Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Annual Waste Minimization Summary Report, Calendar Year 2010, U.S. Environmental Protection Agency Identification No. NV3890090001

This report summarizes the waste minimization efforts undertaken by National Security TechnoIogies, LLC, for the U. S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO), during calendar year 2010. The NNSA/NSO Pollution Prevention Program establishes a process to reduce the volume and toxicity of waste generated by NNSA/NSO activities and ensures that proposed methods of treatment, storage, and/or disposal of waste minimize potential threats to human health and the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preparation of ortho-para ratio controlled D{sub 2} gas for muon-catalyzed fusion

A negative muon in hydrogen targets, e.g., D{sub 2} or D-T mixture, can catalyze nuclear fusions following a series of atomic processes involving muonic hydrogen molecular formation (muon-catalyzed fusion, {mu}CF). The ortho-para state of D{sub 2} is a crucial parameter not only for enhancing the fusion rate but also to precisely investigate various muonic atom processes. We have developed a system for controlling and measuring the ortho-para ratio of D{sub 2} gas for {mu}CF experiments. We successfully collected para-enriched D{sub 2} without using liquid-hydrogen coolant. Ortho-enriched D{sub 2} was also obtained by using a catalytic conversion method with a mixture of chromium oxide and alumina. The ortho-para ratio of D{sub 2} gas was measured with a compact Raman spectroscopy system. We produced large volume (5-30 l at STP), high-purity (less than ppm high-Z contaminant) D{sub 2} targets with a wide range of ortho-para ratios (ortho 20%-99%). By using the ortho-para controlled D{sub 2} in {mu}CF experiments, we observed the dependence of {mu}CF phenomena on the ortho-para ratio.

74 ATOMIC AND MOLECULAR PHYSICS↗

Quantitative analysis of [ 18 F]FDDNP PET using subcortical white matter as reference region

Purpose: Subcortical white matter is known to be relatively unaffected by amyloid deposition in Alzheimer’s disease (AD). We investigated the use of subcortical white matter as a reference region to quantify [ 18 F]FDDNP binding in the human brain. Methods: Dynamic [ 18 F]FDDNP PET studies were performed on 7 control subjects and 12 AD patients. Population efflux rate constants (k' 2 ) from subcortical white matter (centrum semiovale) and cerebellar cortex were derived by a simplified reference tissue modeling approach incorporating physiological constraints. Regional distribution volume ratio (DVR) estimates were derived using Logan and simplified reference tissue approaches, with either subcortical white matter or cerebellum as reference input. Discriminant analysis with cross-validation was performed to classify control subjects and AD patients. Results The population estimates of k' 2 in subcortical white matter did not differ significantly between control subjects and AD patients but the variability of individual estimates of k' 2 determined in white matter was lower than that in cerebellum. Logan DVR showed dependence on the efflux rate constant in white matter. The DVR estimates in the frontal, parietal, posterior cingulate, and temporal cortices were significantly higher in the AD group (p<0.01). Incorporating all these regional DVR estimates as predictor variables in discriminant analysis yielded accurate classification of control subjects and AD patients with high sensitivity and specificity, and the results agreed well with those using the cerebellum as the reference region. Conclusion: Subcortical white matter can be used as a reference region for quantitative analysis of [ 18 F]FDDNP with the Logan method which allows more accurate and less biased binding estimates, but a population efflux rate constant has to be determined a priori.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-T-574: Novel Chance-Constrained Optimization in Intensity-Modulated Proton Therapy Planning to Account for Range and Patient Setup Uncertainties

Purpose: We propose to apply a probabilistic framework, namely chanceconstrained optimization, in the intensity-modulated proton therapy (IMPT) planning subject to range and patient setup uncertainties. The purpose is to hedge against the influence of uncertainties and improve robustness of treatment plans. Methods: IMPT plans were generated for a typical prostate patient. Nine dose distributions are computed — the nominal one and one each for ±5mm setup uncertainties along three cardinal axes and for ±3.5% range uncertainty. These nine dose distributions are supplied to the solver CPLEX as chance constraints to explicitly control plan robustness under these representative uncertainty scenarios with certain probability. This probability is determined by the tolerance level. We make the chance-constrained model tractable by converting it to a mixed integer optimization problem. The quality of plans derived from this method is evaluated using dose-volume histogram (DVH) indices such as tumor dose homogeneity (D5% – D95%) and coverage (D95%) and normal tissue sparing like V70 of rectum, V65, and V40 of bladder. We also compare the results from this novel method with the conventional PTV-based method to further demonstrate its effectiveness Results: Our model can yield clinically acceptable plans within 50 seconds. The chance-constrained optimization produces IMPT plans with comparable target coverage, better target dose homogeneity, and better normal tissue sparing compared to the PTV-based optimization [D95% CTV: 67.9 vs 68.7 (Gy), D5% – D95% CTV: 11.9 vs 18 (Gy), V70 rectum: 0.0 % vs 0.33%, V65 bladder: 2.17% vs 9.33%, V40 bladder: 8.83% vs 21.83%]. It also simultaneously makes the plan more robust [Width of DVH band at D50%: 2.0 vs 10.0 (Gy)]. The tolerance level may be varied to control the tradeoff between plan robustness and quality. Conclusion: The chance-constrained optimization generates superior IMPT plan compared to the PTV-based optimization with explicit control of plan robustness. NIH/NCI K25CA168984, Eagles Cancer Research Career Development, The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, Mayo ASU Seed Grant, and The Kemper Marley Foundation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Escalated Intensity-Modulated Radiotherapy Is Feasible and May Improve Locoregional Control and Laryngeal Preservation in Laryngo-Hypopharyngeal Cancers

Purpose: To determine the safety and outcomes of induction chemotherapy followed by dose-escalated intensity-modulated radiotherapy (IMRT) with concomitant chemotherapy in locally advanced squamous cell cancer of the larynx and hypopharynx (LA-SCCL/H). Methods and Materials: A sequential cohort Phase I/II trial design was used to evaluate moderate acceleration and dose escalation. Patients with LA-SCCL/H received IMRT at two dose levels (DL): DL1, 63 Gy/28 fractions (Fx) to planning target volume 1 (PTV1) and 51.8 Gy/28 Fx to PTV2; DL2, 67.2 Gy/28 Fx and 56 Gy/28 Fx to PTV1 and PTV2, respectively. Patients received induction cisplatin/5-fluorouracil and concomitant cisplatin. Acute and late toxicities and tumor control rates were recorded. Results: Between September 2002 and January 2008, 60 patients (29 DL1, 31 DL2) with Stage III (41% DL1, 52% DL2) and Stage IV (52% DL1, 48% DL2) disease were recruited. Median (range) follow-up for DL1 was 51.2 (12.1-77.3) months and for DL2 was 36.2 (4.2-63.3) months. Acute Grade 3 (G3) dysphagia was higher in DL2 (87% DL2 vs. 59% DL1), but other toxicities were equivalent. One patient in DL1 required dilatation of a pharyngeal stricture (G3 dysphagia). In DL2, 2 patients developed benign pharyngeal strictures at 1 year. One underwent a laryngo-pharyngectomy and the other a dilatation. No other G3/G4 toxicities were reported. Overall complete response was 79% (DL1) and 84% (DL2). Two-year locoregional progression-free survival rates were 64.2% (95% confidence interval, 43.5-78.9%) in DL1 and 78.4% (58.1-89.7%) in DL2. Two-year laryngeal preservation rates were 88.7% (68.5-96.3%) in DL1 and 96.4% (77.7-99.5%) in DL2. Conclusions: At a mean follow-up of 36 months, dose-escalated chemotherapy-IMRT at DL2 has so far been safe to deliver. In this study, DL2 delivered high rates of locoregional control, progression-free survival, and organ preservation and has been selected as the experimental arm in a Cancer Research UK Phase III study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Regeneration of Tissues and Organs Using Autologous Cells

The Joint Commission for Health Care Organizations recently declared the shortage of transplantable organs and tissues a public health crisis. As such, there is about one death every 30 seconds due to organ failure. Complications and rejection are still significant albeit underappreciated problems. It is often overlooked that organ transplantation results in the patient being placed on an immune suppression regimen that will ultimate shorten their life span. Patients facing reconstruction often find that surgery is difficult or impossible due to the shortage of healthy autologous tissue. In many cases, autografting is a compromise between the condition and the cure that can result in substantial diminution of quality of life. The national cost of caring for persons who might benefit from engineered tissues or organs has reached $600 billion annually. Autologous tissue technologies have been developed as an alternative to transplantation or reconstructive surgery. Autologous tissues derived from the patient's own cells are capable of correcting numerous pathologies and injuries. The use of autologous cells eliminates the risks of rejection and immunological reactions, drastically reduces the time that patients must wait for lifesaving surgery, and negates the need for autologous tissue harvest, thereby eliminating the associated morbidities. In fact, the use of autologous tissues to create functional organs is one of the most important and groundbreaking steps ever taken in medicine. Although the basic premise of creating tissues in the laboratory has progressed dramatically, only a limited number of tissue developments have reached the patients to date. This is due, in part, to the several major technological challenges that require solutions. To that end, we have been in pursuit of more efficient ways to expand cells in vitro, methods to improve vascular support so that relevant volumes of engineered tissues can be grown, and constructs that can mimic the native tissue environment to ensure tissue integration, maturation, and survival. Other long-term benefits of this research are likely to be cell-based drug delivery mechanisms, intelligent biomaterials, bio-nano technologies, as well as controlled delivery using advances in materials science. The major challenges to the goal of producing tissues and organs for transplantation and reconstruction are three-fold and will form the basis for the goals of this research. These include (1) Identifying sources of autologous cells and developing methods to expand them in large number in vitro, (2) Providing vascular support for growing constructs, and (3) Developing biomaterials and bioreactor systems that mimic the native tissue environment.

36 MATERIALS SCIENCE↗

A Versatile Microfluidic Device for Automating Synthetic Biology

New microbes are being engineered that contain the genetic circuitry, metabolic pathways, and other cellular functions required for a wide range of applications such as producing biofuels, biobased chemicals, and pharmaceuticals. Although currently available tools are useful in improving the synthetic biology process, further improvements in physical automation would help to lower the barrier of entry into this field. We present an innovative microfluidic platform for assembling DNA fragments with 10× lower volumes (compared to that of current microfluidic platforms) and with integrated region-specific temperature control and on-chip transformation. Integration of these steps minimizes the loss of reagents and products compared to that with conventional methods, which require multiple pipetting steps. For assembling DNA fragments, we implemented three commonly used DNA assembly protocols on our microfluidic device: Golden Gate assembly, Gibson assembly, and yeast assembly (i.e., TAR cloning, DNA Assembler). Here, we demonstrate the utility of these methods by assembling two combinatorial libraries of 16 plasmids each. Each DNA plasmid is transformed into Escherichia coli or Saccharomyces cerevisiae using on-chip electroporation and further sequenced to verify the assembly. Lastly, we anticipate that this platform will enable new research that can integrate this automated microfluidic platform to generate large combinatorial libraries of plasmids and will help to expedite the overall synthetic biology process.

59 BASIC BIOLOGICAL SCIENCES↗

Non-Aqueous Electrochemical Fluorination of Used Nuclear Fuel as an Advanced Separation Process

Development of efficient and environmentally benign methods to reprocess used nuclear fuel (UNF) will enable technologies for a nuclear renaissance. Electrochemical and fluorination methods for reprocessing UNF have been proposed, but combinations of electrochemical and fluorination methods have not been investigated. Electrochemical fluorination may reduce waste volumes compared to the main large-scale aqueous methods for processing used nuclear fuel. A non-aqueous electrochemical fluorination reprocessing method has been developed and demonstrated that enables gas phase uranium recovery while allowing for potential control of the reaction using a single process. Thermodynamic modeling showed a galvanic reaction between UNF and a fluorinating agent, such as NF 3 , in a molten fluoride electrolyte was possible and could selectively fluorinate U to UF 6 . To verify the model results, a reactor system for electrochemical fluorination was constructed along with vessels for product collection and analysis. Initial trials of the electrochemical reaction were performed and characterized by several electrochemical methods. The electrochemical oxidation of U using NF 3 as an oxidizing agent was demonstrated and UF 6 as a reaction product was detected.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Subplane Decusping for BWRs in MPACT

Control blade cusping can introduce significant error in boiling water reactor (BWR) calculations with MPACT when blade tips fall partway within an axial method of characteristics (MOC) plane, requiring homogenization of controlled and uncontrolled regions. This work implements subplane decusping for BWRs in MPACT by enabling BWR-compatible subplane coarse mesh finite difference (CMFD) and extending the existing decusping framework to represent between-assembly control blades that insert from the bottom of the core. The method resolves axial heterogeneity on a refined subplane mesh in the low-order solve and uses the resulting subplane flux shape to form flux-volume homogenized transport cross sections for the partially rodded MOC plane. The capability is evaluated using a single physics General Electric (GE)-14 assembly and a multiphysics Peach Bottom Unit 2 Type 1 assembly (PB2T1A) with thermal hydraulic feedback. In both cases, coarse axial meshes with and without subplane decusping are compared against fine mesh reference solutions over the full range of blade withdrawal positions. Subplane decusping reduces maximum/average eigenvalue errors from 3,369/220 pcm to 303/36 pcm for GE-14 and from 6,689/585 pcm to 1,582/109 pcm for PB2T1A. Additionally, it reduces pin power root mean square errors from 5.2%/0.8% to 1.8%/0.2% for GE-14 and from 6.9%/0.6% to 2.3%/0.1% for PB2T1A. These results demonstrate an effective, practical correction for BWR blade cusping in VERA-MPACT.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improving chiral property of domain-wall fermions by reweighting method

The reweighting method is applied to improve the chiral property of domain-wall fermions. One way to achieve this is to enlarge L{sub s}, the size of fifth dimension, which controls the size of the induced chiral symmetry breaking. While this is a type of reweighting method for shifting the action parameter, it seems non-trivial since this reweighting means change of the five dimensional lattice volume. In this report, we address issues in this direction of reweighting and evaluate its effectiveness.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluating Variable Switching and Flash Methods in Modeling Carbon Sequestration in Deep Geologic Formations using PFLOTRAN

PFLOTRAN a massively parallel computer code for modeling coupled hydro-thermal-chemical processes in variably saturated, non-isothermal porous media is applied to sequestration of supercritical CO{sub 2} in deep geologic formations. Two different methods of solution to the governing partial differential equations are implemented referred to as variable switching and the flash approach. Variable switching entails choosing the independent variables according to the set of phases present in a control volume, whereas in the flash approach a persistent set of variables are used through the calculation. The features and performance of the two approaches are described and contrasted in regard to stability and convergence, flexibility of choice of solver, and scaling behavior.

58 GEOSCIENCES↗

Stochastic finite volume method for uncertainty quantification of transient flow in gas pipeline networks

We develop a weakly intrusive framework to simulate the propagation of uncertainty in solutions of generic hyperbolic partial differential equation systems on graph-connected domains with nodal coupling and boundary conditions. The method is based on the Stochastic Finite Volume (SFV) approach and can be applied for uncertainty quantification (UQ) of the dynamical state of fluid flow over actuated transport networks. The numerical scheme has specific advantages for modeling intertemporal uncertainty in time-varying boundary parameters, which cannot be characterized by strict upper and lower (interval) bounds. We describe the scheme for a single pipe, and then formulate the controlled junction Riemann problem (JRP) that enables the extension to general network structures. In conclusion, we demonstrate the method's capabilities and performance characteristics using a standard benchmark test network.

97 MATHEMATICS AND COMPUTING↗

Communication: Control of chemical reactions using electric field gradients

We examine theoretically a new idea for spatial and temporal control of chemical reactions. When chemical reactions take place in a mixture of solvents, an external electric field can alter the local mixture composition, thereby accelerating or decelerating the rate of reaction. The spatial distribution of electric field strength can be non-trivial and depends on the arrangement of the electrodes producing it. In the absence of electric field, the mixture is homogeneous and the reaction takes place uniformly in the reactor volume. When an electric field is applied, the solvents separate and the reactants are concentrated in the same phase or separate to different phases, depending on their relative miscibility in the solvents, and this can have a large effect on the kinetics of the reaction. This method could provide an alternative way to control runaway reactions and to increase the reaction rate without using catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

System and method for in situ volumetric sensing of 3D cure state of resin being used in an additive manufacturing system

An in situ cure monitoring control system for use with a volumetric three dimensional (3D) printing system, wherein the volumetric 3D system includes a container defining a build volume, the container includes a photocurable resist used for making a 3D part, and the resist is responsive to an optical curing beam from a light source, which is controlled by a controller, and which is passed through the resist. The cure monitoring control system includes an optical signal source which generates optical signals having a wavelength selected in relation to a characteristic of the resist, and directed to pass through the build volume. A detector detects the optical signals and generates output signals in accordance therewith. Software monitors the output signals and uses the output signals to modify the curing beam to help optimize curing of the resist.

Panas, Robert Matthew↗

Assessment of Uncertainties in Treatment Planning for Scanned Ion Beam Therapy of Moving Tumors

Purpose: To provide methods for quantification of uncertainties in 4-dimensional (4D) treatment during treatment planning. Methods and Materials: Uncertainty information was generated by multiple 4D treatment simulations with varying parameters. Sampled data were analyzed using uncertainty visualization methods that have been added to common treatment plan evaluation methods (eg, dose-volume histogram and dose distribution analysis). To illustrate the potential of the introduced methods, uncertainty analysis was completed for a single lung cancer case using 3 motion mitigation techniques: gating, slice-by-slice rescanning, and breath-controlled rescanning. Results: By repeating 4D dose calculations with varying parameters, we were able to show local uncertainties in dose distributions and to evaluate the stability of treatment setups. The new methods were found suitable for uncertainty evaluation in 4D treatment planning of moving tumors. Calculation time of the uncertainty base data was time consuming but contrivable overnight. Conclusions: Uncertainty analysis and visualization for 4D treatment planning provide an important tool in the decision process for an optimal treatment approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mingus Discontinuous Multiphysics

Mingus provides hybrid coupled local/non-local mechanics analysis capabilities that extend several traditional methods to applications with inherent discontinuities. Its primary features include adaptations of solid mechanics, fluid dynamics and digital image correlation that naturally accommodate dijointed data or irregular solution fields by assimilating a variety of discretizations (such as control volume finite elements, peridynamics and meshless control point clouds). The goal of this software is to provide an analysis framework form multiphysics engineering problems with an integrated image correlation capability that can be used for experimental validation and model

Turner, Dan↗

Optimization of Operating Parameters for Minimum Mechanical Specific Energy in Drilling

Efficiency in drilling is measured by Mechanical Specific Energy (MSE). MSE is the measure of the amount of energy input required to remove a unit volume of rock, expressed in units of energy input divided by volume removed. It can be expressed mathematically in terms of controllable parameters; Weight on Bit, Torque, Rate of Penetration, and RPM. It is well documented that minimizing MSE by optimizing controllable factors results in maximum Rate of Penetration. Current methods for computing MSE make it possible to minimize MSE in the field only through a trial-and-error process. This work makes it possible to compute the optimum drilling parameters that result in minimum MSE. The parameters that have been traditionally used to compute MSE are interdependent. Mathematical relationships between the parameters were established, and the conventional MSE equation was rewritten in terms of a single parameter, Weight on Bit, establishing a form that can be minimized mathematically. Once the optimum Weight on Bit was determined, the interdependent relationship that Weight on Bit has with Torque and Penetration per Revolution was used to determine optimum values for those parameters for a given drilling situation. The improved method was validated through laboratory experimentation and analysis of published data. Two rock types were subjected to four treatments each, and drilled in a controlled laboratory environment. The method was applied in each case, and the optimum parameters for minimum MSE were computed. The method demonstrated an accurate means to determine optimum drilling parameters of Weight on Bit, Torque, and Penetration per Revolution. A unique application of micro-cracking is also presented, which demonstrates that rock failure ahead of the bit is related to axial force more than to rotation speed.

42 ENGINEERING↗