Search NASA⌕ Search

SEARCH · Search NASA

Results for “conditioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Exploring the Effects of Varying Pre-Chamber Geometry in a Heavy-Duty Natural Gas Optical Engine under Dilution Conditions

Pre-chamber combustion is an advanced ignition strategy that has been shown to enhance spark ignition (SI) combustion stability in natural gas (NG) engines by providing distributed ignition sites from turbulent jets and enhancing main-chamber turbulence. Pre-chamber combustion has been proven especially advantageous compared to SI in ultra-lean and dilute operating conditions. This work involves experimental investigation of the effects of varying passive pre-chamber nozzle configuration on pre-chamber and main chamber combustion under simulated exhaust gas recirculation (EGR) dilution (0 and 20%) conditions in a heavy-duty, single-cylinder, optically accessible NG engine at stoichiometric fuel-air ratio. Pre-chamber nozzle configurations include four pre-chambers with constant nozzle area to pre-chamber volume ratio (A/V) with different nozzle sizes and orientations and one configuration with larger nozzles. The optical engine is operated in a skip-fire sequence consisting of 18 motored cycles followed by two consecutive fired cycles to elucidate the effect of combustion residuals (internal EGR) on combustion evolution. Pressure-based diagnostics are used to monitor pre-chamber and subsequent main chamber combustion, and optical diagnostics include high-speed OH* chemiluminescence to visualize the development of pre-chamber jets and the resulting ignition of the main chamber charge. Heat release analysis of the in-cylinder pressure data indicates that a faster pre-chamber pressure rise does not always translate into faster main-chamber combustion. The pre-chamber with the smallest nozzle diameter produced the highest pre-chamber pressure rise and fastest combustion under non-diluted conditions. However, dilution delays the main chamber ignition for smaller nozzles despite a comparable rise in pre-chamber pressure compared to configurations with larger nozzles. This effect is more pronounced for cycles with in-cylinder combustion residuals in addition to external dilution. Additionally, it was observed that pre-chambers with swirling nozzles have a faster pressure rise in the pre-chamber and main chamber under dilute conditions. Optical diagnostics suggest that the main reason for the delay between the pre-chamber pressure rise and main-chamber combustion lies in jet quenching and delayed re-ignition, which can even lead to misfire if jets emitted from small nozzles combined with dilution fail to re-ignite.

Dhotre, Akash [University Of Minnesota-Twin Cities↗

Albedo susceptibility of northeastern Pacific stratocumulus: the role of covarying meteorological conditions

Abstract. Quantification of the radiative adjustment of marine low clouds to aerosol perturbations, regionally and globally, remains the largest source of uncertainty in assessing current and future climate. One of the important steps towards quantifying the role of aerosol in modifying cloud radiative properties is to quantify the susceptibility of cloud albedo and liquid water path (LWP) to perturbations in cloud droplet number concentration (Nd). We use 10 years of spaceborne observations from the polar-orbiting Aqua satellite to quantify the albedo susceptibility of marine low clouds to Nd perturbations over the northeast (NE) Pacific stratocumulus (Sc) region. Mutual information analysis reveals a dominating control of cloud state (e.g., LWP and Nd) on low-cloud albedo susceptibility, relative to the meteorological states that drive these cloud states. Through a LWP–Nd space decomposition of albedo susceptibilities, we show clear separation among susceptibility regimes (brightening or darkening), consistent with previously established mechanisms through which aerosol modulates cloud properties. These regimes include (i) thin non-precipitating clouds (LWP < 55 g m−2) that exhibit brightening (occurring 37 % of the time), corresponding to the Twomey effect; (ii) thicker non-precipitating clouds, corresponding to entrainment-driven negative LWP adjustments that manifest as a darkening regime (36 % of the time); and (iii) another brightening regime (22 % of the time) consisting of mostly precipitating clouds, corresponding to precipitation-suppression LWP positive adjustments. Overall, we find an annual-mean regional low-cloud brightening potential of 20.8±2.68 W m−2 ln(Nd)−1, despite an overall negative LWP adjustment for non-precipitating marine stratocumulus, owing to the high occurrence of the Twomey–brightening regime. Over the NE Pacific, clear seasonal covariabilities among meteorological factors related to the large-scale circulation are found to play an important role in grouping conditions favorable for each susceptibility regime. When considering the covarying meteorological conditions, our results indicate that for the northeastern Pacific stratocumulus, clouds that exhibit the strongest brightening potential occur most frequently within shallow marine boundary layers over a cool ocean surface with a stable atmosphere and a dry free troposphere above. Clouds that exhibit a darkening potential associated with negative LWP adjustments occur most frequently within deep marine boundary layers in which the atmospheric instability and the ocean surface are not strong and warm enough to produce frequent precipitation. Cloud brightening associated with warm-rain suppression is found to preferably occur either under unstable atmospheric conditions or humid free-tropospheric conditions that co-occur with a warm ocean surface.

54 ENVIRONMENTAL SCIENCES↗

Burning conditions and transportation pathways determine biomass-burning aerosol properties in the Ascension Island marine boundary layer

African biomass-burning aerosol (BBA) in the southeast Atlantic Ocean (SEA) marine boundary layer (MBL) is an important contributor to Earth’s radiation budget yet its representation remains poorly constrained in regional and global climate models. Data from the Layered Atlantic Smoke Interactions with Clouds (LASIC) field campaign on Ascension Island (-7.95° N, -14.36° E) detail how fire source regions (burning conditions and fuel type), transport pathways, and longer-term chemical processing affect the chemical, microphysical, and optical properties of the BBA in the remote MBL between June and September of 2017. Ten individual plume events characterize the seasonal evolution of BBA characteristics. Inefficient burning conditions, determined by the mass ratio of refractory black carbon to above-background carbon monoxide (rBC:ΔCO), enhance organic- and sulfate-rich aerosol concentrations in June–July. In contrast, the heart of the burning season exhibited higher rBC:ΔCO values indicative of efficient burning conditions, correlating with more rBC-enriched BBA. Toward the end of the burning season, a mix of burning conditions results in increased variation of the BBA properties. The BBA transit to Ascension Island was predominantly through slow-moving pathways in the MBL and lower free troposphere (FT), facilitating prolonged chemical transformations through heterogeneous and aqueous phase processes. Heterogeneous oxidation can persist for up to 10 days, resulting in a considerable decrease in organic aerosol (OA) mass. OA to rBC mass ratios (OA:rBC) in the MBL between 2 and 5 contrast to higher values of 5 to 15 observed in the nearby FT. Conversely, early-season aqueous-phase processes primarily contributed to aerosol oxidation and some aerosol production, but not appreciable aerosol removal. These two chemical processes yield more light-absorbing BBA in the MBL than in the FT and explain the notably low scattering albedo at 530 nm (SSA 530 ) values (< 0.80) at Ascension Island. This study establishes a robust correlation between SSA 530 and OA:rBC across both MBL and FT, underscoring the dependency of optical properties on chemical composition. These findings highlight how the interplay between chemical composition and atmospheric processing can be improved in global and regional climate models. Questions remain on the mixing of aerosols with different pathway histories, and on what accounts for the doubling of the mass absorption coefficient in the boundary layer.

54 ENVIRONMENTAL SCIENCES↗

CondiDiag1.0: a flexible online diagnostic tool for conditional sampling and budget analysis in the E3SM atmosphere model (EAM)

Abstract. Numerical models used in weather and climate prediction take into account a comprehensive set of atmospheric processes (i.e., phenomena) such as the resolved and unresolved fluid dynamics, radiative transfer, cloud and aerosol life cycles, and mass or energy exchanges with the Earth's surface. In order to identify model deficiencies and improve predictive skills, it is important to obtain process-level understanding of the interactions between different processes. Conditional sampling and budget analysis are powerful tools for process-oriented model evaluation, but they often require tedious ad hoc coding and large amounts of instantaneous model output, resulting in inefficient use of human and computing resources. This paper presents an online diagnostic tool that addresses this challenge by monitoring model variables in a generic manner as they evolve within the time integration cycle. The tool is convenient to use. It allows users to select sampling conditions and specify monitored variables at run time. Both the evolving values of the model variables and their increments caused by different atmospheric processes can be monitored and archived. Online calculation of vertical integrals is also supported. Multiple sampling conditions can be monitored in a single simulation in combination with unconditional sampling. The paper explains in detail the design and implementation of the tool in the Energy Exascale Earth System Model (E3SM) version 1. The usage is demonstrated through three examples: a global budget analysis of dust aerosol mass concentration, a composite analysis of sea salt emission and its dependency on surface wind speed, and a conditionally sampled relative humidity budget. The tool is expected to be easily portable to closely related atmospheric models that use the same or similar data structures and time integration methods.

58 GEOSCIENCES↗

Numerical study of heat transfer enhancement in laminar and turbulent flow in enhanced tubes with uniform and non-uniform thermal boundary conditions

Various types of tube enhancements have been proposed in order to increase heat transfer while minimizing any associated increases in pressure drop. This paper presents a numerical study of two different types of enhanced tubes: the relatively common twisted tape insert tube, and a novel tube with airfoil shaped pins on the inner surface. Each tube is studied in both the laminar and turbulent flow regime. In addition to the typical constant temperature and constant flux boundary conditions, a non-constant heat flux boundary condition is applied on one half of the tube, a situation which may be encountered when absorbing solar radiation. In general, each type of enhanced tube offers a thermal performance factor greater than unity at certain Re. In addition, the non-uniform heat flux boundary condition appears to function similarly as the uniform heat flux boundary condition.

Sandlin, Matthew J.↗

Effect of Cultivation Conditions on the Bioconversion of 4-Hydroxybenzoic Acid in Two White-Rot Fungi

White-rot fungi (WRF) are the most efficient organisms for lignin degradation in nature. A recent study has also shown the ability of WRF in funneling lignin-derived aromatics, including 4-hydroxybenzoic acid (4HBA) and vanillic acid, to central metabolism. However, it is unknown how the cultivation conditions affect the conversion of lignin-derived aromatic compounds. To address this, we performed multi-omic analyses and tracked the conversion of 4HBA in different cultivation conditions in two white-rot fungi: Trametes versicolor and Ceriporiopsis subvermispora. Specifically, we evaluated the effect of static and agitation cultivation conditions in the absence and the presence of antioxidants on fungal performance. We found that the comparison between static and agitation has the higher number of differentially expressed genes or protein abundances at the transcriptomic and proteomic levels, respectively, compared to the presence or the absence of antioxidants. Gene mapping on the enzymatic steps of the proposed 4HBA conversion pathway revealed that agitation causes upregulation of several oxidase genes such as aldehyde dehydrogenases, aldehyde oxidases, and hydroxylases in both fungi. Time-course experiments including 4HBA and cellobiose as carbon sources showed that T. versicolor exhibited higher 4HBA conversion levels in agitation (~110% more conversion, compared to static cultivation conditions) and in the presence of antioxidants (~10% more conversion, compared to the treatments without antioxidants). Interestingly, these trends were not found in C. subvermispora, suggesting different carbon metabolism in both species. Our findings are fundamental to better understand carbon sequestration from lignin in WRF, which will be key for future applications in the lignin valorization field.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Generation IV Benchmarking of TRISO Fuel Performance Models Under Accident Conditions Final Report

The Generation IV International Forum (GIF) is a co-operative international endeavor of fourteen members organized to carry out the research and development needed to establish the feasibility and performance capabilities of the next generation nuclear energy systems. GIF selected six reactor technologies, amongst which is the Very High Temperature Reactor (VHTR) that is primarily dedicated to the cogeneration of electricity and hydrogen. The technical basis for VHTR is the tristructural isotropic (TRISO)-coated particle fuel, the graphite as the core structure, helium coolant, as well as the dedicated core layout and lower power density to removal decay heat in a natural way. At the heart of safety features of the VHTR concept lie the TRISO fuel particles that are designed to keep their structural integrity and retain fission products at temperatures up to 1600°C. As part as the design and future operation of VHTRs, a key aspect is the accurate prediction of fuel performance under irradiation and accident conditions. Modeling and simulation allow prediction of TRISO fuel behavior when subject to neutron flux and in high temperature accident scenarios. The refinement of the fuel performance models and codes is performed by comparison to in-pile and out-of-pile experimental data that reproduce the expected irradiation conditions in high temperature gas-cooled reactors (HTGRs). Historically, the International Atomic Energy Agency (IAEA) developed a benchmark dedicated to the validation of predictive methods for fuel and fission product behavior through the Coordinated Research Program CRP-2 (IAEA, 1997). CRP-2 was later updated to cover fuel fabrication, quality assurance, irradiation performance, safety testing, and spent fuel. The scope of the resulting CRP-6 benchmarks focused on HTGR fuel performance and fission product release (IAEA, 2012). Taking advantage of additional TRISO fuel fabrication, irradiation, and safety testing campaigns, GIF launched a Generation IV Benchmarking of TRISO Fuel Performance Models under Accident Conditions in late 2015. This GIF benchmark is a three-year program steered by Idaho National Laboratory (INL, USA). The other participants include the Japan Atomic Energy Agency (JAEA, Japan) and the Korea Atomic Energy Research Institute (KAERI, Korea). The objectives of the benchmark are to: follow on the IAEA CRP benchmarks, (2) model fission product release under accident conditions, (3) compare results obtained by the fuel performance modeling codes of the benchmark participants, and (4) compare these code predictions to experimental data. Safety tests chosen for modeling include the first and second experiments of the Advanced Gas Reactor program (AGR-1 and AGR-2) and the High Flux Reactor (HFR) EU1bis experiment. This report presents the results obtained by the three research institutions using their respective fuel performance modeling codes. Comparisons of the corresponding fission product release predictions are made with experimental data from AGR-1, AGR-2, and HFR-EU1bis. The benchmark results show good agreements between all participants but also show a general trend of over-prediction of the experimental release data, which is mainly attributed to the use of over-estimated diffusion coefficients.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Numerical study of heat transfer enhancement in laminar and turbulent flow in enhanced tubes with uniform and non-uniform thermal boundary conditions

Various types of tube enhancements have been proposed in order to increase heat transfer while minimizing any associated increases in pressure drop. This paper presents a numerical study of two different types of enhanced tubes: the relatively common twisted tape insert tube, and a novel tube with airfoil shaped pins on the inner surface. Each tube is studied in both the laminar and turbulent flow regime. In addition to the typical constant temperature and constant flux boundary conditions, a non-constant heat flux boundary condition is applied on one half of the tube, a situation which may be encountered when absorbing solar radiation. In general, each type of enhanced tube offers a thermal performance factor greater than unity at certain Re. In addition, the non-uniform heat flux boundary condition appears to function similarly as the uniform heat flux boundary condition.

Sandlin, M↗

Extended FFT-based micromechanical formulation to consider general non-periodic boundary conditions

Here, this paper presents a new approach for applying non-periodic boundary conditions in the context of FFT-based methods to solve micromechanical problems in heterogeneous solids. The domain of the original problem is extended to satisfy the periodicity requirements at the boundary of the extended domain. The velocity constraint on the boundary of the original domain is replaced by a corresponding constraint on the velocity gradient in the extended volume, and a two-level augmented Lagrangian method is used to enforce the constraint. The proposed method is implemented as an extension of the large-strain elasto-viscoplastic FFT-based (LS-EVPFFT) model of Zecevic et al. (2022). The proposed method is verified in the cases of fully imposed velocity boundary conditions and mixed velocity/traction-free boundary conditions. The accuracy and convergence of the method are studied next, followed by applications to bending and indentation of polycrystals that illustrate the extended capabilities of the proposed formulation.

36 MATERIALS SCIENCE↗

Joint Modeling of Wind Speed and Wind Direction Through a Conditional Approach

Atmospheric near surface wind speed and wind direction play an important role in many applications, ranging from air quality modeling, building design, wind turbine placement to climate change research. It is therefore crucial to accurately estimate the joint probability distribution of wind speed and direction. In this work, we develop a conditional approach to model these two variables, where the joint distribution is decomposed into the product of the marginal distribution of wind direction and the conditional distribution of wind speed given wind direction. To accommodate the circular nature of wind direction, a von Mises mixture model is used; the conditional wind speed distribution is modeled as a directional dependent Weibull distribution via a two-stage estimation procedure, consisting of a directional binned Weibull parameter estimation, followed by a harmonic regression to estimate the dependence of the Weibull parameters on wind direction. A Monte Carlo simulation study indicates that our method outperforms two other approaches in estimation efficiency: one that utilizes periodic spline quantile regression and another that generates data from the commonly used Abe-Ley distribution for cylindrical data. We illustrate our method by using the output from a regional climate model to investigate how the joint distribution of wind speed and direction may change under some future climate scenarios. Our method indicates significant changes in the variation of wind speed with respect to some directions.

17 WIND ENERGY↗

Tool-workpiece stick-slip conditions and their effects on torque and heat generation rate in the friction stir welding

Friction stir welding (FSW) has found increased applications in automotive and aerospace industries due to its advantages of solid-state bonding, no fusion and melting, and versatility in various working conditions and material combinations. However, the relationship among processing parameters, material properties, and bonding extent and fidelity remains largely empirical, primarily because of the lack of the mechanistic understanding of the tool-workpiece frictional behavior that affects our subsequent understanding of microstructural evolution and interface bonding formation. While the tool-workpiece stick-slip condition is believed to dictate the resulting torque and heat generation rate during the welding process, it remains rare and elusive to conduct a quantitative experimental measurement of such interfacial field. On the other hand, numerical simulations based on Computational Fluid Dynamics (CFD) rely on ad hoc assumptions of interfacial pressure and shear-stress conditions, but predictions can only be validated via the medium- and far-range temperature field which is known to be insensitive to the interfacial frictional behavior. This work first presents a comparison among two CFD-based simulation methodologies and the Coupled Eulerian Lagrangian (CEL) model in finite element method, the last of which uses the Coulomb friction so that the stick-slip is naturally developed. Based on the Hill-Bower similarity relationship in the contact analysis, an analytical model is developed here to prove why a constant stick-slip fraction will be developed in the steady state, to correlate the stick-slip fraction to processing parameters such as the tool spin rate, and further to derive dimensionless functions for torque and heat-generation-rate predictions. Pros and cons of various numerical approaches in predicting stick-slip are discussed, and our analytical model has been found to agree well with our numerical simulation and literature experimental results. These analyses provide the critical strain-rate and temperature fields that are needed for the bonding analysis in our future work.

36 MATERIALS SCIENCE↗

Sensitivity analysis of an automated fault detection algorithm for residential air-conditioning systems

The state of the art of fault detection and diagnosis (FDD) for residential air-conditioning systems is expensive and not yet amenable to widespread implementation. FDD for homes can significantly reduce utility costs, and increase the lifespan of the equipment. The cost barriers currently, however, make FDD for homes economically unviable for large scale implementation. In prior work, we offered a solution to reduce FDD costs by proposing an automated fault detection algorithm to serve as a screening step before more expensive FDD tests can be conducted. The algorithm uses only the home thermostat and local weather information to identify thermodynamic parameters and detect high-impact air-conditioning faults, including those that occur during equipment installation. We had tested the algorithm on a single EnergyPlus™ model of a home in Orlando, Florida. The thermodynamic parameter identification process is highly nonconvex involving several local optimal solutions. In this paper we propose a novel method to select the best model for fault detection from among the list of local optimal solutions to make the algorithm more robust to homes of different construction, without which the fault detection process would be infeasible. Another unique contribution of the paper is implementing the solution on real-world data. We also bring the algorithm closer to market by testing it on real-world data. We implement the algorithm on data obtained from experiments conducted by the Florida Solar Energy Center (FSEC) on a laboratory home equipped with a heat pump where faults were intentionally added for a period of seven months. The algorithm successfully detected an undercharge fault with 70.6% accuracy, concurrent duct leakage and undercharge faults with 85.2% accuracy, and duct leakage faults with 69.1% accuracy. A sensitivity analysis is also performed on EnergyPlus models of nine types of homes that vary in construction to demonstrate the robustness of the algorithm. Finally, the algorithm achieves an average accuracy of 71% for no-fault condition, 77% for 40% undercharge fault, and 76% for duct-leak fault.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integral boundary conditions in phase field models

Modeling the chemical, electric and thermal transport as well as phase transitions and the accompanying mesoscale microstructure evolution within a material in an electronic device setting involves the solution of partial differential equations often with integral boundary conditions. Employing the familiar Poisson equation describing the electric potential evolution in a material exhibiting insulator to metal transitions, we exploit a special property of such an integral boundary condition, and we properly formulate the variational problem and establish its well-posedness. Next, we compare our method with the commonly-used Lagrange multiplier method that can also handle such boundary conditions. Numerical experiments demonstrate that our new method achieves optimal convergence rate in contrast to the conventional Lagrange multiplier method. Furthermore, the linear system derived from our method is symmetric positive definite, and can be efficiently solved by Conjugate Gradient method with algebraic multigrid preconditioning.

97 MATHEMATICS AND COMPUTING↗

Automated fault detection of residential air-conditioning systems using thermostat drive cycles

Residential air conditioning equipment comprises a significant portion of the total energy consumption of a home. Unfortunately, air-conditioning systems can be susceptible to faulty operation either from installation errors or faults that accrue over the equipment’s lifetime. This paper presents a novel automated fault detection algorithm for residential air-conditioning systems that can alert the homeowner of the presence of these faults. The proposed algorithm utilizes only the home’s thermostat and outside air temperature to perform automated fault detection over the course of the equipment’s lifetime, including immediately after installation. The algorithm uses an extended Kalman filter approach to identify a three-resistor, two-capacitor (3R2C) electrical equivalent thermodynamic model. The identified 3R2C model is used to predict cooling times during a testing period comprising of a series of thermostat drive-cycle experiments. We tested the algorithm on an EnergyPlus™ model of a typical residential building in Orlando, Florida. Duct faults, indoor airflow faults, and refrigerant undercharge faults were introduced into the building model one at a time. The algorithm was able to accurately determine duct-leak faults, 40% airflow faults, 40% undercharge faults, and no-fault cases with an accuracy of 70%, 77%, 82%, and 87%, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost-Performance Trade-off in thermoelectric air conditioning system with graded and constant material properties

Thermoelectric (TE) air cooling is a solid-state technology that has the potential to replace conventional vapor compression-based air conditioning. In this paper, we present a detailed system-level modeling for thermoelectric air conditioning system with position-dependent (graded) and constant material properties. Strategies for design optimization of the system are provided in terms of cost-performance trade-off. Realistic convection heat transfer at both sides of the system are taken into account in our modeling. Here, the effects of convection heat transfer coefficients, air flowrate, and thermoelectric material properties are investigated with varying key parameters such as TE leg thickness, module fill factor, and input current. Both constant material properties and graded properties are considered for the TE materials, and they are compared in terms of the degree of cooling, coefficient of performance (COP), and power consumption. For graded materials, we employ one-dimensional finite element methods to solve the coupled electrical and thermal current equations with arbitrary profile of material properties varying with position along the TE legs. We find that graded materials can enhance the degree of cooling, but only at the expense of COP, compared to the case of constant property materials. With constant material properties of ZT = 1 and relatively low electric current, the power consumption of TE coolers can be lower than those of conventional air conditioners at an equivalent cooling capacity. Considering additional advantages such as demand-flexible operation, low noise, and high scalability, thermoelectric cooling could be a competitive technology for future air conditioning applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of crystallographic orientation on calcite dissolution under alkaline conditions

Here, this study investigates the dissolution of calcite’s (104) and (100) surfaces under alkaline conditions (pH 8.8–13.1) using vertical scanning interferometry under flow-through conditions. The dissolution rate of (100) surfaces decreases with increasing pH. For example, the dissolution rate at pH 8.8 is more than 20 times higher than that at pH 13.1. In contrast, the dissolution rate of (104) surfaces is far less sensitive to pH. We explain these observations as being on account of the preferential adsorption of [OH – ] on (100) surfaces, inhibiting their dissolution. Particularly, this is because Ca-surface sites on (100) surfaces are less coordinated and have a stronger tendency for [OH – ] adsorption. As a result, (100) surfaces dissolve nearly twice as fast as (104) surfaces at pH 8.8, whereas (104) surfaces dissolved ~4.5 times faster than (100) surfaces at pH 13.1; indicating an inversion in dissolution behavior. The dissolution rate of (104) surfaces at pH 13.1 is 60 % of the rate at pH 10–12 because of the formation of slow dissolving microfacets of other orientations. The rhombohedral dissolution etch-pits formed on (104) surfaces, at lower pH’s, disappeared upon exposure to solutions with pH > 12 and were replaced by protrusions. The addition of up to 4m (molality) NaCl enhances the dissolution of (104) surfaces at pH 8.8–13.1 and (100) surfaces at pH 8.8–11.0, and inhibited the dissolution of (100) surfaces at pH = 12.0–13.1. In addition, the competing adsorption between OH – and CO 3 2– species mitigates the inhibition effects of CO 3 2– on both surfaces at pH 13.1 compared to pH 11, and the dissolution of (100) surfaces is far less affected by CO 3 2– than (104) surfaces. These results provide new insights into the rates and mechanisms of how crystallographic orientations affect calcite’s dissolution at alkaline pH conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A high efficiency rooftop air conditioning system using multi-speed compressors

This study delineates a meticulous exploration of technologies to enhance the energy efficiency of rooftop air conditioning units, employing the DOE/ORNL heat pump design model for comprehensive engineering design and optimization. A baseline rooftop air conditioning unit, featuring a 13 ton (45.7 kW) cooling capacity and a 17.9 integrated energy efficiency ratio, served as the point of departure for substantive efficiency enhancements. Key modifications included the consolidation of two refrigerant circuits into one, integrating three parallel 2-stage (dual-speed) compressors, fan replacements with high-efficiency substitutes. Notably, a lower global warming potential refrigerant, R452B, was evaluated as a substitute for R-410A, demonstrating better performance in the lab prototype. Further, the achieved measured integrated energy efficiency ratio of 21.4 in the lab prototype surpassed the baseline integrated energy efficiency ratio. Comparative evaluations between R410A and R452B indicated heightened efficiency with the latter, showcasing a lab-demonstrated integrated energy efficiency ratio of 22.4 at the rated capacity of 13.8 ton (48.5 kW) and 23.9 integrated energy efficiency ratio at the rated capacity of 10 ton (35.2 kW). This research underscores the successful development of a rigorous, energy efficient rooftop air conditioning unit prototype with noteworthy environmental and economic implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Entropy stable modal discontinuous Galerkin schemes and wall boundary conditions for the compressible Navier-Stokes equations

Entropy stable schemes ensure that physically meaningful numerical solutions also satisfy a semi-discrete entropy inequality under appropriate boundary conditions. Here in this work, we describe a discretization of viscous terms in the compressible Navier-Stokes equations which enables a simple and explicit imposition of entropy stable no-slip and reflective (symmetry) wall boundary conditions for discontinuous Galerkin (DG) discretizations. Specifically, we derive methods for imposing adiabatic no-slip and reflective (symmetry) boundary conditions for modal entropy stable DG formulations which preserve a semi-discrete entropy inequality. Numerical results confirm the robustness and accuracy of the proposed approaches.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗