Search NASA⌕ Search

SEARCH · Search NASA

Results for “acquisition function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Frequency discriminator/phase detector

Circuit provides dual function of frequency discriminator/phase detector which reduces frequency acquisition time without adding to circuit complexity. Both frequency discriminators, in evaluated frequency discriminator/phase detector circuits, are effective two decades above and below center frequency.

Crow, R. B.↗

Analysis of Doppler lidar wind measurements

New analysis methods were developed and refined for the synthesis of wind fields from multiple Doppler radar data. Considerable software was written and debugged for wind field synthesis. The analysis methods were applied to radar data collected during the CCOPE experiment in which lidar wind measurements were also made. The analysis method differs from existing methods in that interpolation (using filters with assigned weights) and advection of data, to account for time differential between data acquisition at different points, are not used. Instead, functional fits were used in space and time coordinates to transfer radial velocity data to a space-time grid. Subsequently the wind synthesis is performed. This method gives better space resolution in the synthesized winds, compared to other methods in common use, by better preserving the gradients of velocities. The wind fields show the cellular structure characteristic of boundary-layer convection. Also evident in the analysis are the sharp transitions and gradients in the wind field which were preserved by the synthesis.

Srivastava, R. C.↗

Army aviation today and tomorrow

Military helicopters and their functions in combat are described. Electronic countermeasures, target acquisition, surveillance, reconnaissance, weapons systems, night flight capability, troop transport, and nap-of-the-earth navigation are discussed.

Philips, G.↗

Studies on the Processing Methods for Extraterrestrial Materials

The literature was surveyed for high temperature mass spectrometric research on single oxides, complex oxides, and minerals in an effort to develop a means of separating elements and compounds from lunar and other extraterrestrial materials. A data acquisition system for determining vaporization rates as a function of time and temperature and software for the IEEE-488 Apple-ORTEC interface are discussed. Experimental design information from a 1000 C furnace were used with heat transfer calculations to develop the basic design for a 1600 C furnace. A controller was built for the higher temperature furnace and drawings are being made for the furnace.

Grimley, R. T.↗

Development of a facility using robotics for testing automation of inertial instruments

The Integrated Robotics System Simulation (ROBSIM) was used to evaluate the performance of the PUMA 560 arm as applied to testing of inertial sensors. Results of this effort were used in the design and development of a feasibility test environment using a PUMA 560 arm. The implemented facility demonstrated the ability to perform conventional static inertial instrument tests (rotation and tumble). The facility included an efficient data acquisitions capability along with a precision test servomechanism function resulting in various data presentations which are included in the paper. Analysis of inertial instrument testing accuracy, repeatability and noise characteristics are provided for the PUMA 560 as well as for other possible commercial arm configurations. Another integral aspect of the effort was an in-depth economic analysis and comparison of robot arm testing versus use of contemporary precision test equipment.

Greig, Joy Y.↗

The Generic Data Capture Facility

The Generic Data Capture Facility, which can provide data capture support for a variety of different types of spacecraft while enabling operations costs to be carefully controlled, is discussed. The data capture functions, data protection, isolation of users from data acquisition problems, data reconstruction, and quality and accounting are addressed. The TDM and packet data formats utilized by the system are described, and the development of generic facilities is considered.

Connell, Edward B.↗

JPL control/structure interaction test bed real-time control computer architecture

The Control/Structure Interaction Program is a technology development program for spacecraft that exhibit interactions between the control system and structural dynamics. The program objectives include development and verification of new design concepts - such as active structure - and new tools - such as combined structure and control optimization algorithm - and their verification in ground and possibly flight test. A focus mission spacecraft was designed based upon a space interferometer and is the basis for design of the ground test article. The ground test bed objectives include verification of the spacecraft design concepts, the active structure elements and certain design tools such as the new combined structures and controls optimization tool. In anticipation of CSI technology flight experiments, the test bed control electronics must emulate the computation capacity and control architectures of space qualifiable systems as well as the command and control networks that will be used to connect investigators with the flight experiment hardware. The Test Bed facility electronics were functionally partitioned into three units: a laboratory data acquisition system for structural parameter identification and performance verification; an experiment supervisory computer to oversee the experiment, monitor the environmental parameters and perform data logging; and a multilevel real-time control computing system. The design of the Test Bed electronics is presented along with hardware and software component descriptions. The system should break new ground in experimental control electronics and is of interest to anyone working in the verification of control concepts for large structures.

Briggs, Hugh C.↗

Earth Orbiter 1: Wideband Advanced Recorder and Processor (WARP)

An advanced on-board spacecraft data system component is presented. The component is computer-based and provides science data acquisition, processing, storage, and base-band transmission functions. Specifically, the component is a very high rate solid state recorder, serving as a pathfinder for achieving the data handling requirements of next-generation hyperspectral imaging missions.

Smith, Terry↗

Earth Orbiter 1: Wideband Advanced Recorder and Processor (WARP)

An advanced on-board spacecraft data system component is presented. The component is computer-based and provides science data acquisition, processing, storage, and base-band transmission functions. Specifically, the component is a very high rate solid state recorder, serving as a pathfinder for achieving the data handling requirements of next-generation hyperspectral imaging missions.

Smith, Terry↗

Ultrasound Techniques for Space Applications

Ultrasound has proven to be a safe non-invasive technique for imaging organs and measuring cardiovascular function. It has unique advantages for application to problems with man in space including evaluation of cardiovascular function both in serial studies and during critical operations. In addition, specialized instrumentation may be capable of detecting the onset of decompression sickness during EVA activities. A spatial location and three-dimensional reconstruction system is being developed to improve the accuracy and reproducibility for serial comparative ultrasound studies of cardiovascular function. The three-dimensional method permits the acquisition of ultrasonic images from many views that can be recombined into a single reconstruction of the heart or vasculature. In addition to conventional imaging and monitoring systems, it is sometimes necessary or desirable to develop instrumentation for special purposes. One example of this type of development is the design of a pulsed-Doppler system to monitor cerebral blood flow during critical operations such as re-entry. A second example is the design of a swept-frequency ultrasound system for the detection of bubbles in the circulatory system and/or soft tissues as an early indication of the onset of decompression sickness during EVA activities. This system exploits the resonant properties of bubbles and can detect both fundamental and second harmonic emissions from the insonified region.

Rooney, James A.↗

Pros and Cons of Using Water Immersion to Simulate Physiological Responses to Microgravity

Head-out water immersion (HOI) has been employed as a remedial treatment for various ills and ailments for many millennia, and total body immersion even longer as protective encapsulation for the mammalian fetus. Two discrete differences between stimuli induced by true microgravity (10(exp -4) g) and HOI are readily apparent. External water pressure on the skin and accompanying negative pressure breathing cause blood to shift headward. Secondly, the gravitational force is ever present during immersion and microgravity, but its effect is essentially neutralized during Earth orbital flight. Thus, the physiological responses to immersion should not be expected to match those during microgravity. Immersion has been used mainly to study and understand kidney function and associated cardiovascular responses for control of body fluid volume and osmotic content, with some application to and simulation of microgravity responses. There is a plethora of data from human HOI studies, but relatively few controlled data from microgravity studies. In general, it appears that physiological responses occur more quickly with water immersion than in microgravity, but this may be due to less rigorous control (voluntary and involuntary) of the preflight state of crew members. The central venous pressure-vasopressin (Gauer-Henry) reflex control for fluid balance may not be of prime importance in microgravity. Gross functions such as reduced body weight and water, level of hypovolemia, decreased isokinetic strength, and lower nitrogen balance found during immersion are qualitatively similar in microgravity, but the mechanisms controlling these and other functions are, for the most part, unclear. Only acquisition of data from well-controlled microgravity experiments will resolve this discrepancy.

Greenleaf, J. E.↗

Progress on the Development of a Simulation Environment for Optical Communications

Deep space laser communications require extremely accurate beam pointing to take advantage of the narrow beams achievable at optical wavelengths. This pointing accuracy must be achieved in the presence of spacecraft basebody motion which may exceed laser pointing requirements by orders of magnitude.In this paper a model of an optical band transceiver pointing control system is developed that can be used to predict performance under various operating scenarios. The transceiver model consists of an electro-mechanical model of the telescope platform and isolator. A novel photon counting detector array is used in the simulation as the focal plane detector. In the simulation we are able to inject various cases of spacecraft basebody motion based on both flight data and future mission spacecraft jitter requirements. Various models of uplink beacon flux levels and atmospheric scintillation are also available for analysis.Using these models, detector processing and control functions are implemented in the simulation. A complete acquisition sequence is demonstrated with blind acquisition and tracking of the modulated uplink beam and positioning of the downlink beam on the focal plane array. These simulations predict that pointing requirements will be met with representative disturbance models and uplink beam scintillation.

pointing control↗

Earth/Moon System Star Tracking Sensor for Improved Deep Space Laser Communications

The goal of this research is to improve deep space communication links by exploring a new concept in stellar navigation that uses images of the Earth/Moon system to obtain precise pointing information so that the laser signal from the satellite can be directed at the ground station with unprecedented accuracy. Currently, the concept for satellite pointing relies on a dual axis star tracker that compares images of the celestial sphere to a star catalog to obtain a 3-axis orientation solution. Most star trackers are designed with a wide field of view (required to obtain enough bright starts to achieve a navigational fix) and only provide reliable pitch and yaw estimates thus necessitating the use of a second star tracker looking at an axis perpendicular to the first one to obtain an accurate estimate of the roll of the spacecraft. In the new concept the optical design will be modified to ensure that both the Earth and the Moon will be within a narrow field of view centered on Earth relative to the field of view of most star tracking systems. Because of the proximity of the bodies, it is possible to obtain highly accurate estimates of the pitch, yaw and roll of the spacecraft relative to the Earth/Moon system. The new tracker will allow for accurate 3-axis control of the spacecraft from a single tracker thus allowing the second star tracker, which would normally be pointed in a direction perpendicular to the one pointed at earth, to obtain the spacecraft roll estimate. This wide field star tracker facilitates functions like the initial satellite pointing during the acquisition phase of establishing the laser communication link or solving the lost in space problem should the system need to be reset. This new design will be tested in simulation and compared for 3-axis pointing accuracy against a standard commercial star tracker.

Star tracker↗

WE-A-12A-01: Medical Physics 1.0 to 2.0, Session 2: Radiography, Mammography and Fluoroscopy

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. Radiography 2.0: The development of electronic capture in recent years has changed the landscape and spurred reinvestment by healthcare providers. The radiography presentation will explore how the diagnostic medical physicist must adapt to these changes to support radiographic imaging, and how she/he can add value in radiography practice over the next 5-10 years. Topics of discussion include new metrology of evaluation, new models of clinical engagement, and effective integration of new technologies. Mammography 2.0: Mammography has been an interesting testing ground on the effectiveness of close involvement of medical physicists with equipment in the past twenty years. The outcomes have clearly shown major improvements in image quality and significant reduction in the average glandular dose. However, the medical physicist's role in mammography has been largely focused to annual surveys and with limited input on operational issues with image artifacts, optimal mammographic acquisition mode and problems with image quality. This mammography presentation will address why and how medical physicists must be prepared to address the new models of practice that include new metrics of performance and the integration of new technologies (DBT, syncretized mammograms, contrast mammography, breast CT) into clinical practice. Fluoroscopy 2.0: Physics support of fluoroscopy should be operationally as opposed to compliance focused. Testing protocols must address new hardware, acquisition methods, and image processing. Future available tools are discussed. Proper configuration of acquisition parameters (focal spot size, voltage and added filter, tube current, pulse width, pulse rate, scatter removal) as a function of patient size from the neonate to bariatric patient is key to providing diagnostic image quality at properly managed radiation doses. Learning Objectives: Appreciate the limitations of the currently available tools and techniques in clinical medical physics in radiography, mammography, and fluoroscopy, and ways to improve upon current deficiencies. Appreciate the changing environment of imaging practice and the need for the medical physicist to be an expert consultant and educator in a capacity that extends beyond the annual survey of equipment. Understand the status of the rapidly changing environment in breast imaging from planar imaging to tomosynthesis and possibly to breast CT. Identify appropriate configuration of acquisition parameters as a function of patient size to manage radiation dose and ensure diagnostic image quality.

60 APPLIED LIFE SCIENCES↗

Sub-Ångstrom electric field measurements on a universal detector in a scanning transmission electron microscope

Scanning transmission electron microscopy (STEM) excels in accessing atomic-scale structure and chemistry. Enhancing our ability to directly image the functionalities of local features in materials has become one of the most important topics in the future development of STEM. Recently, differential phase contrast (DPC) imaging has been utilized to map the internal electric and magnetic fields in materials from nanoscale features such as p–n junctions, skyrmions, and even from individual atoms. Here, we use an ultra-low noise SCMOS detector in as the diffraction plane camera to collect four-dimensional (4D) datasets. The high angular resolution, efficient high-SNR acquisition, and modifiability of the camera allow it to function as a universal detector, where STEM imaging configurations, such as DPC, bright field, annular bright field, and annular dark field can all be reconstructed from a single 4D dataset. By examining a distorted perovskite, DyScO3, which possesses projected lattice spacings as small as 0.83 Å, we demonstrate DPC spatial resolution almost reaching the information limit of a 100 keV electron beam. In addition, the perovskite has ordered O-coordinations with alternating octahedral tilts, which can be quantitatively measured with single degree accuracy by taking advantage of DPC’s sensitivity to light atoms. The results, acquired on a standard Ronchigram camera as opposed to a specialized DPC detector, open up new opportunities to understand and design functional materials and devices that involve lattice and charge coupling at nano- and atomic-scales.

47 OTHER INSTRUMENTATION↗

SOX1 links the function of neural patterning and Notch signalling in the ventral spinal cord during the neuron-glial fate switch

During neural development the transition from neurogenesis to gliogenesis, known as the neuron-glial ({Nu}/G) fate switch, requires the coordinated function of patterning factors, pro-glial factors and Notch signalling. How this process is coordinated in the embryonic spinal cord is poorly understood. Here, we demonstrate that during the N/G fate switch in the ventral spinal cord (vSC) SOX1 links the function of neural patterning and Notch signalling. We show that, SOX1 expression in the vSC is regulated by PAX6, NKX2.2 and Notch signalling in a domain-specific manner. We further show that SOX1 regulates the expression of Hes1 and that loss of Sox1 leads to enhanced production of oligodendrocyte precursors from the pMN. Finally, we show that Notch signalling functions upstream of SOX1 during this fate switch and is independently required for the acquisition of the glial fate perse by regulating Nuclear Factor I A expression in a PAX6/SOX1/HES1/HES5-independent manner. These data integrate functional roles of neural patterning factors, Notch signalling and SOX1 during gliogenesis.

60 APPLIED LIFE SCIENCES↗