Search NASA⌕ Search

SEARCH · Search NASA

Results for “crossover”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Daily Supine LBNP Treadmill Exercise Maintains Upright Exercise Capacity During 14 Days of Bed Rest

Exposure to microgravity or bed rest reduces upright exercise capacity. Exercise modes, durations, and intensities which will effectively and efficiently counteract such deconditioning are presently unresolved. We that daily supine treadmill interval training with lower body negative pressure (LBNP) would prevent reduction in upright exercise capacity during 14 days of 6 deg. head-down bed rest (BR). Eight healthy male subjects underwent two 14 day BR protocols separated by 3 months. In a crossover design, subjects either remained at strict BR or performed 40 min of daily exercise consisting of supine walking and running at intensities varying from 40-80% of pre-BR upright peak oxygen uptake (VO2). LBNP during supine exercise was used to provide 1.0 to 1.2 times body weight of footward force. An incremental upright treadmill test to measure submaximal and peak exercise responses was given pre- and post-BR. In the non-exercise condition, peak VO2 and time to exhaustion were reduced 16 +/- 4% and 10 +/- 1% (p less than 0.05), respectively, from pre-BR. With LBNP exercise these variables were not significantly different (NS) from pre-BR. During submaximal treadmill speeds after BR, heart rate was higher (11 +/- 11 bpm, p less than 0.05) and respiratory exchange ratio was elevated (p less than 0.05) in the no exercise condition. Both were maintained at pre-BR levels in the LBNP exercise condition (NS from pre-BR). Since this supine treadmill interval training with addition of LBNP maintained upright exercise responses and capacity during BR, this countermeasure may also be effective during space flight.

Ertl, Andy C.↗

Genetic Evolution of Shape-Altering Programs for Supersonic Aerodynamics

Two constrained shape optimization problems relevant to aerodynamics are solved by genetic programming, in which a population of computer programs evolves automatically under pressure of fitness-driven reproduction and genetic crossover. Known optimal solutions are recovered using a small, naive set of elementary operations. Effectiveness is improved through use of automatically defined functions, especially when one of them is capable of a variable number of iterations, even though the test problems lack obvious exploitable regularities. An attempt at evolving new elementary operations was only partially successful.

Kennelly, Robert A., Jr.↗

UAH Analysis of TIDE/PSI Data for ISTP Solar Maximum Extended Mission

During the course of this research, several investigations have been carried out at both high and low altitudes. The low altitude studies are those associated with perigee observations of ion field-aligned flows measured by POLAR/TIDE near 5000 km altitude. High altitude studies employed ion observations near apogee (above 6 R(sub E) geocentric). In both cases the observations occur at high latitudes, in or near the polar regions: the southern polar region for the low altitude studies and the northern polar region for the high altitude studies. A study of the relationship between field-aligned flow velocities, fluxes, and densities to convection speeds was published in the Journal of Atmospheric and Terrestrial Physics . Here we have demonstrated an anti-correlation between the 0+ densities and the convection speeds, and a correlation between the parallel upward velocities and the convection speeds, and have discussed these results as being compatible with the Cleft Ion Fountain concept for supplying O(sup +) ions to the polar cap magnetosphere. Another topic investigated was the relationship between TIDE-observed upward and downward parallel O(sup +) bulk velocities near 5000 km altitude over the southern polar regions, and near-simultaneous auroral observations by the Ultra-Violet Imager. We have prepared several overlaid plots of such auroral images across an MLT-ILAT dial plot of the polar regions with upward and downward velocities, as well as other parameters such as ion densities and fluxes. The overlaid plots show quite nicely how upward velocities and crossovers between upward and downward velocities occur in association with auroral forms, while downward flows are associated with dark regions of the polar cap.

Comfort, Richard H.↗

JASON-1 Precise Orbit Determination (POD)with SLR and DORIS Tracking

Jason-1, the TOPEX/POSEIDON (T/P) radar altimeter follow-on, is intended to continue measurement of the ocean surface with the same, if not better accuracy. T/P has demonstrated that, the time variation of ocean topography can be determined with an accuracy of a few centimeters, thanks to the availability of highly accurate orbits based on SLR and DORIS tracking. For verification and cross-calibration, Jason-1, was initially injected into the T/P orbit, flying just 72 seconds ahead of T/P. This configuration lasted over 21 Jason cycles. In mid-August T/P was maneuvered into its final tandem configuration, a parallel groundtrack, in order to improve the combined coverage. Preliminary investigations using cycles 1-9, shown at the June 2002 SWT, indicated that nominal Jason orbits can achieve the 2-3 cm accuracy objective, however several puzzling aspects of SLR and DORIS measurement modeling were also observed. This paper presents recent analysis of Jason SLR+DORIS POD spanning more than 20 cycles, and revisits several of the more puzzling issues, including estimation of the Laser Retroreflector Array (LRA) offset. The accuracy of the orbits and of the measurement modeling are evaluated using several tests, including SLR, DORIS, and altimeter crossover residual analysis, altimeter collinear analysis, and direct comparison with GPS and other orbits. T/P POD results over the same period are used as a reference.

Zelensky, N. P.↗

Modeling Tetragonal Lysozyme Crystal Growth Rates

Tetragonal lysozyme 110 face crystal growth rates, measured over 5 orders of magnitude in range, can be described using a model where growth occurs by 2D nucleation on the crystal surface for solution supersaturations of c/c(sub eq) less than or equal to 7 +/- 2. Based upon the model, the step energy per unit length, beta was estimated to be approx. 5.3 +/- 0.4 x 10(exp -7) erg/mol-cm, which for a step height of 56 A corresponds to barrier of approx. 7 +/- 1 k(sub B)T at 300 K. For supersaturations of c/c(sub eq) > 8, the model emphasizing crystal growth by 2D nucleation not only could not predict, but also consistently overestimated, the highest observable crystal growth rates. Kinetic roughening is hypothesized to occur at a cross-over supersaturation of c/c(sub eq) > 8, where crystal growth is postulated to occur by a different process such as adsorption. Under this assumption, all growth rate data indicated that a kinetic roughening transition and subsequent crystal growth by adsorption for all solution conditions, varying in buffer pH, temperature and precipitant concentration, occurs for c/c(sub eq)(T, pH, NaCl) in the range between 5 and 10, with an energy barrier for adsorption estimated to be approx. 20 k(sub B)T at 300 K. Based upon these and other estimates, we determined the size of the critical surface nucleate, at the crossover supersaturation and higher concentrations, to range from 4 to 10 molecules.

Gorti, Sridhar↗

Polar Dunes Resolved by the Mars Orbiter Laser Altimeter Gridded Topography and Pulse Widths

The Mars Orbiter Laser Altimeter (MOLA) polar data have been refined to the extent that many features poorly imaged by Viking Orbiters are now resolved in densely gridded altimetry. Individual linear polar dunes with spacings of 0.5 km or more can be seen as well as sparsely distributed and partially mantled dunes. The refined altimetry will enable measurements of the extent and possibly volume of the north polar ergs. MOLA pulse widths have been recalibrated using inflight data, and a robust algorithm applied to solve for the surface optical impulse response. It shows the surface root-mean-square (RMS) roughness at the 75-m-diameter MOLA footprint scale, together with a geological map. While the roughness is of vital interest for landing site safety studies, a variety of geomorphological studies may also be performed. Pulse widths corrected for regional slope clearly delineate the extent of the polar dunes. The MOLA PEDR profile data have now been re-released in their entirety (Version L). The final Mission Experiment Gridded Data Records (MEGDR's) are now provided at up to 128 pixels per degree globally. Densities as high as 512 pixels per degree are available in a polar stereographic projection. A large computational effort has been expended in improving the accuracy of the MOLA altimetry themselves, both in improved orbital modeling and in after-the-fact adjustment of tracks to improve their registration at crossovers. The current release adopts the IAU2000 rotation model and cartographic frame recommended by the Mars Cartography Working Group. Adoption of the current standard will allow registration of images and profiles globally with an uncertainty of less than 100 m. The MOLA detector is still operational and is currently collecting radiometric data at 1064 nm. Seasonal images of the reflectivity of the polar caps can be generated with a resolution of about 300 m per pixel.

Gregory A Neumann↗

A High-Order, Time Invariant, Linearized Model for Application to HHCIAFCS Interaction Studies

This paper describes a methodology for the extraction of a linear time invariant model from a nonlinear helicopter model, and followed by an examination of the interactions of the Higher Harmonic Control (HHC) and the Automatic Flight Control System (AFCS). This new method includes an embedded harmonic analyzer inside a linear time invariant model, which allows the periodicity of the helicopter response to be captured. The: coupled high-order model provides the needed level of dynamic fidelity to permit an analysis and optimization of the AFCS and HHC loops. Results of this study indicate that the closed-loop HHC system has little influence on the AFCS or on the vehicle handling qualities, which indicates that the AFCS does not need modification to work with the HHC system. The results also show that the vibration response to maneuvers must be considered during the HHC design process, which leads to much higher required HHC loop crossover frequencies. This research also demonstrates that the transient vibration response during maneuvers can be reduced by optimizing the closed-loop higher harmonic control laws using conventional control system analyses.

Cheng, Rendy P.↗

Antarctic Ice-Sheet Mass Balance from Satellite Altimetry 1992 to 2001

A major uncertainty in understanding the causes of the current rate of sea level rise is the potential contributions from mass imbalances of the Greenland and Antarctic ice sheets. Estimates of the current mass balance of the Antarctic ice sheet are derived from surface- elevation changes obtained from 9 years of ERS - 1 & 2 radar altimeter data. Elevation time-series are created from altimeter crossovers among 90-day data periods on a 50 km grid to 81.5 S. The time series are fit with a multivariate linear/sinusoidal function to give the average rate of elevation change (dH/dt). On the major Rome-Filchner, Ross, and Amery ice shelves, the W d t are small or near zero. In contrast, the ice shelves of the Antarctic Peninsula and along the West Antarctic coast appear to be thinning significantly, with a 23 +/- 3 cm per year surface elevation decrease on the Larsen ice shelf and a 65 +/- 4 cm per year decrease on the Dotson ice shelf. On the grounded ice, significant elevation decreases are obtained over most of the drainage basins of the Pine Island and Thwaites glaciers in West Antarctica and inland of Law Dome in East Antarctica. Significant elevation increases are observed within about 200 km of the coast around much of the rest of the ice sheet. Farther inland, the changes are a mixed pattern of increases and decreases with increases of a few centimeters per year at the highest elevations of the East Antarctic plateau. The derived elevation changes are combined with estimates of the bedrock uplift from several models to provide maps of ice thickness change. The ice thickness changes enable estimates of the ice mass balances for the major drainage basins, the overall mass balance, and the current contribution of the ice sheet to global sea level change.

Zwally, H. Jay↗

An Evaluation of Recent Gravity Models wrt. Altimeter Satellite Missions

With the launch of CHAMP and GRACE, we have entered a new phase in the history of satellite geodesy. For the first time, geopotential models are now available based almost exclusively on satellite-satellite tracking either with GPS in the case of the CHAMP-based geopotential models, or co-orbital intersatellite ultra-precise ranging in the case of GRACE. Different groups have analyzed these data, and produced a series of geopotential models (e.g., EIGENlS, EIGEN2, GGM0lS, GGMOlC) that incorporate the new data. We will compare the performance of these "newer" geopotential models with the standard models now used for computations, (e.g., JGM-3, BGM-96, PGS7727, and GRIMS-C1) for TOPEX, JASON, Geosat-Follow-On (GFO), and Envisat using standard metrics such as SLR RMS of fit, altimeter crossovers, and orbit overlaps. Where covariances are available we can evaluate the predicted geographically correlated orbit error. These predicted results can be compared with the Earth-fixed differences between dynamic and reduced-dynamic orbits to test the predictive accuracy of the covariances, as well as to calibrate the error of the solutions.

Lemoine, Frank G.↗

ICESAT Laser Altimeter Pointing, Ranging and Timing Calibration from Integrated Residual Analysis

On January 12, 2003 the Ice, Cloud and land Elevation Satellite (ICESat) was successfully placed into orbit. The ICESat mission carries the Geoscience Laser Altimeter System (GLAS), which has a primary measurement of short-pulse laser- ranging to the Earth s surface at 1064nm wavelength at a rate of 40 pulses per second. The instrument has collected precise elevation measurements of the ice sheets, sea ice roughness and thickness, ocean and land surface elevations and surface reflectivity. The accurate geolocation of GLAS s surface returns, the spots from which the laser energy reflects on the Earth s surface, is a critical issue in the scientific application of these data. Pointing, ranging, timing and orbit errors must be compensated to accurately geolocate the laser altimeter surface returns. Towards this end, the laser range observations can be fully exploited in an integrated residual analysis to accurately calibrate these geolocation/instrument parameters. ICESat laser altimeter data have been simultaneously processed as direct altimetry from ocean sweeps along with dynamic crossovers in order to calibrate pointing, ranging and timing. The calibration methodology and current calibration results are discussed along with future efforts.

Luthcke, Scott B.↗

An Improved Model of the Crustal Structure of Mars

The first reliable model of the structure of the crust and upper mantle of Mars from remote observations was produced using data from the Mars Orbiter Laser Altimeter (MOLA) and the Radio Science investigation of Mars Global Surveyor (MGS). That model assumed a uniform crustal density and solved for the global variations in crustal thickness using a gravity field derived from preliminary MGS tracking. In that study, spherical harmonic potential coefficients were derived to degree and order 80, but crustal structure was interpreted cautiously to degree 60, or 360 km wavelength, owing to the presence of noise. Tracking normal equations have since been generated to degree 75, to degree 80 (supplemented by altimetric crossovers), and recently to degree 90, using new constants for the orientation of the spin pole and the rotation rate of Mars provided by the IAU2000 rotation model. Gravity models now incorporate tracking data coverage from the Primary and Extended MGS missions and the early phases of the Mars Odyssey mission. In the present study we exploit these advances in gravity modeling to present a refined crustal inversion, which we also interpret in the context of Mars' internal structure and thermal evolution.

Zuber, M. T.↗

ICESat Laser Altimeter Pointing, Ranging and Timing Calibration from Integrated Residual Analysis: A Summary of Early Mission Results

On January 12, 2003 the Ice, Cloud and land Elevation Satellite (ICESat) was successfully placed into orbit. The ICESat mission carries the Geoscience Laser Altimeter System (GLAS), which consists of three near-infrared lasers that operate at 40 short pulses per second. The instrument has collected precise elevation measurements of the ice sheets, sea ice roughness and thickness, ocean and land surface elevations and surface reflectivity. The accurate geolocation of GLAS's surface returns, the spots from which the laser energy reflects on the Earth's surface, is a critical issue in the scientific application of these data Pointing, ranging, timing and orbit errors must be compensated to accurately geolocate the laser altimeter surface returns. Towards this end, the laser range observations can be fully exploited in an integrated residual analysis to accurately calibrate these geolocation/instrument parameters. Early mission ICESat data have been simultaneously processed as direct altimetry from ocean sweeps along with dynamic crossovers resulting in a preliminary calibration of laser pointing, ranging and timing. The calibration methodology and early mission analysis results are summarized in this paper along with future calibration activities.

Scott B Luthcke↗

A Selected Operational History of the Internal Thermal Control System (ITCS) for International Space Station (ISS)

The Internal Thermal Control System (ITCS) has been developed jointly by Boeing Corporation, Huntsville, Alabama and Honeywell Engines & Systems, Torrance, California to meet the internal thermal control needs for the International Space Station (ISS). The ITCS provides heat removal for the critical life support systems and thermal conditioning for numerous experiment racks. The ITCS will be fitted on a number of modules on the ISS. The first US Element containing the ITCS, Node 1, was launched in December 1998. Since Node 1 does not contain a pump to circulate the fluid it was not filled with ITCS fluid until after the US Laboratory Module was installed. The second US Element module, US Laboratory Module, which contains the pumps and all the major ITCS control hardware, was launched in February 2001. The third US Element containing the ITCS, the US Airlock, was launched in July 2001. The dual loop system of the ITCS is comprised of a lowtemperature loop (LTL) and a moderate-temperature loop (MTL). Each loop has a pump package assembly (PPA), a system flow control assembly (SFCA), a threeway mixing valve (TWMV), several rack flow control assemblies (RFCA), cold plates, pressure sensors, temperature sensors, pump bypass assembly (PBA) and a heat exchanger. In addition, the MTL has an additional TWMV, a payload regeneration heat exchanger (P/RHE) and a manual flow control valve (MFCV). The LTL has a service performance and checkout unit (SPCU) heat exchanger. The two loops are linked via one loop crossover assembly (LCA) providing cross loop capabilities and a single PPA, two-loop functionality. One important parameter monitored by the ground stations and on-orbit is the amount of fluid leakage from the ITCS. ISS fluid leakage is of importance since ITCS fluid is costly to re-supply, may be difficult to clean up in zero-g, and if uncontained could lead to equipment failures and potential hazards. This paper examines the nominal leakage observed over period of a year of on-orbit operation and compares this with analysis predictions. This paper also addresses the off-nominal leakage and a fluid transfer event causing significant changes in accumulator quantity.

Patel, Vipul P.↗

The relation of motion sickness to the spatial-temporal properties of velocity storage

Tilting the head in roll to or from the upright while rotating at a constant velocity (roll while rotating, RWR) alters the position of the semicircular canals relative to the axis of rotation. This produces vertical and horizontal nystagmus, disorientation, vertigo, and nausea. With recurrent exposure, subjects habituate and can make more head movements before experiencing overpowering motion sickness. We questioned whether promethazine lessened the vertigo or delayed the habituation, whether habituation of the vertigo was related to the central vestibular time constant, i.e., to the time constant of velocity storage, and whether the severity of the motion sickness was related to deviation of the axis of eye velocity from gravity. Sixteen subjects received promethazine and placebo in a double-blind, crossover study in two consecutive 4-day test series 1 month apart, termed series I and II. Horizontal and vertical eye movements were recorded with video-oculography while subjects performed roll head movements of approx. 45 degrees over 2 s to and from the upright position while being rotated at 138 degrees /s around a vertical axis. Motion sickness was scaled from 1 (no sickness) to an endpoint of 20, at which time the subject was too sick to continue or was about to vomit. Habituation was determined by the number of head movements that subjects made before reaching the maximum motion sickness score of 20. Head movements increased steadily in each session with repeated testing, and there was no difference between the number of head movements made by the promethazine and placebo groups. Horizontal and vertical angular vestibulo-ocular reflex (aVOR) time constants declined in each test, with the declines being closely correlated to the increase in the number of head movements. The strength of vertiginous sensation was associated with the amount of deviation of the axis of eye velocity from gravity; the larger the deviation of the eye velocity axis from gravity, the more severe the motion sickness. Thus, promethazine neither reduced the nausea associated with RWR, nor retarded or hastened habituation. The inverse relationship between the aVOR time constants and number of head movements to motion sickness, and the association of the severity of motion sickness with the extent, strength, and time of deviation of eye velocity from gravity supports the postulate that the spatiotemporal properties of velocity storage, which are processed between the nodulus and uvula of the vestibulocerebellum and the vestibular nuclei, are likely to represent the source of the conflict responsible for producing motion sickness.

NASA Discipline Neuroscience↗

Lower-body negative-pressure exercise and bed-rest-mediated orthostatic intolerance

PURPOSE: Supine, moderate exercise is ineffective in maintaining orthostatic tolerance after bed rest (BR). Our purpose was to test the hypothesis that adding an orthostatic stress during exercise would maintain orthostatic function after BR. METHODS: Seven healthy men completed duplicate 15-d 6 degrees head-down tilt BR using a crossover design. During one BR, subjects did not exercise (CON). During another BR, subjects exercised for 40 min.d(-1) on a supine treadmill against 50-60 mm Hg LBNP (EX). Exercise training consisted of an interval exercise protocol of 2- to 3-min intervals alternating between 41 and 65% (.)VO(2max). Before and after BR, an LBNP tolerance test was performed in which the LBNP chamber was decompressed in 10-mm Hg stages every 3 min until presyncope. RESULTS: LBNP tolerance, as assessed by the cumulative stress index (CSI) decreased after BR in both the CON (830 +/- 144, pre-BR vs 524 +/- 56 mm Hg.min, post-BR) and the EX (949 +/- 118 pre-BR vs 560 +/- 44 mm Hg.min, post-BR) conditions. However, subtolerance (0 to -50 mm Hg LBNP) heart rates were lower and systolic blood pressures were better maintained after BR in the EX condition compared with CON. CONCLUSION: Moderate exercise performed against LBNP simulating an upright 1-g environment failed to protect orthostatic tolerance after 15 d of BR.

NASA Center JSC↗

Human otolith-ocular reflexes during off-vertical axis rotation: effect of frequency on tilt-translation ambiguity and motion sickness

The purpose of this study was to examine how the modulation of tilt and translation otolith-ocular responses during constant velocity off-vertical axis rotation varies as a function of stimulus frequency. Eighteen human subjects were rotated in darkness about their longitudinal axis 30 degrees off-vertical at stimulus frequencies between 0.05 and 0.8 Hz. The modulation of torsion decreased while the modulation of horizontal slow phase velocity (SPV) increased with increasing frequency. It is inferred that the ambiguity of otolith afferent information is greatest in the frequency region where tilt (torsion) and translational (horizontal SPV) otolith-ocular responses crossover. It is postulated that the previously demonstrated peak in motion sickness susceptibility during linear accelerations around 0.3 Hz is the result of frequency segregation of ambiguous otolith information being inadequate to distinguish between tilt and translation.

NASA Discipline Neuroscience↗

Selective norepinephrine reuptake inhibition as a human model of orthostatic intolerance

BACKGROUND: Observations in patients with functional mutations of the norepinephrine transporter (NET) gene suggest that impaired norepinephrine uptake may contribute to idiopathic orthostatic intolerance. METHODS AND RESULTS: We studied the effect of the selective NET blocker reboxetine and placebo in a randomized, double-blind, crossover fashion on cardiovascular responses to cold pressor testing, handgrip testing, and a graded head-up tilt test (HUT) in 18 healthy subjects. In a subset, we determined isoproterenol and phenylephrine sensitivities. Subjects ingested 8 mg reboxetine or placebo 12 hours and 1 hour before testing. In the supine position, heart rate was 65+/-2 bpm with placebo and 71+/-3 bpm with reboxetine. At 75 degrees HUT, heart rate was 84+/-3 and 119+/-4 bpm with placebo and with reboxetine (P<0.0001). Mean arterial pressure was 85+/-2 with placebo and 91+/-2 mm Hg with reboxetine while supine (P<0.01) and 88+/-2 mm Hg and 90+/-3 mm Hg at 75 degrees HUT. Blood pressure responses to cold pressor and handgrip testing were attenuated with reboxetine. Reboxetine increased the sensitivity to the chronotropic effect of isoproterenol and the pressor effect of phenylephrine. Vasovagal reactions occurred in 9 subjects on placebo and in 1 subject on reboxetine. CONCLUSIONS: Selective NET blockade creates a phenotype that resembles idiopathic orthostatic intolerance. This observation supports the hypothesis that disordered norepinephrine uptake mechanisms can contribute to human cardiovascular disease. Our study also suggests that NET inhibition might be useful in preventing vasovagal reactions.

Non-NASA Center↗