Search NASA⌕ Search

SEARCH · Search NASA

Results for “cost data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

NREL and Clemson University Drivetrain Test Facility Collaboration: Cooperative Research and Development Final Report, CRADA Number CRD-13-509

The National Renewable Energy Laboratory (NREL) and Clemson University have a mutual interest in collaborating in the development of wind turbine drivetrain testing facilities and grid simulators. NREL and Clemson University will work together to share resources and experiences in the development of future wind energy test facilities and capabilities. The CRADA includes sharing of facility topologies and capabilities, modeling efforts, commissioning plans, test protocols, infrastructure cost data, test plans, pro forma contracting instruments, and safe operating strategies. Further, NREL and Clemson University will exchange staff for training and development purposes, including collaborative participation in commissioning and customer testing. DOE has provided NREL with over 10 years of support in developing custom facilities and capabilities to enable testing of full-scale integrated wind turbine drivetrain systems in accordance with the needs of the US wind industry. NREL currently operates a 2.5MW dynamometer and is in the processes of building a 5MW dynamometer and a grid simulator (referred to as a 'Controllable Grid Interface' or CGI). Clemson University is currently building a drivetrain testing facility with two dynamometers, 7.5 MW and 15 MW, and 15 MW Hardware in the loop grid simulator.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cost and Performance Baseline for Fossil Energy Plants - Volume 3: Low Rank Coal and Natural Gas to Electricity

The Cost and Performance Baseline for Fossil Energy Plants - Volume 3: Low Rank Coal and Natural Gas to Electricity contains three separate reports including 28 cases: integrated gasification combined cycle plants (Volume 3a), combustion plants (Volume 3b), and natural gas combined cycle plants (Volume 3c). This study establishes performance and cost data for fossil energy power systems, specifically integrated gasification combined cycle (IGCC), combustion, and natural gas combined cycle (NGCC) plants all with and without carbon capture and sequestration. Most of the coal fired plants are studied using both Rosebud Montana Powder River Basin Coal (PRB) at a Montana site at an elevation of 3,400 feet and North Dakota Lignite (NDL) at a mine-mouth North Dakota site at an elevation of 1,900 feet. NGCC plants are also studied at both locations. The analyses were performed on a consistent technical and economic basis that accurately reflects current market conditions for coal-fueled plants

01 COAL, LIGNITE, AND PEAT↗

Cost and Performance Baseline for Fossil Energy Plants - Volume 3b: Low Rank Coal to Electricity: Combustion Cases

The Cost and Performance Baseline for Fossil Energy Power Plants Study, Volume 3b: Low Rank Coal to Electricity establishes performance and cost data for fossil energy power systems, specifically pulverized coal (PC) and circulating fluidized bed combustor (CFBC) plants all with and without carbon capture and sequestration. The analyses were performed on a consistent technical and economic basis that accurately reflects current market conditions. The study serves as a benchmark to track the progress of DOE Advanced Power Systems R&D and as a baseline for analyzing fossil energy plant options.

01 COAL, LIGNITE, AND PEAT↗

Cost and Performance Baseline for Fossil Energy Plants - Volume 3c: Natural Gas Combined Cycle at Elevation

The Cost and Performance Baseline for Fossil Energy Power Plants Study, Volume 3b: Low Rank Coal to Electricity establishes performance and cost data for fossil energy power systems, specifically pulverized coal (PC) and circulating fluidized bed combustor (CFBC) plants all with and without carbon capture and sequestration. The analyses were performed on a consistent technical and economic basis that accurately reflects current market conditions. The study serves as a benchmark to track the progress of DOE Advanced Power Systems R&D and as a baseline for analyzing fossil energy plant options.

03 NATURAL GAS↗

Brief Update on Advancements by Commercial Vendors/Options for Feeding and Pumping Biomass Slurries for Hydrothermal Liquefaction

In 2011, Pacific Northwest National Laboratory (PNNL), working as a partner in the National Advanced Biofuels Consortium, issued a report assessing the viable industrial feed system and pump options for a 2000 dry metric tons per day production-scale hydrothermal liquefaction (HTL) plant (Berglin et al. 2012). This report was issued as PNNL-21981, Review and Assessment of Commercial Vendors/Options for Feeding and Pumping Biomass Slurries for Hydrothermal Liquefaction, and will be referred to as “Pump Survey” for reference. It had the following scope: • Identify relevant applications and industries operating at comparable scales • Interact with commercial vendors and pursue integration between vendors • Take advantage of commercial off-the-shelf (COTS) technology • Supply and support vendor needs for biomass feedstock rheology characterization • Provide vendors with process requirements to support selection of conceptual design for feedstock handing and pump system • Obtain cost data to the extent possible from equipment vendors to support the technical economic analysis (TEA) • Identify issues associated scale-up. The current document represents an update to the prior report in order to: 1. Identify advancements in vendor-reported technologies 2. List reports of new experience or trials with biomass pumping applications 3. Determine if technology/application gaps identified in the prior report have been filled 4. Capture ideas on future research.

09 BIOMASS FUELS↗

DSO+T: Valuation Methodology and Economic Metrics (DSO+T Study: Volume 4)

This report summarizes a rigorous valuation analysis methodology used by the Distribution System Operator with Transactive (DSO+T) study to estimate the financial benefits and costs of adopting Transactive Energy coordination of distributed energy resources for key stakeholders (for example distribution system operators and customers). This was achieved by modeling the value exchanges between stakeholders and determining the annualized costs and revenues experienced by stakeholders, enabling the evaluation of overall impact on stakeholder’s annualized cash flow. Extensive work was conducted developing methods to estimate the operating costs of distribution system operators at a level of granularity that would allow the financial impact of implementing a transactive energy approach to be estimated. This work included developing parametric models for labor and software costs, distribution system capital and maintenance costs, growth rates, and factors to determine annualized costs of capital investments. Simulation results were used to calculate wholesale energy costs and revenues from retail sales. Valuation analysis methods were also developed for other stakeholders including customers, the transmission system operator, independent system operator, and generators. The resulting capability allows a complete mapping of the flow of financial value between stakeholders that can be directly integrated with the results of demand flexibility simulations. Example results are provided for a business-as-usual case and compared to a transactive energy case as well as to actual cost data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Economic Impact of Permitting Timelines on Geothermal Power in California, Nevada, and Utah

The United States has great geothermal power potential; however, only a small fraction of this resource has been utilized for power generation. Various barriers, including technical, financial, and regulatory permit delays, are attributed to the lower penetration of geothermal energy into the national grid. Unpredictable environmental reviews and permitting timelines are some of the non-technical barriers that can cause delays in geothermal exploration and utilization plans. This document provides an assessment of the potential economic impact of permitting costs and timelines on geothermal power in California, Nevada, and Utah. Development of geothermal resources requires multi-layered regulatory permitting by local, state, and federal agencies. In this study, we collected and reviewed permit timelines and associated cost data for several existing geothermal power plants as well as for geothermal projects currently undergoing permitting processes for exploration and development activities in California, Nevada, and Utah. We interviewed several geothermal developers and staff from multiple permitting agencies to obtain insight from both sides (i.e., people applying for permits and people processing those applications for California Environmental Quality Act [CEQA] and National Environmental Policy Act [NEPA] reviews and other regulatory compliance). The intent of this project was also to identify informative pathways for the geothermal stakeholder community by which the permitting process could be streamlined.

15 GEOTHERMAL ENERGY↗

Summary Report of HERO WEC Test Article for Waves to Water: Electrical Power Take-Off

The National Renewable Energy Laboratory (NREL) designed and fabricated the hydraulic and electric reverse osmosis (HERO) wave energy converter (WEC), which is a modular system that can utilize either an electrical or hydraulic power take-off (PTO) system to power a desalination device. The method by which this device can convert mechanical work to either hydraulic or electrical energy is by harnessing the energy from waves via a rotary output shaft. This report describes the electrical configuration, where a rotary generator replaces the pump in the hydraulic configuration to power a submersible pump and reverse osmosis unit via an electrical cable, rather than a hydraulic line/hose. This device is of a non-proprietary design where every aspect of the design is made public, including the physical designs, non-proprietary cost data, and electrical drawings developed for the build of this device.

16 TIDAL AND WAVE POWER↗

Renewable Thermal Energy Systems: Characterization of the Most Important Thermal Energy Applications in Buildings and Industry (Report 1)

This report is the first in a three-report series that evaluates the provision of renewable heat for industry and buildings via current and prospective renewable thermal energy system (RTES) technologies. The RTES project has undertaken initial research focused on technologies that could be suited for industrial process heat applications at different temperature levels, and, where possible, gathered performance and cost data for these technologies. This project does not directly evaluate RTES for distributed residential or commercial applications, nor does it yet include documented cases or modeling of RTES using geothermal, biomass, waste heat, renewable fuels like renewable natural gas, or hydrogen production. The three technical reports are summarized as follows: Renewable Thermal Energy Systems: Characterization of the Most Important Thermal Energy Applications in Buildings and Industry (Report 1), this report: summary of thermal demands of U.S. industry and buildings, and relevant hybrid RTES configurations; Renewable Thermal Energy Systems: Systemic Challenges and Transformational Policies (Report 2): discussion of socio-technical characteristics of RTES, innovation challenges, and supporting policies. Available at: https://www.nrel.gov/docs/fy23osti/83020.pdf; Renewable Thermal Energy Systems: Modeling Developments and Future Directions (Report 3): Energy yield and performance modeling of RTES, techno-economic analysis via case studies, and proposed development of a user decision support tool. Available at: https://www.nrel.gov/docs/fy23osti/83021.pdf.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Representation of Fossil Power Generation Technologies in NREL’s Annual Technology Baseline

This presentation was delivered at the Energy Economics USAEE/IAEE North American Conference on November 7, 2023. The presentation highlights support provided by the National Energy Technology Laboratory (NETL) on the development of National Renewable Energy Laboratory's (NREL) Annual Technology Baseline (ATB). The ATB documents transparent, normalized technology cost and performance assumptions using public sources. NETL's role in the development was to provide NREL with performance and cost data for select fossil-based technology classes. The ATB was released in June 2023.

Hackett, Gregory↗

Design and Optimization of Processes for Recovering Rare Earth Elements from End-of-Life Hard Disk Drives

In this poster, we first provide motivation for why rare earth elements as rare earth permanent magnets (REPM) are increasing in demand. We then highlight some of the recent work that has been done by several national labs (National Renewable Energy Laboratory (NREL), Environmental Protection Agency (EPA), Critical Minerals Institute (CMI)) on recycling rare earth elements from end-of-life hard disk drives (EOL). Then, we mention our long-term plan to design a feedstock agnostic process to recover rare earth elements as rare earth oxides from many different EOL products at once. Next, we discuss how we quantified the rare earth elements available for recycling from EOL hard disk drives from consumer desktops and laptops. We then discuss how we used superstructure optimization to design the optimal pathway. The proposed superstructure was modeled as a MILP optimization problem, selecting the net present value as the objective function. Costing data from the literature was used to inform this model whenever possible. However, due to the novelty of this research area, data were often unavailable, thus requiring the generation of flowsheets implemented in Aspen Plus.

Laliwala, Chris↗

Progressing Analysis of Variable Electric Rates (PAVER) Study

The Progressing Analysis of Variable Electric Rates (PAVER) study analyzed the impact of a range of time-varying electric rates on the performance of a regional electric grid and the resulting costs for participating and non-participating customers. This analysis leveraged and extended the work of PNNL’s Distribution System Operator with Transactive (DSO+T) study. Five different rate designs were included: a flat volumetric energy charge, a typical Time of Use (TOU) rate, a dynamic energy (DE) rate (based on wholesale locational marginal prices), a dynamic energy and capacity (DE+C) rate, and, finally, a Block and Swing (B&S) rate that billed customers based on their average load profile at constant pricing, but used the DE+C dynamic price for load deviations from their average profile. These rates were analyzed in a large-scale co-simulation of an entire regional grid with a customer population representative of the current state. A large fraction (80%) of residential and commercial customers were assumed to participate in these time-varying rates with automatically controlled HVAC, water heaters, electric vehicles, and batteries. This study assumed no industrial sector participation. The DE and DE+C rates saw system peak loads reduced by 6-7%, while the large participation in the TOU rate case saw a significant rebound effect and a resulting peak load increase of >5%. The impacts to the annual and peak system demand impacted system wholesale prices and the overall grid operating costs. This cost structure determined the revenue needed to be collected from customers by each rate design. Participating customers on the DE and DE+C rates (located in one of the modeled DSOs) saw reductions in average annual electricity bills of 11-17% with average increases in monthly bill variation of no more than 13%. At such high participation levels, TOU customers saw 10% higher average annual bills (due to system-wide rebound effects) and average increased monthly bill variation of 16%. Residential owners of large flexible loads (such as electric vehicles) saw larger bill savings (17-20%) when on a fully dynamic rate. The presence of on-site generation (such as rooftop solar) did not appear to appreciably change customer outcomes. Customers on the Block and Swing rate did see 6% lower monthly bill variation (as intended) than the flat rate case, but at the expense of appreciable bill savings, which were only 3%, comparable to the savings seen by non-participants. Given this finding we recommend that additional research be conducted into how best various bill protection mechanisms can balance minimizing customer bill variation with providing financial incentives commensurate with the flexibility customers provide. We also recommend that customer outcomes be explored across a range of regions using current actual customer and system cost data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Barrier Immune Radio Communications for Demand Response

Various wireless technologies were field-tested in a six-story laboratory building to identify wireless technologies that can scale for future DR applications through very low node density power consumption, and unit cost. Data analysis included analysis of the signal-to-noise ratio (SNR), packet loss, and link quality at varying power levels and node densities. The narrowband technologies performed well, penetrating the floors of the building with little loss and exhibiting better range than the wideband technology. 900 MHz provided full coverage at 1 watt and substantially complete coverage at 500 mW at the test site. 900 MHz was able to provide full coverage at 100 mW with only one additional relay transmitter, and was the highest-performing technology in the study. 2.4 GHz could not provide full coverage with only a single transmitter at the highest power level tested (63 mW). However, substantially complete coverage was provided at 2.4 GHz at 63 mW with the addition of one repeater node.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comfort in High-Performance Homes in a Hot-Humid Climate

TO5 2.3.2: Large-Scale Temperature Study Although space-conditioning systems are required to meet standards such as those in the Air Conditioning Contractors of America (ACCA) Manual RS (Rutkowski 1997) and the ASHRAE Standard 55 (ASHRAE 2013) comfort criteria, little is known about how space-conditioning systems are actually operating in the field and if these systems are meeting those standards. Unconventional space-conditioning systems may be necessary for low-load homes in the future. It is important to know how current systems are functioning in existing homes and to what temperatures occupants typically set the thermostats in their homes. The U.S. Department of Energy's Building America research team IBACOS set out to find some answers. By using low-cost data loggers and occupant surveys to monitor 37 single-family homes that have standard heating, ventilating, and air-conditioning (HVAC) equipment, the team gained insight into how sensitive occupants are to comfort in their homes relative to the ACCA and ASHRAE standards. This study focused on one climate zone (hot-humid); however, future studies may find differences among occupants- ideas of thermal comfort in other climate zones. Data were collected from installed sensors during a 2-month period from late August 2014 through late October 2014. The final aspect of this project was to review the business metrics associated with builders involved in a comfort and performance guarantee program. The results of this study-taken as an aggregate-show that the homes provided room-to-room temperature differences less than 6 degrees F 95% of the time. Temperature differences were less than 4 degrees F 80% of the time. Some homes showed better or worse performance. On average, two-story homes had a 3.3 degrees F temperature difference between rooms; single-story homes had an average of a 2.2 degrees F temperature difference between rooms. Occupants who did not use programmable thermostats had an average set point of 75 degrees F. Homes in which the thermostats were programmed with a setback schedule showed a median baseline temperature value of 74 degrees F and had a median afternoon setback of 75 degrees F. System runtime was analyzed and showed that the room-to-room temperature uniformity in some homes worsened during an on cycle, whereas the uniformity improved in other homes. That is, when the system was running, some rooms were receiving too much or too little air relative to the rest of the house, and the temperatures in those rooms were moving away from the temperatures of the other rooms in the house. Finally, analysis of the thermostat data shows a wide degree of variability among homes in the study. Interpretation of the measured data suggests that 21 occupants made no regular adjustments to the thermostats in their homes, seven had regular setbacks, seven showed varying setbacks, and 10 appeared to follow no pattern (with random adjustments). Ultimately, the data show that current systems are maintaining expected levels of comfort. As expected, it is more challenging to maintain a uniform temperature in all rooms of two-story homes, and future systems should address this issue. Furthermore, the data show that the majority of homes maintained relative humidity levels below 60% without any supplemental dehumidification

ACCA Manual RS↗

Tandem Photovoltaics Core Program Final Technical Report

The Tandem Photovoltaics Core Program was a multi-year initiative aimed at advancing hybrid tandem solar cell technologies to enhance solar module efficiency beyond the limits of single junction devices. This project focused on the development, testing, and scaling of prototype photovoltaic devices, with the goal of achieving commercial relevance and driving industry adoption. The work was divided into three tasks: 1) Comparative Analysis of Tandem Technologies: This task focused on quantifying energy yield under real-world conditions and assessing economic viability of tandems relative to silicon-based modules. The project's modeling framework incorporated performance data, cost of materials, and manufacturing process impacts to optimize tandem designs 2) Tandem Integration and Prototyping: In this task, we developed innovative tandem designs by combining metal halide perovskite (MHP) top cells and silicon (Si) bottom cells. The project focuses on both mechanical integration and direct deposition techniques to enable compatibility with commercially relevant Si technologies, such as passivated contact or PERC cells. 3) Scale-up and Reliability: This task addressed the challenges of large-area fabrication by developing scalable deposition methods and robust interconnection schemes for tandems. The project looked at different accelerated testing such as thermal cycling, damp heat exposure, and potential induced degradation, to ensure long-term stability of devices in field conditions. Tandem solar cells can greatly increase module efficiency beyond conventional single junction (SJ) devices, which are approaching their theoretical limit. There are many ways to fabricate a tandem cell or module in terms of materials used, configuration, and terminal connection. This SETO core project focused critical factors in enabling tandems to enter the market, including hardware integration, technoeconomic analysis (TEA), and energy yield analysis. We focused on MHP/Si hybrid tandem solar cells and modules as a model system for their versatility in module design comparisons, providing valuable insights for other tandem options. While champion cells with areas <1cm2 are regularly demonstrated by groups around the world, it is significantly more challenging to translate these advances into modules, and fewer institutions and companies are working at the module level. This project addressed questions about module fabrication, testing, and reliability that are hard to answer without actually fabricating prototypes. We also performed analysis and road-mapping activities to understand the potential for a wider variety of tandems, including all-perovskite tandems fabricated in collaboration with the Perovskite PV core program. Detailed technical results from this project are described for each task in Section 7.

14 SOLAR ENERGY↗

Design and Optimization of Processes for Recovering Rare Earth Elements from End-of-Life Hard Disk Drives

In this conference paper, we propose a superstructure-based approach to finding the optimal pathways for recovering rare earth elements in their commercialized rare earth oxide form from end-of-life HDDs. The proposed superstructure was modeled as a MILP optimization problem, selecting the net present value as the objective function. Whenever possible, costing data taken from the literature was used to inform this mode. However, due to the novelty of this research area data were often not available thus requiring the generation of flowsheets that were implemented in Aspen Plus. To establish the base case optimal result, projections for the number of EOL HDDs in the U.S. available for recycling and estimates of the projected rare earth oxide prices over the lifetime of the plant were used to inform the model. The model was then expanded to include the recycling of EOL HDDs generated prior to the beginning of plant production (period ranging from 2006 through 2024).

Laliwala, Chris↗

Computational techniques for design optimization of thermal protection systems for the space shuttle vehicle. Volume 1: Final report

Computational techniques were developed and assimilated for the design optimization. The resulting computer program was then used to perform initial optimization and sensitivity studies on a typical thermal protection system (TPS) to demonstrate its application to the space shuttle TPS design. The program was developed in Fortran IV for the CDC 6400 but was subsequently converted to the Fortran V language to be used on the Univac 1108. The program allows for improvement and update of the performance prediction techniques. The program logic involves subroutines which handle the following basic functions: (1) a driver which calls for input, output, and communication between program and user and between the subroutines themselves; (2) thermodynamic analysis; (3) thermal stress analysis; (4) acoustic fatigue analysis; and (5) weights/cost analysis. In addition, a system total cost is predicted based on system weight and historical cost data of similar systems. Two basic types of input are provided, both of which are based on trajectory data. These are vehicle attitude (altitude, velocity, and angles of attack and sideslip), for external heat and pressure loads calculation, and heating rates and pressure loads as a function of time.

Source record↗