Search NASA⌕ Search

SEARCH · Search NASA

Results for “ZONES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Structure of the Melajo clay near Arima, Trinidad and strike-slip motion in the El Pilar fault zone

No consensus has yet emerged on the sense, timing and amount of motion in the El Pilar fault zone. As a contribution to the study of this problem, a critical area within the zone in North Central Trinidad has been mapped. On the basis of the mapping, it is concluded that the El Pilar zone has been active in right-lateral strike-slip motion during the Pleistocene. Recognition of structural styles akin to those of the mapped area leads to the suggestion that the El Pilar zone is part of a 300 km wide plate boundary zone extending from the Orinoco delta northward to Grenada. Lateral motion of the Caribbean plate with respect to South America has been suggested to amount to 1900 km in the last 38 Ma. Part of this displacement since the Miocene can be readily accommodated within the broad zone identified here. No one fault system need account for more than a fraction of the total motion and all faults need not be active simultaneously.

Robertson, P.↗

Distribution of flares on the sun - Superactive regions and active zones of 1980-1985

The author analyzed coordinates of energetic solar flares observed with the hard X-ray burst spectrometer during the period from February 1980 through August 1985. A small number of 'superactive regions' produced the majority of the major flares during this period. There exist active zones, in which the flare occurrence rate is much higher. Two active zones are in the northern hemisphere, and two are in the southern hemisphere. The longitudinal separation of the two active zones in the same hemisphere is about 180 deg, but tha active zones of the southern hemisphere are misaligned from those of the northern hemisphere by about 80 deg. The rotation period of the active zones is 26.75 d. Active zones last several years or longer. There is a hint of active centers rotating at a period of 23.7 d.

Bai, Taeil↗

A high-resolution local network study of the Nazca plate Wadati-Benioff zone under western Argentina

Seismic data, recorded by INPRES telemetered network located above one of the subhorizontal segments of the subducted Nazca plate Wadati-Benioff zone beneath western Argentina, were analyzed to determine the zone's fine structure. The depth of the center and the thickness of the subhorizontal Wadati-Benioff zone beneath the network were calculated to be about 107 km and about 20 km, respectively, with most of the seismogenic zone concentrated in a region about 12 km thick. The Nazca plate is interpreted to be in a state of down-dip tension and to be decoupled from the overriding South American plate by a weak zone of asthenospheric or shear-heated material. The South American plate is estimated to be 80 km thick, based on the location of the subducted Nazca plate and an inferred decoupling zone between the plates.

Smalley, Robert F., Jr.↗

A knowledge-based approach to automated flow-field zoning for computational fluid dynamics

An automated three-dimensional zonal grid generation capability for computational fluid dynamics is shown through the development of a demonstration computer program capable of automatically zoning the flow field of representative two-dimensional (2-D) aerodynamic configurations. The applicability of a knowledge-based programming approach to the domain of flow-field zoning is examined. Several aspects of flow-field zoning make the application of knowledge-based techniques challenging: the need for perceptual information, the role of individual bias in the design and evaluation of zonings, and the fact that the zoning process is modeled as a constructive, design-type task (for which there are relatively few examples of successful knowledge-based systems in any domain). Engineering solutions to the problems arising from these aspects are developed, and a demonstration system is implemented which can design, generate, and output flow-field zonings for representative 2-D aerodynamic configurations.

Vogel, Alison Andrews↗

Geoid anomalies over two South Atlantic fracture zones

Seasat altimetry profiles across the Falkland-Agulhas and Ascension fracture zones were examined for evidence of step-like geoid offsets predicted from thermal modeling of the lithosphere. Neither the plate nor the half-space model of lithospheric thermal evolution succeeds in predicting the variations in step height with age across the fracture zone branches considered. For ages less than about 30 Ma, the step offsets decrease in a manner suggesting a plate with a thickness of 50-75 km. At greater ages, the offsets show complex behavior that may be due to bathymetric features adjacent to the fracture zones. Similar geoid patterns on opposite branches of the Falkland-Agulhas fracture zone are indicative of processes that act symmetrically on both sides of the Mid-Atlantic Ridge. This is consistent both with small-scale convection occurring beneath the lithosphere and with bathymetric features originally produced along the ridge crest and now located symmetrically on opposite sides of the ridge. The west flank of the Ascension fracture zone displays a regrowth in step height at about 40 Ma consistent with small-scale convection and in agreement with other studies of Pacific and South Atlantic fracture zones.

Freedman, Adam P.↗

Numerical simulations of inductive-heated float-zone growth

The present work provides an improved fluid flow and heat-transfer modeling of float-zone growth by introducing a RF heating model so that an ad hoc heating temperature profile is not necessary. Numerical simulations were carried out to study the high-temperature float-zone growth of titanium carbide single crystal. The numerical results showed that the thermocapillary convection occurring inside the molten zone tends to increase the convexity of the melt-crystal interface and decrease the maximum temperature of the molten zone, while the natural convection tends to reduce the stability of the molten zone by increasing its height. It was found that the increase of induced heating due to the increase of applied RF voltage is reduced by the decrease of zone diameter. Surface tension plays an important role in controlling the amount of induced heating. Finally, a comparison of the computed shape of the free surface with a digital image obtained during a growth run showed adequate agreement.

Chan, Y. T.↗

Belt-zone variations in the Jovian cloud structure

Voyager Infrared Interferometer Spectrometer (IRIS) observations of Jupiter in the far infrared (180-1200/cm) are sensitive to emission originating from pressures less than 2 bars, while the 5-micrometer (1800-2300/cm) observations are primarily sensitive to emission originating from pressures greater than 2 bars. We use these differences in the location of the peak emission level to constrain the properties of the upper tropospheric cloud structure from the far-infrared observations and then use the 5-micrometer observations, with the upper tropospheric cloud structure fixed, to constrain the deep cloud structure. The relationship between observed 45- and 5-micrometer brightness temperatures reveals three distinct regions between +/- 25 deg latitude: North Equatorial Belt hot spots, which are 'hot' at both 45 and 5 micrometers; Equatorial Zone spectra, which are 'warm' at 45 micrometers and 'cold' at 5 micrometers; and North Tropical Zone spectra, which are 'cold' at both 45 and 5 micrometers. We find that the hot extreme spectral ensemble is unique to belts, and the cold extreme spectral ensembles are unique to zones, but that all other intermediate spectral ensembles are common to both regions. Analyses of these spectra using an anisotropic multiple scattering radiative transfer model reveal that the primary difference between belts and zones is the increased opacity and vertical extent of clouds in zones relative to their belt counterparts. In addition, we find a shift in the location of the para hydrogen gradient toward lower pressures in zones, with an increase in the 'equilibrated' cloud-top para fraction. We suggest that all of the variations in gas abundance profiles, temperature, and cloud structure are consistent with the effects of a simple mean circulation and large-scale wave motions.

Carlson, Barbara E.↗

Thermocapillary Convection in Floating Zones under Simulated Reduced-Gravity Conditions

The objective was to study thermocapillary convection in a transparent floating zone. The floating zone process is a unique process for crystal growth in that the melt is free from contamination by a crucible. Microgravity is ideal for the floating zone process because there is no significant gravity to cause the molten zone to collapse as under normal gravity. Since gravity-induced buoyancy convection is suppressed, surface- tension-induced thermocapillary convection dominates in the molten zone. In floating zone crystal growth, thermocapillary convection can be strong enough to cause formation of dopant striations and a convex growth front - both are undesirable in crystal growth.

Kou, Sindo↗

Polar transport of 45Ca2+ across the elongation zone of gravistimulated roots

The movement of calcium across the elongation zone of gravistimulated primary roots of maize (Zea mays L.) was measured using 45Ca2+. Radioactive calcium was applied to one side of the elongation zone about 4 mm back from the root tip and the distribution of radioactivity across the root in the region of application was determined using scintillation spectrometry. The movement of 45Ca2+ across the elongation zone was non-polar in vertically oriented roots. In gravistimulated roots the movement of label was polarized with about twice as much label moving from top to bottom as from bottom to top. A variety of treatments which interfere with gravitropism was found to eliminate the polar movement of 45Ca2+ across the elongation zone. In maize cultivars which require light for gravitropic competency, dark grown roots exhibited neither gravitropism nor polar movement of 45Ca2+ across the elongation zone. Upon illumination the roots developed but gravitropic competency and gravity-induced polar movement of 45Ca2+ across the elongation zone. Similarly, roots of light-grown seedlings lost both gravitropic competency and 45Ca2+ transport polarity upon transfer to the dark. The results indicate a close correlation between calcium movement and gravitropism in primary roots in maize.

NASA Discipline Number 40-10↗

Transparent multi-zone crystal growth furnace and method for controlling the same

A crystal growth system, comprising: a furnace; a plurality of heating elements coupled to said furnace, each said plurality of heating elements defining a heat zone, each said heating element set to a desired temperature value; a plurality of thermocouples associated with respective heat zones to detect a temperature value; a translation system for passing an ampoule containing crystal growth material through said furnace into said heat zones and providing a positional location of said ampoule and; a multi-variable self-tuning temperature controller connected to said plurality of heating elements, said plurality of thermocouples and said translation system, said controller monitoring each said zone temperature value and upon considering the thermal interaction of heating zones and the moving thermal inertia of the ampoule, adjusting voltage input to said heat zones to obtain optimal crystal growth within said ampoule.

Duval, Walter↗

Transparent multi-zone crystal growth furnace and method for controlling the same

A crystal growth system, comprising: a furnace; a plurality of heating elements coupled to said furnace, each said plurality of heating elements defining a heat zone, each said heating element set to a desired temperature value; a plurality of thermocouples associated with respective heat zones to detect a temperature value; a translation system for passing an ampoule containing crystal growth material through said furnace into said heat zones and providing a positional location of said ampoule and; a multi-variable self-tuning temperature controller connected to said plurality of heating elements, said plurality of thermocouples and said translation system, said controller monitoring each said zone temperature value and upon considering the thermal interaction of heating zones and the moving thermal inertia of the ampoule, adjusting voltage input to said heat zones to obtain optimal crystal growth within said ampoule.

Duval, Walter↗

Fatigue Resistance of the Grain Size Transition Zone in a Dual Microstructure Superalloy Disk

Mechanical property requirements vary with location in nickel-based superalloy disks. To maximize the associated mechanical properties, heat treatment methods have been developed for producing tailored microstructures. In this study, a specialized heat treatment method was applied to produce varying grain microstructures from the bore to the rim portions of a powder metallurgy processed nickel-based superalloy disk. The bore of the contoured disk consisted of fine grains to maximize strength and fatigue resistance at lower temperatures. The rim microstructure of the disk consisted of coarse grains for maximum resistance to creep and dwell crack growth at high temperatures up to 704 C. However, the fatigue resistance of the grain size transition zone was unclear, and needed to be evaluated. This zone was located as a band in the disk web between the bore and rim. Specimens were extracted parallel and transverse to the transition zone, and multiple fatigue tests were performed at 427 and 704 C. Mean fatigue lives were lower at 427 C than for 704 C. Specimen failures often initiated at relatively large grains, which failed on crystallographic facets. Grain size distributions were characterized in the specimens, and related to the grains initiating failures as well as location within the transition zone. Fatigue life decreased with increasing maximum grain size. Correspondingly, mean fatigue resistance of the transition zone was slightly higher than that of the rim, but lower than that of the bore. The scatter in limited tests of replicates was comparable for all transition zone locations examined.

Gabb, T. P.↗

Investigating Some Technical Issues on Cohesive Zone Modeling of Fracture

This study investigates some technical issues related to the use of cohesive zone models (CZMs) in modeling fracture processes. These issues include: why cohesive laws of different shapes can produce similar fracture predictions; under what conditions CZM predictions have a high degree of agreement with linear elastic fracture mechanics (LEFM) analysis results; when the shape of cohesive laws becomes important in the fracture predictions; and why the opening profile along the cohesive zone length needs to be accurately predicted. Two cohesive models were used in this study to address these technical issues. They are the linear softening cohesive model and the Dugdale perfectly plastic cohesive model. Each cohesive model constitutes five cohesive laws of different maximum tractions. All cohesive laws have the same cohesive work rate (CWR) which is defined by the area under the traction-separation curve. The effects of the maximum traction on the cohesive zone length and the critical remote applied stress are investigated for both models. For a CZM to predict a fracture load similar to that obtained by an LEFM analysis, the cohesive zone length needs to be much smaller than the crack length, which reflects the small scale yielding condition requirement for LEFM analysis to be valid. For large-scale cohesive zone cases, the predicted critical remote applied stresses depend on the shape of cohesive models used and can significantly deviate from LEFM results. Furthermore, this study also reveals the importance of accurately predicting the cohesive zone profile in determining the critical remote applied load.

Wang, John T.↗

The Evolution of a Circumplanetary Disc with a Dead Zone

We investigate whether the regular Galilean satellites could have formed in the dead zone of a circumplanetary disc. A deadzone is a region of weak turbulence in which the magnetorotational instability is suppressed, potentially an ideal environmentfor satellite formation. With the grid-based hydrodynamic codeFAR GO3D, we examine the evolution of a circumplanetary discmodel with a dead zone. Material accumulates in the dead zone of the disc leading to a higher total mass and but a similartemperature profile compared to a fully turbulent disc model. The tidal torque increases the rate of mass transport through thedead zone leading to a steady-state disc with a dead zone that does not undergo accretion outbursts. We explore a range of disc,dead zone, and mass inflow parameters and find that the maximum mass of the disc is around 0.001MJ. Since the total solidmass of such a disc is much lower, we find that there is not sufficient material in the disc forin situformation of the Galileansatellites and that external supplement is required.

Cheng Chen↗

Variable power distribution for zoned regeneration of an electrically heated particulate filter

A system includes a particulate matter (PM) filter with multiple zones, an electric heater and a control module. The electrical heater includes heater segments, which each correspond with a respective one of the zones. The electrical heater is arranged upstream from and is proximate with the PM filter. The control module selectively applies a first energy level to a first one of the zones via a first one of the heater segments to initiate regeneration in the first zone. The control module also selectively applies a second energy level that is less than the first energy level to a second one of the zones via a second one of the heater segments to initiate regeneration in the second zone.

42 ENGINEERING↗

Potential impacts of climate change on the built environment: ASHRAE climate zones, building codes and national energy efficiency

Statement of the Problem: ASHRAE releases updates to 90.1 “Energy Standard for Buildings except Low-Rise Residential Buildings” every three years resulting in a 3.7%-17.3% increase in energy efficiency for buildings with each release. This is adopted by or informs building codes in nations across the globe, is the National Standard for the US, and individual states elect which release year of the standard they will enforce. These codes are built upon Standard 169 “Climatic Data for Building Design Standards,” the latest 2017 release of which defines climate zones based on 8, 118 weather stations throughout the world and data from the past 8-25 years. This data may not be indicative of the weather that new buildings built today, will see during their upcoming 30-120 year lifespan. Methodology & Theoretical Orientation: Using more modern, high-resolution datasets from climate satellites, IPCC climate models (PCM and HadGCM), high performance computing resources (Titan) and new capabilities for clustering and optimization the authors briefly analyzed different methods for redefining climate zones. Using bottom-up analysis of multiple meteorological variables which were the subject matter, experts selected as being important to energy consumption, rather than the heating/cooling degree days currently used. Findings: We analyzed the accuracy of redefined climate zones, compared to current climate zones and how the climate zones moved under different climate change scenarios, and quantified the accuracy of these methods on a local level, at a national scale for the US. Conclusion & Significance: There is likely to be a significant annual, national energy and cost (billions USD) savings that could be realized by adjusting climate zones to take into account anticipated trends or scenarios in regional weather patterns.

New, Joshua Ryan↗

Deep Vadose Zone Characterization at the Hanford Site: Accomplishments from the Last Ten Years

The overall goal of the Tank Farm Vadose Zone Project, led by CH2M HILL Hanford Group, Inc., is to define risks from past and future single-shell tank farm activities at Hanford. To meet this goal, CH2M HILL Hanford Group, Inc. tasked scientists from Pacific Northwest National Laboratory (PNNL) to perform detailed analyses on vadose zone sediments collected within/adjacent to the twelve single-shell tank farms contained within Hanford's Central Plateau region. This work has been performed under the Resource Conservation and Recovery Act (RCRA) Corrective Action Program and is associated with the Hanford Federal Facility Agreement and Consent Order. While there are many facets to the laboratory studies employed by PNNL, the four primary objectives of this work are to: identify the type and quantity of contamination present, understand the physical processes that affect the transport of contaminants in the vadose zone sediments, when practical, identify the source(s) of the contamination found in the sediment samples, and when practical, determine if a link can be made between the vadose zone contamination observed and any known groundwater contaminants in the vicinity. Since its inception in 1997, PNNL's Vadose Zone Characterization Project has evolved to better meet these four key objectives. The single-largest adaptation of the Vadose Zone Characterization Project over its ten years of operation was the advent of a tiered sample analysis approach. Use of a tiered approach allows resources to be focused on those samples/tests that provide the largest amount of scientific information to best meet the four key project objectives within the budget available. Another significant, but more recent, adaptation has been the implementation of a rapid turnaround characterization process in which sediment samples are analyzed in near real-time to aid drilling activities within the tank farms. This paper highlights details of the characterization activities performed as well as significant findings from the last ten years. (authors)

54 ENVIRONMENTAL SCIENCES↗

Concluding a steam injection remediation project at a dense non-aqueous phase liquid source zone at the Savannah River site - 15303

Multiple subsurface dense non-aqueous phase liquid (DNAPL) source zones served as the sources for a groundwater plume within the A/M Area of the Savannah River Site. Between 1952 and 1985 over 1,600 metric tons of trichloroethylene, tetrachloroethylene, and 1,1,1-trichloroethane were released to the environment resulting in a 648 hectare plume with the M-Area Settling Basin receiving over half of the solvent discharges. In 1991, DNAPL was found in a water table well and steam injection technology was selected to remediate the source zone. Based on characterization data, the treatment area was 1.21 hectare with depths between 13.7 to 50.3 m. The remediation system included 96 vertical, horizontal, and angled steam injection and soil vapor extraction wells and a thermal monitoring system. Construction of the system began in 2004 and operation began in 2005. Steam was applied to the deep vadose zone first, then progressed to the aquifer, followed by the mid-vadose zone. Multiple steam strategies were utilized to enhance mass removal and were concluded in 2009. Soil vapor extraction continues, with residual temperatures in the deep permeability zones still exceeding 65 deg.C. To date over 204 metric tons of volatile organic compounds (VOCs) have been removed. Post-remediation soil, vapor, temperature, and groundwater data were used to evaluate steam injection effectiveness and demonstrated significant reduction in soil concentration, including removal of DNAPL that was evident in several soil cores prior to treatment. Heating the subsurface increased VOC solubility in groundwater and increased mass removal rates outside the target zone. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗