At least 307 records · Page 17

FOSWEC dynamics and controls test report

This report describes the testing of a model scale wave energy converter. This device, which uses two aps that pivot about a central platform when excited by waves, has a natural frequency within the range of the waves by which it is excited. The primary goal of this test was to assess the degree to which previously developed modeling, experimentation, and control design methods could be applied to a broad range of wave energy converter designs. Testing was conducted to identify a dynamic model for the impedance and excitation behavior of the device. Using these models, a series of closed loop tests were conducted using a causal impedance matching controller. This report provides a brief description of the results, as well as a summary of the device and ex- perimental design. The results show that the methods applied to this experimental device perform well and should be broadly applicable.

16 TIDAL AND WAVE POWER↗

Automated control and optimization of laser-driven ion acceleration

The interaction of relativistically intense lasers with opaque targets represents a highly non-linear, multi-dimensional parameter space. This limits the utility of sequential 1D scanning of experimental parameters for the optimization of secondary radiation, although to-date this has been the accepted methodology due to low data acquisition rates. High repetition-rate (HRR) lasers augmented by machine learning present a valuable opportunity for efficient source optimization. Here, an automated, HRR-compatible system produced high-fidelity parameter scans, revealing the influence of laser intensity on target pre-heating and proton generation. A closed-loop Bayesian optimization of maximum proton energy, through control of the laser wavefront and target position, produced proton beams with equivalent maximum energy to manually optimized laser pulses but using only 60% of the laser energy. This demonstration of automated optimization of laser-driven proton beams is a crucial step towards deeper physical insight and the construction of future radiation sources.

47 OTHER INSTRUMENTATION↗

Machine Learning-Based Model Predictive Control of Two-Time-Scale Systems

In this study, we present a general form of nonlinear two-time-scale systems, where singular perturbation analysis is used to separate the dynamics of the slow and fast subsystems. Machine learning techniques are utilized to approximate the dynamics of both subsystems. Specifically, a recurrent neural network (RNN) and a feedforward neural network (FNN) are used to predict the slow and fast state vectors, respectively. Moreover, we investigate the generalization error bounds for these machine learning models approximating the dynamics of two-time-scale systems. Next, under the assumption that the fast states are asymptotically stable, our focus shifts toward designing a Lyapunov-based model predictive control (LMPC) scheme that exclusively employs the RNN to predict the dynamics of the slow states. Additionally, we derive sufficient conditions to guarantee the closed-loop stability of the system under the sample-and-hold implementation of the controller. A nonlinear chemical process example is used to demonstrate the theory. In particular, two RNN models are constructed: one to model the full two-time-scale system and the other to predict solely the slow state vector. Both models are integrated within the LMPC scheme, and we compare their closed-loop performance while assessing the computational time required to execute the LMPC optimization problem.

97 MATHEMATICS AND COMPUTING↗

Output Feedback Stabilization for a Class of Multi-Variable Bilinear Stochastic Systems with Stochastic Coupling Attenuation

In this paper, stochastic coupling attenuation is investigated for a class of multi-variable bilinear stochastic systems and a novel output feedback m-block backstepping controller with linear estimator is designed, where gradient descent optimization is used to tune the design parameters of the controller. It has been shown that the trajectories of the closed-loop stochastic systems are bounded in probability sense and the stochastic coupling of the system outputs can be effectively attenuated by the proposed control algorithm. Moreover, the stability of the stochastic systems is analyzed and the effectiveness of the proposed method has been demonstrated using a simulated example.

47 OTHER INSTRUMENTATION↗

Lab-Scale, Closed-Loop Experimental Characterization, Model Refinement, and Validation of a Hydrokinetic Energy-Harvesting Ocean Kite

This paper presents a study wherein we experimentally characterize the dynamics and control system of a lab-scale ocean kite, and then refine, validate, and extrapolate this model for use in a full-scale system. Ocean kite systems, which harvest tidal and ocean current resources through high-efficiency cross-current motion, enable energy extraction with an order of magnitude less material (and cost) than stationary systems with the same rated power output. However, an ocean kite represents a nascent technology that is characterized by relatively complex dynamics and requires sophisticated control algorithms. In order to characterize the dynamics and control of ocean kite systems rapidly, at a relatively low cost, the authors have developed a lab-scale, closed-loop prototyping environment for characterizing tethered systems, whereby 3D printed systems are tethered and flown in a water channel environment. While this system has been shown to be capable of yielding similar dynamic characteristics to some full-scale systems, there are also fundamental limitations to the geometric scales and flow speeds within the water channel environment, making many other real-world scenarios impossible to replicate from the standpoint of dynamic similarity. Here, to address these scenarios, we show how the lab-scale framework is used to refine and validate a scalable dynamic model of a tethered system, which can then be extrapolated to full-scale operation. In this work, we present an extensive case study of this model refinement, validation, and extrapolation on an ocean kite system intended for operation in the Gulf Stream or similar current environments.

42 ENGINEERING↗

Heliostat Observation System Commercialization Qualification HOS-C-Q (Final Technical Report)

Heliostat fields are one of the main components of a concentrated solar thermal plant. As GEN3 technology has been developed at pilot plant level targeting higher temperatures >700C, having a precise Heliostat field control system will enable the success of the GEN3 technology. Heliogen Inc. has developed the next generation of control systems for heliostat fields. Their early development was on single facet heliostats at their R&D facility in Lancaster, California. This new system allows for a closed loop integration to a current open loop setup of a regular Heliostat control system. Sandia National Laboratories and Heliogen Inc. have partnered together to test Heliogen’ s innovative new SOHOT system at the National Solar Thermal Test Facility.

14 SOLAR ENERGY↗

Paper #50 Preliminary Sizing of Active Magnetic Bearings for sCO2 Waste-Heat Recovery Application

The team of Southwest Research Institute (SwRI) and GE Vernova (GE) is executing a project developing conceptual designs of high-temperature active magnetic bearings (AMBs) for sCO2 machinery applications. The goals of the project are to develop conceptual designs for radial and thrust AMBs capable of operating in sCO2 environments up to 1000°F. A waste-heat recovery (WHR) application with hermetic machinery is used as a reference case to apply AMBs. This application was previously investigated to compare hermetic machinery enabled by process-lubricated bearings and high-speed motors/generators with traditional machinery configurations using oil-lubricated bearings, gearboxes, and grid-frequency electric machines. In this paper, AMBs are sized for the WHR application machinery. Load capacity estimates are made using first-principle-derived formulas that consider operation at elevated temperatures. Estimates of linearized AMB system coefficients are also made to aid future controller development. Rotor models are developed that account for AMB rotor geometry and housing space requirements. Rotordynamics studies are performed to identify reasonable target values for closed-loop AMB stiffness and closed-loop AMB damping. These target values will be used in future control studies.

Lipham, Robert↗

From fault-detection to automated fault correction: A field study

A fault detection and diagnostics (FDD) tool, as addressed by this study, is a tool that continuously identifies the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and the application of automated analytics. Although FDD tools can inform operators of building operational faults, currently an action is always required to correct the faults to generate energy savings. Fault auto-correction integrating with commercial FDD technology offerings can close the loop between the passive diagnostics and active control, increase the savings generated by FDD tools, and reduce the reliance on human intervention. This paper presents the field study of seven fault auto-correction algorithms implemented in commercial FDD platforms. Implementation includes software changes in the FDD tools and additional controls hardware or software changes in the BAS that were required to enable the execution of different types of auto-correction algorithms in real buildings. The routines successfully and automatically correct faults and improve the operation of large built-up Heating, Ventilation, and Air Conditioning (HVAC) systems, common in most commercial buildings. The auto-correction algorithms are tested across four buildings and three different building automation systems, following a rigorous procedure to make sure they work properly and do not negatively impact the system and building occupants. Finally, technology benefits, market drivers, and scalability changes are drawn from the implementation effort and test results, to drive future research and industry engagement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adaptive fuzzy dynamic surface control for the chaotic permanent magnet synchronous motor using Nussbaum gain

This paper is concerned with the problem of adaptive fuzzy dynamic surface control (DSC) for the permanent magnet synchronous motor (PMSM) system with chaotic behavior, disturbance and unknown control gain and parameters. Nussbaum gain is adopted to cope with the situation that the control gain is unknown. And the unknown items can be estimated by fuzzy logic system. The proposed controller guarantees that all the signals in the closed-loop system are bounded and the system output eventually converges to a small neighborhood of the desired reference signal. Finally, the numerical simulations indicate that the proposed scheme can suppress the chaos of PMSM and show the effectiveness and robustness of the proposed method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Filtering adaptive output feedback control for multivariable nonlinear systems with mismatched uncertainties and unmodeled dynamics

This article synthesizes a filtering adaptive output feedback controller for multivariable nonlinear systems with mismatched uncertainties and unmodeled dynamics. The multivariable nonlinear systems under consideration have both matched and mismatched uncertainties, which satisfy the semiglobal Lipschitz condition. The unmodeled dynamics are bounded-input bounded-output stable. By adopting an estimation/cancellation strategy, a piecewise constant adaptive law drives the estimation error to zero at every time instant, which yields the adaptive parameters; a disturbance rejection control law is designed to compensate the nonlinear uncertainties within the bandwidth of low-pass filters. The matched uncertainties are cancelled directly by adopting their opposite in the control signal, while a dynamic inversion of the system is required to eliminate the effect of the mismatched uncertainties on the output. A feedforward control law is designed to track a given command. Since the virtual reference system defines the best performance that can be achieved by the closed-loop system, the uniform performance bounds are derived for the states and control signals via comparison. Both numerical and practical examples are provided to illustrate the effectiveness of the proposed filtering adaptive output feedback control architecture, comparisons with the model reference adaptive control demonstrates the superiority of the proposed control method.

filtering adaptive control, mismatched uncertainit↗

Development of a wind turbine model and simulation platform using an acausal approach: Multiphysics modeling, validation, and control

This article presents the development of the Control-oriented, Reconfigurable, and Acausal Floating Turbine Simulator (CRAFTS). CRAFTS has a modular, hierarchical model architecture that enables rapid and accurate simulation of wind turbines. The architecture facilitates the incorporation of model variants, and its system reconfiguration features help simulate multiple design variants. CRAFTS also supports the integration of models developed on a causality-free platform (e.g., Modelica®) with existing causal models. This article focuses on the validation of a land-based wind turbine models against OpenFAST, an industry-standard platform, for several test cases. Closed-loop scenarios are also tested using the standard ROSCO controller and compared against OpenFAST. In addition, a nonlinear controller developed in our prior work is also evaluated. The test cases demonstrate the user-friendly and computationally efficient capabilities of CRAFTS to facilitate control co-design, assist in incorporating multiphysics models, be adaptable to design variants, and allow for rapid simulations to validate models and evaluate controllers.

17 WIND ENERGY↗

Robust decentralized frequency control: A leaky integrator approach

We investigate the robustness of the so-called leaky integral frequency controller for the power network. In particular, using a strict Lyapunov function, we show the closed-loop system is robust in the input-to-state stability sense to measurement noise in the controller. Moreover, an interesting and explicit trade-off between controller performance and robustness is discussed and illustrated using a benchmark study of the 39-bus New England reference network.

Weitenberg, Erik↗

Combined magnetic and kinetic control of advanced tokamak steady state scenarios based on semi-empirical modelling

Our paper shows that semi-empirical data-driven models based on a two-time-scale approximation for the magnetic and kinetic control of advanced tokamak (AT) scenarios can be advantageously identified from simulated rather than real data, and used for control design. The method is applied to the combined control of the safety factor profile, q(x), and normalized pressure parameter, beta(N), using DIII-D parameters and actuators (on-axis co-current neutral beam injection (NBI) power, off-axis co-current NBI power, electron cyclotron current drive power, and ohmic coil). The approximate plasma response model was identified from simulated open-loop data obtained using a rapidly converging plasma transport code, METIS, which includes an MHD equilibrium and current diffusion solver, and combines plasma transport nonlinearity with 0D scaling laws and 1.5D ordinary differential equations. The paper discusses the results of closed-loop METIS simulations, using the near-optimal ARTAEMIS control algorithm (MoreauDet al 2013 Nucl. Fusion 53 063020) for steady stateAT operation. With feedforward plus feedback control, the steady state target q-profile and beta(N) are satisfactorily tracked with a time scale of about 10 s, despite large disturbances applied to the feedforward powers and plasma parameters. We also show the robustness of the control algorithm with respect to disturbances of the H&CD actuators and of plasma parameters such as the H-factor, plasma density and effective charge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Finite Energy and Bounded Attacks on Control System Sensor Signals

Control system networks are increasingly being connected to enterprise level networks. These connections leave critical industrial controls systems vulnerable to cyber-attacks. Most of the effort in protecting these cyber-physical systems (CPS) has been in securing the networks using information security techniques and protection and reliability concerns at the control system level against random hardware and software failures. However, besides these failures the inability of information security techniques to protect against all intrusions means that the control system must be resilient to various signal attacks for which new analysis and detection methods need to be developed. In this paper, sensor signal attacks are analyzed for observer-based controlled systems. The threat surface for sensor signal attacks is subdivided into denial of service, finite energy, and bounded attacks. In particular, the error signals between states of attack free systems and systems subject to these attacks are quantified. Optimal sensor and actuator signal attacks for the finite and infinite horizon linear quadratic (LQ) control in terms of maximizing the corresponding cost functions are computed. The closed-loop system under optimal signal attacks are provided. Illustrative numerical examples are provided together with an application to a power network with distributed LQ controllers.

Cyber-physical↗

Considerations for testing full-scale wind turbine nacelles with hardware-in-the-loop

In this paper, pole placement control techniques are utilized to compensate for variations in the torsional dynamics resulting from the different boundary conditions experienced by a wind turbine nacelle when mounted on a test bench. Simulation case studies are used to understand the baseline torsional characteristics of the nacelle coupled to the test bench versus that coupled to the rotor. It was found that the frequency shifts by up to 200% and 400% for the first and second torsional modes, respectively. The feasibility of utilizing pole placement technique to match the torsional characteristics of the turbine on the test bench is investigated using PI and PID controllers. Here, the performance of the tuned controller is then verified under two test scenarios: Low Voltage Ride Through (LVRT), and a highly dynamic turbulent wind input. It is demonstrated that tuning the test bench speed controller can effectively shift the poles of the closed-loop system to match the desired first and second modes of the full turbine and replicate transient field events on the test bench.

17 WIND ENERGY↗

Robust Stabilization of Inverter-Based Resources Using Virtual Resistance-Based Control

This letter proposes a virtual resistance-based nonlinear control to stabilize and robustify the current layer of inverter-based resources, subject to the grid voltage disturbances, and the grid parameter uncertainties. A class of virtual resistances is proposed and analyzed using concepts from dissipative systems theory. Moreover, specific nonlinear virtual resistance-based controllers are derived, with their corresponding performance analytically bounded. Here, the theoretical and simulation results show that the proposed nonlinear virtual resistance-based controllers significantly reduce the L 2 gain of the closed-loop error system to grid voltage variation and parametric uncertainties. Significant improvements of the transient and steady-state current responses are also demonstrated over linear virtual resistance counterparts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reduced-Order Aggregate Model for Parallel-Connected Single-Phase Inverters

This paper outlines a reduced-order aggregate dynamical model for parallel-connected single-phase grid-connected inverters. For each inverter, we place no restrictions on the converter topology and merely assume that the ac-side switch-averaged voltage can be controlled via pulsewidth modulation. The ac output of each inverter interfaces through an LCL filter to the grid. The closed-loop system contains a phase locked loop for grid synchronization, and real- and reactive-power control are realized with inner and outer PI current- and power-control loops. We derive a necessary and sufficient set of parametric relationships to ensure that a reduced-order aggregated state-space model for an arbitrary number of such paralleled inverters has the same model order and structure as any single inverter. We also present reduced-order models for the settings where the real- and reactive-power setpoints are different and where the inverters have different power ratings. We anticipate the proposed model being useful in analyzing the dynamics of large collections of parallel-connected inverters with minimal computational complexity. The aggregate model is validated against measurements obtained from a multi-inverter experimental setup consisting of three 750-VA paralleled grid-connected inverters, hence establishing robustness of the analytical result to parametric variations seen in practice.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Warrick Conductivity Level Controllers Series 3H

This is my internship poster. In the poster I talk about the level controllers that I wired together and installed to support electrolysis testing systems in efforts to make the systems more efficient and run based on the communication between devices to ensure a closed loop system that can run on its own in a safe and controlled manner. I included pictures of some of the wiring as well as the level sensor devices and relays. I also included pictures of the tanks that will be filled at different heights with deionized water based on where the level sensors are.

08 HYDROGEN↗