Search NASA⌕ Search

SEARCH · Search NASA

Results for “capacitance sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Fast timing with induced current detectors

Vertically integrated (3D) combinations of sensors and electronics offer the ability to fabricate small, fine pitch pixels with very small total capacitance monolithically integrated with complex circuitry. The small capacitance, enabled by the fine pixel pitch and low interconnect capacitance available in 3D hybrid bonding, provides excellent signal/noise with moderate power. This combination enables fabrication of integrated sensors and electronics with both excellent position and time resolution. We describe the capabilities of such a system and the limitations imposed by geometry and power. Furthermore, we illustrate how a similar geometry can be used to provide very fast timing of x-ray arrival in a thick sensor by utilizing the transient induced current in a field of pixels.

3D integration↗

Integration and Packaging

Vertically integrated (3D) combinations of sensors and electronics provide the ability to fabricate small, fine pitch pixels with very small total capacitance monolithically integrated with complex circuitry. The small capacitance, enabled by the fine pixel pitch and low interconnect capacitance available in 3D hybrid bonding, provides excellent signal/noise with moderate power. This combination enables fabrication of integrated sensors and electronics with both excellent position and time resolution. In this white paper a discussion will be presented on 3D integration advantages, ongoing projects and prospects in high energy physics and beyond.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magneto-inductive skin sensor for robot collision avoidance: A new development

Safety is a primary concern for robots operating in space. The tri-mode sensor addresses that concern by employing a collision avoidance/management skin around the robot arms. This rf-based skin sensor is at present a dual mode (proximity and tactile). The third mode, pyroelectric, will complement the other two. The proximity mode permits the robot to sense an intruding object, to range the object, and to detect the edges of the object. The tactile mode permits the robot to sense when it has contacted an object, where on the arm it has made contact, and provides a three-dimensional image of the shape of the contact impression. The pyroelectric mode will be added to permit the robot arm to detect the proximity of a hot object and to add sensing redundancy to the two other modes. The rf-modes of the sensing skin are presented. These modes employ a highly efficient magnetic material (amorphous metal) in a sensing technique. This results in a flexible sensor array which uses a primarily inductive configuration to permit both capacitive and magnetoinductive sensing of object; thus optimizing performance in both proximity and tactile modes with the same sensing skin. The fundamental operating principles, design particulars, and theoretical models are provided to aid in the description and understanding of this sensor. Test results are also given.

Chauhan, D. S.↗

Diode-quad bridge for reactive transducers and FM discriminators

Diode-quad bridge circuit was developed for use with pressure-sensitive capacitive transducers, liquid-level measuring devices, proximity deflection sensors, and inductive displacement sensors. It may also be used as FM discriminator and as universal impedance bridge.

Harrison, D. R.↗

The Development of a PdCr Integral Weldable Strain Measurement System Based on NASA Lewis PdCr/Pt Strain Sensor for User-Friendly Elevated Temperature Strain Measurements

This report describes the development of a user friendly weldable strain gage employing the NASA Lewis PdCr/Pt wire strain sensor. The NASA sensors are pre-attached to Hastelloy X or Titanium alloy shims using name spray techniques developed under previous NASA programs. The weldable sensors are then pre-stabilized for 50 hours at 780 C in air. A weldable terminal and high temperature cable is then connected to the sensor and the assembly is pre-calibrated over the full test temperature range. Calibrated resistors are inserted into a bridge completion module at the cool end of the cable to condition the sensor in half or full bridge configuration. The sensor is attached to the structure using a common capacitive discharge spot welder. No additional high temperature stabilization or calibration is required. The resultant device is a pre-calibrated strain transducer which can be plugged into any common variety strain instrumentation.

Wnuk, S. P., Jr.↗

Evaluation of the Bulk and Strip Characteristics of Large Area n-in-p Silicon Sensors Intended for a Very High Radiation Environment

The ATLAS collaboration R&D group 'Development of n-in-p Silicon Sensors for very high radiation environment' has developed single-sided p-type 9.75 cm x 9.75 cm sensors with an n-type readout strips having radiation tolerance against the 10{sup 15} 1-MeV neutron equivalent (n{sub eq})/cm{sup 2} fluence expected in the Super Large Hadron Collider. The compiled results of an evaluation of the bulk and strip parameter characteristics of 19 new non-irradiated sensors manufactured by Hamamatsu Photonics are presented in this paper. It was verified in detail that the sensors comply with the technical specifications required before irradiation. The reverse bias voltage dependence of various parameters, frequency dependence of tested capacitances, and strip scans of more than 23,000 strips as a test of parameter uniformity and strip quality over the whole sensor area have been carried out at Stony Brook University, Cambridge University, University of Geneva, and Academy of Sciences of CR and Charles University in Prague. No openings, shorts, or pinholes were observed on all tested strips, confirming the high quality of sensors made by Hamamatsu Photonics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing novel Indium Phosphide pad detectors with focused X-ray beams and laboratory tests

Future tracking systems in High Energy Physics experiments will require large instrumented areas with low radiation length. Crystalline silicon sensors have been used in tracking systems for decades, but are difficult to manufacture and costly to produce for large areas. We are exploring alternative sensor materials that are amenable to fast fabrication techniques used for thin film devices. Indium Phosphide pad sensors were fabricated at Argonne National Lab using commercially available InP:Fe 2-inch mono-crystal substrates. Current-voltage and capacitance-voltage characterizations were performed to study the basic operating characteristics of a group of sensors. Micro-focused X-ray beams at Canadian Light Source and Diamond Light Source were used to study the response to ionizing radiation, and characterize the uniformity of the response for several devices. Electrical test results showed a high degree of performance uniformity between the 48 tested devices. X-ray test beam results showed good performance uniformity within tested devices after accounting for spatially-local defects and edge fields. As a result, this motivates further studies into thin film devices for future tracking detectors.

47 OTHER INSTRUMENTATION↗

Micro-system inertial sensing technology overview.

The purpose of this report is to provide an overview of Micro-System technology as it applies to inertial sensing. Transduction methods are reviewed with capacitance and piezoresistive being the most often used in COTS Micro-electro-mechanical system (MEMS) inertial sensors. Optical transduction is the most recent transduction method having significant impact on improving sensor resolution. A few other methods are motioned which are in a R&D status to hopefully allow MEMS inertial sensors to become viable as a navigation grade sensor. The accelerometer, gyroscope and gravity gradiometer are the type of inertial sensors which are reviewed in this report. Their method of operation and a sampling of COTS sensors and grade are reviewed as well.

99 GENERAL AND MISCELLANEOUS↗

A Threshold Helium Leakage Detection Switch with Ultra Low Power Operation

Detecting helium leakage is important in many applications, such as in dry cask nuclear waste storage systems. This work develops a helium detection system based on the relative permittivity (dielectric constant) difference between air and helium. This difference changes the status of an electrostatic microelectromechanical system (MEMS) switch. The switch is a capacitive-based device and requires a very negligible amount of power. Exciting the switch’s electrical resonance enhances the MEMS switch sensitivity to detect low helium concentration. This work simulates two different MEMS switch configurations: a cantilever-based MEMS modeled as a single-degree-freedom model and a clamped-clamped beam MEMS molded using the COMSOL Multiphysics finite-element software. While both configurations demonstrate the switch’s simple operation concept, the clamped-clamped beam was selected for detailed parametric characterization due to its comprehensive modeling approach. The beam detects at least 5% helium concentration levels when excited at 3.8 MHz, near electrical resonance. The switch performance decreases at lower excitation frequencies or increases the circuit resistance. The MEMS sensor detection level was relatively immune to beam thickness and parasitic capacitance changes. However, higher parasitic capacitance increases the switch’s susceptibility to errors, fluctuations, and uncertainties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Testbeam results of irradiated ams H18 HV-CMOS pixel sensor prototypes

HV-CMOS pixel sensors are a promising option for the tracker upgrade of the ATLAS experiment at the LHC, as well as for other future tracking applications in which large areas are to be instrumented with radiation-tolerant silicon pixel sensors. We present results of testbeam characterisations of the 4 th generation of Capacitively Coupled Pixel Detectors (CCPDv4) produced with the ams H18 HV-CMOS process that have been irradiated with different particles (reactor neutrons and 18 MeV protons) to fluences between 1×10 14 and 5×10 15 1–MeV– n eq . The sensors were glued to ATLAS FE-I4 pixel readout chips and measured at the CERN SPS H8 beamline using the FE-I4 beam telescope. Results for all fluences are very encouraging with all hit efficiencies being better than 97% for bias voltages of 85 V. The sample irradiated to a fluence of 1×10 15 neq—a relevant value for a large volume of the upgraded tracker—exhibited 99.7% average hit efficiency. Furthermore, the results give strong evidence for the radiation tolerance of HV-CMOS sensors and their suitability as sensors for the experimental HL-LHC upgrades and future large-area silicon-based tracking detectors in high-radiation environments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Disruptive Chemical Approach to Modify Perovskites for Chemical and Biological Sensors

We have been investigating CaCu3Ti4O12 class of perovskites for variety of applications due to its very large dielectric constant. Several mechanisms have been proposed for the existence of the high dielectric constant based on grain boundaries and oxygen deficiencies. We will report the results of the effects of monovalent substitution to replace calcium. This will alter the size to distort the perovskite structure. In addition, we used this system as a sensor for organic agents. There were very large changes in dielectric constant and resistivity indicating this system as a very good sensor material.

Perovskites↗

Microfabricated ion trap chip with in situ radio-frequency sensing

A radio-frequency (RF) surface ion trap chip includes an RF electrode and an integrated capacitive voltage divider in which an intermediate voltage node is capacitively connected between the RF electrode and a ground. A sensor output trace is connected to the intermediate voltage node.

Maunz, Peter Lukas Wilhelm↗

Time varying voltage combustion control and diagnostics sensor

A time-varying voltage is applied to an electrode, or a pair of electrodes, of a sensor installed in a fuel nozzle disposed adjacent the combustion zone of a continuous combustion system, such as of the gas turbine engine type. The time-varying voltage induces a time-varying current in the flame which is measured and used to determine flame capacitance using AC electrical circuit analysis. Flame capacitance is used to accurately determine the position of the flame from the sensor and the fuel/air ratio. The fuel and/or air flow rate (s) is/are then adjusted to provide reduced flame instability problems such as flashback, combustion dynamics and lean blowout, as well as reduced emissions. The time-varying voltage may be an alternating voltage and the time-varying current may be an alternating current.

47 OTHER INSTRUMENTATION↗

Mutual capacitance of liquid conductors in deformable tactile sensing arrays

Advances in highly deformable electronics are needed in order to enable emerging categories of soft computing devices ranging from wearable electronics, to medical devices, and soft robotic components. The combination of highly elastic substrates with intrinsically stretchable conductors holds the promise of enabling electronic sensors that can conform to curved objects, reconfigurable displays, or soft biological tissues, including the skin. Here, we contribute sensing principles for tactile (mechanical image) sensors based on very low modulus polymer substrates with embedded liquid metal microfluidic arrays. The sensors are fabricated using a single-step casting method that utilizes fine nylon filaments to produce arrays of cylindrical channels on two layers. The liquid metal (gallium indium alloy) conductors that fill these channels readily adopt the shape of the embedding membrane, yielding levels of deformability greater than 400%, due to the use of soft polymer substrates. We modeled the sensor performance using electrostatic theory and continuum mechanics, yielding excellent agreement with experiments. Using a matrix-addressed capacitance measurement technique, we are able to resolve strain distributions with millimeter resolution over areas of several square centimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characteristics of Various Photodiode Structures in CMOS Technology with Monolithic Signal Processing Electronics

Monolithic optical sensor with readout electronics are needed in optical communication, medical imaging and scintillator based gamma spectroscopy system. This paper presents the design of three different CMOS photodiode test structures and two readout channels in a commercial CMOS technology catering to the need of nuclear instrumentation. The three photodiode structures each of 1 mm{sup 2} with readout electronics are fabricated in 0.35 um, 4 metal, double poly, N-well CMOS process. These photodiode structures are based on available P-N junction of standard CMOS process i.e. N-well/P-substrate, P+/N-well/P-substrate and inter-digitized P+/N-well/P-substrate. The comparisons of typical characteristics among three fabricated photo sensors are reported in terms of spectral sensitivity, dark current and junction capacitance. Among the three photodiode structures N-well/P-substrate photodiode shows higher spectral sensitivity compared to the other two photodiode structures. The inter-digitized P+/N-well/P-substrate structure has enhanced blue response compared to N-well/P-substrate and P+/N-well/P-substrate photodiode. Design and test results of monolithic readout electronics, for three different CMOS photodiode structures for application related to nuclear instrumentation, are also reported.

36 MATERIALS SCIENCE↗

Epidermal Impedance Sensing Sheets for Precision Hydration Assessment and Spatial Mapping

This paper presents a class of hydration monitor that uses ultrathin, stretchable sheets with arrays of embedded impedance sensors for precise measurement and spatially multiplexed mapping. The devices contain miniaturized capacitive electrodes arranged in a matrix format, capable of integration with skin in a conformal, intimate manner due to the overall skin-like physical properties. These “epidermal” systems noninvasively quantify regional variations in skin hydration, at uniform or variable skin depths. Experimental results demonstrate that the devices possess excellent uniformity, with favorable precision and accuracy. Theoretical models capture the underlying physics of the measurement and enable quantitative interpretation of the experimental results. Furthermore, these devices are appealing for applications ranging from skin care and dermatology, to cosmetology and health/wellness monitoring, with the additional potential for combined use with other classes of sensors for comprehensive, quantitative physiological assessment via the skin.

42 ENGINEERING↗

Performance of CMOS pixel sensor prototypes in ams H35 and aH18 technology for the ATLAS ITk upgrade

Pixel sensors based on commercial high-voltage CMOS processes are an exciting technology that is considered as an option for the outer layer of the ATLAS inner tracker upgrade at the High Luminosity LHC. Here, charged particles are detected using deep n-wells as sensor diodes with the depleted region extending into the silicon bulk. Both analog and digital readout electronics can be added to achieve different levels of integration up to a fully monolithic sensor. Small scale prototypes using the ams CMOS technology have previously demonstrated that it can achieve the required radiation tolerance of 10(15) n(eq)/cm(2) and detection efficiencies above 99.5%. Recently, large area prototypes, comparable in size to a full sensor, have been produced that include most features required towards a final design: the H35demo prototype produced in ams H35 technology that supports both external and integrated readout and the monolithic ATLASPix1 pre-production design produced in ams aH18 technology. Both chips are based on large fill-factor pixel designs, but differ in readout structure. Performance results for H35DEMO with capacitively-coupled external readout and first results for the monolithic ATLASPix1 are shown.

ATLAS ITk upgrade↗