Search for light neutral particles decaying promptly into collimated pairs of electrons or muons in pp collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

A search for a dark photon, a new light neutral particle, which decays promptly into collimated pairs of electrons or muons is presented. The search targets dark photons resulting from the exotic decay of the Standard Model Higgs boson, assuming its production via the dominant gluon-gluon fusion mode. The analysis is based on 140 fb -1 of data collected with the ATLAS detector at the Large Hadron Collider from proton-proton collisions at a center-of-mass energy of 13 TeV. Events with collimated pairs of electrons or muons are analysed and background contributions are estimated using data-driven techniques. No significant excess in the data above the Standard Model background is observed. Upper limits are set at 95% confidence level on the branching ratio of the Higgs boson decay into dark photons between 0.001% and 5%, depending on the assumed dark photon mass and signal model.

Aad, G. [Aix-Marseille Université] (ORCID:00000002↗

Reconstruction and identification of pairs of collimated τ-leptons decaying hadronically using s=13 TeV pp collision data with the ATLAS detector

This paper describes an algorithm for reconstructing and identifying a highly collimated hadronically decaying τ$$\tau $$-lepton pair with low transverse momentum. When two τ$$\tau $$-leptons are highly collimated, their visible decay products might overlap, degrading the reconstruction performance for each of the τ$$\tau $$-leptons. A dedicated treatment attempting to tag the τ$$\tau $$-lepton pair as a single object is required. The reconstruction algorithm is based on a large radius jet and its associated two leading subjets, and the identification uses a boosted decision tree to discriminate between signatures from τ+τ-$$\tau ^+\tau ^-$$ systems and those arising from QCD jets. The efficiency of the identification algorithm is measured in Zγ$$Z\gamma $$ events using proton–proton collision data at s=13$$\sqrt{s}=13$$ TeV collected by the ATLAS experiment at the Large Hadron Collider between 2015 and 2018, corresponding to an integrated luminosity of 139fb-1$$139\,\text{ fb}^{-1}$$. The resulting data-to-simulation scale factors are close to unity with uncertainties ranging from 26 to 37%.

Aad, G↗

Dual-prism interferometer for collimation testing

An air-wedge lateral-shear interferometer using two prisms is presented. With a variable shear, the interferometer is suitable for testing collimation of a wide range of beam sizes down to a few millimeters in diameter. No antireflection coatings are necessary. Collimation for a light source with short coherent length is also demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wavefront reversal technique for self-referencing collimation testing

We present a wavefront reversal technique to produce a dual-field fringe pattern for self-referencing collimation testing in wedge-plate lateral-shear interferometry. The method requires only a suitably placed cubic beam splitter to produce two replicas of the fringe field formed by the wedge-plate lateral-shear interferometer. One of the replicas has a fringe pattern that is the reverse of the other. With these two fringe fields, the collimation testing has a built-in reference, and the detection sensitivity is twice that of a single-wedge-plate technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design Considerations and Operational Features of the Collimators for the Fermilab Main Injector and Recycler

The Fermilab Main Injector system delivers 700 kW of 120 GeV Proton beam for neutrino experiments. Since 2013 this has been achieved using slip stacking accumulation in the Recycler with up to 12 batches from the Fermilab Booster per Main Injector Ramp Cycle. To control activation from beam loss, collimation systems in the Booster to Recycler transfer line, in the Recycler and in the Main Injector are employed. Residual radiation measurements around the ring with detailed studies at the collimators are required to maintain adequate loss control. We will review design considerations, operational parameters and activation results for more than ten years of operation. Simulations with MARS15 are used to explore the activation rates and the isotopic composition of the resulting activation.

43 PARTICLE ACCELERATORS↗

Verification of the Effectiveness of X-ray Machine Collimation

The Oak Ridge National Laboratory (ORNL) was tasked by the United States National Nuclear Security Administration’s Second Line of Defense (SLD) program with reducing the false alarm rate experienced by radiation portal monitors (RPM) installed near x-ray machines. Although the mechanism for interference between RPMs and x-ray machines is well understood, x-ray machines are often installed too near RPMs due to a variety of facility constraints. The result is underutilized RPMs that are plagued by a high false alarm rate from x-rays that escape the x-ray machine and are detected by the RPM. In this work, the effectiveness of an x-ray machine collimation system designed at ORNL is validated through the analysis of field data collected before and after the installation. The significant reduction in false alarm rate due to the collimation system is explicitly shown, and examples of field installations are provided. Utilization of the results presented here allows RPM systems to operate effectively even when installed near x-ray machines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of an Electron Gun for Hollow Electron Beam Collimation

Hollow electron beam collimation (HEBC) is a new technique developed to complement conventional beam collimation system to remove beam halo in a controlled fashion. We study the characteristics of the electron gun that produces the hollow electron beam. Cathode yield and beam profile measurements are used to extract information on gun performance. Results of characteristic measurements are presented.

43 PARTICLE ACCELERATORS↗

BNL Irradiation Damage Studies of the Metal Matrix Composite Mo-GR Considered for High Luminosity LHC Collimator Upgrade

A comprehensive experimental/analytical effort on the resilience of Mo-GR metal matrix composite to high energy proton beam irradiation combined with elevated temperatures has been undertaken at BNL on behalf of the CERN LHC Collimation effort as part of an effort to identify novel materials that will exhibit optimal performance in the high luminosity LHC upgrade. While the Mo-Gr composite was one of the four (4) different materials or composites (Mo, Glidcop, Cu-CD and Mo-Gr) that constituted the High Luminosity LHC collimation material campaign, this report focuses solely on Mo-GR with some reference to its constituents Mo and graphite (graphite studied in previous research or irradiation campaigns along with the carbonfiber composites). The multi-faceted study on Mo-GR (one of several different alloys and matrices) performed at BNL included the following stages: Irradiation damage phase using the 200 MeV proton beams of the BNL Linac and the BLIP target beamline. Specifically, Mo-GR samples encapsulated under vacuum in special capsules were exposed to direct protons as part of a multi-capsule, multi-material irradiation array. The long-term irradiation of ~8 weeks resulted in an accumulated fluence at the Mo-GR of ~10 21 p/cm 2 . The irradiation was conducted in two sessions (RUN 2013 and RUN 2014 of the BLIP operations in tandem with isotope production). Irradiation damage experiments using spallation neutrons at the BLIP beamline generated by 118 MeV protons that interact with and are stopped by an array of isotope producing targets. The Mo-GR capsule combined the effects of short-term proton irradiation and the effects of the mixed irradiating spectrum. Spallation-induced irradiation of Mo-GR at sub-zero temperatures utilizing the mixed field generated by spallation of 28 MeV protons of the BN Tandem on Mo targets Gamma spectrum analysis of the heavily irradiated Mo-Gr to enable the correlation of predicted isotope profile from Mo-Gr by transport codes and therefore the utilization of the validated transport code in other aspects of the damage induced on Mo-Gr by irradiation.

43 PARTICLE ACCELERATORS↗

Diffusion model for the time evolution of particle loss rates in collimator scans: a method for measuring stochastic transverse beam dynamics in circular accelerators

A diffusion model of the time evolution of loss rates caused by a step in collimator position is presented. It builds upon the model of Seidel (1994) and its assumptions: (1) constant diffusion rate within the range of the step and (2) linear halo tails. These hypotheses allow one to obtain analytical expressions for the solutions of the diffusion equation and for the corresponding loss rates vs. time. The present model addresses some of the limitiations of the previous model and expands it in the following ways: (a) losses before, during, and after the step are predicted/ (b) different steady-state rates before and after are explained/ (c) determination of the model parameters (diffusion coefficient, tail population, detector calibration, and background rate) is more robust and precise. These calculations are the basis for the measurement of transverse beam diffusion rates as a function of particle amplitude with collimator scans. The results of these measurements in the Tevatron will be presented in a separate report.

43 PARTICLE ACCELERATORS↗

Optimizing Laser-accelerated Ion Beams for a Collimated Neutron Source

High-flux neutrons for imaging and materials analysis applications have typically been provided by accelerator- and reactor-based neutron sources. A novel approach is to use ultraintense (>1018W/cm2) lasers to generate picosecond, collimated neutrons from a dual target configuration. In this article, the production capabilities of present and upcoming laser facilities are estimated while independently maximizing neutron yields and minimizing beam divergence. A Monte-Carlo code calculates angular and energy distributions of neutrons generated by D-D fusion events occurring within a deuterated target for a given incident beam of D+ ions. Tailoring of the incident distribution via laser parameters and microlens focusing modifies the emerging neutrons. Projected neutron yields and distributions are compared to conventional sources, yielding comparable on-target fluxes per discharge, shorter time resolution, larger neutron energies and greater collimation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evolution of global relativistic jets: Collimations and expansion with kKHI and the Weibel instability

In the study of relativistic jets one of the key open questions is their interaction with the environment. Here we study the initial evolution of both electron–proton (e{sup --}−p{sup +}) and electron–positron (e{sup ±}) relativistic jets, focusing on their lateral interaction with ambient plasma. We follow the evolution of toroidal magnetic fields generated by both the kinetic Kelvin–Helmholtz and Mushroom instabilities. For an e{sup --}−p{sup +} jet, the induced magnetic field collimates the jet and electrons are perpendicularly accelerated. As the instabilities saturate and subsequently weaken, the magnetic polarity switches from clockwise to counterclockwise in the middle of the jet. For an e{sup ±} jet, we find strong mixing of electrons and positrons with the ambient plasma, resulting in the creation of a bow shock. The merging of current filaments generates density inhomogeneities that initiate a forward shock. Strong jet–ambient plasma mixing prevents a full development of the jet (on the scale studied), revealing evidence for both jet collimation and particle acceleration in the forming bow shock. Differences in the magnetic field structure generated by e{sup --}−p{sup +} and e{sup ±} jets may contribute to the polarization properties of the observed emission in AGN jets and gamma-ray bursts.

79 ASTRONOMY AND ASTROPHYSICS↗

A Quasi-static Hyper-resistive Model of Ultra-high-energy Cosmic-ray Acceleration by Magnetically Collimated Jets Created by Active Galactic Nuclei

This is the fourth in a series of companion papers showing that when an efficient dynamo can be maintained by accretion disks around supermassive black holes in active galactic nuclei, it will lead to the formation of a powerful, magnetically collimated helix that could explain the observed jet/radiolobe structures on very large scales. In this work, we present a hyper-resistive kinetic theory that shows how different instabilities can cause the slowly evolving magnetically collimated jets to accelerate ions and electrons in different regions of jets and lobes. In particular, we propose that the Drift Cyclotron Loss Cone instability at the ends of jets can accelerate ions up to the observed ultra-high-energy cosmic rays with energies ≈1020 eV. Based on this jet/lobe structure model and its associated acceleration processes, we estimate cosmic-ray intensities and likely radiative signatures and compare them with observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation collimator and systems incorporating same

A collimator including a housing having disposed therein a shield element surrounding a converter core in which a photon beam is generated from electrons emanating from a linear accelerator. A beam channeler longitudinally adjacent the shield element has a beam aperture therethrough coaxially aligned with, and of the same diameter as, an exit bore of the converter core. A larger entry bore in the converter core is coaxial with, and longitudinally separated from, the exit bore thereof. Systems incorporating the collimator are also disclosed.

47 OTHER INSTRUMENTATION↗

Simulation of Hollow Electron Beam Collimation in the Fermilab Tevatron Collider

The concept of augmenting the conventional collimation system of high-energy storage rings with a hollow electron beam was successfully demonstrated in experiments at the Tevatron. A reliable numerical model is required for understanding particle dynamics in the presence of a hollow beam collimator. Several models were developed to describe imperfections of the electron beam profile and alignment. The features of the imperfections are estimated from electron beam profile measurements. Numerical simulations of halo removal rates are compared with experimental data taken at the Tevatron.

43 PARTICLE ACCELERATORS↗

Solar concentrator with integrated tracking and light delivery system with collimation

A solar light distribution system includes a solar light concentrator that is affixed externally to a light transfer tube. Solar light waves are processed by the concentrator into a collimated beam of light, which is then transferred through a light receiving port and into the light transfer tube. A reflector directs the collimated beam of light through the tube to a light distribution port. The interior surface of the light transfer tube is highly reflective so that the light transfers through the tube with minimal losses. An interchangeable luminaire is attached to the light distribution port and distributes light inside of a structure. A sun tracking device rotates the concentrator and the light transfer tube to optimize the receiving of solar light by the concentrator throughout the day. The system provides interior lighting, uses only renewable energy sources, and releases no carbon dioxide emissions into the atmosphere.

14 SOLAR ENERGY↗

The New Transfer Line Collimation System for the LHC High Luminosity Era

A set of passive absorbers is located at the end of each of the 3 km long injection lines to protect the LHC in case of failures during the extraction process from the LHC’s last pre-injector or the beam transfer itself. In case of an erroneous extraction, the absorbers have to attenuate the beam to a safe level and be robust enough themselves to survive the impact. These requirements are difficult to fulfil with the very bright and intense beams produced by the LHC injectors for the high luminosity era. This paper revisits the requirements for the SPS-to-LHC transfer line collimation system and the adapted strategy to fulfill these for the LHC high luminosity operation. A possible solution for the new transfer line collimation system is presented.

43 PARTICLE ACCELERATORS↗

Hollow Electron Beam Collimation for HL-LHC - Effects on the Beam Core

Collimation with hollow electron beams is currently one of the most promising concepts for active halo control in the High Luminosity Large Hadron Collider (HL-LHC). To ensure the successful operation of the hollow beam collimator the unwanted effects on the beam core, which might arise from the operation with a pulsed electron beam, must be minimized. This paper gives a summary of the effect of hollow electron lenses on the beam core in terms of sources, provides estimates for HL-LHC and discusses the possible mitigation methods.

43 PARTICLE ACCELERATORS↗

Characterizations of the radioactive waste by the remotely-controlled collimated spectrometric system

Decontamination and decommissioning of the research reactors MR (Testing Reactor) and RFT (Reactor of Physics and Technology) has recently been initiated in the National Research Center (NRC) 'Kurchatov institute', Moscow. In the building, neighboring to the reactor, the storage of HLRW is located. The storage is made of monolithic concrete in which steel cells depth 4 m are located. In cells of storage the HLRW packed into cases are placed. These the radioactive waste are also subject to export on long storage in the specialized organization. For characterization of the radioactive waste in cases the remote-controlled collimated spectrometer system was used. The system consists of a spectrometric collimated gamma-ray detector, a color video camera and a control unit, mounted on a rotator, which are mounted on a tripod with the host computer. For determination of specific activity of radionuclides in cases, it is developed programs of calculation of coefficients of proportionality of specific activity to the corresponding speeds of the account in peaks of full absorption at single specific activity of radionuclides in cases. For determination of these coefficients the mathematical model of spectrometer system based on the Monte-Carlo method was used. Dependences of calibration coefficients for various radionuclides from distance between the detector and a case at various values of the radioactive waste density in cases are given. Measurements of specific activity in cases are taken and are discussed. By results of measurements decisions on the appeal of the radioactive waste being in cases are made. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗