A combat simulator with controls for attacker and evader pilots
Air combat simulator with attacker and evader pilots control capability, comparing simulated interceptions with flight test maneuvers
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Air combat simulator with attacker and evader pilots control capability, comparing simulated interceptions with flight test maneuvers
Effects of fuel vaporization on the exhaust emission levels of oxides of nitrogen (NOX), carbon monoxide, total hydrocarbons, and smoke number were obtained in an experimental turbojet combustor segment. Two fuel injector types were used in which liquid ASTM A-1 jet fuel and vapor propane fuel were independently controlled to simulate varying degrees of vaporization. Tests were conducted over a range of inlet-air temperatures from 478 to 700 K (860 to 1260 R), pressures from 4 to 20 atmospheres, and combustor reference velocities from 15.3 to 27.4 m/sec (50 to 90 ft/sec). Converting from liquid to complete vapor fuel resulted in NOX reductions as much as 22 percent and smoke number reductions up to 51 percent.
Effects of fuel vaporization on the exhaust emission levels of oxides of nitrogen, carbon monoxide, total hydrocarbons, and smoke number were obtained in an experimental turbojet combustor segment. Two different fuel injectors were used in which liquid ASTM A-1 jet fuel and vapor propane fuel were independently controlled to simulate varying degrees of vaporization. Tests were conducted over a range of inlet-air temperatures from 478 to 700 K, pressures from 4 to 20 atm, and combustor reference velocities from 15.3 to 27.4 m/sec. Converting from liquid to complete vapor fuel resulted in oxides of nitrogen reductions of as much as 22 percent and smoke number reductions up to 51 percent. Supplement data are also presented on flame emissivity, flame temperature, and primary-zone liner wall temperatures.
Effect of fuel vaporization on the exhaust emission levels of oxides of nitrogen (NOx), carbon monoxide, total hydrocarbons and smoke number were obtained in an experimental turbojet combustor segment. Two fuel injector types were used in which liquid ASTM A-1 jet fuel and vapor propane fuel were independently controlled to simulate varying degrees of vaporization. Tests were conducted over a range of inlet-air temperatures from 478 to 700 K, pressures from 4 to 20 atmospheres, and combustor reference velocities from 15.3 to 27.4 m/sec. Converting from liquid to complete vapor fuel resulted in NOx reductions as much as 22% and smoke number reductions up to 51%.
This paper describes the development of a hybrid computer simulation of a TF34-GE-100 turbofan engine with post-stall capability. The simulation operates in real-time and will be used to test and evaluate stall recovery control modes for this engine. The simulation calculations are performed by an analog computer with a peripheral multivariable function generation unit used for computing bivariate functions. Tabular listings of a simulation variables are obtained by interfacing to a digital computer and using a custom software package for data collection and display.
This paper describes the development of a hybrid computer simulation of a TF34-GE-100 turbofan engine with post-stall capability. The simulation operates in real-time and will be used to test and evaluate stall recovery control modes for this engine. The simulation calculations are performed by an analog computer with a peripheral multivariable function generation unit used for computing bivariate functions. Tabular listings of simulation variables are obtained by interfacing to a digital computer and using a custom software package for data collection and display.
A number of major challenges were faced in the design and development of the Orbiter Active Thermal Control Subsystem (ATCS). At the system level, the initial challenges were to define an approach that would interface dual Freon coolant loops with multiple coolant loops from other vehicle subsystems with the lowest weight penalty to the Orbiter; and to provide highly responsive vehicle heat rejection throughout all of the Orbiter mission phases. Optimized heat exchangers, representing an advance in the state-of-the-art in heat exchanger design, were developed to transfer heat between the orbiter Freon coolant loops and five other vehicle systems. Flash evaporation was selected as a highly efficient and responsive means for cooling the Orbiter Freon loops during ascent and entry. The Flash Evaporator Subsystem (FES) utilizes cyclic water spray cooling in a chamber maintained at or below the water triple point pressure. A summary of the basic heat transfer research conducted to identify the fundamental heat transfer processes involved in water spray cooling in support of the FES design is given. The high fidelity dynamic analytical model of the FES that was generated to aid in the design of control logic, evaluate performance and simulate ground test and flight anomalies is discussed. A description of the FES and Integrated ATCS testing conducted in the SESL chamber A at NASA-JSC is also presented.
Advantages and disadvantages of computer-based simulations reviewed. Report reviews current methods for evaluation of TERP's. Discusses feasibility, benefits, liabilities of substitution of electronically controlled flight-simulation equipment for flight tests.
Flight and control characteristics evaluated. Report describes simulated flight tests to evaluate handling qualities and flight characteristics of Grumman Design 698 aircraft, vertical and short takeoff and landing (V/STOL) aircraft.
An experiment has been conducted to ascertain the usefulness of helicopter pilot speech controls and their effect on time-sharing performance, under the impetus of multiple-resource theories of attention which predict that time-sharing should be more efficient with mixed manual and speech controls than with all-manual ones. The test simulation involved an advanced, single-pilot scout/attack helicopter. Performance and subjective workload levels obtained supported the claimed utility of speech recognition-based controls; specifically, time-sharing performance was improved while preparing a data-burst transmission of information during helicopter hover.
Theories and tests for incorporating piezoelectric pushers as actuator devices for active vibration control are discussed. It started from a simple model with the assumption of ideal pusher characteristics and progressed to electromechanical models with nonideal pushers. Effects on system stability due to the nonideal characteristics of piezoelectric pushers and other elements in the control loop were investigated.
Foam multilayer insulation (FMLI), a reusable thermal control system (TCS), was evaluated in a simulated orbit hold environment on a test tank of 3.0 ft diameter, 5.6 ft length, and 34.5 cu ft volume. The TCS consisted of a 0.44-inch thick foam and a 16-layer (17 sheet) MLI blanket attached to the tank barrel and lower bulkhead, with the upper bulkhead covered with a 2.7-inch foam and a 31-layer (32 sheets) MLI blanket. Average insulation heating rates during orbit hold simulations ranged from 10.5 to 28.1 Btu/hr for warm boundary temperatures from 300 to 460 R, respectively. These rates corresponded to liquid losses of 0.9 and 2.3 percent of the tank's volume per day. This liquid loss rate would be significantly reduced for full size vehicle tanks due to the decreased surface area-to-volume ratio as compared to the test tank.
The continued presence and use of silicones on spacecraft in low Earth orbit (LEO) has been found to cause the deposition of contaminant films on surfaces which are also exposed to atomic oxygen. The composition and optical properties of the resulting SiO(x)- based (where x is near 2) contaminant films may be dependent upon the relative rates of arrival of atomic oxygen, silicone contaminant and hydrocarbons. This paper presents results of in-space silicone contamination tests, ground laboratory simulation tests and analytical modeling to identify controlling processes that affect contaminant characteristics.
The free-piston Stirling power convertor is being considered as an advanced power conversion technology to be used for future NASA deep space missions requiring long life radioisotope power systems. This technology has a conversion efficiency of over 25%, which is significantly higher than the efficiency of the Radioisotope Thermal-electric Generators (RTG) now in use. The NASA Glenn Research Center has long been recognized as a leader in Stirling technology and is responsible for the development of advanced technologies that are intended to significantly improve key characteristics of the Stirling convertor. The advanced technologies identified for development also consider the requirements of potential future missions and the new capabilities that have become available in the associated technical areas. One of the key areas identified for technology development is the engine controller. To support this activity, an advanced controller is being developed for the Stirling power convertor. This controller utilizes active power factor correction electronics and microcontroller-based controls. The object of this paper is to present an overview of the advanced controller concept with modeling, simulation and hardware test data.
The control automation and interaction paradigm (e.g., manual, autopilot, flight management system) used on virtually all large highly automated aircraft has long been an exemplar of breakdowns in human factors and human-centered design. An alternative paradigm is the Haptic Flight Control System (HFCS) that is part of NASA Langley Research Center s Naturalistic Flight Deck Concept. The HFCS uses only stick and throttle for easily and intuitively controlling the actual flight of the aircraft without losing any of the efficiency and operational benefits of the current paradigm. Initial prototypes of the HFCS are being evaluated and this paper describes one such evaluation. In this evaluation we examined claims regarding improved situation awareness, appropriate workload, graceful degradation, and improved pilot acceptance. Twenty-four instrument-rated pilots were instructed to plan and fly four different flights in a fictitious airspace using a moderate fidelity desktop simulation. Three different flight control paradigms were tested: Manual control, Full Automation control, and a simplified version of the HFCS. Dependent variables included both subjective (questionnaire) and objective (SAGAT) measures of situation awareness, workload (NASA-TLX), secondary task performance, time to recognize automation failures, and pilot preference (questionnaire). The results showed a statistically significant advantage for the HFCS in a number of measures. Results that were not statistically significant still favored the HFCS. The results suggest that the HFCS does offer an attractive and viable alternative to the tactical components of today s FMS/autopilot control system. The paper describes further studies that are planned to continue to evaluate the HFCS.
As part of the Nuclear Systems Office Fission Surface Power Technology Demonstration Unit (TDU) project, a reactor simulator test loop (RxSim) was design & built to perform integrated testing of the TDU components. In particular, the objectives of RxSim testing was to verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. In addition, it was decided to include a thermal test of a cold trap purification design and a pump performance test at pump voltages up to 150 V since the targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V. This paper summarizes RxSim testing. The gas and vacuum ground support test equipment performed effectively in NaK fill, loop pressurization, and NaK drain operations. The instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. The cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained which was lower than the predicted 750 K but 156 K higher than the cold temperature indicating the design provided some heat regeneration. The annular linear induction pump (ALIP) tested was able to produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz. Keywords: fission, space power, nuclear, liquid metal, NaK.
OBJECTIVE: Integrated testing of the TDU components TESTING SUMMARY: a) Verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. b) Thermal test heat regeneration design aspect of a cold trap purification filter. c) Pump performance test at pump voltages up to 150 V (targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V). TESTING HIGHLIGHTS: a) Gas and vacuum ground support test equipment performed effectively for NaK fill, loop pressurization, and NaK drain operations. b) Instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. c) Cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained which was lower than the predicted 750 K but 156 K higher than the cold temperature indicating the design provided some heat regeneration. d) ALIP produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz.
As part of the Nuclear Systems Office Fission Surface Power Technology Demonstration Unit (TDU) project, a reactor simulator test loop (RxSim) was design & built to perform integrated testing of the TDU components. In particular, the objectives of RxSim testing was to verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. In addition, it was decided to include a thermal test of a cold trap purification design and a pump performance test at pump voltages up to 150 V since the targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V. This paper summarizes RxSim testing. The gas and vacuum ground support test equipment performed effectively in NaK fill, loop pressurization, and NaK drain operations. The instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. The cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained which was lower than the predicted 750 K but 156 K higher than the cold temperature indicating the design provided some heat regeneration. The annular linear induction pump (ALIP) tested was able to produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz.