Search NASA⌕ Search

SEARCH · Search NASA

Results for “analytical development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Failure Probability Constrained AC Optimal Power Flow

Despite cascading failures being the central cause of blackouts in power transmission systems, existing operational and planning decisions are made largely by ignoring their underlying cascade potential. This paper posits a reliability-aware AC Optimal Power Flow formulation that seeks to design a dispatch point which has a low operator-specified likelihood of triggering a cascade starting from any single component outage. By exploiting a recently developed analytical model of the probability of component failure, our Failure Probability-constrained ACOPF (FP-ACOPF) utilizes the system's expected first failure time as a smoothly tunable and interpretable signature of cascade risk. Here, we use techniques from bilevel optimization and numerical linear algebra to efficiently formulate and solve the FP-ACOPF using off-the-shelf solvers. Extensive simulations on the IEEE 118-bus case show that, when compared to the unconstrained and N-1 security-constrained ACOPF, our probability-constrained dispatch points can significantly lower the probabilities of long severe cascades and of large demand losses, while incurring only minor increases in total generation costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A comparative analysis of OTF, NPS, and DQE in energy integrating and photon counting digital x-ray detectors

Purpose: One of the benefits of photon counting (PC) detectors over energy integrating (EI) detectors is the absence of many additive noise sources, such as electronic noise and secondary quantum noise. The purpose of this work is to demonstrate that thresholding voltage gains to detect individual x rays actually generates an unexpected source of white noise in photon counters. Methods: To distinguish the two detector types, their point spread function (PSF) is interpreted differently. The PSF of the energy integrating detector is treated as a weighting function for counting x rays, while the PSF of the photon counting detector is interpreted as a probability. Although this model ignores some subtleties of real imaging systems, such as scatter and the energy-dependent amplification of secondary quanta in indirect-converting detectors, it is useful for demonstrating fundamental differences between the two detector types. From first principles, the optical transfer function (OTF) is calculated as the continuous Fourier transform of the PSF, the noise power spectra (NPS) is determined by the discrete space Fourier transform (DSFT) of the autocovariance of signal intensity, and the detective quantum efficiency (DQE) is found from combined knowledge of the OTF and NPS. To illustrate the calculation of the transfer functions, the PSF is modeled as the convolution of a Gaussian with the product of rect functions. The Gaussian reflects the blurring of the x-ray converter, while the rect functions model the sampling of the detector. Results: The transfer functions are first calculated assuming outside noise sources such as electronic noise and secondary quantum noise are negligible. It is demonstrated that while OTF is the same for two detector types possessing an equivalent PSF, a frequency-independent (i.e., ''white'') difference in their NPS exists such that NPS{sub PC}{>=}NPS{sub EI} and hence DQE{sub PC}{<=}DQE{sub EI}. The necessary and sufficient condition for equality is that the PSF is a binary function given as zero or unity everywhere. In analyzing the model detector with Gaussian blurring, the difference in NPS and DQE between the two detector types is found to increase with the blurring of the x-ray converter. Ultimately, the expression for the additive white noise of the photon counter is compared against the expression for electronic noise and secondary quantum noise in an energy integrator. Thus, a method is provided to determine the average secondary quanta that the energy integrator must produce for each x ray to have superior DQE to a photon counter with the same PSF. Conclusions: This article develops analytical models of OTF, NPS, and DQE for energy integrating and photon counting digital x-ray detectors. While many subtleties of real imaging systems have not been modeled, this work is illustrative in demonstrating an additive source of white noise in photon counting detectors which has not yet been described in the literature. One benefit of this analysis is a framework for determining the average secondary quanta that an energy integrating detector must produce for each x ray to have superior DQE to competing photon counting technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automating linear accelerator quality assurance

Purpose: The purpose of this study was 2-fold. One purpose was to develop an automated, streamlined quality assurance (QA) program for use by multiple centers. The second purpose was to evaluate machine performance over time for multiple centers using linear accelerator (Linac) log files and electronic portal images. The authors sought to evaluate variations in Linac performance to establish as a reference for other centers. Methods: The authors developed analytical software tools for a QA program using both log files and electronic portal imaging device (EPID) measurements. The first tool is a general analysis tool which can read and visually represent data in the log file. This tool, which can be used to automatically analyze patient treatment or QA log files, examines the files for Linac deviations which exceed thresholds. The second set of tools consists of a test suite of QA fields, a standard phantom, and software to collect information from the log files on deviations from the expected values. The test suite was designed to focus on the mechanical tests of the Linac to include jaw, MLC, and collimator positions during static, IMRT, and volumetric modulated arc therapy delivery. A consortium of eight institutions delivered the test suite at monthly or weekly intervals on each Linac using a standard phantom. The behavior of various components was analyzed for eight TrueBeam Linacs. Results: For the EPID and trajectory log file analysis, all observed deviations which exceeded established thresholds for Linac behavior resulted in a beam hold off. In the absence of an interlock-triggering event, the maximum observed log file deviations between the expected and actual component positions (such as MLC leaves) varied from less than 1% to 26% of published tolerance thresholds. The maximum and standard deviations of the variations due to gantry sag, collimator angle, jaw position, and MLC positions are presented. Gantry sag among Linacs was 0.336 ± 0.072 mm. The standard deviation in MLC position, as determined by EPID measurements, across the consortium was 0.33 mm for IMRT fields. With respect to the log files, the deviations between expected and actual positions for parameters were small (<0.12 mm) for all Linacs. Considering both log files and EPID measurements, all parameters were well within published tolerance values. Variations in collimator angle, MLC position, and gantry sag were also evaluated for all Linacs. Conclusions: The performance of the TrueBeam Linac model was shown to be consistent based on automated analysis of trajectory log files and EPID images acquired during delivery of a standardized test suite. The results can be compared directly to tolerance thresholds. In addition, sharing of results from standard tests across institutions can facilitate the identification of QA process and Linac changes. These reference values are presented along with the standard deviation for common tests so that the test suite can be used by other centers to evaluate their Linac performance against those in this consortium.

60 APPLIED LIFE SCIENCES↗

Models Derived from In Vitro Analyses of Spleen, Liver, and Lung Leukocyte Functions Predict Vaccine Efficacy against the Francisella tularensis Live Vaccine Strain (LVS)

Currently, there are no licensed vaccines and no correlates of protection against Francisella tularensis, which causes tularemia. We recently demonstrated that measuring in vitro control of intramacrophage bacterial growth by murine F. tularensis-immune splenocytes, as well as transcriptional analyses, discriminated Francisella vaccines of different efficacies. Further, we identified potential correlates of protection against systemic challenge. Here, we extended this approach by studying leukocytes derived from lungs and livers of mice immunized by parenteral and respiratory routes with F. tularensis vaccines. Liver and lung leukocytes derived from intradermally and intranasally vaccinated mice controlled in vitro Francisella Live Vaccine Strain (LVS) intramacrophage replication in patterns similar to those of splenocytes. Gene expression analyses of potential correlates also revealed similar patterns in liver cells and splenocytes. In some cases (e.g., tumor necrosis factor alpha [TNF-α], interleukin 22 [IL-22], and granulocyte-macrophage colony-stimulating factor [GM-CSF]), liver cells exhibited even higher relative gene expression, whereas fewer genes exhibited differential expression in lung cells. In contrast with their strong ability to control LVS replication, splenocytes from intranasally vaccinated mice expressed few genes with a hierarchy of expression similar to that of splenocytes from intradermally vaccinated mice. Thus, the relative levels of gene expression vary between cell types from different organs and by vaccination route. Most importantly, because studies comparing cell sources and routes of vaccination supported the predictive validity of this coculture and gene quantification approach, we combined in vitro LVS replication with gene expression data to develop analytical models that discriminated between vaccine groups and successfully predicted the degree of vaccine efficacy. Thus, this strategy remains a promising means of identifying and quantifying correlative T cell responses.

59 BASIC BIOLOGICAL SCIENCES↗

The multiple quantum NMR dynamics in systems of equivalent spins with a dipolar ordered initial state

The multiple quantum (MQ) NMR dynamics in the system of equivalent spins with the dipolar ordered initial state is considered. The high symmetry of the Hamiltonian responsible for the MQ NMR dynamics (the MQ Hamiltonian) is used to develop analytic and numerical methods for the investigation of the MQ NMR dynamics in systems consisting of hundreds of spins from the 'first principles.' We obtain the dependence of the intensities of the MQ NMR coherences on their orders (profiles of the MQ NMR coherences) for systems of 200-600 spins. It is shown that these profiles may be well approximated by exponential distribution functions. We also compare the MQ NMR dynamics in the systems of equivalent spins having two different initial states, the dipolar ordered state and the thermal equilibrium state in a strong external magnetic field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum theory of stimulated Cherenkov emission and stimulated compton scattering of electromagnetic waves by a low-density relativistic electron beam

A quantum theory of instabilities of a relativistic electron beam due to the stimulated Cherenkov effect in a dielectric and the stimulated Compton effect in vacuum is presented. The instability growth rates are found in a linear approximation and are shown to go over to the familiar growth rates in the classical approximation. A nonlinear theory of instabilities in the quantum case is developed. Analytic solutions are obtained that describe the nonlinear saturation of the amplitudes of the electromagnetic waves emitted by the beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of the rotational stabilization of tokamak plasmas with account of skin effect in the resistive wall

The influence of the Resistive Wall Mode (RWM) rotation on its stability in tokamaks is analyzed. Recently developed analytical theory [V. D. Pustovitov, Phys. Plasmas 19, 062503 (2012)] predicts that, when the skin depth s becomes much smaller than the wall thickness d{sub w}, the resistive dissipation in the wall in combination with the mode rotation stabilizes the mode up to complete suppression of instability. Here this effect is studied without the restriction on the ratio s/d{sub w}. Thereby the applicability of analytical predictions and accuracy of asymptotic expressions relating the growth rate to the rotation frequency of RWM is clarified. The dispersion relation for the rotating modes is derived in the single-mode cylindrical approximation and solved numerically. It is shown that the rotational stabilization of the plasma, the same as found earlier, is possible even at s/d{sub w} of the order unity if the mode rotation frequency is above a critical level. The dependences of the growth rate on the mode frequency are calculated for different plasma parameters. It is shown that, at a given plasma state with a linear response to external perturbations, the growth rate of the mode is maximal at the mode locking (when the rotation is lost). The relation of the mode minimal rotation frequency at the stability boundary with the growth rate at the mode locking is found. The analysis demonstrates strong influence of dissipation in the wall on the dynamics of rotating and locked RWMs and confirms the necessity to incorporate the skin effect into their description. The obtained estimates allow one to compare these predictions with experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasmachemical and heterogeneous processes in ozonizers with oxygen activation by a dielectric barrier discharge

Plasmachemical and heterogeneous processes of generation and loss of ozone in the atmosphericpressure dielectric barrier discharge in oxygen are studied theoretically. Plasmachemical and electronic kinetics in the stage of development and decay of a single plasma filament (microdischarge) are calculated numerically with and without allowance for the effects of ozone vibrational excitation and high initial ozone concentration. The developed analytical approach is applied to determine the output ozone concentration taking into account ozone heterogeneous losses on the Al{sub 2}O{sub 3} dielectric surface. Using the results of quantummechanical calculations by the method of density functional theory, a multistage catalytic mechanism of heterogeneous ozone loss based on the initial passivation of a pure Al{sub 2}O{sub 3} surface by ozone and the subsequent interaction of O{sub 3} molecules with the passivated surface is proposed. It is shown that the conversion reaction 2O{sub 3} → 3O{sub 2} of a gas-phase ozone molecule with a physically adsorbed ozone molecule can result in the saturation of the maximum achievable ozone concentration at high specific energy depositions, the nonstationarity of the output ozone concentration, and its dependence on the prehistory of ozonizer operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On Compatible Transfer Operators in Nonsymmetric Algebraic Multigrid

The standard goal for an effective algebraic multigrid (AMG) algorithm is to develop relaxation and coarse-grid correction schemes that attenuate complementary error modes. In the nonsymmetric setting, coarse-grid correction &#x3A0; will almost certainly be nonorthogonal (and divergent) in any known standard product, meaning ∥&#x3A0;∥ > 1. This introduces a new consideration, that one wants coarse-grid correction to be as close to orthogonal as possible, in an appropriate norm. In addition, due to nonorthogonality, &#x3A0; may actually amplify certain error modes that are in the range of interpolation. Relaxation must then not only be complementary to interpolation, but also rapidly eliminate any error amplified by the nonorthogonal correction, or the algorithm may diverge. Here this paper develops analytic formulae on how to construct “compatible” transfer operators in nonsymmetric AMG such that ∥&#x3A0;∥ = 1 in some standard matrix-induced norm. Discussion is provided on different options for the norm in the nonsymmetric setting, the relation between “ideal” transfer operators in different norms, and insight into the convergence of nonsymmetric reduction-based AMG.

97 MATHEMATICS AND COMPUTING↗

Robust Optimal Experimental Design of Infinite-Dimensional Bayesian Nonlinear Inverse Problems

Abstract. We consider robust optimal experimental design (ROED) for nonlinear Bayesian inverse problems governed by partial differential equations (PDEs). An optimal design is one that maximizes some utility quantifying the quality of the solution of an inverse problem. However, the optimal design is dependent on elements of the inverse problem such as the simulation model, the prior, or the measurement error model. ROED aims to produce an optimal design that is aware of the additional uncertainties encoded in the inverse problem and remains optimal even after variations in them. We follow a worst-case scenario approach to develop a new framework for robust optimal design of nonlinear Bayesian inverse problems. The proposed framework (a) is scalable and designed for infinite-dimensional Bayesian nonlinear inverse problems constrained by PDEs; (b) develops efficient approximations of the utility, namely the expected information gain; (c) employs eigenvalue sensitivity techniques to develop analytical forms and efficient evaluation methods of the gradient of the utility with respect to the uncertainties against which we wish to be robust; and (d) employs a probabilistic optimization paradigm that properly defines and efficiently solves the resulting combinatorial max-min optimization problem. The effectiveness of the proposed approach is illustrated for optimal sensor placement problem in an inverse problem governed by an elliptic PDE.

Chowdhary, Abhijit↗

The Hybrid Toolkit

The Hybrid Toolkit facilitates moving research algorithms into a production environment by creating useful abstractions that separate analytics developers from the intricacies of the production data formats, data flows, and result representations. The toolkit also assists developers with activities such as creating analysis feature vectors, converting between data structures, and creating data pipelines.

Davis IV, WarrenL↗

Analyses by the Defense Waste Processing Facility Laboratory of Thorium Glasses from the Sludge Batch 6 Variability Study

The Savannah River Remediation (SRR) Defense Waste Processing Facility (DWPF) is currently processing Sludge Batch 6 (SB6) with Frit 418. At times during the processing of this glass system, thorium is expected to be at concentrations in the final wasteform that make it a reportable element for the first time since startup of radioactive operations at the DWPF. The Savannah River National Laboratory (SRNL) supported the qualification of the processing of this glass system at the DWPF. A recommendation from the SRNL studies was the need for the DWPF Laboratory to establish a method to measure thorium by Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICPAES). This recommendation led to the set of thorium-bearing glasses from the SB6 Variability Study (VS) being submitted to the DWPF Laboratory for chemical composition measurement. The measurements were conducted by the DWPF Laboratory using the sodium peroxide fusion preparation method routinely employed for analysis of samples from the Slurry Mix Evaporator (SME). These measurements are presented and reviewed in this report. The review indicates that the measurements provided by the DWPF Laboratory are comparable to those provided by Analytical Development's laboratory at SRNL for these same glasses. As a result, the authors of this report recommend that the DWPF Laboratory begin using its routine peroxide fusion dissolution method for the measurement of thorium in SME samples of SB6. The purpose of this technical report is to present the measurements generated by the DWPF Laboratory for the SB6 VS glasses and to compare the measurements to the targeted compositions for these VS glasses as well as to SRNL's measurements (both sets, targeted and measured, of compositional values were reported by SRNL in [2]). The goal of these comparisons is to provide information that will lead to the qualification of peroxide fusion dissolution as a method for the measurement by the DWPF Laboratory of thorium in SME glass samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TRIPLICATE SODIUM IODIDE GAMMA RAY MONITORS FOR THE SMALL COLUMN ION EXCHANGE PROGRAM

This technical report contains recommendations from the Analytical Development (AD) organization of the Savannah River National Laboratory (SRNL) for a system of triplicate Sodium Iodide (NaI) detectors to be used to monitor Cesium-137 ({sup 137}Cs) content of the Decontaminated Salt Solution (DSS) output of the Small Column Ion Exchange (SCIX) process. These detectors need to be gain stabilized with respect to temperature shifts since they will be installed on top of Tank 41 at the Savannah River Site (SRS). This will be accomplished using NaI crystals doped with the alpha-emitting isotope, Americium-241({sup 241}Am). Two energy regions of the detector output will be monitored using single-channel analyzers (SCAs), the {sup 137}Cs full-energy {gamma}-ray peak and the {sup 241}Am alpha peak. The count rate in the gamma peak region will be proportional to the {sup 137}Cs content in the DSS output. The constant rate of alpha decay in the NaI crystal will be monitored and used as feedback to adjust the high voltage supply to the detector in response to temperature variation. An analysis of theoretical {sup 137}Cs breakthrough curves was used to estimate the gamma activity expected in the DSS output during a single iteration of the process. Count rates arising from the DSS and background sources were predicted using Microshield modeling software. The current plan for shielding the detectors within an enclosure with four-inch thick steel walls should allow the detectors to operate with the sensitivity required to perform these measurements. Calibration, testing, and maintenance requirements for the detector system are outlined as well. The purpose of SCIX is to remove and concentrate high-level radioisotopes from SRS salt waste resulting in two waste streams. The concentrated high-level waste containing {sup 137}Cs will be sent to the Defense Waste Processing Facility (DWPF) for vitrification and the low-level DSS will be sent to the Saltstone Production Facility (SPF) to be incorporated into grout.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploratory Research: Mercury Stable Isotopes as Indicators of the Biogeochemical Cycling of Mercury (Final Project Report)

This exploratory project investigated the use of mercury (Hg) stable isotope measurements as a new approach to study how Hg moves and changes its chemical form in environmental systems, with particular focus on the East Fork of Poplar Creek (EFPC) near the DOE Y-12 plant (a Hg contamination source). This study developed analytical methods and collected pilot data that have set the stage for more detailed studies and have begun to provide insights into Hg movement and chemical changes. The overall Hg stable isotope approach was effective. The Hg isotope analysis methods yielded high-precision measurements of the sediment, water, and fish samples analyzed; quality control measures demonstrated the precision. The pilot data show that the 202 Hg/ 198 Hg, 199 Hg/ 198 Hg, and 201 Hg/ 198 Hg isotope ratios vary in this system. 202 Hg/ 198 Hg ratios of the Hg released from the Y-12 plant are relatively high, and those of the regional Hg background in soils and river sediments are significantly lower. Unfortunately, 202 Hg/ 198 Hg differences that might have been useful to distinguish early Hg releases from later releases were not observed. However, 202 Hg/ 198 Hg ratios in sediments do provide insights into chemical transformations that may occur as Hg moves through the system. Furthermore, 199 Hg/ 198 Hg and 201 Hg/ 198 Hg ratio analyses of fish tissues indicate that the effects of sunlight-driven chemical reactions on the Hg that eventually ends up in EFPC fish are measurable, but small. These results provide a starting point for a more detailed study (already begun at Univ. of Michigan) that will continue Hg isotope ratio work aimed at improving understanding of how Hg moves, changes chemically, and does or does not take on more highly toxic forms in the Oak Ridge area. This work also benefits efforts to trace Hg contamination in the Clinch and Tennessee Rivers, into which EFPC flows, and to distinguish Hg from the Y-12 plant from that released from a nearby coal ash accident.

54 ENVIRONMENTAL SCIENCES↗

Preparation and Initial Characterization of Fluidized Bed Steam Reforming Pure-Phase Standards

Hanford is investigating the Fluidized Bed Steam Reforming (FBSR) process for their Low Activity Waste. The FBSR process offers a low-temperature continuous method by which liquid waste can be processed with the addition of clay into a sodium aluminosilicate (NAS) waste form. The NAS waste form is mainly comprised of nepheline (NaAlSiO 4 ), sodalite (Na 8 [AlSiO 4 ] 6 Cl 2 ), and nosean (Na 8 [AlSiO 4 ] 6 SO 4 ). Anions such as perrhenate (ReO 4 - ), pertechnetate (TcO 4 - ), and iodine (I - ) are expected to replace sulfate in the nosean structure and/or chloride in the sodalite mineral structure (atomically bonded inside the aluminosilicate cages that these mineral structures possess). In the FBSR waste form, each of these phases can exist in a variety of solid solutions that differ from the idealized forms observed in single crystals in nature. The lack of understanding of the durability of these stoichiometric or idealized mineral phases complicates the ability to deconvolute the durability of the mixed phase FBSR product since it is a combination of different NAS phases. To better understand the behavior, fabrication and testing of the individual phases of the FBSR product is required. Analytical Development (AD) of the Science and Technology directorate of the Savannah River National Laboratory (SRNL) was requested to prepare the series of phase-pure standards, consisting of nepheline, nosean, and Cl, Re, and I sodalite. Once prepared, X-ray Diffraction (XRD) analyses were used to confirm the products were phase pure. These standards are being used for subsequent characterization studies consisting of the following: single-pass flow-through (SPFT) testing, development of thermodynamic data, and x-ray diffraction (XRD) calibration curves. In addition to the above mentioned phase-pure standards, AD was tasked with fabricating a mixed Tc-Re sodalite.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improved Production and Separation Technologies for Non-standard PET Radionuclides

Brief summary of activity issues, concerns, successes: Project 1 is completed. We have optimized plating parameters with the new target bodies and slanted target plating system. The target station has been mounted on the end of the beamline, service lines have been Installed to allow for helium and water cooling. We have routinely produced copper-64 using the new slanted target system in conjunction with our automated system. In project 2, we successfully fabricated and tested microfluidic extraction devices made out of two organic solvent-resistant polymers, thiolene and SIFEL. Initially, we developed analytical and computational models to describe the extraction process, and used the model to design the microfluidic devices. Then we optimized the microfabrication procedures to manufacture microreactors, followed by optimization of the operational parameters to obtain a stable aqueous-organic interface, which is critical for efficient extraction. When we tested the thiolene devices for extraction of copper-64, we observed very low extraction efficiencies (less than 5%) due to adhesion of copper to thiolene. However, we observed very high extraction efficiencies with SIFEL devices (greater than 95%), which are due to the high interfacial area for extraction and shorter diffusion lengths.

07 ISOTOPE AND RADIATION SOURCES↗

Investigation into the Rate of Trioctylamine Partitioning into the MCU Aqueous Phases

The Savannah River National Laboratory (SRNL) has examined the issue of trioctylamine (TOA) losses at the Modular Caustic-Side Solvent Extraction Unit (MCU) solvent. For this study, SRNL used partitioning and radiolysis data from the Oak Ridge National Laboratory (ORNL) as well as actual MCU operational data. From the radiolysis data, SRNL prepared a model on the rate of TOA degradation. From the combined sets of data, SRNL has calculated the largest possible value of TOA (although this value is not credible) in the Strip Effluent (SE) and also calculated two different conservative, more realistic values for TOA in the SE. Even under conservative assumptions, such as all of the TOA losses partitioning solely into the Strip Effluent (SE), the MCU operational data suggests that the maximum realistic TOA concentration in the SE is < 0.6 mg/L. Furthermore, from understanding the chemical differences between the old and new strip solutions, SRNL does not believe that the TOA will deplete from the blended BOBCalixC6 – Next Generation Solvent (NGS-MCU) at a rate higher than previously experienced. Finally, SRNL recommends pursuing analytical development of a method for TOA with a superior precision compared to the current method. However, as the TOA in the blended solvent will continuously decline during MCU operations, further improvements in the development of the understanding of TOA losses may not be cost effective.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗