At least 307 records · Page 17

Combined shipping protection and impingement detection wrap

A packaging material comprised of a gas-impermeable base layer, an indicator layer, and a gas-impermeable top layer is disclosed. The top layer is selected to rupture upon experiencing an impingement or impact that exceeds a predetermined threshold. The indicator layer is configured to change visual appearance upon exposure to ambient air. The top layer further may be configured into a plurality of cells, with each cell filled with a gas that is inert with respect to the indicator layer. The cells may be of a size and shape configured to indicate the location and shape of an impingement or impact, to alert a recipient of an item protected by the packaging material of an area that may require further inspection.

36 MATERIALS SCIENCE↗

Sorption-based atmospheric water harvesting device

A water-harvesting system can operate with a material that can take up and release water with minimum energy requirements and powered by low-grade energy sources, such as sunlight, in order to potentially allow its deployment into households, especially those located in sunny regions. A water-harvesting method and system can include vapor adsorption using a porous metal-organic framework. In certain embodiments, the porous metal-organic framework can include metal-organic framework in ambient air with low relative humidity, typical of the levels found in most dry regions of the world.

42 ENGINEERING↗

Sorption-based atmospheric water harvesting device

A water-harvesting system can operate with a material that can take up and release water with minimum energy requirements and powered by low-grade energy sources, such as sunlight, in order to potentially allow its deployment into households, especially those located in sunny regions. A water-harvesting method and system can include vapor adsorption using a porous metal-organic framework. In certain embodiments, the porous metal-organic framework can include metal-organic framework in ambient air with low relative humidity, typical of the levels found in most dry regions of the world.

42 ENGINEERING↗

Heat dissipation systems with hygroscopic working fluid

A heat dissipation system apparatus and method of operation using hygroscopic working fluid for use in a wide variety of environments for absorbed water in the hygroscopic working fluid to be released to minimize water consumption in the heat dissipation system apparatus for effective cooling in environments having little available water for use in cooling systems. The system comprises a low-volatility, hygroscopic working fluid to reject thermal energy directly to ambient air. The low-volatility and hygroscopic nature of the working fluid prevents complete evaporation of the fluid and a net consumption of water for cooling, and direct-contact heat exchange allows for the creation of large interfacial surface areas for effective heat transfer. Specific methods of operation prevent the crystallization of the desiccant from the hygrosopic working fluid under various environmental conditions.

42 ENGINEERING↗

Polyamine phosphorus dendrimer materials for carbon dioxide capture

The present disclosure provides novel solid sorbents synthesized by the reaction of polyamines with polyaldehyde phosphorous dendrimer (P-dendrimer) compounds. The sorbents are highly stable and exhibit rapid reaction kinetics with carbon dioxide, making the sorbents applicable for carbon capture, and can be easily regenerated for further use. The material is stable to aqueous and organic media, as well as strong acid and bases. The sorbent maintains full capacity over extended use. The material can be used for CO2 capture from pure CO2 streams, mixed gas streams, simulated flue gas, and ambient air. Additionally, the material can be adhered to surfaces for reversible CO2 capture applications outside of bulk particle-based processes.

Thompson, III, Samuel John↗

Liquid desiccant based dehumidification and cooling system

A liquid desiccant system including a high desorber, a low desorber, and an absorber that are in fluid communication with a working solution, where the high desorber provides rejected water vapor from the working fluid for condensation in a condenser of the low desorber that provides heat for rejection of additional water from the working solution in the low desorber effectively multiplying the heat provided for desorption. The low desorber provided the concentrated working solution to the absorber where water from ambient air is condensed into the concentrated working solution to provide a dilute working solution within a working solution conduit of the absorber that is thermally coupled to an internal cooler of the absorber. In some embodiments, the working solution can be an aqueous solution of at least one ionic liquid.

Moghaddam, Saeed↗

Liquid desiccant based dehumidification and cooling system

A liquid desiccant system including a high desorber, a low desorber, and an absorber that are in fluid communication with a working solution, where the high desorber provides rejected water vapor from the working fluid for condensation in a condenser of the low desorber that provides heat for rejection of additional water from the working solution in the low desorber effectively multiplying the heat provided for desorption. The low desorber provided the concentrated working solution to the absorber where water from ambient air is condensed into the concentrated working solution to provide a dilute working solution within a working solution conduit of the absorber that is thermally coupled to an internal cooler of the absorber. In some embodiments, the working solution can be an aqueous solution of at least one ionic liquid.

Moghaddam, Saeed↗

Towards a Benchmark Experiment with the Compact Nuclear Power Source

The Compact Nuclear Power Source (CNPS) was a high-assay low enriched uranium (HALEU) tristructural isotropic (TRISO)-fueled, graphite-moderated microreactor constructed in 1987 at Los Alamos National Laboratory. The reactor, conceived as a power source for short-range radar stations, was designed to be "walk-away safe," and was cooled by heat pipes and ambient air. Though the project was formally cancelled after the fuel and moderator material had been received, its potential to meaningfully advance the body of critical and integral data was evident, and critical experiments with a mock-up of the reactor proceeded at TA-18 until its disassembly in 1991. The reflector and some components of the core would later go on to see service as part of the New Production Reactor Modular High-Temperature Gas-Cooled Reactor (NP-MHTGR) critical experiments. In light of the progress made by groups like Westinghouse and X-Energy towards contemporary graphite-moderated microreactors, the system remains an attractive candidate for the basis of a benchmark experiment even today. Uncertainties remain, however, in some features of the system–inconsistencies in the dimensions and composition of the reactor’s components as described in literature and implemented in current computational models. The identification, quantification, and to the extent possible, the minimization of these uncertainties is a crucial task on the path towards creating a benchmark based on the CNPS system. The present work seeks to initiate this process with a survey of available documentation and improvements to the accuracy of CNPS neutronics models.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal storage system with coupled tanks

Methods and apparatus are disclosed for high-efficiency thermal storage with a fluid-filled “battery” tank positioned within a fluid-filled “reservoir” tank. Fluid loops couple the tanks to a heat pump and a building. The heat pump can charge the battery tank or deliver thermal energy (cold or heat) to a building, using the reservoir tank or ambient air as a thermal energy source. The battery tank can discharge energy to the building jointly with the heat pump or, at periods of peak electricity usage, with the heat pump switched off. Operating modes allow significant savings in electricity usage and mitigate the “duck curve.” Low duty cycle usage of the reservoir enables efficient underground thermal storage with less digging than conventional geothermal technologies. Additional efficiency is achieved with phase change materials installed inside a tank or in a tank wall, providing temperature regulation. Control methods are disclosed.

15 GEOTHERMAL ENERGY↗

Heat dissipation systems with hygroscopic working fluid

A heat dissipation system apparatus and method of operation using hygroscopic working fluid for use in a wide variety of environments for absorbed water in the hygroscopic working fluid to be released to minimize water consumption in the heat dissipation system apparatus for effective cooling in environments having little available water for use in cooling systems. The system comprises a low-volatility, hygroscopic working fluid to reject thermal energy directly to ambient air. The low-volatility and hygroscopic nature of the working fluid prevents complete evaporation of the fluid and a net consumption of water for cooling, and direct-contact heat exchange allows for the creation of large interfacial surface areas for effective heat transfer. Specific methods of operation prevent the crystallization of the desiccant from the hygrosopic working fluid under various environmental conditions.

Martin, Christopher L.↗

High Temperature Ternary Chloride Molten Salt Pump

This work investigates the design criteria considering thermal, structural, and material selection of a ternary chloride (MgCl2-NaCl-KCl) molten salt pump that is capable of running at temperatures above 720 °C. In this work, preliminary testing of salt-wetted hydrodynamic bearings was done to investigate different material pairings including Colmonoy grades, Stellite grades, and a novel Nickel Tungsten Carbide alloy (HybrimetTM NiWC3b) used as a High Velocity Oxygen Fuel (HVOF) coating. The coating has shown to withstand the corrosive nature of the molten salt. The pump wetted components are made of Inconel 625 and features a carbon ring seal (CIRPAC Seal) flooded with a N2 gas flow on the overhead to keep salt vapors from interacting with the external ambient air. A comprehensive pump test program has been completed. Over 90 hours run time pumping hot chloride salts at temperatures up to 720 °C in which enough data was captured to produce performance curves at 3 different operating speeds. This research showcases a promising design for use in the Concentrated Solar Power (CSP) Gen 3 liquid-pathway and sets the ground for further development and use of the HybrimetTM NiWC3b as a competitive alternative to available superalloys.

14 SOLAR ENERGY↗

High Temperature Ternary Chloride Molten Salt Pump

This work investigates the design criteria considering thermal, structural, and mate-rial selection of a ternary chloride (MgCl2-NaCl-KCl) molten salt pump that is capable of running at temperatures above 720 °C. In this work, preliminary testing of salt-wetted hydrodynamic bearings was done to investigate different material pairings including colmonoy grades, stellite grades, and a novel NiWC-based alloy (i.e. HybrimetTM NiWC3b) used as a High Velocity Ox-ygen Fuel (HVOF) coating. The coating has shown to withstand the corrosive nature of the salt, and is additionally used to protect a 316L stainless steel pump reservoir. The pump wetted components are made of Inconel 625, and it features a carbon ring seal developed by Flows-erve flooded with a N2 gas flow on the overhead to keep salt vapors from interacting with the external ambient air. This research showcases a promising design for use in the CSP Gen 3 liquid-pathway and sets the ground for further development and use of the HybrimetTM NiWC3b as a competitive alternative to available superalloys. Further work will further characterize the pump by performance & cycle testing in molten salt at higher temperatures.

14 SOLAR ENERGY↗

Hydrogen Detection Strategies to Support H2@SCALE - The NREL Sensor Laboratory

Hydrogen represents a major pathway to decarbonize and stabilize the national and international energy industry and select manufacturing markets. To facilitate the development of hydrogen markets, the US Department of Energy initiated H2@Scale to bring together stakeholders to advance affordable hydrogen production, transport, storage, and utilization to increase revenue opportunities in multiple energy sectors. One major impediment to hydrogen implementation is cost. To expedite the use of hydrogen in energy and other markets, the United States announced in 2021 the Hydrogen Shot, which seeks to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). As the cost of hydrogen drops, new applications will emerge that will require unique configurations of existing equipment and infrastructure, and eventually lead to advances in the generation and utilization of hydrogen. As the hydrogen economy expands, sensors and detection methods will need to adapt to changing infrastructure demands to address the primary targets of health & safety, emissions monitoring, and process control. The NREL Sensor Laboratory is playing a pivotal role in advancing the use of hydrogen sensors and detection methodologies in each of these categories to support DOE's mission for safe and efficient utilization in emerging markets. Health & safety monitors are required to ensure that operators and facilities can react to unintended hydrogen releases, either as GH2, LH2, or as a constituent of blends (e.g., natural gas or ammonia). Current detection methodologies focus on safety applications to detect near its lower flammable limit (4 vol %), and typically include point sensors in applications such as fixed or mobile detectors (e.g., personal gas monitors). Methodologies amenable for area detection include acoustic, emerging optical imaging methods, and flame detectors. Comparable detection strategies can be utilized for emissions monitoring and quantization, however few methods can simultaneously cover both low (emissions) and high (health & safety) levels. Deployment of emission level detectors will be required to 1) reduce product loss through small but potentially significant leaks from an environmental or cost perspective, 2) reduce downtime of high demand systems by early identification of eminent system failures (leaks through pump or compressor seals indicative of impending failure), and 3) address potential emission monitoring requirements that may be set by regulating bodies. The first two points should be adopted by industry to reduce the cost-of-goods-sold. The third main category for hydrogen detection relates to process control and may be advantageous for many existing applications. Two main applications are emerging. For example, the purity requirements for hydrogen that is dispensed from refueling systems for hydrogen fuel cell electric vehicles (FCEV) is rigorously regulated by the Standard SAE J2719, which prescribes maximum allowable levels of multiple impurities in the hydrogen fuel and must be verified by a regulatory body. Hydrogen contaminant detectors (HCD) integrated to the fueling station can assure this compliance. HCDs must be able operate in 100% H2 backgrounds and be able to distinguish between multiple contaminants at low ppm to low ppb levels. Secondly, as a strategy to decarbonize the natural gas grid, there are proposals to blend hydrogen with natural gas. This blending will affect transport applications (pipeline infrastructure), stationary combustion systems (turbines), and consumer and commercial appliances. In the short-term, hydrogen levels up to 20% are proposed. Variations in the hydrogen level can have dramatic impact on the combustion process and on the potential response of safety sensors. These mixtures may be regulated so that the concentration at a delivery point must be monitored with high precision. However, routine maintenance may introduce background gases such as ambient air (with water) or maintenance gases (introduced with welding processes or adhesive outgassing.) Therefore, the detection methodology must be robust enough to recover or respond to various contaminants. Several reviews can be found in literature addressing sensing and detection technologies, including their limitations and applications. However, for most applications, limitations can be alleviated by combining various detection techniques either through system integration or implementation of machine learning methods (artificial intelligence). In this presentation, we will discuss several applications, highlight their current approach for hydrogen detection, and suggest detection strategies to supplement their limitations.

ENERGY STORAGE,HYDROGEN↗

The relative importance of building design parameters in reducing energy use and sensible heat release from buildings in light of forecasted future weather data and building coverage ratio

Buildings typically have a 60-to-75-year lifespan before they require significant maintenance or modifications. However, most builders evaluate the performance of their new buildings using whole-building energy simulation tools based on the current typical meteorological year (TMY) file or actual meteorological year. The energy use consumption and sensible heat release pattern observed from buildings could potentially change based on shifting global climates. Therefore, the recommended energy-efficiency design parameters might also change during these periods. In this study, we evaluate the role of different building design parameters, such as material reflectivity, HVAC COP, and insulation values, on building energy usage and sensible heat release from buildings with different building coverage ratios (BCR), based on the current and future weather file TMY (fTMY) for the middle of the century (2040–2060). The role of sensible heat release from buildings is not accounted for accurately while estimating building energy usage in most whole-building energy simulations. The study conducts a series of whole-building energy simulation analyses using EnergyPlus to evaluate the role of different design parameters based on TMY and fTMY weather conditions. The analysis is conducted for two hot desert climatic cities: Phoenix (USA) and Abu Dhabi (UAE). The results show that, for the base case in a future climate, the sensible heat release is reduced by an average of 30% due to the reduced delta T between the surface and ambient air. Further, the results show an increase in total energy consumption by 5% annually. The results also show that, for buildings with traditional coatings, shorter buildings release more heat than taller buildings. On the other hand, for buildings with reflective paints, shorter buildings release less heat than taller buildings. The findings from this study can be used by policymakers, utility companies, and builders to better understand the relative role of different building design parameters while constructing new and retrofitting existing buildings.

Alhazmi, Mansour [King Fahd University of Petroleu↗

Influence of pilot-fuel mixing on the spatio-temporal progression of two-stage autoignition of diesel-sprays in low-reactivity ambient fuel-air mixture

The spatial and temporal locations of autoignition for direct-injection compression-ignition engines depend on fuel chemistry, temperature, pressure, and mixing trajectories in the fuel jets. Dual-fuel systems can provide insight into both fuel-chemistry and physical effects by varying fuel reactivities and engine operating conditions. In this context, the spatial and temporal progression of two-stage autoignition of a diesel-fuel surrogate, n-heptane, in a lean-premixed charge of synthetic natural-gas (NG) and air is imaged in an optically accessible heavy-duty diesel engine. The lean-premixed charge of NG is prepared by fumigation upstream of the engine intake manifold. Optical diagnostics include high-speed (15kfps) cool-flame chemiluminescence-imaging as an indicator of low-temperature heat-release (LTHR) and OH* chemiluminescence-imaging as an indicator high-temperature heat-release (HTHR). NG prolongs the ignition delay of the pilot fuel and increases the combustion duration. Zero-dimensional chemical-kinetics simulations provide further understanding by replicating a Lagrangian perspective for mixtures evolving along streamlines originating either at the fuel nozzle or in the ambient gas, for which the pilot-fuel concentration is either decreasing or increasing, respectively. The zero-dimensional simulations predict that LTHR initiates most likely on the air streamlines before transitioning to HTHR, either on fuel-streamlines or on air-streamlines in regions of near-constant φ. Due to the relatively short pilot-fuel injection-durations, the transient increase in entrainment near the end of injection (entrainment wave) is important for quickly creating auto-ignitable mixtures. To achieve desired combustion characteristics, e.g., multiple ignition-kernels and favorable combustion phasing and location (e.g., for reducing wall heat-transfer or optimizing charge stratification), adjusting injection parameters could tailor mixing trajectories to offset changes in fuel ignition chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photo-DAC: Light-Driven Ambient-Temperature Direct Air Capture by a Photobase

Direct air capture (DAC) may reduce atmospheric CO 2 concentrations to preindustrial levels, yet the high energies and temperatures involved in current DAC technologies hinder large-scale deployment. In the case of aqueous-based CO 2 absorbents, a large energetic penalty is associated with heating and boiling off water, as required for thermally driven solvent regeneration. This could be avoided via photochemically driven pH swings involving photoacids or photobases, and harnessing abundant and renewable solar energy, though efficient solvent regeneration and recycling in a realistic multicycle DAC process remains challenging. Herein, we report a photochemically driven DAC process (photo-DAC) in which atmospheric CO 2 capture by an aqueous glycylglycine (GlyGly) solution is enabled through a pH swing by a pyridine-substituted diiminoguanidine (PyDIG) photobase. Upon irradiation with UV light, the PyDIG photobase undergoes photoisomerization from the E,E to the Z,Z isomer, corresponding to a pK a increase of 2.8 units that activates GlyGly for DAC through deprotonation. After the GlyGly/PyDIG solvent is saturated with atmospheric carbon dioxide, leaving it in the dark under ambient conditions leads to the isomerization of PyDIG from the Z,Z back to the E,E isomer, which is accompanied by a pH drop and CO 2 release. To demonstrate the recyclability of the GlyGly/PyDIG solvent, we have completed six consecutive DAC cycles, with a measured average cyclic capacity in the range of 0.21–0.26 mol CO 2 per mol of GlyGly/PyDIG. These results open the prospect for energy-efficient DAC cycles completed entirely at ambient conditions, thereby avoiding the significant energy penalties associated with heating and boiling aqueous solvents.

Einkauf, Jeffrey D. [Oak Ridge National Laboratory↗

West Valley Demonstration Project Annual Site Environmental Report (CY2019)

The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2019. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2019 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗