Search NASA⌕ Search

SEARCH · Search NASA

Results for “code compliance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Measured Moisture Performance of Sealed and Insulated Attics with Permeable Insulation In California Homes

This study performed detailed thermal and moisture measurements in two homes in Fresno and Clovis, California with sealed attics insulated with glass fiber insulation to determine moisture performance in inland California climates. Data were recorded once every minute for more than a year in each home to allow detailed observation of time-varying moisture and thermal conditions. Moisture measurements were taken at multiple locations in each attic and included wood moisture, surface condensation and surface relative humidity. The results showed that there are strong solar-driven diurnal cycles in attic wood and air moisture content, as well as longer-term seasonal and annual variations. Mold growth was obdserved on the North roof deck in one of the two homes even in this sunny dry climate with attics built in compliance with California building codes that specifically address sealed and insulated attics with vapor-permeable insulation. We investigated moisture stratification in the attic and found that, although there is stratification during sunny daytime hours, this was not when wood moisture content, surface humidity or surface condensation are high. Therefore, other moisture transport mechanisms are acting to increase moisture levels near the roof peak. Finally, our measurements also showed that the attic with the highest measured moisture levels did not have any mold growth, while mold was visually observed in the attic whose measurements indicted little or no concern, indicating that the state-of-the-art in moisture measurement and mold growth prediction in building assemblies may be insufficient.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nevada National Security Site Radiological Control Manual

Please have this STIP assigned, documented, and recorded in OSTI as Report Number DOE/NV/03624--0257 Revision 1 and Author as Radiological Control Managers' Council. This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO). (Activities conducted under the purview of the U.S. Department of Energy, Office of Environmental Management Nevada[(EM Nevada] may require additional approval authorities as described in the EM Nevada Prime Contractor’s implementation plan.) Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations (CFR) Part 835, “Occupational Radiation Protection.” This manual represents policies, guidelines, and best practices for implementing the DOE/NV/03624--0082, “Nevada National Security Site Radiation Protection Program,” (NNSS RPP) according to the requirements of 10 CFR 835.

61 RADIATION PROTECTION AND DOSIMETRY↗

A platform for effective requirements management and collaboration in nuclear compliance and licensing

Buoyed by its promise as a cost effective and low-carbon-footprint source of electricity, the nuclear industry is in the midst of a world-wide renaissance. However, significant challenges, including responding to increased safety and regulatory mandates, making a smooth transition to next-generation reactor technology, and dealing with the adoption of digital instrumentation and control (I and C) systems that rely heavily on software must be effectively addressed to ensure the momentum continues. New technology solutions, such as those developed by IBM's Rational business unit, coupled with well codified processes, policies and best practices leveraged across the nuclear ecosystem's participants have been shown to aid in overcoming these obstacles. This paper will highlight some of the compliance and collaboration challenges facing the extended nuclear ecosystem, describe a potential solution that can aid in addressing the challenges, and present several examples of where the solution has been implemented in the nuclear space. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

When Spreadsheets Become Software - Quality Control Challenges and Approaches - 13360

As part of a preliminary waste acceptance criteria (PWAC) development, several commercial models were employed, including the Hydrologic Evaluation of Landfill Performance model (HELP) [1], the Disposal Unit Source Term - Multiple Species model (DUSTMS) [2], and the Analytical Transient One, Two, and Three-Dimensional model (AT123D) [3]. The results of these models were post-processed in MS Excel spreadsheets to convert the model results to alternate units, compare the groundwater concentrations to the groundwater concentration thresholds, and then to adjust the waste contaminant masses (based on average concentration over the waste volume) as needed in an attempt to achieve groundwater concentrations at the limiting point of assessment that would meet the compliance concentrations while maximizing the potential use of the landfill (i.e., maximizing the volume of projected waste being generated that could be placed in the landfill). During the course of the PWAC calculation development, one of the Microsoft (MS) Excel spreadsheets used to post-process the results of the commercial model packages grew to include more than 575,000 formulas across 18 worksheets. This spreadsheet was used to assess six base scenarios as well as nine uncertainty/sensitivity scenarios. The complexity of the spreadsheet resulted in the need for a rigorous quality control (QC) procedure to verify data entry and confirm the accuracy of formulas. (authors)

54 ENVIRONMENTAL SCIENCES↗

Laying a Foundation for Performance Assessment (PA) Model Development - 19267

Performance Assessment (PA) models are abstractions of real-world conditions. As abstractions, modelers must make a number of decisions regarding model complexity and which features, events, and processes (FEPs) will be represented. To ensure that such decisions are transparent to stakeholders, modelers should document their approach and how this approach influences conceptual model development. This paper describes one such approach. Examples are used to describe an analysis of the potential FEPs. Through the FEPs analysis, all potentially relevant FEPs can be identified. These potentially relevant FEPs are then used to develop a detailed conceptual model known as the Central Scenario, which includes a description of the assessment context, the key features of the site and the closure system, and the expected processes of the system. From this Central Scenario conceptual model, mathematical models can be developed and implemented within modeling software and used to demonstrate compliance to PA performance objectives. FEPs which are beyond the scope of the Central Scenario are identified and used as the basis for developing alternative conceptual models (ACMs) or sensitivity analyses. Once these models and modeling cases are defined, the necessary inputs can be identified and defined. (author)

97 MATHEMATICS AND COMPUTING↗

Refreshing Waste Tracking Software for the 2020's - 20059

The Waste Compliance and Tracking System (WCATS) is a software application designed to manage waste operations from cradle to grave. The system provides the support needed for characterization, generation, processing, and shipment of all waste generated or stored at Los Alamos National Laboratory (LANL). Waste is tracked with task records for containers in real-time via both desktop and mobile device applications. The software allows application administrators to configure sites with appropriate limits for Pu-239 equivalent Curies (PE-Ci), fissile gram equivalents (FGEs), volume limits, as well as custom limits for site-specific technical safety requirements (TSRs). WCATS was developed based on a need at Los Alamos National Laboratory for a modern, customizable waste tracking system that could support many different waste types. The application is built using Oracle{sup R} database and Oracle{sup R} ADF Swing application framework. The technologies and software frameworks selected for the system were finalized in 2006. Although Oracle{sup R} Database has proven to be robust, the user interface and application framework interface with the database have been deprecated and need to be replaced. The technologies selected for modernization follow the open-source model, which allows the WCATS team to more easily recruit developers, improve the speed of development, and ease the deployment and adoption of the system. The tools that support the re-engineering effort are Vue.js{sup R}, a JavaScript{sup R} framework, and Spring Boot{sup R}, an API (application programming interface) development tool written in Java{sup R}. An API allows for simplified communication from the database to the user interface of the application. In addition, legacy Crystal Reports{sup R} will be replaced with reports developed with the open source Pentaho{sup TM}f Report Designer community edition. Because the application uses HTML and JavaScript{sup R}, it builds upon tools that have been used for many years in web development. These tools have large community support and their proven track record will ensure that enhancements to WCATS can continue for years to come. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Synthesis Report on the Implementation of Building Energy Codes in China

China is the new leader in the global construction market, with $1,000 billion invested into new construction projects in 2010. With its already significant building stock, high construction rate of new buildings, and strong governmental commitment to improving building energy efficiency, China is positioned to have great influence on global building energy use in the years to come. Building energy efficiency was first addressed in the mid 1980s, after China developed its new political doctrine of “Socialism with Chinese Characteristics” in the late 1970s and launched its unprecedented economic reform. Since then, the development of building energy efficiency policy has gone through into five stages: (1) early research and preparation, (2) pilots and demonstrations, (3) institution development and goal setting, (4) goal implementation, and (5) development and implementation of an array of policies and projects promoting building energy efficiency (Chapter 2). Building energy standards and codes are one important policy instrument targeted by Chinese government. Over three decades of governmental efforts, China has successfully established a comprehensive system of building energy standards and codes. The system covers the life cycle process of a building project, from design, construction and acceptance, inspection, evaluation, modification, products and selection of building materials to building operation. This project, the DOS project, is focused on the implementation of four building energy codes: three of which are design standards (two for residential buildings and one for public/commercial) and one is a code of construction and acceptance (Chapter 3). The current implementation status of building energy codes in China is a tale of two extremes: while there is no implementation in rural areas, the implementation in urban areas is very encouraging. The compliance rates of building energy codes in both the design and construction stages in the inspected large- and mid-size cities were a stunning 98% and 90%, respectively, in 2009. The impressive compliance rates come from establishing an implementation system that consists of a complete loop of the monitoring and inspection subsystem: building design companies, building inspection companies, construction companies, construction inspection companies, testing companies and labs (all of them are third parties), and semi-governmental quality supervision stations to oversee the implementation process (Sections 4.1 and 4.2). Besides the unique, active engagement of third parties, China’s implementation practices are also equipped with strict penalties for violations (Section 4.3), annual inspection for building energy efficiency (Section 4.4), and comprehensive national title exams for key stakeholders (Section 4.5.1). So, what are the challenges faced by key stakeholders when they implement building energy codes? Through stakeholder meetings, focus group meetings, training seminars, onsite construction visits, and personal communications, the project team concluded that training and information dissemination is the ignored, under-invested, and weak component in China’s current implementation practices (Section 6.1).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Using the CAP88 Plume Model & Dose Assessment Code for the FTWC Project

The Environmental Protection & Compliance Division (EPC) uses the Clean Air Act Assessment Package – 1988 (CAP88) plume model and dose assessment code to evaluate measured emissions or projected emissions of airborne radionuclides from Los Alamos National Laboratory (LANL) facilities. This software package will use facility data (e.g., stack height and exit velocity), emissions parameters (chemical form and quantity), and environmental data (wind speed and direction) to predict downwind concentrations of radioactive material and subsequent dose to a member of the public at that location. The United States Environmental Protection Agency (EPA) has approved CAP88 for use in demonstrating compliance with the Radionuclide NESHAP2, that portion of the Clean Air Act addressing emissions of airborne radioactive material from Department of Energy facilities. EPC Division has two procedures which discuss the use of CAP88.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Marriage of Residential Energy Codes and Rating Systems: Conflict Resolution or Just Conflict?

After three decades of coexistence at a distance, model residential energy codes and residential energy rating systems have come together in the 2015 International Energy Conservation Code. At the October, 2013, International Code Council’s Public Comment Hearing, a new compliance path based on an Energy Rating Index was added to the IECC. Although not specifically named in the code, RESNET’s HERS rating system is the likely candidate Index for most jurisdictions. While HERS has been a mainstay in various beyond-code programs for many years, its direct incorporation into the most popular model energy code raises questions about the equivalence of a HERS-based compliance path and the traditional IECC performance compliance path, especially because the two approaches use different efficiency metrics, are governed by different simulation rules, and have different scopes with regard to energy impacting house features. A detailed simulation analysis of more than 15,000 house configurations reveals a very large range of HERS Index values that achieve equivalence with the IECC’s performance path. This paper summarizes the results of that analysis and evaluates those results against the specific Energy Rating Index values required by the 2015 IECC. Based on the home characteristics most likely to result in disparities between HERS-based compliance and performance path compliance, potential impacts on the compliance process, state and local adoption of the new code, energy efficiency in the next generation of homes subject to this new code, and future evolution of model code formats are discussed.

Residential, Energy, Rating systems, HERS, 2015 IE↗

USACE FUSRAP Maywood Team Develops a Mechanism to Evaluate Residual Radon Exposure Potential at Vicinity Properties Where Remediation of Accessible Contamination has been Completed

The Maywood FUSRAP Team is obligated, under its approved remedy selection decision document, to demonstrate substantive compliance with New Jersey Administrative Code 7:28- 12(a)2, establishing an indoor limit of three Pico-Curies per liter above background for radon-222 (Rn-222). The Maywood Team explores various avenues for dealing with the radon issue and provides an alternative for demonstrating substantive compliance with the radon remediation standard by answering the question: 'In certain conservative situations, can compliance with the radon standard be demonstrated without performing monitoring?' While monitoring may be the most definitive method for demonstrating compliance, a logical argument can be made that when radiological remediation removes the potential source for Rn-222 above background, monitoring is unnecessary. This position is defended through the use of historical physical radon measurements which illustrate that indoor radon was not a pre-remediation problem, and post-remediation soil sampling data which demonstrate that the source of the potentially elevated Rn- 222 levels have been successfully mitigated. Monitoring recommendations are made for situations where insufficient data exists to make definitive determinations or when un-remediated sources affecting habitable structures remain on a given property. Additional information regarding recommended techniques and references for effective monitoring of indoor radon are included in this paper. This paper may benefit teams that have similar regulatory commitments and/or have need to make assessments of radon exposure potential based upon historical monitoring data and available soils concentration data. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Energy Cost Impact of Non-Residential Energy Code Requirements

The 2012 International Energy Conservation Code contains 396 separate requirements applicable to non-residential buildings; however, there is no systematic analysis of the energy cost impact of each requirement. Consequently, limited code department budgets for plan review, inspection, and training cannot be focused on the most impactful items. An inventory and ranking of code requirements based on their potential energy cost impact is under development. The initial phase focuses on office buildings with simple HVAC systems in climate zone 4C. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance. A preliminary estimate of the probability of occurrence of each level of non-compliance was combined with the estimated lost savings for each level to rank the requirements according to expected savings impact. The methodology to develop and refine further energy cost impacts, specific to building type, system type, and climate location is demonstrated. As results are developed, an innovative alternative method for compliance verification can focus efforts so only the most impactful requirements from an energy cost perspective are verified for every building and a subset of the less impactful requirements are verified on a random basis across a building population. The results can be further applied in prioritizing training material development and specific areas of building official training.

code compliance↗

An international survey of building energy codes and their implementation

Buildings are key to low-carbon development everywhere, and many countries have introduced building energy codes to improve energy efficiency in buildings. Yet, building energy codes can only deliver results when the codes are implemented. For this reason, studies of building energy codes need to consider implementation of building energy codes in a consistent and comprehensive way. This research identifies elements and practices in implementing building energy codes, covering codes in 22 countries that account for 70% of global energy demand from buildings. Access to benefits of building energy codes depends on comprehensive coverage of buildings by type, age, size, and geographic location; an implementation framework that involves a certified agency to inspect construction at critical stages; and independently tested, rated, and labeled building energy materials. Training and supporting tools are another element of successful code implementation, and their role is growing in importance, given the increasing flexibility and complexity of building energy codes. Some countries have also introduced compliance evaluation and compliance checking protocols to improve implementation. This article provides examples of practices that countries have adopted to assist with implementation of building energy codes.

54 ENVIRONMENTAL SCIENCES↗

EUI Benchmarks for Net-Zero Energy Buildings in India

In our study we present EUI benchmarks for NZEBs for six building types across residential and non-residential typologies and for India's five climate zones. This approach is similar to the simulation-based benchmarks used by the B3 program in Minnesota, the Cal-Arch methodology in California, and the US Solar Decathlon approach, which combine simulations with actual building data. Of the six building types we explore one in detail with a range of operation scenarios, specifically narrowing down the EUI benchmarks for mixed-mode building operation and for variable temperature set-points as prescribed in the National Building Code of India.The contribution of this work is to provide rigorous end-use level EUI benchmarks for six building types, and to describe a method for simulation-based EUI benchmarks for mixed-mode operation with variable setpoints to highlight the difference between the standard approach used for the five building types and the On-Site Construction Worker Housing which additionally has the mixed-mode variable setpoint approach.On-Site Construction Worker Housings are typically poorly constructed temporary structures, without adequate thermal comfort, It is critical to provide adequate thermal comfort to protect people from the warming effects of climate change, and to discover super efficient and cost-effective ways to do so.The methodology used for the On-Site Construction Worker Housing (CWH) results in an 80% acceptability according to the India Model for Adaptive Comfort in the National Building Code of India. EUIs of all six buildings are 60% lower than the minimum compliance with India's Energy Conservation Building Codes, providing benchmarks for efficiency levels. The end-use level EUI benchmarks are now provided to over 1800 Solar Decathlon India participants so that they can compare the performance of their NZEB designs.In particular, the CWH results provide an insight into the importance of the mixed-mode operation with variable temperature set-points. The results from the simulation study show that for an NZEB target, the EUI with standard thermal comfort model and without mixed operation is 58.26 kWh/m2*year, while that with the variable set-points of the adaptive model with mixed mode operation is 24.23 kWh/m2*year. This is a 58% reduction in EUI. Given that many building types including residential, and non-residential operate in mixed mode, it is important to take this work further to develop mixed-mode operation NZEB benchmarks so that the carbon intensity of these buildings could be lower than the standard thermal comfort model approach.

benchmarking↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Regulatory Framework for Salt Waste Disposal and Tank Closure at the Savannah River Site - 13663

The end of the Cold War has left a legacy of approximately 37 million gallons of radioactive waste in the aging waste tanks at the Department of Energy's Savannah River Site (SRS). A robust program is in place to remove waste from these tanks, treat the waste to separate into a relatively small volume of high-level waste and a large volume of low-level waste, and to actively dispose of the low-level waste on-site and close the waste tanks and associated ancillary structures. To support performance-based, risk-informed decision making and to ensure compliance with all regulatory requirements, the U.S. Department of Energy (DOE) and its current and past contractors have worked closely with the South Carolina Department of Health and Environmental Control (SCDHEC), the U.S. Environmental Protection Agency (EPA) and the Nuclear Regulatory Commission (NRC) to develop and implement a framework for on-site low-level waste disposal and closure of the SRS waste tanks. The Atomic Energy Act of 1954, as amended, provides DOE the authority to manage defense-related radioactive waste. DOE Order 435.1 and its associated manual and guidance documents detail this radioactive waste management process. The DOE also has a requirement to consult with the NRC in determining that waste that formerly was classified as high-level waste can be safely managed as either low-level waste or transuranic waste. Once DOE makes a determination, NRC then has a responsibility to monitor DOE's actions in coordination with SCDHEC to ensure compliance with the Title 10 Code of Federal Regulations Part 61 (10CFR61), Subpart C performance objectives. The management of hazardous waste substances or components at SRS is regulated by SCDHEC and the EPA. The foundation for the interactions between DOE, SCDHEC and EPA is the SRS Federal Facility Agreement (FFA). Managing this array of requirements and successfully interacting with regulators, consultants and stakeholders is a challenging task but ensures thorough and thoughtful processes for disposing of the SRS low-level waste and the closure of the tank farm facilities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Non-Destructive Assay Systems and Special Instrumentation Requirements for Spent Nuclear Fuel Recycling Facilities

The safe and efficient operation of the next generation of Spent Nuclear Fuel (SNF) recycling / reprocessing facilities is dependent upon the availability of high performance real time Non- Destructive Assay (NDA) systems at key in-line points. A diverse variety of such special instrument systems have been developed and commissioned at reprocessing plants worldwide over the past fifty years.. The measurement purpose, technique and plant performance for selected key systems have been reviewed. Obsolescence issues and areas for development are identified in the context of the measurements needs of future recycling facilities and their associated waste treatment plants. Areas of concern include (i) Materials Accountancy and Safeguards, (ii) Head End process control and feed envelope verification, (iii) Real-time monitoring at the Product Finishing Stages, (iv) Criticality safety and (v) Radioactive waste characterization. Common characteristics of the traditional NDA systems in historical recycling facilities are (i) In-house development of bespoke instruments resulting in equipment that if often unique to a given facility and generally not commercially available, (ii) Use of 'novel' techniques - not widely deployed in other applications, (iii) Design features that are tailored to the specific plant requirements of the facility operator, (iv) Systems and software implementation that was not always carried out to modern industry standards and (v) A tendency to be overly complex - refined by on-plant operational usage and experience. Although these systems were 'validated in use' and are generally fit for purpose, there are a number of potential problems in transferring technology that was developed ten or more years ago to the new build SNF recycling facilities of the future. These issues include (i) Obsolescence of components - particularly with respect to computer hardware and data acquisition electronics, (ii) Availability of Intellectual Property and design drawings and documentation (iii) Lack of compatibility with modern computers, software, data transfer networks, digital protocols and electrical code standards, (iv) Non-compliance with current and future mandatory standards and regulations for nuclear facilities (v) Design focused on measurement and control points that may be specific to the facility process (vi) Lack of utilization of recent technological advances where better performing, less complex and more cost-effective options are now available. Key radiometric measurement drivers and control points for future recycling facilities have been determined and a review of the adequacy of existing instrumentation has been performed. Areas where recent technology improvements may be more effectively deployed and future technology development may be appropriate are identified. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Applicability of Public Dose Limits to Individuals on the Nevada National Security Site

Historically all persons working on the Nevada National Security Site (NNSS) were considered subject to worker dose limits when calculations of potential dose from the air pathway were conducted to demonstrate compliance with Title 42 United States Code (USC) Chapter 85, “The Clean Air Act,” and Title 40 Code of Federal Regulations (CFR) Part 61, Subpart H, “National Emission Standards for Hazardous Air Pollutants (NESHAP).” Calculations were also conducted for the all-pathways potential dose to demonstrate compliance with U.S. Department of Energy (DOE) Order DOE O 458.1 Chg. 3, “Radiation Protection of the Public and the Environment.” The need to evaluate environmental air sampling locations and past regulator questions about the existence of persons potentially subject to public dose limits being on the NNSS drove this assessment (letter from EPA [U.S. Environmental Protection Agency] Region 9 to DOE/Nevada Operations Office, dated September 3, 1999). This assessment also supports determining those persons subject to public dose limits from the all pathways perspective. A person that is a member of the public is subject to public dose limits.

61 RADIATION PROTECTION AND DOSIMETRY↗

Codes and Standards Requirements for Deployment of Emerging Fuel Cell Technologies

The objective of this NREL report is to provide information on codes and standards (of two emerging hydrogen power fuel cell technology markets; forklift trucks and backup power units), that would ease the implementation of emerging fuel cell technologies. This information should help project developers, project engineers, code officials and other interested parties in developing and reviewingpermit applications for regulatory compliance.

08 HYDROGEN↗