Search NASA⌕ Search

SEARCH · Search NASA

Results for “collimator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Current Status of Developing Ultrafast Mega-electron-volt Electron Microsope

Recent studies of ultrafast electron microscopy (UEM) techniques show the use of short bunches of relativistic electrons is promising for the development of a new instrument for imaging various materials. Compared to conventional electron microscopes, the main advantage of UEMs with the electron energy of a few MeV is the possibility to study thick samples. We will discuss the progress of UEM design to date, the principal challenges on the way to a high resolution, and possible methods for their mitigation including the design of low-aberration magnetic optics, RF and mechanical subsystems with high stability, and precise collimation of electrons scattered in the samples.

43 PARTICLE ACCELERATORS↗

Specification of EBR-II Gamma Scan Data from the Precision Gamma Scanner

The gamma scan data stored in the FIPD was originally measured using the Precision Gamma Scanner (PGS) at the Hot Fuel Examination Facility (HFEF) at Idaho National Laboratory (INL). This system was originally manufactured in 1971 (when the facilities, now at INL, were operated by Argonne National Laboratory) and was upgraded on several occasions. It consists of a germanium gamma ray detector (the exact nature of which changed over time as technology improved), a variable-slit collimator that blocks the view of gamma emissions from all but the selected area of the target, and a computer-controlled system for translating a sample past the slit and logging the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling LANSCE Line D and RI Beamlines in Elegant and Impact-T

This technical report describes models in Elegant and Impact-T of two LANSCE high-energy beamlines: LineD and Ring Injection. These two beamlines transport the 800 MeV H- beam from the exit of the 805 MHz Linac to the entrance of the PSR. Computer models of all LANSCE high-energy beamlines exist in Transport but include a limited model of the space charge forces. A motivation for using Elegant as an optional beam dynamics code is that the existing model of the PSR is in Elegant, therefore enabling the modeling of the full beam injection scheme. Also, Elegant is a modern code being used by a large accelerator physics community which makes the calculation results more reliable. The drawback is that Elegant has also a limited space charge force model. Therefore, we have opted to include the Particle-In-Cell (PIC) code Impact-T as an alternate beam dynamics code to verify the Elegant calculations. We will use the new Line D and RI models to study beam halo in the transport leading into the PSR, and to evaluate collimation schemes as part of the PSR upgrade. The new models can also be readily used in support of other LANSCE activities.

43 PARTICLE ACCELERATORS↗

Development of Transmission Measurements Capability at VISION Spectrometer [Slides]

This presentation covers the development of transmission measurements capability at VISION Spectrometer. Main takeaways include that INS and transmission measurements are and should be the most significant part of TSL validation, as they are the fundamental quantities used by Monte Carlo neutronics codes. Additionally, the development of transmission capability at VISION instrument has commenced. Promising first results have been obtained with a big impact by the use of the collimators. Finally, Areas of improvement have been identified and new measurements are planned for June.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Co-op Presentation Fall 2023

This presentation is an overview of the four projects I worked on during my first co-op term. The first project was a 3D-printed support for a horn that was being X-rayed. My second project was a website that compiled all data available on outgassing and created a comprehensive database. My third project was creating a cart for a PIP-II absorber that needs to be transported down the beamline using NX. My fourth and final project was testing a prototype of a collimator.

43 PARTICLE ACCELERATORS↗

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor [Poster]

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed. The wirescanner system in the ATR canal is utilized after every reactor cycle by the ATR Radiation Measurements Laboratory (RML) to assess the activation of cobalt and nickel dosimeter wires during the cycle. These wires become activated through exposure to thermal and fast neutrons respectively during the irradiation cycle and are highly radioactive upon shutdown. It is for this reason that the wirescanner is used in the ATR canal rather than transporting the dosimeters to another facility. A scoping study was performed to develop a base-line design to ensure that existing capabilities could be replaced with a new system. The new hardware will enable automated measuring of several flux monitor holders without necessitating the removal of the flux wires. In this way, flux wire measurements will be performed with minimal dose to the technicians and will not be limited by canal operations as is presently the case. The new control and acquisition software will be based on commercially available and supported systems that have a wide user-base to provide long-term stability. An electronically cooled HPGe detector will be used to provide high-resolution gamma-ray measurements, an improvement from the low-resolution sodium-iodide detector that is presently deployed. The electronic cooler eliminates the need for liquid nitrogen to cool the detector head. A new collimator has been designed to house the new detector and allow for sufficient counting rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimization Studies of Radiation Shielding for PIP-II Project at Fermilab

The Proton Improvement Plan-II (PIP-II) at Fermilab represents a significant advancement in the quest to answer some of the most profound questions about our universe using the world's most intense high-energy neutrino beam. The project requires the construction of a new addition to the Fermilab accelerator complex – an 800-MeV high-intensity superconducting linear accelerator. Ensuring the safety and regulatory compliance of this ambitious project is paramount, necessitating thorough dose rate assessments under both normal operational and accidental scenarios to align with the Fermilab Radiological Control Manual (FRCM) standards. Our approach included a shielding optimization used for the simulations with the Monte Carlo code MARS [1,2,3] to incorporate new magnet and collimator designs, essential for reflecting the current state of PIP-II infrastructure. The implementation of high-resolution detector planes, despite their computational demands, enabled us to gather detailed radiation field data crucial for optimizing shielding configurations. To overcome the significant computational demands, we developed a branching code that drastically reduced simulation runtimes while maintaining statistical integrity. This was achieved through geometry splitting and the application of Russian Roulette techniques, tailored to prioritize regions of interest based on predefined importances and weight limits.

43 PARTICLE ACCELERATORS↗

Search For Low-Mass Quark-Antiquark Resonances Produced With an Initial State Photon at 13 TeV Using the CMS Detector

We present a search for low-mass narrow qq̅ resonances. This search uses data from LHC pp collisions at a center of mass of 13 TeV in Run 2, and corresponds to an integrated luminosity of 137 fb^{-1}, currently using 10\% of data. Utilizing full Run 2 data allows the use of a lower photon pT threshold trigger than a previous analysis performed with only 2016 data, allowing this analysis to be more sensitive to resonances in the low mass region. We require an initial state photon recoiling against the narrow resonance, leading to the resonance having a high transverse momentum. The high pT decay products of the resonance collimate and are reconstructed as a single large jet with an internal two-pronged substructure. A two-pronged dijet score based on the ParticleNet tagger is used to select jets with two-pronged substructure. The background is estimated via a data-driven method using a transfer factor between the distributions which fail and pass the two-pronged substructure requirement. The new physics signal is searched for as a narrow peak excess above the Standard Model backgrounds in the jet mass spectrum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rapid Demonstration of Bremsstrahlung Diode Optimization

Optimization of the radiation pattern from a Bremsstrahlung target for a given application is possible by controlling the electron beam that impacts the high-atomic-number target. In this work, the electron beam is generated by a 13MV vacuum diode that terminates a coaxial magnetically insulted transmission line (MITL) on the HERMES-III machine at Sandia National Labs. Work by Sanford introduced a geometry for vacuum diodes that can control the flow within bounds. The "indented anode", as coined by Sanford, can straighten out the electron beam in a high-current diode that would otherwise be prone to beam pinching. A straighter beam will produce a more forwardly directed radiation pattern while a pinching electron beam will yield a focal point or hot spot on axis and a more diffuse radiation pattern. Either one of these may be desirable depending on the application. This work serves as a first attempt to optimize the radiation pattern in the former sense of collimating the radiation pattern given a limited parameter space. The optimization is attempted first using electromagnetic particle-in-cell simulations in the EMPIRE code suite. The setup of the models used in EMPIRE is discussed along with some basic theory behind some of the models used in the simulations such as anode heating and secondary ions. Theoretical work performed by Allen Garner and his students at Purdue is included here, which concerns the impact of collisions in these vacuum diodes. The EMPIRE simulations consider both an aggressive and a conservative design. The aggressive design is inherently riskier while the conservative design is chosen as something that, while still a risk, is more likely to perform as expected. The ultimate goal of this work was to validate the EMPIRE code results with experimental data. While the experiment that tested the diode designs proposed by the simulation results fell outside of the fiscal boundaries of this project (and for that reason the results of which are not included in this report), the hardware for the experiment was designed and drafted within those same fiscal boundaries, and is thus included in this report. However, there was yet another experiment performed in this project that tested a key feature of the diode: the hemispherical cathode. Those results are documented here as well, which show that the cathode tip is an important aspect to controlling the diode flow. A short series of simulations on this diode were also performed after the experiment in order to gain a better understanding of the effect of ions. on the flow pattern and faceplate dose profile.

43 PARTICLE ACCELERATORS↗

Accelerator Neutrinos

Neutrino beams generated by particle accelerators are essential for probing fundamental physics. This presentation will examine the creation of high-intensity, well-collimated neutrino beams, crucial for long-baseline experiments like DUNE and NOvA. These experiments are pushing proton beam power to multi-MW levels and utilizing large-scale detectors to overcome the challenge of limited event statistics. At LBNF, the DUNE experiment will rigorously test the three-neutrino flavor model and explore CP violation by analyzing oscillation signatures in high-intensity νμ(νμˉ)νμ​(νμ​ˉ​) to νe(νeˉ)νe​(νe​ˉ​) beams. We'll explore the technical complexities of beamline components, the drive towards higher beam powers, and the strategies for measuring and managing neutrino flux. The presentation will also cover advancements in neutrino beam instrumentation and efforts to enhance beam precision, which are key to achieving the next generation of multi-megawatt accelerator facilities. By reviewing past achievements and future prospects, this talk aims to provide a clear overview of the current state and future potential of neutrino beam technology.

Ganguly, Sudeshna↗

Interpreting and Accelerating Transformers for Jet Tagging

Attention-based transformers are ubiquitous in machine learning applications from natural language processing to computer vision. In high energy physics, one central application is to classify collimated particle showers in colliders based on the particle of origin, known as jet tagging. In this work, we study the interpretatbility and prospects for acceleration of Particle Transformer (ParT), a state-of-the-art model, leverages particle-level attention to improve jet-tagging performance. We analyzing ParT's attention maps and particle-pair correlations in the eta-phi plane, revealing intriguing features, such as a binary attention pattern that identifies critical substructure in jets. These insights enhance our understanding of the model's internal workings and learning process and hint at ways to improve its efficiency. Along these lines, we also explore low-rank attention, attention alternatives, and dynamic quantization to accelerate transformers for jet tagging. With quantization, we achieve a 50% reduction in model size and a 10% increase in inference speed without compromising accuracy. These combined efforts enhance both the performance and the interpretability of transformers in high-energy physics, opening avenues for more efficient and physics-driven model designs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Migration of 60 Co, 133 Ba, 137 Cs, and 152 Eu from cementitious wasteforms in field lysimeter experiments

Safe and effective storage of radioactive waste is essential to protect environmental health. Due to the potential for accidental releases and the severity of the associated risks, it is imperative to further understand radionuclide transport should an accident occur. This work analyzed the vadose zone migration of radionuclides from cementitious wasteforms at the Savannah River Site after ten years. The observed radionuclides are prominent constituents of radioactive waste or analogs for other groups or series of radionuclides. Lysimeters were first analyzed in 2016 using a collimated high-purity germanium gamma-ray spectrometer to non-destructively measure the concentration of each radionuclide in the sediment column as a function of depth. Following these measurements, the lysimeters were redeployed in the field for another 4 years. All radionuclides in all lysimeters were observed to transport further during the redeployment period; however, the extent of migration varied with the material used for introduction. Except for 137 Cs, migration through the sediment control system increased with decreasing ionic potential (ionic charge/radius); migration order: 152 Eu< 137 Cs< 60 Co< 133 Ba. Overall, the cementitious wasteforms were observed to decrease radionuclide migration extent relative to the filter paper. In both cementitious wasteforms, the migration extent increased in the order 152 Eu< 133 Ba< 60 Co< 137 Cs. However, less migration was measured when the radionuclides were incorporated into a reducing grout wasteform. The novelty of this paper is the demonstration of a technique capable of creating non-destructive measurements over decade time scales. Ultimately, this work provides insight into the long-term migration of alkali, alkali earth, divalent transition metal, and trivalent actinide element isotopes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extreme Longitudinal Compression of Optimized Beams for MEV Ultrafast Electron Diffraction (Final Technical Report)

We worked out the design of a high repetition rate MeV energy ultrafast electron diffraction instrument based on the existing Cornell photoinjector, which can readily be applied to the presented findings. This example is a blueprint of other similarly arranged UED setups. Using particle tracking simulations in conjunction with multiobjective genetic algorithm optimization, we explored the smallest bunch lengths, emittance, and probe spot sizes achievable. As two limits, we defined stroboscopic conditions (with single electrons per pulse) and operation with 10 5 electrons per bunch which may be suitable for single-shot diffraction images. In the stroboscopic case, the flexibility provided by the many cavity bunching and acceleration allows for longitudinal phase space linearization without a higher harmonic field, providing sub-fs bunch lengths at the sample. Given low emittance photoemission conditions, these small bunch lengths can be maintained with probe transverse sizes at the single micron (1 μm) scale and below. In the case of 10 5 electrons per pulse, we simulated state-of-the-art 5D brightness conditions: rms bunch lengths of 10 fs with 3-nm normalized emittances, while permitting repetition rates as high as 1.3 GHz. We showed that in conjunction with collimating apertures, a novel focusing scheme achieves very high-quality emittance compensation for the central core of the beam composing 40% of particles, for a resulting beam size of 5 μm (rms). Finally, to aid in the design of new SRF-based ultrafast electron diffraction machines, we simulated the trade-off between the number of cavities used and achievable bunch length and emittance. In the longitudinal dimension, we made use of the fact that MeV UED requires much lower energy than the 15-MeV maxi mum energy of Cornell’s CBETA injector, and we may therefore use several of the SRF cavities for bunch length compression. In practice, we used a genetic optimization algorithm to choose the phases and amplitudes of the cavities appropriately for optimal bunching. In the zero space charge case, we found that bunching and acceleration are distributed across the six cavities in a way that produces a linearizing effect. And we showed that the ultimate bunch length can be limited by time-of-flight differences arising from transverse size and transverse momentum spread. The space charge code developed and used for this development is now permanent part of the Bmad accelerator simulation code and has already contributed to other developments, e.g., for the EIC electron cooler design.

43 PARTICLE ACCELERATORS↗

Optimization Studies of Radiation Shielding for PIP-II Project at Fermilab

The Proton Improvement Plan-II (PIP-II) at Fermilab represents a significant advancement in the quest to answer some of the most profound questions about our universe using the world's most intense high-energy neutrino beam. The project requires the construction of a new addition to the Fermilab accelerator complex – an 800-MeV high-intensity superconducting linear accelerator. Ensuring the safety and regulatory compliance of this ambitious project is paramount, necessitating thorough dose rate assessments under both normal operational and accidental scenarios to align with the Fermilab Radiological Control Manual (FRCM) standards. Our approach included a shielding optimization used for the simulations with the Monte Carlo code MARS [1,2,3] to incorporate new magnet and collimator designs, essential for reflecting the current state of PIP-II infrastructure. The implementation of high-resolution detector planes, despite their computational demands, enabled us to gather detailed radiation field data crucial for optimizing shielding configurations. To overcome the significant computational demands, we developed a branching code that drastically reduced simulation runtimes while maintaining statistical integrity. This was achieved through geometry splitting and the application of Russian Roulette techniques, tailored to prioritize regions of interest based on predefined importances and weight limits.

Makovec, Alajos↗

LLRF System for the Fermilab Mu2e Project – AC Dipole Extinction

The Mu2e experiment measures the conversion rate of muons into electrons. The experiments requires 53 MHz batches of 8 GeV protons to be re-bunched into 150 ns, 2.5 MHz pulses for extraction to a single RF cavity running at 2.36 MHz. To meet stringent limits on the amount of beam between pulses, an Extinction System is used comprising of 2 AC dipole magnets (4.4MHz, 296Khz) and a collimator.

Guran, M. [Fermilab] (ORCID:0009000235538559)↗

Neutrino Physics at a Muon Collider, and the Neutrino Kaleidoscope

Muon accelerators, a potential technology for enabling O(10 TeV) parton center of mass energy collisions, would also source an intense, collimated beam of neutrinos at TeV energies. There is currently a renewed effort to understand the possible scientific reach of such a neutrino beam in the context of neutrino physics. One possibility is the “Neutrino Kaleidoscope”: the pairing of a muon accelerator neutrino flux with a neutrino telescope detector. In particular, such a pairing would enable searches for non-standard oscillations of the beam neutrinos as they traverse the earth between source and detector. These non-standard neutrino oscillations could be sourced by Lorentz invariance violation, which a neutrino kaleidoscope could probe up to the quantum gravity-motivated Planck scale. Such a search would also have a reach on sterile neutrinos orders of magnitude beyond existing terrestrial limits. In this talk, I will introduce some of the exciting measurements being proposed with the neutrinos from a muon accelerator and then go into detail on the Neutrino Kaleidoscope concept (arxiv:2508.09249).

Putnam, Gray [Fermilab]↗

Expansion of the Fuel Motion Monitoring System

The Idaho National Laboratory (INL) Transient Reactor Test Facility (TREAT) Fuel Motion Monitoring System (FMMS) is a diagnostic tool used to visualize the movement and location of fuel within the nuclear reactor during transient experiments. TREAT is designed to test the behavior of nuclear fuel under accident conditions, such as a rapid power increase. The TREAT FMMS, also referred to as the “hodoscope” because of the system’s massive steel collimator component, is located on the North beam port of the reactor. While the FMMS system is capable of incorporating a total of 360 sensors, initial refurbishment efforts resulted in a array of 96 fast neutron detectors. This initial array was configured to provide a narrow (2 channels) full-length view of experiment vessels with an extended 4-channel–wide region in the center of the array capable of providing a full view of all initially planned experiments. Planning and efforts to expand the FMMS array began immediately following the restart of TREAT. An additional 96 detectors were evaluated, characterized, and prepared for installation at TREAT during the summer of 2018. Unfortunately, funding reductions forced the project towards a 5-year hiatus. In October of 2023 funding from the Department of Energy’s Nuclear Science User Facilities enabled the expansion to recommence. This report serves to document the activities performed to expand the FMMS detector array to 192 channels in order to provide a broader view of the larger and more sophisticated test capsules currently planned for future irradiation in the TREAT reactor. This expansion also included doubling the data acquisition capability, addressing the new heat load on the system, and synchronizing the time for all digital components.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Power Targetry R&D Roadmap for High Energy Physics

Designing a reliable target is already a challenge for MW-class facilities today and has led several major accelerator facilities to operate at lower power due to target concerns. With present plans to increase beam power for next-generation accelerator facilities in the next decade, timely R&D in support of robust high-power targets is critical to secure the full physics benefits of ambitious accelerator power upgrades. The next generation of high-power targets and beam-intercepting devices (beam dumps, absorbers, collimators ) will have more complex geometries, novel materials, and new concepts that allow for use of improved high-heat-flux cooling methods. Advanced numerical simulations need to be developed to support design of reliable high-power beam targets. In parallel, development of radiation-hardened beam instrumentation is needed. Irradiation methods for high-power targets must be further developed, and new irradiation facilities are needed since only a few facilities worldwide offer beams suitable for target testing. A comprehensive R&D program must be implemented to address the many complex challenges faced by multi-MW beam intercepting devices.

Pellemoine, Frederique [Fermilab]↗