Search NASA⌕ Search

SEARCH · Search NASA

Results for “X ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Speckle contrast of interfering fluorescence X-rays

With the development of X-ray free-electron lasers (XFELs), producing pulses of femtosecond durations comparable with the coherence times of X-ray fluorescence, it has become possible to observe intensity–intensity correlations due to the interference of emission from independent atoms. This has been used to compare durations of X-ray pulses and to measure the size of a focused X-ray beam, for example. Here it is shown that it is also possible to observe the interference of fluorescence photons through the measurement of the speckle contrast of angle-resolved fluorescence patterns. Speckle contrast is often used as a measure of the degree of coherence of the incident beam or the fluctuations of the illuminated sample as determined from X-ray diffraction patterns formed by elastic scattering, rather than from fluorescence patterns as addressed here. Commonly used approaches to estimate speckle contrast were found to suffer when applied to XFEL-generated fluorescence patterns due to low photon counts and a significant variation of the excitation pulse energy from shot to shot. A new method to reliably estimate speckle contrast under such conditions, using a weighting scheme, is introduced. The method is demonstrated by comparing the speckle contrast of fluorescence observed with pulses of 3 fs to 15 fs duration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Antiferromagnetic real-space configuration probed by dichroism in scattered x-ray beams with orbital angular momentum

X-ray beams with orbital angular momentum (OAM) are a promising tool for x-ray characterization techniques. Beams with OAM have a helicity - an azimuthally varying phase - which leads to a gradient of the light field. New material properties can be probed by utilizing the helicity of an OAM beam. Here, we demonstrate a dichroic effect in resonant diffraction from an artificial antiferromagnet with a topological defect. We found that the scattered OAM beam has circular dichroism at the antiferromagnetic Bragg peak whose sign is coupled to its helicity, which reveals the real-space configuration of the antiferromagnetic ground state. Thermal cycling of the artificial antiferromagnet can change the ground state, as indicated by reversal of the sign of circular dichroism. This result is one of the first demonstrations of a soft x-ray spectroscopy characterization technique utilizing the OAM of x rays. In conclusion, this helicity-dependent circular dichroism exemplifies the potential to utilize OAM beams to probe matter in a way that is inaccessible using currently available x-ray techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In situ synchrotron x-ray studies of epitaxial SrCoO x films during ionic liquid gating

The manipulation of ions in complex oxide materials can be used to mimic brain-like plasticity through changes to the resistivity of a neuromorphic device. Advances in the design of more energy efficient devices require improved understanding of how ions migrate within a material and across its interface. We investigate the exchange of oxygen and hydrogen in a model SrCoO x epitaxial film—a material that transitions between a ferromagnetic metal and antiferromagnetic insulator depending on the oxygen concentration. Changes to the film during ionic liquid gating were measured by in situ synchrotron x-ray techniques as a function of time and gate voltage, examining the reversibility of the oxide over one complete gating cycle. We find that the out-of-plane lattice constant and oxygen vacancy concentration of SrCoO x are largely reversible although changes were observed in the ordered vacancy structure. Our results provide much needed insight into electrolyte-gated phase behavior in the transition metal oxides.

Li, Yan [Argonne National Laboratory (ANL), Argonn↗

Sizes of pure and doped helium droplets from single shot x-ray imaging

Advancements in x-ray free-electron lasers on producing ultrashort, ultrabright, and coherent x-ray pulses enable single-shot imaging of fragile nanostructures, such as superfluid helium droplets. Furthermore, this imaging technique gives unique access to the sizes and shapes of individual droplets. In the past, such droplet characteristics have only been indirectly inferred by ensemble averaging techniques. Here, we report on the size distributions of both pure and doped droplets collected from single-shot x-ray imaging and produced from the free-jet expansion of helium through a 5 μm diameter nozzle at 20 bars and nozzle temperatures ranging from 4.2 to 9 K. This work extends the measurement of large helium nanodroplets containing 10 9 –10 11 atoms, which are shown to follow an exponential size distribution. Additionally, we demonstrate that the size distributions of the doped droplets follow those of the pure droplets at the same stagnation condition but with smaller average sizes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Path-Integrated X-Ray Digital Image Correlation using Synthetic Reference Images

X-rays can provide images when an object is visibly obstructed, allowing for motion measurements via x-ray digital image correlation (DIC). However, x-ray images are path-integrated and contain data for all objects between the source and detector. If multiple objects are present in the x-ray path, conventional DIC algorithms may fail to correlate the x-ray images. A new DIC algorithm called path-integrated (PI)-DIC addresses this issue by reformulating the matching criterion for DIC to account for multiple, independently-moving objects. PI-DIC requires a set of reference x-ray images of each independent object. However, due to experimental constraints, such reference images might not be obtainable from the experiment. Here, this work focuses on the reliability of synthetically-generated reference images, in such cases. A simplified exemplar is used for demonstration purposes, consisting of two aluminum plates with tantalum x-ray DIC patterns undergoing independent rigid translations. Synthetic reference images based on the “as-designed” DIC patterns were generated. However, PI-DIC with the synthetic images suffered some biases due to manufacturing defects of the patterns. A systematic study of seven identified defect types found that an incorrect feature diameter was the most influential defect. Synthetic images were re-generated with the corrected feature diameter, and PI-DIC errors were improved by a factor of 3-4. Final biases ranged from 0.00-0.04 px, and standard uncertainties ranged from 0.06-0.11 px. In conclusion, PI-DIC accurately measured the independent displacement of two plates from a single series of path-integrated x-ray images using synthetically-generated reference images, and the methods and conclusions derived here can be extended to more generalized cases involving stereo PI-DIC for arbitrary specimen geometry and motion. This work thus extends the application space of x-ray imaging for full-field DIC measurements of multiple surfaces or objects in extreme environments where optical DIC is not possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayesian optimization to design a novel x-ray shaping device

In radiation therapy, x-ray dose must be precisely sculpted to the tumor, while simultaneously avoiding surrounding organs at risk. This requires modulation of x-ray intensity in space and/or time. Typically, this is achieved using a multi leaf collimator (MLC) - a complex mechatronic device comprising over one hundred individually powered tungsten ‘leaves’ that move in or out of the radiation field as required. Here, an all-electronic x-ray collimation concept with no moving parts is presented, termed “SPHINX”: Scanning Pencil-beam High-speed Intensity-modulated X-ray source. SPHINX utilizes a spatially distributed bremsstrahlung target and collimator array in conjunction with magnetic scanning of a high energy electron beam to generate a plurality of small x-ray “beamlets.” A simulation framework was developed in Topas Monte Carlo incorporating a phase space electron source, transport through user defined magnetic fields, bremsstrahlung x-ray production, transport through a SPHINX collimator, and dose in water. This framework was completely parametric, meaning a simulation could be built and run for any supplied geometric parameters. This functionality was coupled with Bayesian optimization to find the best parameter set based on an objective function which included terms to maximize dose rate for a user defined beamlet width while constraining inter-channel cross talk and electron contamination. Designs for beamlet widths of 5, 7, and 10 mm 2 were generated. Each optimization was run for 300 iterations and took approximately 40 h on a 24-core computer. For the optimized 7-mm model, a simulation of all beamlets in water was carried out including a linear scanning magnet calibration simulation. Finally, a back-of-envelope dose rate formalism was developed and used to estimate dose rate under various conditions. The optimized 5–, 7–, and 10-mm models had beamlet widths of 5.1 , 7.2 , and 10.1 mm 2 and dose rates of 3574, 6351, and 10 015 Gy/C, respectively. The reduction in dose rate for smaller beamlet widths is a result of both increased collimation and source occlusion. For the simulation of all beamlets in water, the scanning magnet calibration reduced the offset between the collimator channels and beam centroids from 2.9 ±1.9 mm to 0.01 ±0.03 mm. A slight reduction in dose rate of approximately 2% per degree of scanning angle was observed. Based on a back-of-envelope dose rate formalism, SPHINX in conjunction with next-generation linear accelerators has the potential to achieve substantially higher dose rates than conventional MLC-based delivery, with delivery of an intensity modulated 100 x 100 mm 2 field achievable in 0.9 to 10.6 s depending on the beamlet widths used. Bayesian optimization was coupled with Monte Carlo modeling to generate SPHINX geometries for various beamlet widths. A complete Monte Carlo simulation for one of these designs was developed, including electron beam transport of all beamlets through scanning magnets, x-ray production and collimation, and dose in water. These results demonstrate that SPHINX is a promising candidate for sculpting radiation dose with no moving parts, and has the potential to vastly improve both the speed and robustness of radiotherapy delivery. A multi-beam SPHINX system may be a candidate for delivering magavoltage FLASH RT in humans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advances in ultrafast gas-phase x-ray scattering

Recent developments of x-ray free electron lasers and pulsed electron sources have enabled ultrafast scattering to become an increasingly powerful tool for exploring molecular dynamics. Here, this article describes our recent experimental and methodological advances in ultrafast gas-phase x-ray scattering experiments at the LCLS. A re-designed short-pathlength windowless diffractometer is coupled with careful optimization of sample density and independent normalization of x-ray intensity fluctuations to provide gas-phase scattering patterns with exceptionally high signal-to-noise ratios. These advances, coupled with careful geometry optimization and data treatment, provide both ground- and excited-state signals in excellent agreement with high level ab initio total scattering patterns.

74 ATOMIC AND MOLECULAR PHYSICS↗

VERITAS : A density-functional theory-based multiband kinetic model for understanding x-ray spectroscopy of dense plasmas

X-ray spectroscopy has long been a powerful diagnostic tool for hot, dilute plasmas, providing insights into plasma conditions by measuring line shifts and broadenings of atomic transitions. The technique critically depends on the accuracy of atomic physics models used to interpret spectroscopic measurements for inferring plasma properties such as free-electron density and temperature. Over the past decades, the atomic and plasma physics communities have developed robust atomic physics models to account for various processes in hot, dilute classical plasmas. While these models have been successful in that regime, their applicability becomes uncertain when interpreting x-ray spectroscopy experiments of above-solid-density plasmas. Given that finite-temperature density-functional theory (DFT) offers a more accurate description of dense plasma environments, we present the development of a DFT-based multi-band kinetic model, VERITAS, designed to improve the interpretation of x-ray spectroscopic measurements in high-density plasmas produced by laser-driven spherical implosions. This work details the VERITAS model and its application to both time-integrated and time-resolved x-ray spectra from implosion experiments on OMEGA. The advantages and limitations of the VERITAS model will also be discussed, along with potential directions for advancing x-ray spectroscopy of dense and superdense plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗