Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Neutron Magnetic Form Factor GNM Measurement at High Q2 with CLAS12

The neutron magnetic form factor, GnM , is a fundamental quantity that describes how magnetic properties are distributed within a neutron. This measurement provides insights into the internal structure of the neutron. Furthermore, by measuring GnM alongside three other form factors (GnE , GpE , GpM ), we can test the predictions of Quantum Chromodynamics (QCD), which is the fundamental theory governing the strong force that binds quarks and gluons. Additionally, these measurements play a significant role in constraining Generalized Parton Distributions (GPDs) and contribute to determining the angular momentum of the quarks within nucleons. The GnM was measured using the ratio of quasi-elastic e ? n to e ? p scattering from a deuteron target. The measurement covered a range of four-momentum transfer squared, Q2, from 5 to 12 GeV2, using three different beam energies (10.2, 10.4, and 10.6 GeV). The data is compared with previous measurements and several theoretical models. The preliminary results reveal that Gn M exceeds the predictions of the standard dipole parametrization by 12-20%, based on RG-B pass1 data. It is expected that this deviation from the standard dipole parametrization will diminish as we transition to using RG-B pass2 data, aligning GnM more closely with the dipole form factor. The ongoing RG-B pass2 analysis in CLAS12 holds considerable promise for significant improvement. This enhancement is achievable through collaborative efforts aimed at refining tracking efficiency, momentum correction, calibration, and alignment.

Baashen, Lamya↗

Planck 2018 results. V. CMB power spectra and likelihoods

We describe the legacy Planck cosmic microwave background (CMB) likelihoods derived from the 2018 data release. The overall approach is similar in spirit to the one retained for the 2013 and 2015 data release, with a hybrid method using different approximations at low ( ℓ < 30) and high ( ℓ ≥ 30) multipoles, implementing several methodological and data-analysis refinements compared to previous releases. With more realistic simulations, and better correction and modelling of systematic effects, we can now make full use of the CMB polarization observed in the High Frequency Instrument (HFI) channels. The low-multipole EE cross-spectra from the 100 GHz and 143 GHz data give a constraint on the ΛCDM reionization optical-depth parameter τ to better than 15% (in combination with the TT low- ℓ data and the high- ℓ temperature and polarization data), tightening constraints on all parameters with posterior distributions correlated with τ . We also update the weaker constraint on τ from the joint TEB likelihood using the Low Frequency Instrument (LFI) channels, which was used in 2015 as part of our baseline analysis. At higher multipoles, the CMB temperature spectrum and likelihood are very similar to previous releases. A better model of the temperature-to-polarization leakage and corrections for the effective calibrations of the polarization channels (i.e., the polarization efficiencies) allow us to make full use of polarization spectra, improving the ΛCDM constraints on the parameters θ MC , ω c , ω b , and H 0 by more than 30%, and n s by more than 20% compared to TT-only constraints. Extensive tests on the robustness of the modelling of the polarization data demonstrate good consistency, with some residual modelling uncertainties. At high multipoles, we are now limited mainly by the accuracy of the polarization efficiency modelling. Using our various tests, simulations, and comparison between different high-multipole likelihood implementations, we estimate the consistency of the results to be better than the 0.5 σ level on the ΛCDM parameters, as well as classical single-parameter extensions for the joint likelihood (to be compared to the 0.3 σ levels we achieved in 2015 for the temperature data alone on ΛCDM only). Minor curiosities already present in the previous releases remain, such as the differences between the best-fit ΛCDM parameters for the ℓ < 800 and ℓ > 800 ranges of the power spectrum, or the preference for more smoothing of the power-spectrum peaks than predicted in ΛCDM fits. These are shown to be driven by the temperature power spectrum and are not significantly modified by the inclusion of the polarization data. Overall, the legacy Planck CMB likelihoods provide a robust tool for constraining the cosmological model and represent a reference for future CMB observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical Particle Measurements during EPCAPE Field Campaign Report

This campaign requested the deployment of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility optical particle counter (OPC) at the first ARM Mobile Facility (AMF1) located at the Scripps Pier in La Jolla, California during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE). The addition of the OPC was requested for two reasons. (1) Close the gap between the scanning mobility particle sizer (SMPS) and aerodynamic particle sizer (APS) size distribution from the Aerosol Observing System (AOS) measurements. (2) Principal investigator Petters has been working with Tracking Aerosol Convection Interaction Experiment (TRACER) data to compute particle fluxes from Doppler lidar (Petters et al. 2024). Briefly, backscatter flux is obtained using the eddy covariance technique using the Doppler vertical velocity and attenuated backscatter. Building upon prior studies, we were able to relate backscatter to particle number concentration by calibrating the lidar retrievals against optical particle counter-measured ground-based aerosol size distribution and radiosonde-interpolated relative humidity at lidar sample height. Performing similar analysis was of interest to EPCAPE to better understand the emissions and vertical transport of large particles into the overlying stratus clouds. However, as stated above, this analysis requires an optical size distribution that covers the 0.3-30-μm-diameter size range. The OPC was deployed between 2023-04-14 and 2024-02-14. The deployment, data quality analysis, and data archiving was handled by the DOE ARM instrument mentor team without additional involvement by the principal investigator. Data quality was marked as “routine” for the majority of the campaign.

54 ENVIRONMENTAL SCIENCES↗

Modeling the Effect of Surface Platinum–Tin Alloys on Propane Dehydrogenation on Platinum–Tin Catalysts

Uncertainty analysis, reported experimental literature data, and density functional theory were synthesized to model the effect of surface tin coverage on platinum-based catalysts for nonoxidative propane dehydrogenation to propylene. Here, this study tests four different platinum–tin skin surface models as potential catalytic sites, Pt 3 Sn/Pt(100), PtSn/Pt(100), Pt 3 Sn/Pt(111), and Pt 2 Sn/Pt(211), and compares them to the corresponding pure Pt surface sites using an uncertainty analysis methodology that uses BEEF-vdW with its ensembles (BMwE) to generate the uncertainty for the energies of the intermediates and transition states. One experimental data set with two experimental observations, selectivity to propylene and turnover frequency of propylene, was used as a calibration data set to evaluate the impact of the experimental data on informing the models. This study finds that the prior model for Pt 3 Sn/Pt(100) is the most active and Pt 2 Sn/Pt(211) is the most selective toward propylene. Active sites on the (100) facet have the highest probability of being responsible for C 1 and C 2 product formations (C–C bond cleavage). Increasing the Sn coverage on the (100) surface facet to a PtSn/Pt(100) active site leads to a significantly reduced rate and might explain the experimentally observed higher selectivity of Sn-doped catalysts relative to pure Pt catalysts. Next, this study finds that for all surfaces, except PtSn/Pt(100), the rate-controlling steps are the initial dehydrogenation steps alongside some partially rate-controlling second dehydrogenation steps. For PtSn/Pt(100), only the initial terminal dehydrogenation step to CH 3 CH 2 CH 2 * and second dehydrogenation steps are rate-controlling. Next, the calibrated models for all surfaces were found to be selective toward propylene production and model the reported turnover frequency successfully. Nevertheless, Pt 2 Sn/Pt(211) emerges as the active site with some (minor) evidence as the main active site based on Jeffreys’ scale interpretation of Bayes factors. This observation agrees with prior studies that also found step sites to be most likely the most relevant active sites for pure Pt catalysts. Overall, the results indicate that tin, in addition to affecting the binding strength of the adsorbed species, prevents deeper dehydrogenation (reducing coking) and cracking reactions through increasing activation barriers for unwanted side reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monte Carlo toolkit for designing and validating step-range-filter spectrometer designs

Here, we present a Monte Carlo toolkit for validating step range filter (SRF) spectrometer designs. Geant4 is used to transport charged particles through the SRF filters to generate synthetic SRF data that include realistic CR-39 effects. Synthetic SRF spectra generated by this method inherently account for instrument response and allow for the quantification of SRF performance before shots. The usefulness of this toolkit is demonstrated through its application to a number of problems. A new broadband SRF for the ∼10 MeV wide 3He3He proton spectrum is validated, and an analysis method for analyzing 3He3He-p SRF data that accounts for instrument response is put forth. In addition, an SRF design for the compact recoil-proton spectrometer (CRS) on the Z-machine is validated. Finally, a new calibration technique for the DD-p SRF is proposed and validated.

Johnson, T. M. (ORCID:0000000193032949)↗

Development of new baseline models for U.S. medium office buildings based on commercial buildings energy consumption survey data

Building energy estimation for the building sector under various scenarios are needed for building energy regulation and policy making. This often starts with representative baselines (either empirical baseline or modeled baseline). Commercial Buildings Energy Consumption Survey (CBECS) data is a widely used empirical baseline for U.S. commercial buildings, but none of the existing baseline model are developed to represent the CBECS data. This paper aims to develop new baseline models for the U.S. medium office buildings, which can produce modeled baselines consistent with the CBECS data. Here, we introduced the methodology to create baseline models and the criteria to evaluate the performance of baseline models. The methodology consists of three phases: (1) identification of model inputs, (2) model calibration, and (3) model validation with uncertainty analysis. The evaluation index is the coefficient of variation of the root-mean-square deviation (CV(RMSD)) of site energy use intensities (EUIs) between the modeled baseline and empirical baseline. Then 30 new baseline models for two vintages (pre- and post-1980) and 15 climate zones were created. The evaluation shows that the CV(RMSD) is lower than 0.05 for the modeled baselines produced by the new baseline models. As a comparison, the CV(RMSD) is higher than 0.1 for the existing modeled baselines generated by DOE Commercial Reference Building Models. Further analysis shows that the new baseline models are able to capture the uncertainties of the representative features of existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Saving Quantification on Ductless Heat Pump (DHP) in Existing Homes

In residential retrofit applications, ductless mini-split heat pumps (DHP) are often reported to have high-energy savings potential, depending on the system they are supplementing or replacing. However, recently, there have been a number of utility studies and analyses indicating these energy savings are not being achieved when the existing system is left in place for backup heating or air conditioning. The Pacific Northwest National Laboratory conducted a three-phase project to help determine which control strategies would have the most energy savings impact in various climate zones around the United States. The first phase developed the standalone simulation model for the PNNL Lab Homes and investigated the energy-saving potential from different control strategies and HVAC system configurations. The second phase focused on conducting experiments in the PNNL Lab Homes, which tested the most promising solutions that were modeled in the first phase. The third phase used the field data to calibrate the simulation model and then extrapolated the results to different climate locations and different building sizes. This report focuses on the third phase of the study, including five major parts: model calibration, parametric model setup, results, a sensitivity analysis of air leakage rate, and conclusions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement of the muon anomalous precession frequency at the Muon g − 2 Experiment at Fermilab

The anomalous magnetic moment of the muon, $a_\mu = \frac{g-2}{2}$ is the fractional deviation of the muon $g$-factor from the value of 2. It emerges as the cumulative effect of the virtual particles participating in the muon interaction with a magnetic field via quantum loop corrections. Its value encodes all the possible interactions between the virtual particles and, for this reason, represents an important test of the Standard Model (SM). In particular, any deviation from the SM theoretical evaluation could be due to new physics contributions. The new Muon $g-2$ (E989) Experiment at Fermilab is currently operating to repeat and improve the previous E821 experiment at Brookhaven National Laboratory (BNL), aiming to reduce the experimental error by a factor of 4 to the final accuracy of 140 parts per billion (ppb). On April 7th, 2021, the E989 collaboration published the first result based on the first year of data taking (Run-1), measuring $a_\mu = 0.001~165~920~40(54)$ with a precision of 460 ppb. The measured value is consistent with the BNL measurement and strengthens the long-standing tension with the data-driven SM prediction to a combined discrepancy of 4.2$\sigma$. On the theory side, however, new efforts involving lattice-QCD techniques are starting to question the current consensus on the theoretical prediction, demanding new improvements on both the experimental and theoretical sides. The E989 collaboration is now finalizing the analysis of Run-2 and Run-3 data and a new publication is expected in the first half of 2023 with a combined statistical uncertainty of 200 ppb. The anomalous magnetic moment $a_\mu$ is measured as the ratio between the muon spin anomalous precession frequency, $\omega_a$, and the average magnetic field experienced by the muons as they circulate in the storage ring. This thesis presents a precession frequency analysis of the Run-1 data and an evaluation of the related systematic uncertainties. A new positron reconstruction developed for the analysis of the subsequent data-taking periods, aiming to reduce some of the major systematic uncertainties of the $\omega_a$ measurement, is presented. The author's involvement in the production of the Run-2/5 data and in the precise calibration of the detectors is discussed. Finally, the complete Run-1 $a_\mu$ result is presented.

43 PARTICLE ACCELERATORS↗

Selection function of clusters in Dark Energy Survey year 3 data from cross-matching with South Pole Telescope detections

Context. Galaxy clusters selected based on overdensities of galaxies in photometric surveys provide the largest cluster samples. However, modeling the selection function of such samples is complicated by noncluster members projected along the line of sight (projection effects) and the potential detection of unvirialized objects (contamination). Aims. We empirically constrained the magnitude of these effects by cross-matching galaxy clusters selected in the Dark Energy Survey data with the redMaPPer algorithm with significant detections in three South Pole Telescope surveys (SZ, pol-ECS, pol-500d). Methods. For matched clusters, we augmented the redMaPPer catalog with the SPT detection significance. For unmatched objects we used the SPT detection threshold as an upper limit on the SZe signature. Using a Bayesian population model applied to the collected multiwavelength data, we explored various physically motivated models to describe the relationship between observed richness and halo mass. Results. Our analysis reveals a clear preference for models with an additional skewed scatter component associated with projection effects over a purely log-normal scatter model. We rule out significant contamination by unvirialized objects at the high-richness end of the sample. While dedicated simulations offer a well-fitting calibration of projection effects, our findings suggest the presence of redshift-dependent trends that these simulations may not have captured. Our findings highlight that modeling the selection function of optically detected clusters remains a complicated challenge that requires a combination of simulation and data-driven approaches.

79 ASTRONOMY AND ASTROPHYSICS↗

Searches for New Physics With Muon Conversion at Fermilab and Triboson Production at the LHC

We report on several efforts to search for physics beyond the standard model of particle physics at broad energy scales. The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the muon to electron conversion process, which is suppressed in the Standard Model. Mu2e will be operated at a low energy, yet can probe New Physics at very high mass scales (O(1e3 - 1e4 ) TeV). At high energies, the CMS experiment at the CERN LHC continues to deliver an impressive suite of Standard Model measurements and limits on a variety of New Physics signatures. Mu2e is under construction and slated to collect its first physics data in the coming years. This thesis describes work done during the construction phase of Mu2e and focuses on two critical areas: magnetic field modeling and statistical analysis. We describe a novel method for field modeling which we validate using a simulated dataset representing the expected magnetic field in the Detector Solenoid. This method blends a standard least-squares fitting technique that utilizes physically motivated analytical model functions with a novel physics informed network that is constructed to obey Maxwell’s equations. We show the technique can model the field with an accuracy of 10−7 despite the presence of injected noise in the pseudo-measurements at the 10−5 level. We then present preliminary results of the calibration of 3D Hall probes at the sub-10−4 level. These probes will be used to directly measure the Mu2e Detector Solenoid magnetic field on a sparse grid; these measurements serve as the input to the field model fitting. Finally, we describe the first implementation of both an unbinned shape analysis and a Bayesian interpretation applied to Mu2e pseudo-data. Up to 20% tighter limits can be set by the shape analysis compared to a standard cut & count analysis. The AlCap experiment collected data at PSI in 2015 to measure several important quantities related to nuclear muon capture on an aluminum target, which is a significant background process for Mu2e. The neutron emission from muon capture can introduce background hits in the Mu2e detectors and can increase radiation damage in various elements of the apparatus. We present measurements of the neutron group fluence and mean neutron multiplicity for muon capture on aluminum nuclei. Finally, we discuss an analysis of triboson production at CMS using an Effective Field Theory framework. Standard Model triboson production, which was first observed at CMS in 2020, has a relatively small cross section and provides direct access to both anomalous triple gauge couplings and quartic gauge couplings. These couplings, interpreted in the Standard Model Effective Field Theory, are studied in the present work. We target the boosted regime where the background rate is low and yields are enhanced when dimension-6 and dimension-8 Wilson coefficients are non-zero. We do not observe an excess in the data and therefore set bounds on the Wilson coefficients. For dimension-6 coefficients the tightest observed (expected) bounds are set on cW /Λ2 where Λ is the mass scale of new physics; the bounds are [−0.13, 0.12] TeV−2 ([−0.12, 0.12] TeV−2 ) at 95% CL. The tightest bounds in dimension-8 are set on fT,0 / Λ4 ; the observed (expected) bounds at 95% CL are [−0.63, 0.69] TeV−4 ([−0.54, 0.62] TeV−4 ). Additional results are presented which include scenarios where multiple Wilson coefficients are non-zero, the application of signal model clipping to address unitarity violation in Effective Field Theories, and a novel template fit developed for easier reinterpretation of our results.

Kampa, Cole Erik [Northwestern U. (main)] (ORCID:0↗

Calibration of a mesoscale tritium transport model for ceramic breeder materials in TMAP8 using experimental data

Due to the scarcity of the long-term external tritium supply, lithium-containing breeder materials are used in the blanket of fusion reactors to produce tritium faster than the deuterium-tritium fusion reaction consumes it. A cellular breeder is a promising material with higher lithium density and thermal conductivity than conventional ceramic pebbles and enhanced tritium extraction with interconnected pores. Although several experimental and modeling efforts have improved our understanding of tritium transport, the exact mechanisms governing tritium release from breeder materials are still unknown. As a result, current models cannot reliably assess the tritium breeding capabilities of cellular breeder materials. This work presents a tritium transport multiphysics model and calibrates it using experimental data of deuterium absorption and desorption from cellular breeder materials at different temperatures and pressures. This model accounts for ceramic and pore diffusion, trapping and detrapping, and several surface reactions at the pore surface. After calibrating the model and performing sensitivity analysis, we discuss pre-dominant mechanisms governing tritium release from cellular breeder materials. The model is part of the Tritium Migration Analysis Program [TMAP8], a multiscale, multiphysics framework for tritium transport based on the finite element multiphysics framework MOOSE. This study demonstrates some of TMAP8’s capabilities and provides insight into the mechanisms governing tritium transport in cellular ceramic breeder materials.

08 HYDROGEN↗

Chemometrics and Experimental Design for the Quantification of Nitrate Salts in Nitric Acid: Near-Infrared Spectroscopy Absorption Analysis

Implementing remote, real-time spectroscopic monitoring of radiochemical processing streams in hot cell environments requires efficiency and simplicity. The success of optical spectroscopy for the quantification of species in chemical systems highly depends on representative training sets and suitable validation sets. Selecting a training set (i.e., calibration standards) to build multivariate regression models is both time- and resource-consuming using standard one-factor-at-a-time approaches. This study describes the use of experimental design to generate spectral training sets and a validation set for the quantification of sodium nitrate (0–1 M) and nitric acid (0.1–10 M) using the near-infrared water band centered at 1440 nm. Partial least squares regression models were built from training sets generated by both D- and I-optimal experimental designs and a one-factor-at-a-time approach. The prediction performance of each model was evaluated by comparing the bias and standard error of prediction for statistical significance. D- and I-optimal designs reduced the number of samples required to build regression models compared with one-factor-at-a-time while also improving performance. Models must be confirmed against a validation sample set when minimizing the number of samples in the training set. The D-optimal design performed the best when considering both performance and efficiency by improving predictive capability and reducing number of samples in the training set by 64% compared with the one-factor-at-a-time approach. The experimental design approach objectively selects calibration and validation spectral data sets based on statistical criterion to optimize performance and minimize resources.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Fork Experiments in the Hot Cell Using Spent Fuel Rods for International Nuclear Safeguards

This work leveraged the rare availability of 25 full-length pressurized water reactor spent fuel rods and 1 irradiated mixed-oxide rod at an Oak Ridge National Laboratory hot cell. This was done to collect measurement data with two Fork detectors to assess the detectors’ capability of verifying operator declaration data and detecting partial defects in spent fuel, which are the two primary goals of international safeguards on spent nuclear fuel. The data can also be used to benchmark the ORIGEN module, which has been adopted in the International Atomic Energy Agency’s (IAEA’s)/European Atomic Energy Community’s (Euratom’s) Integrated Review and Analysis Program to predict the Fork detector count rates in real time. In this project, the authors first calibrated two Fork detectors—a standard one and a modified one—by using known strong neutron and gamma sources. Then, the authors measured all 26 fuel rods at multiple locations along the length. The fuel rods were then assembled into three arrays—2 × 2, 3 × 3, and 5 × 5—by using specially designed support grids to mimic fuel assemblies and measure the arrays with both detectors. For the 5 × 5 array, 4 and 8 fuel rods of the array were replaced in two separate cases with short stainless-steel rods to mimic two partial defect scenarios, and the arrays were measured before and after the replacements. Polyethylene blocks were used in this experiment to mimic water. The results show that the Fork detectors were able to verify operator declarations and detect partial defects in spent fuel, and the authors were the first to demonstrate this through experiments. A discovery was also made that determined the root cause of the nonlinear response to gamma dose in the ion chambers used in IAEA and Euratom’s Fork detectors. After the experiments, both detectors were retrieved from the hot cell for future use. The data collected in this project will be used in a parallel International Nuclear Safeguards Engagement Program (INSEP) project to enhance the safeguards in the Finnish spent fuel encapsulation plant, and the data will be useful to other projects in the future given the increased safeguards needs due to spent fuel transfer and disposal activities worldwide.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Uncertainty about the Uncertainty [Slides]

A golden standard in science is to repeat an experiment a statistically significant number of times, recording data using the same set of detectors and the same data analysis methodology. In such case experimental error includes both the range of true values generated by repetitions of the experiment, and measurement uncertainty caused by the detector. They are independent. It is a huge and too frequently used simplification, to assume that one can measure multiple repetitions of an identical experiment, resulting in identical true experimental value. Repetitions, as similar is it is experimentally achievable result in a range of the true values rather than in a single value. When modern, very sensitive and well calibrated measurement systems are used, this range is not negligible, and sometimes dominates, in comparison to the measurement uncertainty. Range of true values depends on the physics of the experiment, while measurement uncertainty depends on the measurement method (properties of the detector not of the experiment). When data from one–of–a kind experiment are analyzed, only the measurement uncertainty is reported. It gives no information about the range, in which the true values of experiment would spread if the experiment was repeated. A frequently used approximation, that if a physical quantity is measured as a function of time, only measurement of this quantity, produces uncertainty is also in some real experiments fare to strong. Example: In reaction history time measurement uncertainty propagated to alpha dominated under certain conditions over the flux measurement uncertainty propagated to alpha. Reliability of a data point is in general independent from its measurement uncertainty. However, in practice reliable measurement methods frequently have high measurement uncertainty, while low reliability methods are applied to limit measurement uncertainty. Comparison of reliable data with high measurement uncertainty to not so reliable data measured with low uncertainty is discussed – in different scenarios different data analysis methods are applicable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shock initiation of the HMX-based explosive PBX 9012: Experiments, uncertainty analysis, and unreacted equation-of-state

In this study, shock initiation experiments have been carried out on the polymer-bonded explosive PBX 9012 [nominally 90% octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazine (HMX), 10% vinylidene–hexafluoropropylene copolymer (Viton A) by weight] in order to provide calibration data for the explosive’s unreacted equation-of-state (EOS) and shock-to-detonation transition for reactive burn rate calibration. The input pressures covered the range of 1.86–4.43 GPa. This provided run-to-detonation depths ranging from > 22.3 mm for the lowest pressure shot to 4.91 mm at the highest pressure. The relative shock sensitivity of PBX 9012 is compared to other HMX-explosives in terms of the Pop-plot, showing that the studied explosive is more sensitive than other similar HMX-based counterparts (with notable exceptions). The uncertainty in the shock velocity determinations from the shock tracker measurements are also investigated, yielding new uncertainty measures in the generated Hugoniot data and run-to-detonation coordinates. Finally, the unreacted equation-of-state is determined using a linear U s – u p Mie–Grüneisen relation and the Davis reactants EOS analytical form, the latter being more suited for reactive burn modeling.

36 MATERIALS SCIENCE↗

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The Muon g - 2 experiment at Fermilab (E989) aims to measure the anomalous magnetic moment, a μ , of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, ω α , of muons stored in a magnetic field of 1.45 T, and a precise measurement of that magnetic field in terms of the shielded proton Larmor frequency, ω' ρ . The measurement of ω' ρ with a total systematic uncertainty of 70 parts-perbillion involves a combination of various nuclear magnetic resonance (NMR) probes. There are 378 probes mounted in fixed locations that constantly monitor field drifts. A water-based, cylindrical calibration probe provides the calibration in terms of the shielded proton Larmor frequency. A crucial element for the multi-step measurement of ω' ρ is the regular mapping of the magnetic field over the muon storage region. The former experiment at Brookhaven National Laboratory (BNL) employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include the addition of 16-bit, 1 MSPS digitization of the NMR signals, which replaced the hardware-implemented zero-crossing counting of the system at Brookhaven. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. To sustain the higher data rates, a new communication scheme with time-division multiplexing was implemented to separate the important NMR reference clock from the data communication in order to reach the specifications for the accuracy and stability of the reference clock. A new barcode reader provides more precise azimuthal position determination during the measurement and calibration. While the mechanical systems that move the field mapper inside the storage ring have been mostly refurbished from BNL, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first three data taking periods of the experiment at Fermilab. Finally, this article will provide the details of the upgrades of the field mapper and its performance.

47 OTHER INSTRUMENTATION↗

Control-Oriented Modeling of Cycle-to-Cycle Combustion Variability at the Misfire Limit in SI Engines

A control-oriented model is presented that can capture the prior-cycle correlation of combustion cycles during conditions with high levels of exhaust gas recirculation (EGR). Combustion events are modeled in discrete time and the dynamic evolution is captured by the residual air, fuel, and inert gas trapped in the combustion chamber. The mathematical formulation of the model is presented together with the calibration procedure to emulate a particular engine operating condition. A cycle-to-cycle system identification methodology is described which allows regressing model parameters from experimental data. Simulations are presented and compared to real engine measurements to show the modeling potential for analysis and control of combustion events.

Maldonado Puente, Bryan↗

Analysis and Integration of the Hydraulic Fracturing Test Site-2 (HFTS-2) Comprehensive Dataset

Hydraulic Fracturing Test Site-2 (HFTS-2) is a field-based research experiment performed in the Permian (Delaware) Basin. The unique aspect of this program was the acquisition of a unique, comprehensive, diagnostic dataset. Additionally, shorter parent wells drilled three years before the child wells offered clear distinction between the stages influenced by parent-child effects and the stages without any effects. The goal of this study was to analyze and integrate this comprehensive diagnostic dataset to understand the areal and vertical extent of hydraulic fractures (HF). The paper also provides insights on the effects of parent wells’ depletion on child well HF geometry based on various monitoring methods and subsurface models. Areal and vertical coverage for all HFTS-2 wells during stimulation and depletion was estimated based on analysis and interpretation of diagnostics and advanced modeling results. HFTS-2 diagnostics included microseismic (MS), pre- and post-stimulation logs and cores, bottomhole gauges, and fiber optic (FO) data. The diagnostics results (MS, FO, image logs) were integrated and used to calibrate subsurface models. Additional field tests were designed and implemented for depletion monitoring. The tailored program for monitoring depletion included vertical and slant well pressures, interference testing, and a vertical strain depletion trial. Areal Coverage: Conventional MS (and FO MS) were used to compute HF dimensions, which were compared with diagnostics (FO strain, gauge, image logs) observations and calibrated subsurface models. A post-production interference test did not show offset well communication. Vertical Coverage: Vertical coverage during stimulation was monitored using a vertical monitoring well. The stronger mechanical strain signals showed good correlation with MS event intensities, geomechanical properties, and gauge inferences. Vertical depletion was estimated based on vertical/slant well gauges and strain depletion tests. Parent-Child Effects: Diagnostics and calibrated subsurface models show asymmetry in child well fracture geometries for stages that overlap parent wells. Child well image logs serve as a good indicator for parent Downloaded from http://onepetro.org/URTECONF/proceedings-pdf/21URTC/2-21URTC/D021S031R004/2477423/urtec-2021-5241-ms.pdf/1 by Carol Worster on 28 February 2022 URTeC 5241 well HF tracking. Child well MS events had an eastward bias, in line with pre-stimulation image logs, and was confirmed by parent well frac hits. Novel/Additive Information: The dataset presents a unique, over-constrained problem space to compare independent techniques to arrive at HF metrics (i.e., stimulation height and/or half-length), unlike a single source dataset, in which calibration is done using available data to guide predictions. Here, the asymmetry in HF geometry seen in the stages influenced by parent-child effects offers unique insights into well spacing and landing, which are key capital decisions the unconventional resources industry is seeking to optimize.

58 GEOSCIENCES↗