Search NASA⌕ Search

SEARCH · Search NASA

Results for “converter control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust Predictive Control for Modular Solid-State Transformer With Reduced DC Link and Parameter Mismatch

This paper presents the analysis and implementation of a predictive control method for dc-link regulation and voltage balance in a cascaded modular reduced dc-link solid-state transformer (SST). Passive components like bulky dc links limit the power density of power converters, especially medium-voltage (MV) SST. Reduced dc-link or low-inertia converters can dramatically reduce the size, cost, and weight by tolerating larger dc-link ripples and improve the reliability with electrolytic capacitor-less dc link. However, a small dc link leads to tight coupling between the input and the output stages, which is a challenge for control design. In stacked low-inertia converters (SLIC), the low-inertia converter modules are stacked for MV applications, resulting in coupling between the modules and making the control more challenging. A new model predictive control method which can achieve deadbeat regulation on the dc link without weighting factors has been proposed to address this novel problem. This paper focuses on analyzing the condition of the low-inertia dc link up to 80% ripple, the robustness of the control under parameter mismatches, high-order terms, and important implementation issues such as model-based sampling and computation delay compensation. Significantly, the high-order terms are introduced because of the large dc-link ripple. These high-order terms are unique to the SLIC and negligible in conventional high-inertia converters. A discrete-time large-signal model is built to capture the dc-link’s nonlinear dynamics, and the eigenvalues of a small-signal Jacobian matrix are analyzed with Floquet theory to evaluate stability, using the modular soft-switching solid-state transformer (M-S4T) as an example of the SLIC. Simulation and experimental results of an MVDC M-S4T verify the analysis and the predictive control method. Finally, the general application of the predictive control to low-inertia converters is compared against a conventional PI controller using a reduced dc-link active-front-end (AFE) rectifier as an example.

14 SOLAR ENERGY↗

Spontaneous Reorganization of DNA-Based Polymers in Higher Ordered Structures Fueled by RNA

We demonstrate a strategy that allows for the spontaneous reconfiguration of self-assembled DNA polymers exploiting RNA as chemical fuel. To do this, we have rationally designed orthogonally addressable DNA building blocks that can be transiently deactivated by RNA fuels and subtracted temporarily from participation in the self-assembly process. Through a fine modulation of the rate at which the building blocks are reactivated we can carefully control the final composition of the polymer and convert a disordered polymer in a higher order polymer, which is disfavored from a thermodynamic point of view. We measure the dynamic reconfiguration via fluorescent signals and confocal microscopy, and we derive a kinetic model that captures the experimental results. Our approach suggests a novel route toward the development of biomolecular materials in which engineered chemical reactions support the autonomous spatial reorganization of multiple components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The role of Tyr34 in proton coupled electron transfer and product inhibition of manganese superoxide dismutase

Human manganese superoxide dismutase (MnSOD) plays a crucial role in controlling levels of reactive oxygen species (ROS) by converting superoxide (O$^{•–}_{2}$) to molecular oxygen (O 2 ) and hydrogen peroxide (H 2 O 2 ) with proton-coupled electron transfers (PCETs). A key catalytic residue, Tyr34, determines the activity of human MnSOD and also becomes post-translationally inactivated by nitration in various diseases associated with mitochondrial dysfunction. Tyr34 has an unusual pK a due to its proximity to the Mn metal and undergoes cyclic deprotonation and protonation events to promote the electron transfers of MnSOD. Neutron diffraction, X-ray spectroscopy, and quantum chemistry calculations in oxidized, reduced and product inhibited enzymatic states shed light on the role of Tyr34 in MnSOD catalysis. The data identify the contributions of Tyr34 in MnSOD activity that support mitochondrial function and give a thorough characterization of how a single tyrosine modulates PCET catalysis. Product inhibition occurs by an associative displacement mechanism.

60 APPLIED LIFE SCIENCES↗

Design and Analysis of a 200 kW Dynamic Wireless Charging System for Electric Vehicles

Dynamic wireless charging of electric vehicles can significantly alleviate or eliminate range anxiety while reducing the required on-board battery capacity. To achieve an electric vehicle charging balance with minimal infrastructure costs, power transfer levels around 200 kW are required. In this paper, a system architecture with a modularized power electronics and optimized power transfer couplers was adopted to enable efficient power transfer. A DC/DC converter was used for secondary-side charging control of the battery. The system performance was validated in an experimental setup at 120 kW with 91.31% efficiency from the DC input on the primary side to the vehicle battery.

Xue, Lincoln↗

Power Router for Distributing Solar in Communities (Solar Prize): Cooperative Research and Development, CRADA Number CRD-20-16809 (Final Report)

The American Made Solar Prize is a prize competition from the U.S. Department of Energy (DOE) that is designed to revitalize U.S. solar manufacturing. The competition aims to support the growth of U.S. solar manufacturing and reenergize American energy innovation by tapping into American's competitive spirit and the nation's unparalleled innovation ecosystem leveraging national labs, incubators, facilities and more.

14 SOLAR ENERGY↗

Repurposing Inactive Oil and Gas Wells for Energy Storage: Maximizing the Potential Via Optimal Drivetrain Control: Preprint

In recent years, there has been a growing emphasis on utilizing energy storage to enhance grid resilience against disruptive events. While renewable energy supply continues to expand, gravity-based solutions like pumped hydro remain dominant in the commercial space. However, their geographical limitations constrain availability, scalability, and increase costs for co-locating solar and wind energy. An alternative approach proposes repurposing idle oil and gas wells located closer to existing grid infrastructure, offering a promising and cost-effective solution. This paper addresses the optimization and control of a regenerative drive system coupled to an interior permanent magnet synchronous machine in a 300-meter well with a 100-Newton weight. The study employs a dynamic MATLAB/Simulink model to simulate the operation of the electric drivetrain system during storage and discharge operations. The results demonstrate an initial round-trip efficiency of 85.9% for the electrical system alone and identify crucial factors for maximizing efficiency. The optimized operation and control of the electromechanical drivetrain system hold great potential for minimizing the levelized cost of storage while maximizing efficiency and revenue generation.

ENERGY STORAGE,ENGINEERING↗

Analysis of High Frequency AC Link Isolated Three Port Resonant Converter for UAV Applications

A high frequency AC link isolated three port semi-bridgeless resonant converter is analyzed for unmanned aerial vehicle (UAV) applications in this study. The proposed topology is established by replacing rectifier lover diodes with synchronous switches. A phase shifted pulse width modulation (PS-PWM) technique adjusts bi-directional power flow between ports. Proposed control technique provides high efficiency by reducing switching losses with zero voltage switching (ZVS) and zero current switching (ZCS) in a wide power range regulation. Compared to integrated PWM converters in a bi-directional mode, the proposed topology reduces the number of converter stages and allows centralized control at high operating frequency. Theoretical and experimental results demonstrate the feasibility and effectiveness of the proposed converter at a full power of 500 W in laboratory conditions.

Asa, Erdem↗

Wind turbine power phase control with DC collection bus for onshore/offshore windfarms

A DC bus collection system for a wind farm reduces the overall required number of converters and minimizes the energy storage system requirements. The DC bus collection system implements a power phasing control method between wind turbines that filters the variations and improves power quality. The phasing control method takes advantage of a novel power packet network concept with nonlinear power flow control design techniques that guarantees both stable and enhanced dynamic performance.

Weaver, Wayne W.↗

Controller Verification of a Smart-Grid Compatible 200 kHz Single-stage Photovoltaic Microinverter

This paper presents control system design, implementation, and experimental validation of a single-stage 400 W, 200 kHz solar photovoltaic (PV) microinverter using hardware-in-the-loop (HIL) and hardware testing. The selected circuit topology is based on a Gallium Nitride (GaN) direct-matrix based dual active bridge (DAB) converter with a low voltage active power decoupler (APD) circuit. Control performance is verified, smart-grid compatibility is tested, and circuit operation is confirmed. Controller HIL (CHIL) is shown to aid in a complex power electronics system design by 1) enabling detailed control development prior to hardware implementation, 2) expanding the use of automated testing, and 3) increasing confidence in control performance prior to prototype testing. Altogether, these factors make HIL a valuable tool in complex power electronic designs.

14 SOLAR ENERGY↗

Blackstart Capability and Survivability of Wind Turbines with Fully Rated Converters

We report the blackstart capability of wind turbines is critical for the recovery of wind-dominant power systems from blackouts. If wind power plants are not able to restore a power system, the incorporation of wind resources into electric grids could be limited by blackstart capability. This paper tackles this problem by setting forth a grid-forming controller for Type 4 wind turbines which employ fully rated power converters. To this end, we engineer two-axis anti-windup proportional-integral regulators that serve to ride through restoration disturbances. We also design an active protection system to prevent wind turbines from stalling during recovery from blackouts. We demonstrate in a high-fidelity simulation environment that Type 4 wind turbines with the developed controllers and protection subsystem can: (i) re-energize a notional wind-dominant grid; (ii) ride through asymmetrical faults; and (iii) survive low wind speed events.

17 WIND ENERGY↗

Converting from NIS to Redhat Identity Management

The Jefferson Lab (Jlab) accelerator controls network has transitioned to a new authentication and network service interface. The new system uses the Redhat Identity Manager (IdM) as a single integrating front end to the Lightweight Directory Access Protocol (LDAP) and a replacement for NIS and the Kerberos authentication service. This system allows for integration of access and authentication across Unix and Windows environments and across different Jlab computing environments, including across firewalls. The decision making process, conversion steps, issues and solutions will be discussed.

McGuckin, T. S.↗

Voltage Control Strategy for Energy Storage System in Sustainable Distribution System Operation

Due to the increasing penetration of distributed energy resources (DERs) required for the sustainable distribution system, new voltage control strategy is needed by utilities. Traditional voltage control strategy can not support the increasing number of DERs in a coordinated and scalable manner to meet the operational voltage regulation requirement. Supported by the power electronics converter, the energy storage system can provide fast, smooth, and flexible voltage control services. In this paper, an effective and easy to implement sensitivity-based voltage control strategy is developed for the energy storage system. The developed control strategy is validated using an industrial feeder data in Northwest Washington. The proposed strategy can mitigate the voltage unbalance issue, improve the voltage profile, and correct power factors while supporting sustainable distribution system operation.

Zhang, Yue (ORCID:0000000241469716)↗

Fast and fault-tolerant model predictive control of MMCs under selective harmonic elimination

Selective harmonic elimination (SHE) is a suitable pulse-width modulation (PWM) tech-nique for some applications of modular multilevel converters (MMC) with lower numberof semiconductor submodules (SM). However, SHE can make it difficult to control circu-lating currents in the MMC. Moreover, the MMC is vulnerable to SM switch failures thatreduce its output power magnitude and quality. This paper proposes a fault-tolerant modelpredictive control strategy for MMCs operating with SHE (FT SHE-MPC). The effects ofswitch failure on phase voltage waveforms are studied first. Then, a method is proposedto design the FT SHE waveform to preserve its harmonic performance. Next, the pro-posed FT SHE-MPC is designed to increase the capacitor voltages during an SM failure tomaintain the fundamental component of the faulty phase voltage and control the circulat-ing currents, maintaining balance among line voltages and the output power of the MMC.Additionally, the proposed method offers as much as 60% faster FT transition time and asmuch as 36% lower capacitor voltage ripple. The advantages of the proposed method areverified through offline and real-time simulation studies on a three-phase nine-level MMCin PSCAD/EMTDC software and RTDS.

42 ENGINEERING↗

Angular-spectral filtering of recoil protons for optimization of fast neutron imaging employing proton converters

Fast neutron imaging is an important capability for diverse applications such as inertial confinement fusion diagnostics, cargo security, nuclear nonproliferation and arms control, and industrial inspection. Traditional phosphor image plates can be enhanced for fast neutron imaging using hydrogenous plastic converters which allow fast neutrons to scatter off hydrogen nuclei to produce energetic protons that can be recorded by the image plate. However, protons emitted by image plates are not constrained in their emission angle, which contributes to the blur of the resulting image. Here, we investigate two methods that can alter the spatial extent of converted protons that deposit energy in the image plate: reducing the converter thickness, and introducing a proton filter between the plastic converter and image plate to reduce the contribution of lower-energy, off-axis protons to the image. Here we determine the optimal plastic converter thickness for maximizing the signal intensity to be 2–3 mm through Monte Carlo simulations, and we benchmark this result against experimental measurements with a deuterium-tritium (DT) neutron generator. Next, we evaluate the image smearing and signal loss for various converters to show that solely reducing the converter thickness has the expected effect of reducing the blur from proton image smearing of the sharpness of an edge recorded on the image plate at the cost of reducing the signal intensity. The use of a proton filter is shown to achieve a similar improvement of edge sharpness as reducing the converter thickness while also sacrificing the signal intensity. We conclude that the use of proton energy filtering can improve the sharpness of fast neutron images in situations where the converter thickness cannot be reduced below some practical minimum. For more intense neutron sources, the signal intensity is of less concern, and optimizing the resolution of the image plate and therefore of the imaging system could have greater value. In these applications, proton filters may allow for improved fast neutron imaging measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Control of Grid-Connected Multiport MV Power Electronics Energy Hub: Preprint

In this paper a new concept of multiport modular medium-voltage power electronics hub (M3PE-HUB) is introduced for future power grid. The goal for this project is to design, develop, and demonstrate foundational technologies and capabilities for multiport power electronics energy hubs that can serve as intelligent devices to coordinate and control several different sources and loads. In this paper, the architecture of the controller, the central controls, and its verification is presented.

controls↗

Stability-Constrained Learning for Frequency Regulation in Power Grids With Variable Inertia

The increasing penetration of converter-based renewable generation has resulted in faster frequency dynamics, and low and variable inertia. As a result, there is a need for frequency control methods that are able to stabilize a disturbance in the power system at timescales comparable to the fast converter dynamics. This paper proposes a combined linear and neural network controller for inverter-based primary frequency control that is stable at time-varying levels of inertia. We model the time-variance in inertia via a switched affine hybrid system model. We derive stability certificates for the proposed controller via a quadratic candidate Lyapunov function. We test the proposed control on a 12-bus 3-area test network, and compare its performance with a base case linear controller, optimized linear controller, and finite-horizon Linear Quadratic Regulator (LQR). Our proposed controller achieves faster mean settling time and over 50% reduction in average control cost across 100 inertia scenarios compared to the optimized linear controller. Unlike LQR which requires complete knowledge of the inertia trajectories and system dynamics over the entire control time horizon, our proposed controller is real-time tractable, and achieves comparable performance to LQR.

data-driven control↗