum compactions are often significantly smaller; thus, to cover the x rays with a photon energy of up to 1 keV, we utilize a specific design, including a 250 nm seed-laser wavelength. Our model predicts that for most of the current and future fourth generation SLSs, the EEHG scheme can produce significant prebunching up to harmonic 200 and, thus, generate a few MW scale peak power at 1.25 nm wavelength.

47 OTHER INSTRUMENTATION↗

Metal Halide Scintillators with Fast and Self‐Absorption‐Free Defect‐Bound Excitonic Radioluminescence for Dynamic X‐Ray Imaging

Abstract Scintillators for radiation detection are of great significance in medical imaging, security, and nondestructive inspection. The current challenge for scintillators is to simultaneously achieve high scintillation light yield, fast radioluminescence, simple film fabrication, large X‐ray attenuation efficiency as well as stable and nontoxic compositions; no previous scintillators fulfill all the above requirements. Here, metal halide Rb 2 AgBr 3 , possessing defect‐bound excitonic radioluminescence, is shown as efficient and fast scintillators. This nontoxic and stable scintillator emits from excitons bound to neutral bromine vacancies, enjoying an efficient and spin‐allowed fast emission with minimized self‐absorption. Rb 2 AgBr 3 thus has a high light yield (25 600 photons MeV −1 ), fast scintillation decay time (5.31 ns), and a record value of light yield versus decay time (4821 photons MeV −1 ns −1 ). The close‐space sublimation method is developed for fast and scalable fabrication of oriented Rb 2 AgBr 3 films. The scintillator film is further integrated with commercial flat‐panel imagers, and the spatial resolution reaches 10.2 line pairs per millimeter at the modulation transfer function of 0.2, doubling the resolution of conventional CsI:Tl flat‐panel detectors. The dynamic X‐ray imaging and its use to real‐time monitoring of bone movement without ghosting effect is also demonstrated.

Zhang, Muyi↗

Photon-In/Photon-Out X-ray Free-Electron Laser Studies of Radiolysis

Understanding the origin of reactive species following ionization in aqueous systems is an important aspect of radiation–matter interactions as the initial reactive species lead to production of radicals and subsequent long-term radiation damage. Tunable ultrafast X-ray free-electron pulses provide a new window to probe events occurring on the sub-picosecond timescale, supplementing other methodologies, such as pulse radiolysis, scavenger studies, and stop flow that capture longer timescale chemical phenomena. We review initial work capturing the fastest chemical processes in liquid water radiolysis using optical pump/X-ray probe spectroscopy in the water window and discuss how ultrafast X-ray pump/X-ray probe spectroscopies can examine ionization-induced processes more generally and with better time resolution. Ultimately, these methods will be applied to understanding radiation effects in complex aqueous solutions present in high-level nuclear waste.

47 OTHER INSTRUMENTATION↗

Density evolution after shock release from laser-driven polystyrene (CH) targets in inertial confinement fusion

The evolution of the plasma density in the rarefaction wave formed after a laser-driven shock is released from a CH foil was measured using optical interferometry. Here, it was found that the plasma density profile is very sensitive to the conditions at the back surface of the foil before the shock release. Dedicated experiments demonstrated that radiation preheat by coronal x-rays caused early expansion of the back surface and faster expansion of the rarefaction wave. Radiation-hydrodynamics simulations with accurate modeling of radiation preheat from the plasma corona are in good agreement with the experimental results. The early expansion of material interfaces due to coronal x-ray preheat must be evaluated in designing and interpreting laser-driven inertial confinement fusion experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Limits on Leptonic TeV Emission from the Cygnus Cocoon with Swift-XRT

$\gamma$-ray observations of the Cygnus Cocoon, an extended source surrounding the Cygnus X star-forming region, suggest the presence of a cosmic ray accelerator reaching energies up to a few PeV. The very-high-energy (VHE; 0.1-100~TeV) $\gamma$-ray emission may be explained by the interaction of cosmic-ray hadrons with matter inside the Cocoon, but an origin of inverse Compton radiation by relativistic electrons cannot be ruled out. Inverse Compton $\gamma$-rays at VHE are accompanied by synchrotron radiation peaked in X-rays. Hence, X-ray observations may probe the electron population and magnetic field of the source. We observed eleven fields in or near the Cygnus Cocoon with the Neil Gehrels Swift Observatory's X-Ray Telescope (Swift-XRT) totaling 110 ksec. We fit the fields to a Galactic and extra-galactic background model and performed a log-likelihood ratio test for an additional diffuse component. We found no significant additional emission and established upper limits in each field. By assuming that the X-ray intensity traces the TeV intensity and follows an dN/dE ∝ E -2.5 spectrum, we obtained a 90% upper limit of F X < 8.7 x 10 -11 erg cm -2 s -1 or 5.2 x10 -11 erg cm -2 s -1 on the X-ray flux of the entire Cygnus Cocoon between 2 and 10 keV depending on the choice of hydrogen column density model. This suggests that no more than one quarter of the $\gamma$-ray flux at 1 TeV is produced by inverse Compton scattering, when assuming an equipartition magnetic field of ~20 μG.

79 ASTRONOMY AND ASTROPHYSICS↗

Ku-band electron linac for battery-powered hand-portable 2-MeV X-ray generator

X-ray generators, producing radiation in MeV range, are a critical tool for radiography, non-destructive testing and security applications. Field operation of such source requires them to be hand-portable, autonomous and allow parameter adjustability. RF linear accelerators can serve as a flexible, reliable, and robust radiation generator alternative to dangerous radioisotopes and bulky betatrons that are currently used for field radiography if their size, weight, cost, and imaging performance are matched to these sources. Here, in this paper, we present the design and test results of a 2 MeV Ku-band electron linac for a hand-portable X-ray generator system for field radiography being developed by RadiaBeam. The dramatic scale of miniaturization and cost-reduction is achieved thanks to the implementation of innovative technologies such as air-cooled Ku-band air-traffic control magnetrons, a split accelerating structure fabrication technique, and solid-state Marx modulators. This paper presents the design of the first prototype of the accelerator, its operation from Li-Ion batteries, as well as high-power and beam measurements.

43 PARTICLE ACCELERATORS↗

Tuning Organic Semiconductor Packing and Morphology through Non-equilibrium Solution Processing (Final Report)

Organic semiconductors (OSCs) are a promising candidate to produce low-cost, large area, and flexible electronics. There has previously been successful development of organic field effect transistors (OFETs), photovoltaics (OPV), and bioelectronics using OSCs. Solution processing of these materials allows for the fabrication of large-area devices in the kinetic crystallization regime. The charge transport capabilities have been shown to depend on the morphology and molecular packing of the OSC within thin films. Our hypothesis is that solution processing conditions may significantly impact OSC morphology and as a result the charge transport. Therefore, this work has focused on obtaining a fundamental understanding of the morphology and molecular packing of OSCs for optimal device performance. Through our work, we have gained a better understanding of how these structural conditions were influenced by the solution processing conditions. Our studies have led to a more systematic understanding of the various parameters that impact OSC morphology. Solution processing leads to non-equilibrium films, thus allowing for the formation of diverse morphologies that are inaccessible by other fabrication methods. Previously, our group has focused on tuning the morphology of small-molecular OSCs [53, 55-57]. However, little work had been devoted to polymer OSCs. There was a lack of detailed studies characterizing the solution-state of polymer OSCs in terms of their conformation, degree of entanglement, polymer aggregation, and chain relaxation dynamics. The solution state properties are also likely to be influenced by the rigidity and molecular weight of the polymer OSCs investigated. Thus, we have focused our attention on gaining a better insight of polymer OSC films and solution processing methods. Through this proposal, our approach is to investigate the correlation between solution-state properties and the morphology of the resulting polymer OSC films. We worked three specific aims: investigate the effects of 1) polymer OSC solution-state properties on final film morphology; 2) molecular additives on the solution-state and final film properties; 3) controlled pre-aggregation in the solution-state in the final film morphology. More rigid and planar polymer backbones should promote interchain charge transport and more efficient interchain hopping between polymer chains. Through tailoring the polymer backbone, polymer sidechains, and molecular weight, we expected the altered solution-state properties to affect the final film morphology. In addition, reducing the entanglements and promoting chain alignment will likely prevent charge carrier trapping through conformation disorders. We thus studied different mechanisms, such as molecular additives, to reduce entanglements in solution. Devices fabricated from these solutions were expected to have improved charge transport abilities. In addition to tailoring the solution-state characteristics of the polymer OSCs, we investigated the effect of solution processing methods on the molecular packing and morphology of polymer OSC films. Two main solution processing techniques, e.g., spin-coating and solution shearing, were employed to fabricate OFETs. Spin coating was employed to prepare OSC films, which produce isotropic films. This technique creates several parameters to tune such as spin coating speed, acceleration, and time. Additionally, our research group developed the solution shearing method, which consists of the solution initially sandwiched between two plates. By sliding the top plate, the solution front is exposed and drying begins. This technique allows for the creation of aligned large crystalline domains. Solution shearing consists of different processing parameters which can affect the final morphology, such as shearing speed, substrate temperature and temperature gradient, distance between both plates, and the tilt angle of the top plate. Due to the complexity of the polymer systems investigated, numerous techniques were employed to characterize the polymer OSC solution state and films. All the materials were characterized using the DOE supported synchrotron X-ray scattering facilities at the Stanford Synchrotron Radiation Lightsource (SSRL). Using grazing incidence X-ray scattering (GIXS) and Near Edge X-ray Absorption Fine Structure (NEXAFS) techniques, the crystalline structure and molecular orientations of the thin films were measured. Optical absorption (UV-Vis) spectroscopy was employed to determine the aggregation state in solution and films of the polymer systems. Polarized UV-Vis also allowed for the determination of the relative degree of polymer chain alignment for solution sheared films. Additionally, various other techniques were used to investigate other properties within the film, such as atomic force microscopy (AFM) and solution rheology. Finally, the device performance is quantified through the fabrication and characterization of OFETs, which will highlight the effects of morphology on charge transport.

36 MATERIALS SCIENCE↗

Improvements to the characterization of Agfa x-ray film for use on opacity spectroscopy diagnostics

The National Ignition Facility uses a soft x-ray opacity spectrometer for x-ray spectral imaging in high-energy-density experiments. The increased demand for a better spectral resolution prompted the investigation into the Agfa D4 film. Characterization is already under way for the film. A Manson x-ray source using six different anodes was used to expose film to the linear optical density (OD) region. This is a continuation of the previous work, and the updated analysis process is communicated here. The identified uncertainties have been reduced with the updated steps that improve the results of the characterization process. In conclusion, when the Stanford Synchrotron Radiation Lightsource Beamline 16-2 was operational, the film was characterized at that source. Its beam offered a higher fluency with a lower exposure time needed to reach saturation. Results for both sources are compared in this paper.

47 OTHER INSTRUMENTATION↗

BASS XXXII: Studying the Nuclear Millimeter-wave Continuum Emission of AGNs with ALMA at Scales ≲100–200 pc

To understand the origin of nuclear (≲100 pc) millimeter-wave (mm-wave) continuum emission in active galactic nuclei (AGNs), we systematically analyzed subarcsecond resolution Band-6 (211–275 GHz) Atacama Large Millimeter/submillimeter Array data of 98 nearby AGNs (z < 0.05) from the 70 month Swift/BAT catalog. The sample, almost unbiased for obscured systems, provides the largest number of AGNs to date with high mm-wave spatial resolution sampling (~1–200 pc), and spans broad ranges of 14–150 keV luminosity {$40\lt \mathrm{log}[{L}_{14-150}/(\mathrm{erg}\,{{\rm{s}}}^{-1})]\lt 45$}, black hole mass $[5\lt \mathrm{log}({M}_{\mathrm{BH}}/{M}_{\odot })\lt 10$], and Eddington ratio ($-4\lt \mathrm{log}{\lambda }_{\mathrm{Edd}}\lt 2$). We find a significant correlation between 1.3 mm (230 GHz) and 14–150 keV luminosities. Its scatter is ≈0.36 dex, and the mm-wave emission may serve as a good proxy of the AGN luminosity, free of dust extinction up to N H ~ 10 26 cm –2 . While the mm-wave emission could be self-absorbed synchrotron radiation around the X-ray corona according to past works, we also discuss different possible origins of the mm-wave emission: AGN-related dust emission, outflow-driven shocks, and a small-scale (<200 pc) jet. The dust emission is unlikely to be dominant, as the mm-wave slope is generally flatter than expected. Also, due to no increase in the mm-wave luminosity with the Eddington ratio, a radiation-driven outflow model is possibly not the common mechanism. Furthermore, we find independence of the mm-wave luminosity on indicators of the inclination angle from the polar axis of the nuclear structure, which is inconsistent with a jet model whose luminosity depends only on the angle.

79 ASTRONOMY AND ASTROPHYSICS↗

Detecting ionizing radiation using halide perovskite semiconductors processed through solution and alternative methods

We report the direct detection of high-energy radiation such as X-rays and.-rays by semiconductors at room temperature is a challenging proposition that requires remarkably pure and nearly perfect crystals. The emergence of metal halide perovskites, defect-tolerant semiconductors, is reviving hope for new materials in this field after an almost 20 year hiatus. Metal halide perovskites, which combine exceptional optoelectronic properties, versatile chemistry and simple synthesis, are challenging traditional approaches for the development of novel semiconductors for detecting hard radiation. We discuss the relevant physical properties, promising materials, fabrication techniques and device architectures for high-performance, low-cost detectors by targeting next-generation semiconductors for radiation detection. We also present a perspective on the impact of such advances in future medical imaging applications.

36 MATERIALS SCIENCE↗

Use of a Mylar filter to eliminate vacuum ultraviolet pulse pileup in low-energy x-ray measurements

We describe a method to reduce vacuum ultraviolet (VUV) pulse pileup (PPU) in x-ray pulse-height Silicon Drift Detector (SDD) signals. An Amptek FAST SDD, with C1 (Si 3 N 4 ) window, measures bremsstrahlung emitted from PFRC-2 plasma to extract the electron temperature (T e ) and density (n e ). The C1 window has low transmissivity for photons with energy below 200 eV though will transmit some VUV and soft x-ray photons, which PFRC-2 plasmas abundantly emit. Multi-VUV-photon PPU contaminates the interpretation of x rays with energy > 100 eV, particularly in a low-energy exponential tail. The predicted low transmissivity of ~1 μm thick Mylar [polyethylene terephthalate (PET)] to photons of energy <100 eV led to the selection of Mylar as the candidate filter to reduce VUV PPU. Experiments were conducted on an x-ray tube with a graphite target and on a quasi-Maxwellian tenuous plasma (n e ~ 10 9 cm –3 ) with effective temperatures reaching 1500 eV. A Mylar filter thickness of 850 nm is consistent with the results. The Mylar-filter-equipped SDD was then used on the PFRC-2 plasma, showing a substantial reduction in the low-energy x-ray signal, supporting our hypothesis of the importance of VUV PPU. Here, we describe the modeling and experiments performed to characterize the effect of the Mylar filter on SDD measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NuSTAR tests of sterile-neutrino dark matter: New Galactic bulge observations and combined impact

In this work, we analyze two dedicated NuSTAR observations with exposure ~190 ks located ~10° from the Galactic plane, one above and the other below, to search for x-ray lines from the radiative decay of sterile-neutrino dark matter. These fields were chosen to minimize astrophysical x-ray backgrounds while remaining near the densest region of the dark matter halo. We find no evidence of anomalous x-ray lines in the energy range 5–20 keV, corresponding to sterile neutrino masses 10–40 keV. Interpreted in the context of sterile neutrinos produced via neutrino mixing, these observations provide the leading constraints in the mass range 10–12 keV, improving upon previous constraints in this range by a factor ~2. We also compare our results to Monte Carlo simulations, showing that the fluctuations in our derived limit are not dominated by systematic effects. An updated model of the instrumental background, which is currently under development, will improve NuSTAR’s sensitivity to anomalous x-ray lines, particularly for energies 3–5 keV.

79 ASTRONOMY AND ASTROPHYSICS↗

New high-throughput endstation to accelerate the experimental optimization pipeline for synchrotron X-ray footprinting

Synchrotron X-ray footprinting (XF) is a growing structural biology technique that leverages radiation-induced chemical modifications via X-ray radiolysis of water to produce hydroxyl radicals that probe changes in macromolecular structure and dynamics in solution states of interest. The X-ray Footprinting of Biological Materials (XFP) beamline at the National Synchrotron Light Source II provides the structural biology community with access to instrumentation and expert support in the XF method, and is also a platform for development of new technological capabilities in this field. Hee, the design and implementation of a new high-throughput endstation device based around use of a 96-well PCR plate form factor and supporting diagnostic instrumentation for synchrotron XF is described. This development enables a pipeline for rapid comprehensive screening of the influence of sample chemistry on hydroxyl radical dose using a convenient fluorescent assay, illustrated here with a study of 26 organic compounds. The new high-throughput endstation device and sample evaluation pipeline now available at the XFP beamline provide the worldwide structural biology community with a robust resource for carrying out well optimized synchrotron XF studies of challenging biological systems with complex sample compositions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A variable X-ray chopper system for phase-sensitive detection in synchrotron X-ray scanning tunneling microscopy

An ultra-high-vacuum compatible X-ray chopper system has been designed, constructed and integrated into the XTIP beamline at the Advanced Photon Source at Argonne National Laboratory. The XTIP beamline can operate at soft X-ray energies from 400 eV to 1900 eV while providing a focused beam down to about 10 µm × 10 µm into the synchrotron X-ray scanning tunneling microscopy (SX-STM) endstation instrument. The X-ray chopper is a critical component for separating topographic information from chemical information in SX-STM through phase-sensitive current detection. Depending on the experimental needs, the modulation frequency can be controlled from 100 Hz to 10 kHz. In addition, the chopper system is fully bakeable and can achieve a base pressure of 10 -10 mbar. Facilities for active water cooling have been designed, but passive cooling through copper braids has been shown to be sufficient at standard chopping frequencies. Using an Fe/Al 2 O 3 /CoAl(111) sample, the separation of the SX-STM current into a chemical component and a stable feedback signal is demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mapping 3D grain and precipitate structure during in situ mechanical testing of open-cell metal foam using micro-computed tomography and high-energy X-ray diffraction microscopy

Open-cell metal foams are ultra-low-density cellular metals with complex hierarchical structures that span bulk, cell, ligament, and sub-ligament scales and give rise to desirable properties such as high strength-to-weight ratio and excellent energy absorption. Although literature suggests that intrinsic material structures at sub-ligament length scales (e.g., grains and precipitates) play an important role in mechanical behavior of open-cell metal foams, there are very few experimental measurements of such structures in three dimensions and for meaningful volumes of foam. This study seeks to map and track the three-dimensional (3D) grain and precipitate structures of an intact volume of open-cell aluminum foam by advancing microstructural characterization techniques that leverage X-ray micro-computed tomography (μCT) and far-field high-energy X-ray diffraction microscopy (FF-HEDM). A 6%-relative-density aluminum foam sample was mechanically tested in compression while μCT and FF-HEDM measurements were collected at interrupted loading states at beamline 1-ID of the Advanced Photon Source. Further, a new scanning strategy and reconstruction algorithm were established to enable characterization of a foam volume with diameter approximately four times wider than the nominal width of the X-ray beam. The result is a set of maps that detail both the 3D grain and precipitate structures throughout the foam volume at successive strain steps. A novel grain tracking procedure was developed to track individual grains within the foam volume by accounting for the large rigid-body motions that individual ligaments can undergo during mechanical loading. The ability to track grains and precipitate structures in three dimensions throughout large bulk deformation of ultra-low-density polycrystalline materials enables new possibilities for validating numerical models and investigating local failure mechanisms. Furthermore, the methods and procedures developed in this study could be applied to other ultra-low-density structures, such as additively manufactured lattices.

36 MATERIALS SCIENCE↗

Dark field X-ray microscopy below liquid-helium temperature: The case of NaMnO 2

Dark field X-ray microscopy (DFXM) is an experimental technique employed to investigate material properties by probing their ‘mesoscale,’ or microscale structures, in a bulk-sensitive manner using hard X-rays at synchrotron radiation sources. However, challenges remain when it comes to applications of this technique to examine low-temperature phenomena in quantum materials, which exhibit complex phase transitions at cryogenic temperatures. One such material is NaMnO 2 , which hosts an antiferromagnetic transition at 45 K that is suspected to coincide with local structural transitions from its majority monoclinic phase to nanoscale triclinic domains. Direct observation of local heterogeneities and this effect at low temperatures in NaMnO 2 is an important step in understanding this material and serves as an ideal candidate study for expanding the DFXM experimental design space. This paper details a foundational high-resolution DFXM study, down to liquid-helium temperature and below, conducted to explore phase transitions in NaMnO 2 . In conclusion, the outlined experiment ushers in the evaluation of other functional materials at low temperatures using this technique.

36 MATERIALS SCIENCE↗

Emergence of complex-regular eutectic patterns in Al–Ge: Observations from correlative nano-imaging

Eutectic solidification exemplifies nonequilibrium pattern formation, making it a well-studied moving boundary problem. Yet the mechanisms behind the formation of complex-regular microstructures – particularly in highly anisotropic systems with a significant volume fraction of a faceted phase – remain poorly understood. Our understanding of such systems is made complicated by the nonlinear interface kinetics and unique growth dynamics characteristic of faceted phases. To address these challenges, we investigate a model Al–Ge eutectic system, where the faceted Ge phase constitutes a substantial volume fraction (~0.35) and where the two solid phases arrange into so-called “fishbone” or “feather” complex-regular patterns. Using synchrotron-based x-ray nano-imaging and nanotomography with high spatial resolution (22 nm per pixel), we capture in real-time the evolution of the solid–liquid interfaces and the resulting three-dimensional microstructures in this faceted/non-faceted eutectic system. By integrating these observations with electron backscattered diffraction, we elucidate the crystallographic biases on the solidification process and the mechanisms driving the formation of such complex-regular microstructures. These findings inform a new growth model for irregular eutectics in (near-)symmetrical phase diagrams, offering insight on advanced microstructural design and processing strategies. More broadly, we demonstrate how interfacial curvature is generated in irregular eutectic alloys and how it depends on the volume fraction of the faceted phase.

36 MATERIALS SCIENCE↗