Search NASA⌕ Search

SEARCH · Search NASA

Results for “core sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

The Role of Gamma-ray Imaging in Performing Radiological Characterisation at the Magnox Storage Ponds at the Bradwell Decommissioning Site - 13628

A gamma-ray imaging device has been used to perform radiological characterisation work at the spent fuel ponds complex at the site of the Bradwell Magnox Power Station, which is currently undergoing accelerated decommissioning. The objective of using a gamma-ray imaging system was to independently verify previous radiological survey work and to evaluate the adequacy of the random distribution of the destructive core sampling which had been performed. In performing this work the gamma-ray imager clearly identified the exact locations of the sources of radiation that gave rise to the elevated gamma dose rates measured by conventional health physics surveys of the area. In addition, the gamma-ray imager was able to characterise each hotspot as being either dominated by Cs-137 or by Co-60. The gamma imaging survey was undertaken with a RadScan gamma imaging system deployed on the walkways which run along the lengths of the ponds; this enabled the whole imaging survey to be performed with minimal dose uptake, demonstrating the ALARP principle within decommissioning. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Removal of the Plutonium Recycle Test Reactor - 13031

The 309 Facility housed the Plutonium Recycle Test Reactor (PRTR), an operating test reactor in the 300 Area at Hanford, Washington. The reactor first went critical in 1960 and was originally used for experiments under the Hanford Site Plutonium Fuels Utilization Program. The facility was decontaminated and decommissioned in 1988-1989, and the facility was deactivated in 1994. The 309 facility was added to Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) response actions as established in an Interim Record of Decision (IROD) and Action Memorandum (AM). The IROD directs a remedial action for the 309 facility, associated waste sites, associated underground piping and contaminated soils resulting from past unplanned releases. The AM directs a removal action through physical demolition of the facility, including removal of the reactor. Both CERCLA actions are implemented in accordance with U.S. EPA approved Remedial Action Work Plan, and the Remedial Design Report / Remedial Action Report associated with the Hanford 300-FF-2 Operable Unit. The selected method for remedy was to conventionally demolish above grade structures including the easily distinguished containment vessel dome, remove the PRTR and a minimum of 300 mm (12 in) of shielding as a single 560 Ton unit, and conventionally demolish the below grade structure. Initial sample core drilling in the Bio-Shield for radiological surveys showed evidence that the Bio-Shield was of sound structure. Core drills for the separation process of the PRTR from the 309 structure began at the deck level and revealed substantial thermal degradation of at least the top 1.2 m (4LF) of Bio-Shield structure. The degraded structure combined with the original materials used in the Bio-Shield would not allow for a stable structure to be extracted. The water used in the core drilling process proved to erode the sand mixture of the Bio-Shield leaving the steel aggregate to act as ball bearings against the core drill bit. A redesign is being completed to extract the 309 PRTR and entire Bio-Shield structure together as one monolith weighing 1100 Ton by cutting structural concrete supports. In addition, the PRTR has hundreds of contaminated process tubes and pipes that have to be severed to allow for a uniformly flush fit with a lower lifting frame. Thirty-two 50 mm (2 in) core drills must be connected with thirty-two wire saw cuts to allow for lifting columns to be inserted. Then eight primary saw cuts must be completed to severe the PRTR from the 309 Facility. Once the weight of the PRTR is transferred to the lifting frame, then the PRTR may be lifted out of the facility. The critical lift will be executed using four 450 Ton strand jacks mounted on a 9 m (30 LF) tall mobile lifting frame that will allow the PRTR to be transported by eight 600 mm (24 in) Slide Shoes. The PRTR will then be placed on a twenty-four line, double wide, self powered Goldhofer for transfer to the onsite CERCLA Disposal Cell (ERDF Facility), approximately 33 km (20 miles) away. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Engineering scale demonstration of a prospective cast Stone process - 15584

A cementitious waste form is one of the alternatives being evaluated for Supplemental Immobilization of Hanford Low Activity Waste (LAW). Washington River Protection Solutions (WRPS) is collecting data on cementitious or pozzolanic waste forms such as Cast Stone. The goal of this project for WRPS is to obtain data on the performance of the Cast Stone waste form for immobilizing LAW. As part of the data package being assembled, an engineering-scale demonstration with non-radioactive simulants was performed at the Savannah River National Laboratory (SRNL) using the Scaled Continuous Processing Facility (SCPF) to fill a container with simulated Cast Stone grout. Legacy salt solution from previous Hanford salt waste testing was trimmed to resemble the average composition generated from the Hanford Tank Waste Operation Simulator (HTWOS) used in the screening tests. The dry blend materials, ordinary portland cement (OPC), Class F fly ash, and ground granulated blast furnace slag (GGBFS or BFS) were obtained from Lafarge North America in Pasco, WA. Over three days, the SCPF was used to fill a 6,056 liter (1600 gallon) container with simulated Cast Stone grout. The tank was instrumented with x-, y-, and z-axis thermocouples to monitor curing temperature and two formed core sampling vials. The target production rate was 5.7 L/min (1.5 gpm). This required a salt solution flow rate of approximately 3.78 L/min (1 gpm) and a premix feed rate of approximately 263 kh/h (580 lb/h). The final surface slope at a fill height of 100 cm was 2.5-3.8 cm across the 260 cm (8.5 ft) diameter tank. During processing, grout was collected from both the mixer discharge and the discharge into the tank. These samples were stored in a humid environment either in a closed box proximal to the tank or inside the laboratory. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

H-Canyon Ventilation System Exhaust Tunnel Inspection at the Savannah River Site - 18052

The Department of Energy (DOE) H-Canyon Facility at the Savannah River Site (SRS) is operated by Savannah River Nuclear Solutions (SRNS). The Facility Structural Integrity Program (SIP) performs periodic visual inspections to confirm the component is capable of performing its safety function. This Program provides the process to document the conditions of safety related structural systems and components, their damage mechanisms, and recommend repairs if required before there is impact on the safety envelope. The H-Canyon Exhaust Tunnel is part of the H-Canyon Exhaust Ventilation System and is periodically inspected under the Structural Integrity Program. The Tunnel performs a Safety Class passive design feature function that is available 100% of the time. The Tunnel directs Canyon process air from the Canyon to the Sand Filter System. The radiological and chemical airborne activity coupled with the physical configuration of the tunnel precludes a manned entry into the tunnel. Tunnel inspections have been performed using cameras on a stick, referred to as pole cameras prior to CY2003. Since CY2003, five camera equipped crawlers have been used with varying levels of inspection success. With each successive crawler inspection, expectations have increased to perform tasks beyond visual examinations. The 2017 crawler performed the visual inspection but also included improvements on crawler performance, such as testing the use of wireless capability and remediation of crawler travel route, to the addition of stationary cameras and lighting at key locations. The latest 2017 crawler successfully traveled the entire length of the tunnel between the Canyon and Sand Filter System for the second time since development, thus providing key visual data for the integrity program [2]. In addition, several access ports were installed in 2017 following the removal of concrete core samples that allow for new visual inspection of the Canyon Crossover tunnel, thus providing information for an area that was generally inaccessible for monitoring. Planning for the 2019 crawler inspection is underway with the expectations to improve upon inspection cameras and also introduce mapping technologies such as LIDAR. The challenge to obtain meaningful data from the remote inspections of a 60+ year operating Canyon Exhaust tunnel continues to be a complex endeavor requiring close coordination of multiple organizations, adherence to Conduct of Operations, Radiological Safety, Worker Safety, etc. principles as well as alignment with Facility Safety Basis requirements. This paper discusses the continuing improvements in inspection techniques and the challenges associated these inspections. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Subsurface Radionuclide Transport: Northeastern Negev Desert Vadose Zone Model Development - 19285

The overarching goal of the research presented is to build a subsurface radionuclide transport model for the vadose zone in the northeastern Negev desert of Israel, in order to assist in evaluating its suitability for radioactive waste subsurface disposal. The Negev desert provides a unique geologic setting because of its arid conditions, deep vadose zone and the layered stratigraphy consisting of sandstones, limestones, chalks, shales, marls, phosphorites, clays and cherts. These lithologies form intercalated layers of impermeable and permeable rocks, some with a high adsorption capacity for radionuclides. This paper consists of year one results of a joint US-Israeli collaboration to construct a generic radionuclide transport model of the vadose zone of the northeastern Negev region, Israel. The work aims to (1) evaluate potential vadose zone sites for a nuclear waste disposal site in Israel, and (2) promote the exchange of information and experience in subsurface waste siting and management. First year results include a) measured hydrogeologic rock properties for rock and core samples taken from the Negev desert, Israel, b) sorption and kinetic data for uranium U(VI) on phosphorite, chalk, sandstone and oil-shale lithologies, and c) an updated geologic, stratigraphic, and hydrologic subsurface framework for the northeastern Negev region. Preliminary results on uranium adsorption for key subsurface lithologies are encouraging in terms of the potential suitability of the Negev vadose zone to act as an efficient medium for the retardation of radionuclides. The findings provide impetus for continued experimentation and the development of a northeastern Negev subsurface flow and transport model. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Developing and Implementing New Waste Chemistry Controls for Hanford's Double-Shell Tanks - 20041

Waste chemistry controls for the Hanford double-shell tanks (DSTs) were established in the 1980's in response to tank failures caused by stress corrosion cracking (SCC) at the Savannah River Site (SRS). The controls were established based on a combination of SRS chemistry limits and corrosion testing results. Conditions in the Hanford DSTs have changed over time, with the temperature in the majority of the DSTs dropping below 50 deg. C. Testing indicated that the original chemistry control specification and SCC testing performed in 2010 did not protect against pitting corrosion mechanisms - what is believed to have caused the failure of tank 241-AY-102. New waste chemistry controls are necessary to protect the DSTs from both SCC and pitting corrosion. Savannah River National Laboratory (SRNL), with input from the Tank Integrity Expert Panel (TIEP) Corrosion Subgroup (CSG), performed a statistically based investigation of nitrate and halide ion induced pitting corrosion. The investigation was intended to develop a comprehensive waste chemistry envelope that minimizes the risk of both SCC and pitting caused by halide and nitrate ions. The waste chemistry envelope needed to be robust enough to address future waste retrieval and process changes which could significantly change the waste composition of the DSTs. The experimental design allowed the statistically significant ions and their effect on pitting corrosion to be determined. SRNL developed the 'pitting factor' which is an empirical relationship between the statistically significant inhibitive species (hydroxide, and nitrite), and pitting inducing species (nitrate, chloride, and fluoride). The coefficients are weighted factors that show the degree of influence the species have on the propensity for pitting. New waste chemistry control limits were recommended by SRNL, and concurred with by the TIEP CSG, that incorporated the pitting factor along with other limits. The controls developed to reduce the risk of pitting corrosion were evaluated to determine if they also protected against SCC. Hundreds of test results were reviewed and compared against the proposed limits. With the exception of one test result, instances where cracking was observed corresponded to chemistry that was outside of the proposed limits - indicating that the chemistry controls developed for pitting also adequately addressed SCC concerns. Existing tank composition estimates were evaluated against the new chemistry controls - three current tank chemistries are suspect, and may not meet the new chemistry control requirements. These included the interstitial liquid (liquid associated with solids) of DSTs 241-AN-102, 241-AN-106, 241-AN-107, and 241-AY-101. Measures are ongoing to evaluate the tanks with the suspect chemistry. These include varying combinations of: performing additional evaluations (history of use, modeling); DST specific laboratory testing; and, pursuing core samples of the DSTs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Borehole Disposal of Radioactive Waste in Israel - 20388

Israel is assessing borehole disposal of radioactive waste. With limited geological options for disposal, intermediate-depth borehole disposal is being considered in the arid Yamin Plain region of the northeastern Negev desert at depths of several hundred meters below ground surface in the vadose zone. Unlike deep borehole disposal of several kilometers, which relies on emplacement below the depth of recirculating groundwater, the safety case for intermediate-depth borehole disposal relies more on the aridity of the vadose zone, the robustness of the waste package, and the other engineered barriers (e.g., seals, backfill materials) in the disposal borehole. As a tradeoff, the shallower depth may allow the use of a larger diameter borehole than would be possible for a deeper borehole. To study the suitability of the Yamin Plain region for borehole disposal, a small-diameter characterization borehole is being planned to retrieve core samples and to better understand the vadose zone geomechanical and hydrogeochemical properties and percolation flux. The information from the characterization borehole will inform the safety case, and together with performance assessment analyses will help to identify key areas of uncertainty and guide future research and development activities aimed at demonstrating the feasibility of the intermediate-depth borehole disposal concept in Israel. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DEPLOYING TECHNOLOGY ADVANCEMENTS FOR CHARACTERIZING THE VADOSE ZONE IN SINGLE-SHELL TANK WASTE MANAGEMENT AREAS

As much as one million gallons of waste is believed to have leaked from tanks, pipelines or other equipment in the single-shell tank farm waste management areas (WMAs) within the 200 East and West areas of the U.S. Department of Energy's Hanford Site near Richland, Washington. Although some contamination has reached groundwater, most contamination still resides in the vadose zone. The magnitude ofthis problem requires new approaches for soil characterization if we are to understand the nature and extent of the contamination and take action to protect the enviromnent. Because of the complexity and expense of drilling traditional boreholes in contaminated soil, direct push characterization using a hydraulic hammer has been extensively employed. Direct push probe holes <3-inch diameter have been pushed to a maximum depth of 240 feet below ground surface in 200 East area. Previously gross gamma and moisture logging of these narrow probe holes was perfonned to identify the location of cesium-137 ({sup 137}Cs) (which has limited mobility in Hanford soil) and moisture peaks. Recently a bismuth germinate detector has been deployed for detecting and quantifying the spectrum of cobalt-60 ({sup 60}Co) (a more mobile contaminant), which provides additional information. The direct push system is configured to allow the collection ofmultiple soil core samples throughout the depth ofthe probe hole. The direct push unit has been used to place individual electrodes at a variety of depths as the probe hole is being decommissioned. These deep electrodes enable the use of soil resistivity measurement methods between surface and deep electrodes as-well-as between sets of deep electrodes. Initial testing of surface-to-deep electrode resistivity measurements in WMA C demonstrated significant improvement in defining the three dimensional extent of a contamination plume. A multiple-electrode string is presently being developed to further enhance the resolution of resistivity data. The combined use of direct push logging/sampling and soil resistivity measurement allows more extensive characterization of the large tank farm WMAs with less cost and time commitment than required by traditional methods. An additional tool is in the laboratory testing stage to support these investigations. A beta detection tool is being evaluated to determine if it might be deployed with the direct push unit to identify technetium-99 ({sup 99}Tc) contamination. {sup 99}Tc is a mobile, long-lived contaminant that is the major risk driver from tank waste contamination. A screening tool to locate {sup 99}Tc contamination is anticipated to further increase the cost-effectiveness ofvadose zone characterization efforts.

54 ENVIRONMENTAL SCIENCES↗

Applications of Hyporheic Zone Sampling for Assessing VOC Plume Engineered Remediation and Natural Attenuation Effectiveness - 20414

Determining the efficacy of engineered remedial actions and/or natural attenuation as an acceptable EPA Record of Decision (ROD) must address long-term temporal and spatial variability. Since final plume downslope destinations are aquifers and related surface streams and rivers, hyporheic zone sampling is essential. Comprehensive hyporheic sampling documents plume groundwater remediation prior to upwelling into stream benthic strata and natural attenuation within this dynamic zone itself. Our intensive sampling of the Savannah River Site (SRS) Chemical, Metals, and Pesticides (CMP) Pits VOC plume-fringe from 2005 to 2018 documented PCE natural attenuation and effectiveness of In Situ Thermal Treatment (ISTT). Most plume hyporheic upwelling was delimited to a 20 m inflow reach along Pen Branch. Our study utilized corroborative sampling methodologies: ambient hole-water grab samples: passive diffusion bags (PDB); and hole-core sediment samples to confirm station to station spatial and temporal trends. VOC hot spot detections were confirmed from both groundwater and soil core samples. VOC pathways through the Pen Branch hyporheic zone were assessed at hole-installation using sequential soil samples from augered cores and grab-samples of hole-bottom water. Longer term, composite water samples were collected from PDBs deployed for a minimum two-week equilibration period. Soil samples were collected from the 15 and 65 cm core levels in December 2017 and June 2018 at six stations. Additional core depths of 40 and 85 cm were sampled in June 2018 at the highest VOC station (5DB80). All samples were analyzed in an EPA certified lab by purge and trap GC-MS. Effectiveness of previous ISTT and soil vapor extraction (SVE) for this CMP Pits PCE plume, was clearly documented by significant downward trends in VOC at hyporheic zone stations prior to December 2015. Achieving final stage conversions of PCE daughter products to ethene and CO{sub 2} may be limited depending upon suitable interactions between hyporheic zone sediment morphology, hydrology, and redox conditions. Because declines in VOC daughter products at our hyporheic stations may also be caused by physical actions of dilution and dispersion rather than true biochemical dechlorination, full quantification of natural attenuation requires the use of compound-specific isotope ratio analysis (CSIA) and microbial 16S rRNA with qPCR. To assist these next-phase efforts, a natural attenuation index (NAI) was used to help produce quicker, more cost-effective decision making for locating CSIA and microbial sampling efforts. The NAI used natural logarithm transformed GC-MS results for station VOC degradation compounds versus VOC parent compounds. Wide differences were observed between stations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nutrient and carbon concentrations in dated soil cores at US-OWC Ameriflux wetland site (OWC NERR)

Soil cores were sampled at the Old Woman Creek (OWC) National Estuarine Research Reserve at the south shore of Lake Erie, near Huron, Ohio, USA. OWC is a temperate mineral soil marsh. We dated the soil cores using lead isotope analysis and measured the concentrations of carbon and nutrients (nitrogen, phosphorus) throughout the core depths. We analyzed 36 cores, sampled along three transects at areas of the wetland with different hydrological regimes. Each transect included three coring sites at different water depth categories (shallow, intermediate deep) with four core samples per coring site. The data can be used to determine the carbon sequestration rates and nutrient accumulation rates, at multiple locations throughout OWC wetland.Dataset, in csv format, with data variables in columns, and different cores and core depths slices in rows, includes results from 36 sediment cores (0-30 cm depth) taken at 9 locations (4 replicates at each location) along 3 gradients of water depth (shallow, intermediate, deep), each at a different hydrologic location (outflow, backflow, middle). At each depth slice within a core, we provide depth, date (using 210Pb), bulk density, and the concentrations of carbon, nitrogen, phosphorus, d13C, and d15N.

54 ENVIRONMENTAL SCIENCES↗

Use of XRF to characterize pre-Hanford orchards in the 100-OL-1 operable unit - 15717

Prior to 1943, Hanford site included several small towns with approximately 5,000 acres of orchards; at the time lead arsenate (PbHAsO{sub 4}) was the most commonly used pesticide. High concentration of lead and arsenic have been recorded where trees and stumps are still visible. Pre-Hanford orchards have been designated as 100-OL-1 Operable Unit. An Optimization study evaluated optimal counting time and position of the XRF from soils collected at the site. A Pilot Study included the evaluation of a field portable x-ray fluorescence (XRF) analyzer determining if performance results meet quality assurance criteria for cleanup. XRF has only previously been used as a screening tool. Four Decision Units (DUs) are to be analyzed: Ol-14. OL-32. OL-IU6-4 and OL-FR2-1. The DUs vary in size and have had distinct historic activities; such as 46.4 acres OL-14 having a military camp in the 1950's unlike OL-FR2-1 having been disturbed as it is near the F area reactor. Together the DUs provide an adequate representation of the Operable Unit. Screening criteria for lead (250 mg/kg) and arsenic (20 mg/kg). Six samples were collected ranging above, at, and below the screening criteria of 250 mg/kg for Pb and 20 mg/kg for As at the Decision Units OL-14 and OL-IU6-4, and labeled respectively. Samples were hand sieved, homogenized and placed in sample cups. Three replicates were prepared for each sample. Each sample cup was analyzed 3 times for 30 sec. A Standard Reference Material (SRM) was analyzed after every 20 readings. Three samples were selected for 15, 30, 45, 60, 90, 120, 150 and 180 second fixed and variable analysis. Two transects at OL-14, and one at OL-IU6-4 were created by selecting locations 90. around ground zero at distances of 0.5, 1, 2, 4, 8 and 12 feet (16 ft for OL-14). Locations were scanned in triplicate for 60 seconds each. 4 Decision Units spanning roughly 370 acres were chosen to represent 100-OL-1 Operable Unit. 40 locations within each DU were selected using Visual Sample Plan (VSP) with a random start and systematic grid pattern. Each location would be analyzed with 3 replicates and a 60 second count time. The Standard Reference Material (SRM) and blank are analyzed after every 20 counts to ensure accuracy. Data is extracted from XRF to be implemented in GIS for visual representation of site with 1943 and 2013 aerial imagery. Discussion/Conclusion: - XRF provided a good indication of precision and accuracy relative to ICP with a linear correlation R{sup 2} value higher than anticipated at .9735; - MDL proved the detection limit is significantly lower than the screening criteria; - When comparing results from the first 40 locations of OL-14 to the total 80 locations of OL-14, the same variability was seen; - We expect high concentrations of Pb and As to be where past orchards are present though this does not occur as all sites. Significance: - XRF is competent for decision making as values fall within ±20% ICP data; - The highest concentrations are not where expected, which may be an issue for sites outside of Hanford that have had more development; - The size of the DU does not affect the number of samples measured. Future Work: - Verification and validation of the XRF Data (QA/QC); - Revise conceptual site model; - Statistical evaluations to investigate: Estimation of variability in surface soils, appropriate size for DU, and sample size per DU; - Coordinating sample results through CORE; - Displaying sample results in PHOENIX (GIS tool)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The SDSS-IV extended Baryon Oscillation Spectroscopic Survey: Quasar target selection

As part of the Sloan Digital Sky Survey (SDSS) IV the extended Baryon Oscillation Spectroscopic Survey (eBOSS) will improve measurements of the cosmological distance scale by applying the Baryon Acoustic Oscillation (BAO) method to quasar samples. eBOSS will adopt two approaches to target quasars over 7500 deg{sup 2}. First, a “CORE” quasar sample will combine the optical selection in ugriz using a likelihood-based routine called XDQSOz, with a mid-IR-optical color cut. eBOSS CORE selection (to g < 22 or r < 22) should return ∼70 deg{sup −2} quasars at redshifts 0.9 < z < 2.2 and ∼7 deg{sup −2}z > 2.1 quasars. Second, a selection based on variability in multi-epoch imaging from the Palomar Transient Factory should recover an additional ∼3–4 deg{sup −2}z > 2.1 quasars to g < 22.5. A linear model of how imaging systematics affect target density recovers the angular distribution of eBOSS CORE quasars over 96.7% (76.7%) of the SDSS north (south) Galactic Cap area. The eBOSS CORE quasar sample should thus be sufficiently dense and homogeneous over 0.9 < z < 2.2 to yield the first few-percent-level BAO constraint near z-bar ∼1.5.eBOSS quasars at z > 2.1 will be used to improve BAO measurements in the Lyα Forest. Beyond its key cosmological goals, eBOSS should be the next-generation quasar survey, comprising >500,000 new quasars and >500,000 uniformly selected spectroscopically confirmed 0.9 < z < 2.2 quasars. At the conclusion of eBOSS, the SDSS will have provided unique spectra for more than 800,000 quasars.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of Saltstone Cores Taken from Saltstone Disposal Unit Cell 2A - 17350

At the Savannah River Site, low-level waste is immobilized in cementitious waste form known as saltstone. The saltstone Performance Assessment models the performance of the waste form and other aspects of the Saltstone Disposal Facility over ten thousand years after closure to better understand the transport history of radionuclides and other hazardous constituents in low-level waste. As part of ongoing Performance Assessment Maintenance, Savannah River Remediation (SRR), with Savannah River National Laboratory (SRNL), designed a sampling and analyses plan to correlate the properties of field-emplaced samples and samples processed and cured in the laboratory. The primary objectives of the Sampling and Analyses Plan are; (1) to demonstrate a correlation between the measured properties of laboratory-prepared, simulant samples (termed Sample Set 3), and the field-emplaced saltstone samples (termed Sample Set 9), and (2) to validate property values assumed for the Saltstone Disposal Facility (SDF) Performance Assessment modeling. The analysis and property data for Sample Set 9 (i.e. core samples extracted from Saltstone Disposal Unit Cell 2A (SDU2A)) are documented, and where applicable, the results are compared to the results for Sample Set 3. SRNL received, stored and analyzed the samples cored from SDU2A. This paper discusses the results of the SRNL analysis of the SDU2A samples as well as the simulant saltstone samples. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Soil Water Retention and Hydraulic Conductivity Data and Model at Pump House in East River Watershed, Colorado 2019-2024

This data package includes soil water retention and hydraulic conductivity data and model fitting results from measurements of ex-situ soil samples and in-situ soil sensors near Pump House at Mount Crested Butte in the East River Watershed. Soil water retention curves (SWRC) characterize soil water content as a function of soil water potential. SWRC depends on soil texture and pore structure and can be used to describe the constraints on biogeochemical processes in terms of soil water availability. In this data package, the sample identification follows the format ER-X-Y, where ER refers to East River, X is the location identifier, and Y is the depth identifier at the same X (shallow Y=1). Specifically, ER-PHS, ER-LMC, ER-LMF, and ER-SMN are associated with ecohydrology sites under the East-Taylor Watershed Community Observatory Sites directory, and ER-RBTn (upslope n=1) are sampling transects during the 2019 Rootball Campaign. The sample and location information can be found in metadata.csv. Sampling and Measurements Each sample falls into one of the three sampling methods – (1) intact cores, (2) repacked samples, or (3) soil sensors – and one of the two measurement methods – (a) laboratory or (b) in-situ. Both intact cores and repacked samples were measured using the laboratory methods, which include measurements of soil water potential (HYPROP & WP4C, METER), saturated (KSAT, METER) and unsaturated hydraulic conductivity (HYPROP). The in-situ method uses a pair of co-located soil sensors to measure volumetric water content (TEROS12, METER) and soil water potential (TEROS21, METER), and the hydraulic conductivity was not measured. In comparison, the laboratory methods progress from full saturation to dry conditions, and the in-situ method includes both dry-to-wet and wet-to-dry cycles. The sampling and measurement methods for each sample can be found in metadata.csv, and more information about the measurements is detailed in the Methods section below. Models Retention and hydraulic conductivity data were fitted with four van-Genuchten-type models (specified by “model_name” column in the files): (1) traditional constrained van Genuchten model (“vG_constrained”), (2) traditional unconstrained van Genuchten model (“vG_unconstrained”), (3) PDI-variant of the constrained van Genuchten model (“vG_constrained_PDI”), and (4) PDI-variant of the unconstrained van Genuchten model (“vG_unconstrained_PDI”). The difference between the constrained (1: n) and the unconstrained (2: n, m) van Genuchten models is the number of pore-size distribution parameters in the model equations, giving the unconstrained model more degrees of freedom when fitting the data. Between the traditional and the PDI-variant models, model fitting differs the most at the dry end of the measurements. The traditional models allow infinite suction at the residual water content (water content does not drop below residual water content), and the PDI-variant models enforce a soil water potential value of pF=6.8 (~ -630 MPa) at oven-dryness (water content reaches 0). The inclusion of the van-Genuchten-type models is due to their common application. If other retention models are required, users can access the data in data.csv for further data fitting. More information about the models can be found in the Methods section below. Fitting Tasks The model fitting can be categorized into three levels of tasks (specified by “fitting_task” column in the files). Level 1 (“fit_retention”) only includes retention data fitting (the only level available for the in-situ method). Level 2 (“fit_retention_conductivity”) includes both retention and hydraulic conductivity data fitting, and the saturated hydraulic conductivity (Ks, a parameter of the hydraulic conductivity functions) is fixed by the measurements from KSAT. Level 3 (“fit_retention_conductivity_Ks”) also includes both retention and hydraulic conductivity data fitting, but Ks is a fitted parameter without the constraints from KSAT measurements. Among the same retention models (e.g. vG_constrained models of the same sample), level 1 should produce the best retention data fitting. Level 2 should have the highest misfit of the retention and hydraulic conductivity data, because the retention and hydraulic conductivity functions share common model parameters, and the unsaturated hydraulic conductivity (HYPROP) data fitting is subject to Ks measured independently by KSAT. Level 3 should have mid-level misfits of the retention and hydraulic conductivity data. While level 3 fits the hydraulic conductivity data better than level 2, the fitted Ks value might be unreasonable due to the lack of constraints at the wet end of the measurements. General recommendation when using this data package: (1) Choice of sampling methods: Intact cores and in-situ soil sensors could be prioritized because these sampling methods are less destructive. While the repacked samples were packed to the target bulk density (estimated post-sampling, when sample volume was known), these samples had altered pore structures. Nevertheless, intact cores might suffer from sample gaps that would lead to overestimation of Ks (sample gaps can be inferred from the “soil_sample_volume” column in metadata.csv when the value is < 249). In-situ method also has higher uncertainty in characterizing the wet end of the SWRC because of sensor limitations and the difficulty in reaching full saturation under natural conditions. (2) Choice of fitting tasks: When only retention data is needed, level 1 (“fit_retention”) should be prioritized. When both retention and hydraulic conductivity data are needed, level 2 (“fit_retention_conductivity”) could be prioritized. (3) Choice of models: This could depend on what the downstream models call for. If no specific model is required, model misfit could be used as a ranking criterion. Model misfit values in terms of RMSE can be found in model_parameters.csv. The following files are included in this data package: (1) metadata.csv – This file includes the general information of each sample, including location (description, geocoordinates, elevation), sampling and measurements details (method, depth, time or period, volume, instruments), and soil physical properties (bulk density, saturated hydraulic conductivity, only applicable to physical soil samples). (2) data.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity data of each sample. Column “instrument” specifies the instrument (HYPROP, WP4C, or TEROS) used to perform the measurements. (3) model_fit.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity fitted from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the variable does not apply to that fitting task. (4) model_parameters.csv – This file includes the fitted model parameters, model misfits, and conventional water content thresholds (field capacity and wilting point) from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the parameter does not apply to that model and/or that fitting task. (5) data_Ks.csv – This file includes the saturated hydraulic conductivity measurements from KSAT. (6) /figure/*.png – This folder includes three quick visualizations of the data, retention model fitting results and misfits, and hydraulic conductivity model fitting results, misfits, and parameters. The model fitting results are separated by samples and fitting tasks and colored by models. Zoom-in required. (7) /hyprop/*.bdhx – This folder includes proprietary hyprop files that require the free Labros SoilView-Analysis (METER) to open. Users can explore data fitting using other retention models (i.e. Brooks-Corey, Fredlund-Xing, Kosugi, bimodal models). Be aware that Ks value is pre-entered under “Fitting tab, Conductivity functions parameters” for level 2 fitting. If the value is lost, please refer to metadata.csv under “Ks” column. (8) Six file-level metadata that summarize file, header, column, and variable information of all files. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

EARTH SCIENCE > LAND SURFACE > SOILS↗

Soil Water Retention and Hydraulic Conductivity Data and Model at Snodgrass Mountain in East River Watershed, Colorado 2020-2025

This data package includes soil water retention and hydraulic conductivity data and model fitting results from measurements of ex-situ soil samples and in-situ soil sensors at Snodgrass Mountain. Soil water retention curves (SWRC) characterize soil water content as a function of soil water potential. SWRC depends on soil texture and pore structure and can be used to describe the constraints on biogeochemical processes in terms of soil water availability. In this data package, the sample identification follows the format SG-X-Y, where SG refers to Snodgrass Mountain, X is the location identifier, and Y is the depth identifier at the same X (shallow Y=1). Specifically, SG-EHS is associated with ecohydrology sites under the East-Taylor Watershed Community Observatory Sites directory, and SG-ERTn (upslope n=1) are points along the Snodgrass electrical resistivity tomography transect not associated with the existing site names in the directory. The sample and location information can be found in metadata.csv. Sampling and Measurements Each sample falls into one of the three sampling methods – (1) intact cores, (2) repacked samples, or (3) soil sensors – and one of the two measurement methods – (a) laboratory or (b) in-situ. Both intact cores and repacked samples were measured using the laboratory methods, which include measurements of soil water potential (HYPROP & WP4C, METER), saturated (KSAT, METER) and unsaturated hydraulic conductivity (HYPROP). The in-situ method uses a pair of co-located soil sensors to measure volumetric water content (TEROS12, METER) and soil water potential (TEROS21, METER), and the hydraulic conductivity was not measured. In comparison, the laboratory methods progress from full saturation to dry conditions, and the in-situ method includes both dry-to-wet and wet-to-dry cycles. The sampling and measurement methods for each sample can be found in metadata.csv, and more information about the measurements is detailed in the Methods section below. Models Retention and hydraulic conductivity data were fitted with four van-Genuchten-type models (specified by “model_name” column in the files): (1) traditional constrained van Genuchten model (“vG_constrained”), (2) traditional unconstrained van Genuchten model (“vG_unconstrained”), (3) PDI-variant of the constrained van Genuchten model (“vG_constrained_PDI”), and (4) PDI-variant of the unconstrained van Genuchten model (“vG_unconstrained_PDI”). The difference between the constrained (1: n) and the unconstrained (2: n, m) van Genuchten models is the number of pore-size distribution parameters in the model equations, giving the unconstrained model more degrees of freedom when fitting the data. Between the traditional and the PDI-variant models, model fitting differs the most at the dry end of the measurements. The traditional models allow infinite suction at the residual water content (water content does not drop below residual water content), and the PDI-variant models enforce a soil water potential value of pF=6.8 (~ -630 MPa) at oven-dryness (water content reaches 0). The inclusion of the van-Genuchten-type models is due to their common application. If other retention models are required, users can access the data in data.csv for further data fitting. More information about the models can be found in the Methods section below. Fitting Tasks The model fitting can be categorized into three levels of tasks (specified by “fitting_task” column in the files). Level 1 (“fit_retention”) only includes retention data fitting (the only level available for the in-situ method). Level 2 (“fit_retention_conductivity”) includes both retention and hydraulic conductivity data fitting, and the saturated hydraulic conductivity (Ks, a parameter of the hydraulic conductivity functions) is fixed by the measurements from KSAT. Level 3 (“fit_retention_conductivity_Ks”) also includes both retention and hydraulic conductivity data fitting, but Ks is a fitted parameter without the constraints from KSAT measurements. Among the same retention models (e.g. vG_constrained models of the same sample), level 1 should produce the best retention data fitting. Level 2 should have the highest misfit of the retention and hydraulic conductivity data, because the retention and hydraulic conductivity functions share common model parameters, and the unsaturated hydraulic conductivity (HYPROP) data fitting is subject to Ks measured independently by KSAT. Level 3 should have mid-level misfits of the retention and hydraulic conductivity data. While level 3 fits the hydraulic conductivity data better than level 2, the fitted Ks value might be unreasonable due to the lack of constraints at the wet end of the measurements. General recommendation when using this data package: (1) Choice of sampling methods: Intact cores and in-situ soil sensors could be prioritized because these sampling methods are less destructive. While the repacked samples were packed to the target bulk density (estimated post-sampling, when sample volume was known), these samples had altered pore structures. Nevertheless, intact cores might suffer from sample gaps that would lead to overestimation of Ks (sample gaps can be inferred from the “soil_sample_volume” column in metadata.csv when the value is < 249). In-situ method also has higher uncertainty in characterizing the wet end of the SWRC because of sensor limitations and the difficulty in reaching full saturation under natural conditions. (2) Choice of fitting tasks: When only retention data is needed, level 1 (“fit_retention”) should be prioritized. When both retention and hydraulic conductivity data are needed, level 2 (“fit_retention_conductivity”) could be prioritized. (3) Choice of models: This could depend on what the downstream models call for. If no specific model is required, model misfit could be used as a ranking criterion. Model misfit values in terms of RMSE can be found in model_parameters.csv. The following files are included in this data package: (1) metadata.csv – This file includes the general information of each sample, including location (description, geocoordinates, elevation), sampling and measurements details (method, depth, time or period, volume, instruments), and soil physical properties (bulk density, saturated hydraulic conductivity, only applicable to physical soil samples). (2) data.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity data of each sample. Column “instrument” specifies the instrument (HYPROP, WP4C, or TEROS) used to perform the measurements. (3) model_fit.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity fitted from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the variable does not apply to that fitting task. (4) model_parameters.csv – This file includes the fitted model parameters, model misfits, and conventional water content thresholds (field capacity and wilting point) from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the parameter does not apply to that model and/or that fitting task. (5) data_Ks.csv – This file includes the saturated hydraulic conductivity measurements from KSAT. (6) /figure/*.png – This folder includes three quick visualizations of the data, retention model fitting results and misfits, and hydraulic conductivity model fitting results, misfits, and parameters. The model fitting results are separated by samples and fitting tasks and colored by models. Zoom-in required. (7) /hyprop/*.bdhx – This folder includes proprietary hyprop files that require the free Labros SoilView-Analysis (METER) to open. Users can explore data fitting using other retention models (i.e. Brooks-Corey, Fredlund-Xing, Kosugi, bimodal models). Be aware that Ks value is pre-entered under “Fitting tab, Conductivity functions parameters” for level 2 fitting. If the value is lost, please refer to metadata.csv under “Ks” column. (8) Six file-level metadata that summarize file, header, column, and variable information of all files. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

EARTH SCIENCE > LAND SURFACE > SOILS↗

Post-Test SEM Examination of Brady Core, Desert Peak Core, and Stripa Granite Samples

As part of the shear-induced permeability test of Brady well BCH-03, Desert Peak well DP 35-13, and Stripa granite samples, the three post-test (reacted) rock samples were examined using a Scanning Electron Microscope (SEM). The SEM images of the core and elemental analysis are included in this submission for each sample.

15 GEOTHERMAL ENERGY↗

Artifact-Free Coring Procedures for Removing Samples from Photovoltaic Modules for Microscopic Analysis

An important step in producing more reliable and efficient photovoltaic modules is to establish a relationship between the microscopic properties of modules deployed in the field for many years and efficiency-related parameters. The first step in accomplishing this task is to be able to identify and remove small areas from these modules without causing any damage to these samples. In this work, we will describe two different procedures to core small areas of deployed and stressed solar panels produced with different materials (Si, CIGS, and CdTe), and we will prove that these processes did not damage the cored material. We will also show that the coring procedure changes for different types of photovoltaic modules.

14 SOLAR ENERGY↗