Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic fluid transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

CFM technologies for space transportation: Multipurpose hydrogen testbed system definition and tank procurement

The development of a test bed tank and system for evaluating cryogenic fluid management technologies in a simulated upper stage liquid hydrogen tank is covered. The tank is 10 ft long and is 10 ft in diameter, and is an ASME certified tank constructed of 5083 aluminum. The tank is insulated with a combination of sprayed on foam insulation, covered by 45 layers of double aluminized mylar separated by dacron net. The mylar is applied by a continuous wrap system adapted from commercial applications, and incorporates variable spacing between the mylar to provide more space between those layers having a high delta temperature, which minimizes heat leak. It also incorporates a unique venting system which uses fewer large holes in the mylar rather than the multitude of small holes used conventionally. This significantly reduces radiation heat transfer. The test bed consists of an existing vacuum chamber at MSFC, the test bed tank and its thermal control system, and a thermal shroud (which may be heated) surrounding the tank. Provisions are made in the tank and chamber for inclusion of a variety of cryogenic fluid management experiments.

Fox, E. C.↗

Cryogenic Propellant Storage and Transfer Technology Demonstration For Long Duration In-Space Missions

The high specific impulse of cryogenic propellants can provide a significant performance advantage for in-space transfer vehicles. The upper stages of the Saturn V and various commercial expendable launch vehicles have used liquid oxygen and liquid hydrogen propellants; however, the application of cryogenic propellants has been limited to relatively short duration missions due to the propensity of cryogens to absorb environmental heat resulting in fluid losses. Utilizing advanced cryogenic propellant technologies can enable the efficient use of high performance propellants for long duration missions. Crewed mission architectures for beyond low Earth orbit exploration can significantly benefit from this capability by developing realistic launch spacing for multiple launch missions, by prepositioning stages and by staging propellants at an in-space depot. The National Aeronautics and Space Administration through the Office of the Chief Technologist is formulating a Cryogenic Propellant Storage and Transfer Technology Demonstration Mission to mitigate the technical and programmatic risks of infusing these advanced technologies into the development of future cryogenic propellant stages or in-space propellant depots. NASA is seeking an innovative path for human space exploration, which strengthens the capability to extend human and robotic presence throughout the solar system. This mission will test and validate key cryogenic technological capabilities and has the objectives of demonstrating advanced thermal control technologies to minimize propellant loss during loiter, demonstrating robust operation in a microgravity environment, and demonstrating efficient propellant transfer on orbit. The status of the demonstration mission concept development, technology demonstration planning and technology maturation activities in preparation for flight system development are described.

Meyer, Michael L.↗

NASA OAST perspective

An advanced OTV is one of a number of advanced STS vehicles that the NASA OAST Space Systems Division Transportation Systems Office identified as candidates for future vehicle development. Vehicle requirements as well as technology needs and need dates were established and technology programs initiated to support those potential developments in a timely manner. It is assumed that advanced OTV will be space based and fully reusable for low cost operations, use aeroassist for return to low-Earth-orbit, and evolve to a man-rated system. The propulsion system will need to maintain high performance over a wide thrust range for mission flexibility, ranging from the transfer of large, acceleration limited structures from LEO to GEO, to demanding high reliability round-trip manned missions. Technology advances are needed in propulsion, aerobraking, low-gravity cryogenic fluid management, and in environmentally compatible, low-loss cryogenic tankage. In addition, diagnostic instrumentation for monitoring the health of on-board components and systems, and automated check-out capability will enhance low-cost space based OTV operations.

Stephenson, F.↗

Modeling and Analysis of Chill and Fill Processes for the EDU Tank

NASA's future missions may require long-term storage and transfer of cryogenic propellants. The Engineering Development Unit (EDU), a NASA in-house effort supported by both Marshall Space Flight Center (MSFC) and Glenn Research Center (GRC), is a Cryogenic Fluid Management (CFM) test article that primarily serves as a manufacturing pathfinder and a risk reduction task for a future CFM payload. The EDU test article, comprises a flight like tank, internal components, insulation, and attachment struts. The EDU is designed to perform integrated passive thermal control performance testing with liquid hydrogen in a space-like vacuum environment. A series of tests, with liquid hydrogen as a testing fluid, was conducted at Test Stand 300 at MSFC during summer of 2014. The objective of this effort was to develop a thermal/fluid model for evaluating the thermodynamic behavior of the EDU tank during the chill and fill processes. Generalized Fluid System Simulation Program (GFSSP), an MSFC in-house general-purpose computer program for flow network analysis, was utilized to model and simulate the chill and fill portion of the testing. The model contained the liquid hydrogen supply source, feed system, EDU tank, and vent system. The modeling description and comparison of model predictions with the test data will be presented in the final paper.

Hedayat, A.↗

Validation of a Two-Phase CFD Model for Predicting Propellant Tank Pressurization and Pressure Collapse in The Ground-Based K-Site Hydrogen Slosh Experiment

A two-phase CFD model for tank pressurization and following sloshing in a cryogenic storage tank partially filled with liquid hydrogen is presented using the Volume-Of-Fluid approach for representing the phase boundary and the associated interfacial heat, mass and momentum transfer between the liquid and the vapor regions. The CFD model was validated against pressurization and sloshing data for a 62 cubic foot tank provided by Moran et al. Cases with different sloshing amplitudes and frequencies are studied. The results of modeling tank pressurization are presented first followed by the results of sloshing cases. Predicted tank pressures are compared with the experimental data.

Computational Fluid Dynamics↗

Validation of a Two-Phase CFD Model for Predicting Propellant Tank Pressurization and Pressure Collapse in the Ground-Based K-Site Hydrogen Slosh Experiment

A two-phase CFD model for tank pressurization and following sloshing in a cryogenic storage tank partially filled with liquid hydrogen is presented using the Volume-Of-Fluid approach for representing the phase boundary and the associated interfacial heat, mass and momentum transfer between the liquid and the vapor regions. The CFD model was validated against pressurization and sloshing data for a 62 cubic foot tank provided by Moran et al. Cases with different sloshing amplitudes and frequencies are studied. The results of modeling tank pressurization are presented first followed by the results of sloshing cases. Predicted tank pressures are compared with the experimental data.

Computational Fluid Dynamics↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Cryogenic Fluid Management: 2000-2004

This custom bibliography from the NASA Scientific and Technical Information Program lists a sampling of records found in the NASA Aeronautics and Space Database. The scope of this topic includes cooling technologies for precision astronomical sensors and advanced spacecraft, as well as propellant storage and transfer in space. This area of focus is one of the enabling technologies as defined by NASA's Report of the President's Commission on Implementation of United States Space Exploration Policy, published in June 2004.

Source record↗

Cryogenic fluid management program at MSFC

Cryogenic fluid management (CFM) is an important aspect in the design and operation of spacecraft propellant systems. Consequently, it represents a key technology in the development of future vehicles for orbital transfer, lunar transit and manned interplanetary (i.e., Mars) missions. Because of Marshall Space Flight Center's (MSFC's) leading role in the definition of such vehicles, the center is currently managing and conducting a variety of tests to support development of this technology. The purpose of this paper is to summarize these activities and present their status within the context of CFM technology requirements. The first section reviews MSFC's role, identifies the major emphases and thrusts of its program, and presents the overall schedule. The final part comprises the bulk of the report, and describes at length the objectives, approach and status of each project.

Schmidt, G. R.↗

Joule-Thomson Cryogenic Nitrogen Orifice Flows

The Joule-Thomson Effect involves the expansion of a fluid through a throttling device, often a simple orifice, resulting in a change in the fluid's temperature. It has been leveraged in the design and analysis of Thermodynamic Vent Systems and integrated into injector designs for cryogenic no-vent fill tank-to-tank transfer testing. There is a scarcity of comprehensive data available to model the phenomenon effectively using tools such as GFSSP for cryogenic nitrogen flows. This experiment aims to model the Joule-Thomson effect of liquid nitrogen through seven traditionally manufactured, sharp-edged orifices manufactured by O’Keefe and three additively manufactured (AM) orifices manufactured by Cumberland Additive. The traditional orifice sizes were 0.016, 0.02, 0.024, 0.032, 0.037, and 0.04 inch in diameter. The three additive orifices had diameters with target/nominal sizes equal to the 0.016, 0.024, and 0.04 inch O’Keefe orifices. However, the actual diameters of the AM orifices were found to be 0.014, 0.024, and 0.035 inches due to additive manufacturing restrictions. Water was flowed through the orifices to verify that their flow coefficients matched published values and to establish flow coefficients for the AM orifices. Liquid nitrogen was flowed through the orifices in a separate test apparatus. The liquid nitrogen started as a subcooled liquid upstream of the orifice and transitioned into a two-phase gas-liquid mixture after passing through each orifice. The upstream pressure was set to 29 psia, 34 psia, 39 psia, and/or 42 psia or 44 psia. The pressure, temperature, and flow rate were measured upstream and downstream of the orifice for three trials at each set point. The average volumetric flow rate and Joule-Thomson Coefficients were calculated from this data. The AM orifices and traditionally manufactured orifices displayed similar results. This data will refine the dataset GFSSP uses to model the J-T Effect more accurately.

Joule-Thomson↗

A Summary of Recent SBIR and STTR Projects in Support of Cryogenic Fluid Management Modeling

Over the last five years, NASA has invested in development of sub-models to improve the current capabilities of Computational Fluid Dynamics (CFD) codes utilized for cryogenic fluid management (CFM) predictions. The goal is for the submodels to be modular so that they can easily be implemented into NASA’s CFD codes such as ANSYS Fluent, Siemens STAR-CCM+, and Streamline Numerics Loci-Stream. These technologies are being developed through Small Business Innovative Research (SBIR) and Small Business Technology Transfer (STTR) contracts under the CFM subtopic solicitation and funded by the CFM Portfolio Project. All contracts presented include cryogenic experiments to enable model validation. A sub-grid boiling model has been developed by Combustion Research and Flow Technology Inc. and Massachusetts Institute of Technology for cryogenic line chilldown predictions and has completed Phase III. A spray chill-and-fill model for cryogenic tankage is being developed by Combustion Research and Flow Technology Inc. and University of Connecticut and is currently in Phase II. Last, film condensation modeling to support cryogenic liquefaction was progressed through a Phase I contract with Combustion Research and Flow Technology Inc. and University of Connecticut. A summary of accomplishments for each contract is presented.

cryogenics↗

The COLD-SAT program

The Cryogenic On-Orbit Liquid Depot Storage, Acquisition and Transfer (COLD-SAT) satellite is an experimental spacecraft launched from an expendable launch vehicle which is designed to investigate the systems and technologies required for efficient and reliable management of cryogenic fluid in the reduced-gravity space environment. Future applications such as Space Station, Space Transportation Vehicle (STV), external tank (ET), aft cargo carrier (ACC) propellant scavenging, storage depots, and lunar and interplanetary missions, among others, have provided the impetus to pursue this technology in a timely manner to support the design efforts. A refined conceptual approach has been developed and an overview of the COLD-SAT program is described which includes the following: (1) a definition of the technology needs and the accompanying experimental six-month baseline mission; (2) a description of the experiment subsystem, major features, and rationale for satisfaction of primary and secondary experiment requirements using LH2 as the test fluid; and (3) a presentation of the conceptual design of the COLD-SAT spacecraft subsystems which support the on-orbit experiment with emphasis on those areas which posed the greatest technical challenge.

Bailey, William J.↗

Thermal Analysis of Magnetically-Coupled Pump for Cryogenic Applications

Magnetically-coupled pump is under evaluation at Kennedy Space Center for possible cryogenic applications. A major concern is the impact of low temperature fluid flows on the pump performance. As a first step toward addressing this and related issues, a computational fluid dynamics and heat transfer tool has been adopted in a pump geometry. The computational tool includes (i) a commercial grid generator to handle multiple grid blocks and complicated geometric definitions, and (ii) an in-house computational fluid dynamics and heat transfer software developed in the Principal Investigator's group at the University of Florida. Both pure-conduction and combined convection-conduction computations have been conducted. A pure-conduction analysis gives insufficient information about the overall thermal distribution. Combined convection-conduction analysis indicates the significant influence of the coolant over the entire flow path. Since 2-D simulation is of limited help, future work on full 3-D modeling of the pump using multi-materials is needed. A comprehensive and accurate model can be developed to take into account the effect of multi-phase flow in the cooling flow loop, and the magnetic interactions.

Senocak, Inanc↗

Maglev Facility for Simulating Variable Gravity

An improved magnetic levitation apparatus ("Maglev Facility") has been built for use in experiments in which there are requirements to impose variable gravity (including zero gravity) in order to assess the effects of gravity or the absence thereof on physical and physiological processes. The apparatus is expected to be especially useful for experiments on the effects of gravity on convection, boiling, and heat transfer in fluids and for experiments on mice to gain understanding of bone loss induced in human astronauts by prolonged exposure to reduced gravity in space flight. The maglev principle employed by the apparatus is well established. Diamagnetic cryogenic fluids such as liquid helium have been magnetically levitated for studying their phase transitions and critical behaviors. Biological entities consist mostly of diamagnetic molecules (e.g., water molecules) and thus can be levitated by use of sufficiently strong magnetic fields having sufficiently strong vertical gradients. The heart of the present maglev apparatus is a vertically oriented superconducting solenoid electromagnet (see figure) that generates a static magnetic field of about 16 T with a vertical gradient sufficient for levitation of water in normal Earth gravity. The electromagnet is enclosed in a Dewar flask having a volume of 100 L that contains liquid helium to maintain superconductivity. The Dewar flask features a 66-mm-diameter warm bore, lying within the bore of the magnet, wherein experiments can be performed at room temperature. The warm bore is accessible from its top and bottom ends. The superconducting electromagnet is run in the persistent mode, in which the supercurrent and the magnetic field can be maintained for weeks with little decay, making this apparatus extremely cost and energy efficient to operate. In addition to water, this apparatus can levitate several common fluids: liquid hydrogen, liquid oxygen, methane, ammonia, sodium, and lithium, all of which are useful, variously, as rocket fuels or as working fluids for heat transfer devices. A drop of water 45 mm in diameter and a small laboratory mouse have been levitated in this apparatus.

Liu, Yuanming↗

Modeling the Rapid Boil-Off of a Cryogenic Liquid When Injected into a Low Pressure Cavity

Many launch vehicle cryogenic applications require the modeling of injecting a cryogenic liquid into a low pressure cavity. The difficulty of such analyses lies in accurately predicting the heat transfer coefficient between the cold liquid and a warm wall in a low pressure environment. The heat transfer coefficient and the behavior of the liquid is highly dependent on the mass flow rate into the cavity, the cavity wall temperature and the cavity volume. Testing was performed to correlate the modeling performed using Thermal Desktop and Sinda Fluint Thermal and Fluids Analysis Software. This presentation shall describe a methodology to model the cryogenic process using Sinda Fluint, a description of the cryogenic test set up, a description of the test procedure and how the model was correlated to match the test results.

Fluid Mechanics↗

Mastering the Cryogenic Frontier: Predicting Sloshing in Cryogenic Propellant Tanks

In recent years, NASA has undertaken the development and validation of computation fluid dynamic (CFD) models for predicting cryogenic two-phase sloshing within propellant tanks. These models have been rigorously anchored against cryogenic ground tests that induce sloshing, as well as limited microgravity tests. The primary focus of these models is to accurately predict the two-phase condensation and, at times, evaporation within the cryogenic propellant. This approach is important for estimating the required autogenous and/or helium pressurant for completing propulsion system burns or ensuring adequate pressure for in-space propellant transfers. Unlike in hypergolic propulsion systems, where the propellant is stored at room temperature, cryogenic propellant is highly volatile. Therefore, ensuring the accurate estimation of pressurant necessitates the precise modeling of two-phase interfacial heat and mass transfer processes. This paper aims to provide an overview of NASA’s continuing efforts in developing and validating these CFD models, with particular emphasis on benchmark cases with sloshing that enhances phase change, tracing their historical development, and demonstrating their predictive accuracy when compared to test results.

low-gravity fluid modeling↗

Cryogenic Autogenous Pressurization Testing for Robotic Refueling Mission 3

A wick-heater system has been selected for use to pressurize the Source Dewar of the Robotic Refueling Mission Phase 3 on-orbit cryogen transfer experiment payload for the International Space Station. Experimental results of autogenous pressurization of liquid argon and liquid nitrogen using a prototype wick-heater system are presented. The wick-heater generates gas to increase the pressure in the tank while maintaining a low bulk fluid temperature. Pressurization experiments were performed in 2013 to characterize the performance of the wick heater. This paper describes the experimental setup, pressurization results, and analytical model correlations.

cryogenics↗

Thermal subcoolers for low-thrust chemical orbital transfer vehicles

A system alternative to pressurization for providing net positive suction pressure (NPSP) to the main engine of a low-thrust cryogenic stage has been conceptually designed and analyzed. Thermal subcoolers (heat exchangers) provide required NPSP levels by using throttled vent fluid to subcool propellant delivered to the engine. The study analyzed and sized subcoolers that provide NPSP levels of 0.5 to 12.0 psi for liquid oxygen, liquid hydrogen, and liquid methane propellants. The study was part of an overall investigation to compare pressurization and other methods of providing NPSP for low-thrust vehicles.

Pleasant, R. L.↗