Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Characterization of Self-Magnetic Pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories: 1) Diode Dynamics, DC Heating to extend Radiation Pulse

Radiographic diodes focus an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the RITS-6 Inductive Voltage Adder (IVA) driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode-cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analyzation of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below ~ few mm. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle-behavior of SMP shots is made to lend credence to the inference. There is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of target irradiation and diagnostic chamber to study ps-laser generated plasma as a source of singly charged ions for external injection into an electron beam ion source

High repetition-rate (~10 kHz) ps-lasers are becoming available on the market with reasonable cost and may offer several advantages compared to ns-lasers by generating nearly continuous beams of singly charged ions appropriate for the “slow” injection mode into the Electron Beam Ion Source (EBIS). To evaluate these advantages, we will perform studies of a ps-laser generated plasma using a laser with a pulse duration of 8 ps and energy up to 5 mJ per pulse. A vacuum chamber equipped with a 3D target positioner, a focusing lens, and a Faraday Cup has been designed and built for this study. Lens-to-target distance variations have been measured using a laser tracker over the whole range of horizontal and vertical translation for all five targets we will use. The variations were found to be within ±150 µm. This level of “target flatness” should be acceptable for our experimental conditions. Ion currents and ion pulse durations of various elements (from Al to Ta) will be measured for different target irradiation conditions (focal spot size and laser pulse energy). The results obtained will allow us to specify all parameters and geometry of a laser ion source based on a ps-laser to provide external ion injection into the relativistic heavy ion collider EBIS

43 PARTICLE ACCELERATORS↗

High precision magnetic field measurement and mapping of the LEReC 180 degree bending magnet using very low field NMR with hall combined probe (140 - 350 gauss)

The Relativistic Heavy Ion Collider (RHIC) at BNL are using the Low Energy RHIC Electron Cooling (LEReC) to conduct experiments that search for the quantum chromodynamic (QCD) critical point. The first ever electron cooling based on the RF acceleration of electron beams was experimentally demonstrated on April 5, 2019 at LEReC at BNL. The first critical step in obtaining successful 3D non-magnetized cooling of the Au ion bunches in the RHIC cooling section was matching the electron beam energy with a relative error less than 5*10 -4 to the ion beam energy. Part of the LEReC beamline is a dipole magnet that bends the electron beam 180 degree. One of the most outstanding measurement challenges is that the dipole field is so low (≈200 G). Most of the existing NMR probes can only measure fields >400 G. Lower signal-to-noise ratio at low fields is requires the use of larger sample volumes. Working with CAYLAR, a NMR probe has been redesigned and optimized for these low field measurements with high resolution. We report the methods, challenges, and results for extensive magnetic field mappings of the 180 dipole magnet. A combination of NMR and Hall sensors has been successfully implemented to measure uniform field regimes inside the magnet center area and non-uniform field regimes at the magnet ends. Detailed measurement and mapping have been performed at five radii and five heights along the beam trajectory. Meanwhile a finite element magnetic modeling simulation of the magnet using Opera software has been performed. The calculated and measured data are compared, and the calculated data is good reference for measured data over long length mapping from magnet edge to center. The measured magnetic measurement data is directly useful for beam instrumentation, diagnostics and operation.

Magnetic Field Measurement↗

Thermal and electromechanical response of ultra-thin carbon-strip polarimeter targets in relativistic bunched beams

Thin carbon-strip targets provide fast relative hadron beam polarimetry, but their response in intense relativistic bunched beams is not governed by local stopping-power heating alone. We develop a coupled response model that combines beam-target overlap, secondary-electron escape, retained heat, target motion, transient heat transport, RF-induced strip-end heating, beam-induced forces, resistance changes, and slack-strip deformation. RHIC target observations constrain the relevant motion, force, and nonlocal-heating scales and show that target survival depends on both beam-center heating and electromagnetic boundary conditions near the strip ends. Applying the model to Booster, AGS, RHIC, and EIC proton and 3 He cases shows that the RHIC proton lifetime scale is reproduced at the order-of-magnitude level, while the RHIC target-holder fin results require the additional RF/end-heating mechanism. For EIC proton flattop operation, carbon-strip polarimetry may remain viable only with reduced dwell time, sufficient detector acceptance, and suppression of RF-induced end heating. For cooled-emittance 3 He, the calculated sublimation-loss scale is far beyond a straightforward RHIC-like carbon-strip extrapolation. Conventional carbon strips are therefore unlikely to remain viable for the most demanding EIC light-ion cases without major changes in target motion, target technology, or diagnostic concept.

43 PARTICLE ACCELERATORS↗

Four-dimensional emittance measurement at the Spallation Neutron Source

A coasting hadron beam with an elliptical transverse profile, uniform charge density, and small transverse four-dimensional (4D) emittance could improve accelerator performance in several contexts. A phase space painting method to generate such a distribution is being tested in the Spallation Neutron Source (SNS) accumulator ring. A critical component of these efforts is to measure the 4D emittance of the beam during accumulation. The 4D emittance can be reconstructed from measured beam profiles in two ways: in the multi-optics method, the optics between a reconstruction and measurement location are varied; in the fixed-optics method, multiple measurement locations are used without modifying the optics. The fixed-optics method is faster but can lead to large uncertainty in the reconstructed 4D emittance. In this paper, we implement a variant of the multi-optics method using the four available wire-scanners near the SNS target. We also modify the wire-scanner region to reduce the uncertainty of the fixed-optics method. We then demonstrate the usefulness of the fixed-optics method by reconstructing the 4D emittance evolution during accumulation in the SNS ring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of self-magnetic pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories. I. Diode dynamics, DC heating to extend radiation pulse

Radiographic diodes focus on an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the six-cavity radiographic integrated test stand (RITS-6) inductive voltage adder driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode–cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analysis of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below approximately few millimeters. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle behavior of SMP shots is made to lend credence to the inference. We report there is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sub-THz passive detector performance evaluation with RadiaBeam photoinjector

Wakefield accelerators, based on THz and mm-wave structures, promise to reach the highest energies in record small footprints. However, operation at such frequencies is associated with strong generation of dipole modes that can destroy the beams, which requires controlling the electron beam position at the micron scale. The existing conventional techniques for electron beam position monitoring are not applicable for sub-THz structures due to the space constraints. Here, on the other hand, if dipole modes amplitudes can be measured precisely at different planes, one can derive beam position relative to the central axis. For such a technique a reliable and cost-effective sensor capable of operating in high repletion rate regime is required. In this paper we review the experimental evaluation of a passive sensor candidate for such applications using RadiaBeam 4.5 MeV photoinjector.

Accelerator↗

Direct determination of the temperatures of the Carbon targets at the CNI polarimeters in RHIC when hit by the proton beam

Up to now, the temperatures of the carbon fiber targets used in the RHIC CNI polarimeters during proton beam interactions cannot be directly measured, yet their survival indicates that they remain below the sublimation threshold of Tsub = 3915 K. This study investigates the feasibility of using light emission as a diagnostic tool to determine the target temperatures. A dedicated optical light collection system was implemented in IP12 to capture and analyze emitted light across the visible and near-infrared spectrum. This note focuses on the initial results from the RHIC run 24 and outlines the next steps for further investigation during run 25. A proposal for an APEX run [1] was submitted as an option in case a dedicated proton beam is not available during run 25. This work is critical for assessing the applicability of carbon fiber targets in the Electron-Ion Collider (EIC) under increased beam currents.

43 PARTICLE ACCELERATORS↗

Tomography of longitudinal phase space linearization for the generation of attosecond electron bunches

The generation of electron bunches on the attosecond timescale is important for a multitude of accelerator-based applications. Here, we report on a tomographic measurement of the (pre)linearized longitudinal phase space of a low charge 3 MeV electron bunch generated with the 1.6 cell Pegasus photoinjector for the generation of attosecond bunches. The nonlinear correlations in the longitudinal phase space induced by space charge at the photocathode, radiofrequency field curvature of the gun, and vacuum dispersion are compensated using a compact X-band linearizer. Then, the initial and compensated phase of the picosecond electron bunch is precisely reconstructed by neural network assisted tomographic reconstruction from momentum spectra at varying buncher linac phase. Finally, we combine the measured phase space shape with particle tracking simulations to show that electron bunches as short as 941 as develop downstream the beamline.

Beam control↗

Physical thickness characterization of the FRIB production targets

The FRIB heavy-ion accelerator, commissioned in 2022, is a leading facility for producing rare isotope beams (RIBs) and exploring nuclei beyond the limits of stability. These RIBs are produced via reactions between stable primary beams and a graphite target. Approximately 20–40% of the primary beam power is deposited in the target, requiring efficient thermal dissipation. Currently, FRIB operates with a primary beam power of up to 20 kW. To enhance thermal dissipation efficiency, a single-slice rotating graphite target with a diameter of approximately 30 cm is employed. The effective target region is a 1 cm-wide outer rim of the graphite disc. To achieve high RIB production rates, the areal thickness variation must be constrained within 2%. This paper presents physical thickness characterizations of FRIB production targets with various nominal thicknesses, measured using a custom-built non-contact thickness measurement apparatus.

Instrumentation for radioactive beams (fragmentati↗

Simultaneous measurements of unstable and stable Alfvén eigenmodes in JET

Here, we report the novel experimental observation of both unstable and stable toroidicity-induced Alfvén eigenmodes (TAEs) measured simultaneously in a JET tokamak plasma. The three-ion-heating scheme (D-DNBI-3He) is employed to accelerate deuterons to MeV energies, thereby destabilizing TAEs with toroidal mode numbers n = 3–5, each decreasing in mode amplitude. At the same time, the Alfvén eigenmode active diagnostic resonantly excites a stable n = 6 TAE with total normalized damping rate –γ/ω 0 ≈ 1%–4%. Hybrid kinetic-MHD modeling with codes NOVA-K and MEGA both find eigenmodes with similar frequencies, mode structures, and radial locations as in experiment. NOVA-K demonstrates good agreement with the n = 3, 4, and 6 TAEs, matching the damping rate of the n = 6 mode within uncertainties and identifying radiative damping as the dominant contribution. Improved agreement is found with MEGA for all modes: the unstable n = 3–5 and stable n = 2, 6 modes, with the latter two stabilized by higher intrinsic damping and lower fast ion drive, respectively. While some discrepancies remain to be resolved, this unique validation effort gives us confidence in TAE stability predictions for future fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proton stopping measurements at low velocity in warm dense carbon

Abstract Ion stopping in warm dense matter is a process of fundamental importance for the understanding of the properties of dense plasmas, the realization and the interpretation of experiments involving ion-beam-heated warm dense matter samples, and for inertial confinement fusion research. The theoretical description of the ion stopping power in warm dense matter is difficult notably due to electron coupling and degeneracy, and measurements are still largely missing. In particular, the low-velocity stopping range, that features the largest modelling uncertainties, remains virtually unexplored. Here, we report proton energy-loss measurements in warm dense plasma at unprecedented low projectile velocities. Our energy-loss data, combined with a precise target characterization based on plasma-emission measurements using two independent spectroscopy diagnostics, demonstrate a significant deviation of the stopping power from classical models in this regime. In particular, we show that our results are in closest agreement with recent first-principles simulations based on time-dependent density functional theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Niowave Neutron Source Converter: Lead-Bismuth-Eutectic (LBE) Windowless Target Design and Evaluation

Los Alamos National Laboratory (LANL) is working with Niowave on the design and evaluation of their lead-bismuth-eutectic (LBE) windowless target (i.e., neutron source converter). Niowave plans to use 200 kW electron beam at 40 MeV beam energy to produce neutrons by photonuclear reaction with LBE. Then, the neutrons undergo fission at the surrounding uranium target assembly (UTA) to produce Molybdenum 99 (Mo-99) as a fission product, which eventually decays to Technetium-99 (Tc-99m). Tc-99m is one of important radioisotopes that is used for medical diagnostics. LANL conducted 3D multiphysics analysis for the Niowave neutron converter design and provided design assessment in thermohydraulic aspects. LANL conducted radiation transport calculations using Monte-Carlo N-Particle (MCNP) code with unstructured meshing scheme. The 3D volumetric heating profiles in the LBE and Stainless-Steel (SS) housing were imported into multiphase computational fluid dynamics (CFD) to obtain 3D temperature profiles of LBE and SS through conjugate heat transfer (CHT) analysis. The key findings are: LBE film thickness at the center of the beam is approximately 1.6 cm with a maximum LBE velocity of approximately 1.8 m/s, which is below a 2 m/s limit to avoid erosion issues on supporting structures; Heat deposition in the LBE peaks at ~1 cm depth from the LBE free-surface because of the forward interactions of electron, photon, and neutron with LBE; LBE maximum temperature is ~360 °C, which is below LBE evaporation initiative temperature, ~450 °C; LBE-SS interface temperature is ~350 °C, which is below the safety thermal limit to prevent severe corrosion on SS. The results indicate that Niowave’s neutron converter design satisfies both hydraulic and thermal criteria for safe operation. By virtue of such computational analysis, Niowave can move toward establishing an experimental setup to experimentally test their LBE neutron converter. The following sections describe the detailed work done by LANL.

43 PARTICLE ACCELERATORS↗

Real-time plasma monitoring framework for advanced plasma control and ML-research in DIII-D

Real-time and adaptive plasma control is crucial for robust tokamak operation, requiring sensitivity and tolerance measurements of the plasma state. This paper presents the implementation of an integrated real-time plasma monitoring framework on the DIII-D tokamak to support advanced control approaches, including machine-learning (ML) methods. The system is built on the SHIELD framework, a high-performance modular architecture that provides a unified pipeline for integrating diverse diagnostics. The framework leverages high-bandwidth digitizers, fast numerical processing, and deterministic, low-latency interconnects to stream high-fidelity data from diagnostics such as electron cyclotron emission (ECE), beam emission spectroscopy (BES), CO interferometers, and a visible tangential divertor camera (TangTV). The system’s validity is demonstrated through direct comparisons of real-time and offline data. Furthermore, we present two key applications of the developed plasma monitoring system with ML-based plasma control strategies, including real-time divertor detachment and active Alfvén Eigenmode control. As a result, this work presents a robust and scalable approach for integrating high-frequency, multidimensional diagnostics into advanced control algorithms for future fusion devices.

AI/ML↗

ESTIMATION OF THE WAKEFIELD RESONANT FREQUENCY USING DIFFERENT SIMULATION TOOLS

Reliable and fast wakefield calculations are important for beam dynamics and THz generation in accelerators. We compare approaches and limitations with different available simulation tools and compare results. As an example, we analyse a cylindrical corrugated waveguide with narrower and wider radii of 5 and 6 mm, and aperture width and periodicity of 1 and 2 mm using ABCI by KEK and ANSYS HFSS simulation software. First, ABCI was used to determine the resonant frequency of the cylindri-cal corrugated waveguide with different lengths. The corresponding results were taken as a reference to exam-ine the simulation method in the ANSYS HFSS environ-ment. The eigenmode solver of ANSYS HFSS was used to determine different resonant frequencies. This was fol-lowed by examining a cylindrical corrugated waveguide that was implemented having a length of 17 mm for dif-ferent conductor settings. The corresponding waveguide was fed by a plane wave having a resonant frequency that satisfies the intersection of the light line and dispersion curve of the corresponding mode. The analysis showed that the maximum loss factor was achieved at 39.20 and 40.07 GHz using ANSYS HFSS simulation data for differ-ent conductors, whereas ABCI resulted in 38.50 GHz. The talk will present the results gathered by different simula-tion setups implemented in ANSYS HFSS.

Unutmaz, Muhammed [SLAC National Accelerator Labor↗

Performance of the MICE diagnostic system

Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams of a neutrino factory and for multi-TeV lepton-antilepton collisions at a muon collider. The international Muon Ionization Cooling Experiment (MICE) has demonstrated the principle of ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. This paper documents the performance of the detectors used in MICE to measure the muon-beam parameters, and the physical properties of the liquid hydrogen energy absorber during running.

43 PARTICLE ACCELERATORS↗

Demonstration of a code coupling framework for modeling beam-collimator impacts in the advanced photon source

The high-brightness beams being produced in current and future accelerators present new machine protection concerns with the potential for high-energy-density (HED) conditions ( >100 J/mm 3 ) in beam-intercepting components. Simulating HED conditions in accelerators requires utilizing a suite of physics codes for particle dynamics, particle-matter interactions, and hydrodynamics. This paper describes a method of coupling the codes elegant, fluka, and flash to simulate the effects of a rapid beam loss in the advanced photon source storage ring and the resulting interaction of the beam and collimators. This paper expands previous work [J. Dooling et al., Collimator irradiation studies at the advanced photon source, in Proceedings of the IBIC-2023 (2023), pp. 245–249] by introducing a definition of the evolving geometry of the collimator surface as well as providing methods for simulating the absorption of synchrotron radiation and tracking shower particles produced during beam strikes. We demonstrate this framework by simulating machine conditions of the APS ring before and after its recent upgrade. Simulation results are compared with observed damage to collimators and test samples taken from the APS ring.

Accelerator/storage ring control systems↗

Reconstruction of beam parameters and betatron radiation spectra measured with a Compton spectrometer

The photon flux resulting from high-energy electron beam interactions with high-field systems, such as those found in the upcoming FACET-II experiments at the SLAC National Accelerator Laboratory, yields deep insight into the electron beam’s underlying dynamics during the interaction. However, extracting this information is an intricate process. To demonstrate how to approach this challenge using modern methods, this paper utilizes simulated data that models plasma wakefield acceleration-derived betatron radiation in experiments to determine reliable methods of reconstructing key beam and beam-plasma interaction properties. For betatron radiation measurements, translating the observed 200⁢ keV to 30⁢ MeV photon double-differential energy-angle spectra obtained from an advanced Compton spectrometer requires testing multiple methods to optimize the pipeline from its response to incident electron beam information. The paper compares maximum likelihood estimation and machine learning to refine the translation of photon spectra into precise electron beam metrics, such as spot size, energy, and emittance, enhancing the understanding of beam behavior within these dense, high-field environments. We also introduce machine learning and the expected maximization algorithm to reconstruct the primary photon spectrum, employing a multilayer neural network for regression analysis of the energy and angle spectra. With appropriate modifications, the advanced methods reproduce relevant incident beam parameters with high accuracy, even for beam sizes in the <10 μ⁢m range. This capacity is critical to understanding intense beam propagation and its optimization in plasma.

Beam code development & simulation techniques↗