Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Simulations of Zero Boiloff, Densification, and Solidification in a Large-Scale Liquid Hydrogen Tank

The current research utilizes an Energy of Fluid (EOF) approach to develop a finite volume-based Computation Fluid Dynamic (CFD) model to create a benchmark simulation of the densification of liquid hydrogen (LH2) in an experimental Integrated Refrigeration and Storage (IRAS) tank at the Kennedy Space Center (KSC). The computational code will incorporate the FLUENT pressure-based model with User Defined Functions (UDF) to implement the EOF model. The enhanced model will solve the energy equation in terms of internal energy and provide temperature and pressure calculations for a given tank geometry. Specifically, a convection term will be added to an already existing code for a more accurate simulation of LH2 densification. However, currently the research focuses on utilizing User Defined Scalars (UDS) with FLUENT to show the built-in solvers are as accurate as the written UDS. This will reduce the computational time down significantly by utilizing an already built in solver for the momentum equation. A custom UDF has been written to solve transient and steady state conduction, and results obtained using the UDF agree with results obtained using the built-in FLUENT solver. Currently, a convection UDF is being added and will be verified using known solutions for solidification and validated with the experimental results from the Cryogenics Test Laboratory (CTL) at KSC for the IRAS densification process.

Colin Philip Mahony↗

Diamond-Loaded Polyimide Aerogel Scattering Filters and Their Applications in Astrophysical and Planetary Science Observations

Infrared-blocking, aerogel-based scattering filters have a broad range of potential applications in astrophysics and planetary science instruments in the far-infrared, sub-millimeter, and microwave regimes. This paper demonstrates the ability of conductively-loaded, polyimide aerogel filters to meet the mechanical and science instrument requirements for several experiments, including the Cosmology Large Angular Scale Surveyor (CLASS), the Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM), and the Sub-millimeter Solar Observation Lunar Volatiles Experiment (SSOLVE). Thermal multi-physics simulations of the filters predict their performance when integrated into a cryogenic receiver. Prototype filters have survived cryogenic cycling to 4 K with no degradation in mechanical properties. Measurement of total hemispherical reflectance and transmittance, as well as cryogenic tests of the aerogel filters in a full receiver context, allow estimates of the integrated infrared emissivity of the filters. Knowledge of the emissivity will help instrument designers incorporate the filters into future experiments in planetary science, astrophysics, and cosmology.

Kyle R Helson↗

Development of a half-meter scale Traveling-Wave (TW) SRF cavity

Traveling-wave technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the fundamental limit of 50~60MV/m in Standing-Wave regime. The 1st demonstration of TW resonance excitation in a proof-of-principle 3-cell SRF cavity in 2K liquid helium was successfully carried out at Fermilab in collaboration with Euclid Techlabs. In parallel with that, the RF design process of 0.5~1 meter scale TW cavity was begun at Fermilab for advancing TW technologies necessary more for future accelerator-scale one. Considering the physical dimensions of existing SRF facilities (for fabrication, processing, and cryogenic testing) and the lessons learned from the 3-cell, Fermilab has proposed a preliminary RF design of a half-meter scale TW SRF cavity. It consists of a 7-cell structure and a power feedback waveguide (WG) loop with new RF configurations to control TW resonance. Here we report a preliminary RF design, development plans, and activities.

43 PARTICLE ACCELERATORS↗

Understanding the Role of Extrinsic Impurities in Bulk Nb SRF Cavities

High gradient and high quality factor superconducting radiofrequency (SRF) cavities are essential for efficient particle acceleration in next-generation accelerators. This work demonstrates that the superconducting performance of bulk niobium can be enhanced through a controlled introduction of interstitial oxygen and nitrogen. Thermal and chemical surface treatments modify the concentration and distribution of these impurities, enabling systematic tuning of SRF cavity performance. By combining cavity RF measurements with quantitative materials characterizations, we isolate the impact of impurity concentration on BCS surface resistance and identify the mechanisms by which interstitial impurities alter the superconducting properties of niobium. We find that nitrogen is an order of magnitude more effective than oxygen in reducing BCS resistance at 16 MV/m and that the reduction arises from a combination of mean free path optimization and superconducting gap enhancement. Using these insights, we develop a predictive model that estimates cavity performance directly from room temperature sample material studies, reducing the reliance on full-scale cryogenic tests for surface treatment development. We then apply this model to explore co-doping strategies, demonstrating that combining interstitial oxygen and nitrogen achieves a synergistic reduction in BCS resistance. These results establish co-doping as a viable path for the development of surface-engineered niobium for future high quality factor SRF applications.

Hu, Hannah [Chicago U.]↗

Design, development and testing of a cryogenic temperature heat pipe for the icicle system

An analytical model was formulated for a cryogenic heat pipe, and thermal and transport analyses were developed to predict the performance characteristics of various heat pipe designs. These analyses permitted optimization of various design parameters. A series of four breadboard heat pipes were fabricated and tested to provide inputs such as internal film coefficients, minimum capillary radii, and wick permeabilities which are required for the analyses. The results of instrumentation, charging, and testing of cryogenic heat pipes were applied to the prototype heat pipes. After a thorough design analysis of three potential heat pipe wicks (slab, artery, and axial groove), the first two were chosen for application to two prototype heat pipes. Detailed designs were made of the two heat pipes and the units were fabricated. Tests were conducted which verified the integrity and safety margin of the design to withstand the internal pressure at ambient temperature and fatigue of thermal cycling. During the acceptance testing in the vacuum chamber, no difficulty was experienced in priming the slab-wick heat pipe and it met the performance design requirements. The artery-wick heat pipe would not prime with nitrogen working fluid for any test conditions.

Trimmer, D. S.↗

Operating and Maintaining the JWST Cleanroom attached to JSC's Chamber A during preparations for the OTIS Cryogenic Thermal Vacuum Test

In order to maintain cleanliness during preparations for JWST’s OTIS (Optical Telescope Element-Integrated Science Instrument Module) Cryogenic Thermal Vacuum Test, a cleanroom was built that attached directly to the 60-year-old Chamber A. The cleanroom and chamber were outfitted with independent environmental control systems each providing ISO Class 71 air cleanliness. To maintain balanced, positive pressure in both the cleanroom and chamber volumes, a special control protocol was developed and successfully implemented. Dual back-up environmental control units (one each for the chamber and cleanroom) were installed just outside the building to provide environmental control redundancy due to a single source chilled water supply and weather threats. In addition, lack of a dedicated cleanroom airlock facilitating clean ingress and egress made it necessary to perform additional cleaning and packaging, as well as augment the uncontrolled truck lock space with small clean tents for pre-cleaning. Special procedures were developed to allow ingress of extra-large support equipment required for load testing of the cleanroom crane, installation of optical equipment in Chamber A and accommodation of the OTIS shipping container. A thorough bake-out and cleaning of Chamber A was also necessary to reduce volatiles from the shroud’s black thermal paint and to reduce particle fallout. Acrylic adhesive fracture discovered during early cryo-testing represented a significant challenge that was successfully mitigated prior to OTIS testing. A dedicated team of Contamination Control (CC) Technicians was specifically trained to clean support equipment and screen materials entering the cleanroom and chamber to ensure cleanliness and vacuum compatibility.

Optics↗

Operating and Maintaining the JWST Cleanroom attached to JSC's Chamber A during preparations for the OTIS Cryogenic Thermal Vacuum Test

In order to maintain cleanliness during preparations for JWST’s OTIS (Optical Telescope Element-Integrated Science Instrument Module) Cryogenic Thermal Vacuum Test, a cleanroom was built that attached directly to the 60-year-old Chamber A. The cleanroom and chamber were outfitted with independent environmental control systems each providing ISO Class 71 air cleanliness. To maintain balanced, positive pressure in both the cleanroom and chamber volumes, a special control protocol was developed and successfully implemented. Dual back-up environmental control units (one each for the chamber and cleanroom) were installed just outside the building to provide environmental control redundancy due to a single source chilled water supply and weather threats. In addition, lack of a dedicated cleanroom airlock facilitating clean ingress and egress made it necessary to perform additional cleaning and packaging, as well as augment the uncontrolled truck lock space with small clean tents for pre-cleaning. Special procedures were developed to allow ingress of extra-large support equipment required for load testing of the cleanroom crane, installation of optical equipment in Chamber A and accommodation of the OTIS shipping container. A thorough bake-out and cleaning of Chamber A was also necessary to reduce volatiles from the shroud’s black thermal paint and to reduce particle fallout. Acrylic adhesive fracture discovered during early cryo-testing represented a significant challenge that was successfully mitigated prior to OTIS testing. A dedicated team of Contamination Control (CC) Technicians was specifically trained to clean support equipment and screen materials entering the cleanroom and chamber to ensure cleanliness and vacuum compatibility.

James Webb Space Telescope↗

No-vent fill pressurization tests using a cryogen simulant

The results are described of an experimental program which studied the performance of various no-vent fill techniques for tank-to-tank liquid transfer. The tests were performed using a cryogen simulant (Freon-114) and a test bed consisting of a multiple tank/plumbing network that enabled studies of a variety of different inlet flow and active mixing regimes. Several results and conclusions were drawn from the 26 transfer experiments comprising the program. Most notable was the significant improvement in fill performance (i.e., minimized fill time and maximized fill fraction) with increased agitation of the liquid surface. Another was the close correlation between measured condensation rates and those predicted by recent theories which express condensation as a function of turbulent eddy effects on the liquid surface. In most cases, test data exhibited strong agreement with an analytical model which accounts for tank heat transfer and thermodynamics in a 1 g environment.

Schmidt, G. R.↗

No-vent fill pressurization tests using a cryogen simulant

The results are described of an experimental program which studied the performance of various no-vent fill techniques for tank-to-tank liquid transfer. The tests were performed using a cryogen simulant (Freon-114) and a test bed consisting of a multiple tank/plumbing network that enabled studies of a variety of different inlet flow and active mixing regimes. Several results and conclusions were drawn from the 26 transfer experiments comprising the program. Most notable was the significant improvement in fill performance (i.e., minimized fill time and maximized fill fraction) with increased agitation of the liquid surface. Another was the close correlation between measured condensation rates and those predicted by recent theories which express condensation as a function of turbulent eddy effects on the liquid surface. In most cases, test data exhibited strong agreement with an analytical model which accounts for tank heat transfer and thermodynamics in a 1 g environment.

Schmidt, G.↗

Design and Testing of a Cryogenic Capillary Pumped Loop Flight Experiment

This paper details the flight configuration and pre-flight performance test results of the fifth generation cryogenic capillary pumped loop (CCPL-5). This device will fly on STS-95 in October 1998 as part of the CRYOTSU Flight Experiment. This flight represents the first in-space demonstration of a CCPL, a miniaturized two-phase fluid circulator for thermally linking cryogenic cooling sources to remote cryogenic components. CCPL-5 utilizes N2 as the working fluid and has a practical operating range of 75-110 K. Test results indicate that CCPL-5, which weighs about 200 grams, can transport over 10 W of cooling a distance of 0.25 m (or more) with less than a 5 K temperature drop.

Bugby, David C.↗

Design and Testing of a Cryogenic Capillary Pumped Loop Flight Experiment

This paper details the flight configuration and pre-flight performance test results of the fifth generation cryogenic capillary pumped loop (CCPL-5). This device will fly on STS-95 in October 1998 as part of the CRYOTSU Flight Experiment. This flight represents the first in-space demonstration of a CCPL; a miniaturized two-phase fluid circulator for thermally linking cryogenic components. CCPL-5 utilizes N2 as the working fluid and has a practical operating range of 75-110 K. Test results indicate that CCPL-5, which weighs about 200 grams, can transport over 10 W of cooling a distance of 0.25 m (or more) with less than a 5 K temperature drop.

Bugby, David C.↗

Pressure distributions from high Reynolds number transonic tests of an NACA 0012 airfoil in the Langley 0.3-meter transonic cryogenic tunnel

Tests were conducted in the 2-D test section of the Langley 0.3-meter Transonic Cryogenic Tunnel on a NACA 0012 airfoil to obtain aerodynamic data as a part of the Advanced Technology Airfoil Test (ATAT) program. The test program covered a Mach number range of 0.30 to 0.82 and a Reynolds number range of 3.0 to 45.0 x 10 to the 6th power. The stagnation pressure was varied between 1.2 and 6.0 atmospheres and the stagnation temperature was varied between 300 K and 90 K to obtain these test conditions. Tabulated pressure distributions and integrated force and moment coefficients are presented as well as plots of the surface pressure distributions. The data are presented uncorrected for wall interference effects and without analysis.

Ladson, Charles L.↗

High Reynolds number transonic tests on a NACA 0012 airfoil in the Langley 0.3-meter transonic cryogenic tunnel

Tests were conducted in the two-dimensional test section of the Langley 0.3-m Transonic Cryogenic Tunnel on a NACA 0012 airfoil to obtain aerodynamic data as a part of the Advanced Technology Airfoil Test (ATAT) program. The test program covered a Mach number range of 0.30 to 0.82 and a Reynolds number range of 3.0 to 45.0 x 10 to the 6th. The stagnation pressure was varied between 1.2 and 6.0 atmospheres and the stagnation temperature was varied between 300 K and 90 K to obtain these test conditions. Plots of the spanwise variation of drag coefficient as a function of normal force coefficient and the variation of the basic aerodynamic characteristics with angle of attack are shown. The data are presented uncorrected for wall interference effects and without analysis.

Ladson, Charles L.↗

Development Tests of a Cryogenic Filter Wheel Assembly for the NIRCam Instrument

The James Webb Space Telescope is an infrared-optimized space telescope scheduled for launch in 201 3. Its 6.5-m diameter primary mirror will collect light from some of the first galaxies formed after the big bang. The Near Infrared camera (NIRCam) will detect the first light from these galaxies, provide the necessary tools for studying the formation of stars, aid in discovering planets around other stars, and adjust the wave front error on the primary mirror (Fig. 1). The instrument and its complement of mechanisms and optics will operate at a cryogenic temperature of 35 K. This paper describes tests and test results of the NIRCam Filter Wheel assembly prototype.

McCully, Sean↗

Exploratory flutter test in a cryogenic wind tunnel

A model consisting of a rigid wing with an integral, flexible beam support that was cantilever mounted from the wall in the NASA LaRC 0.3-m transonic cryogenic tunnel was used in a flutter analysis study. The wing had a rectangular planform of aspect ratio 1.5 and a 64A010 airfoil. Various considerations and procedures for conducting flutter tests in a cryogenic wind tunnel were evaluated. Flutter onset conditions were established from extrapolated subcritical response measurements. A flutter boundary was determined at cryogenic temperatures over a Mach number M range from 0.5 to 0.9. Flutter was obtained at two different Reynolds numbers R at M = 0.5 (R = 4.4 and 18.4 x 10 to the 6th power) and at M = 0.8 (R = 5.0 and 10.4 x 10 to the 6th power). Flutter analyses using subsonic lifting surface (kernel function) aerodynamics were made over the range of test conditions. To evaluate the Reynolds number effects at M = 0.5 and 0.8, the experimental results were adjusted using analytical trends to account for differences in the model test temperatures and mass ratios. The adjusted experimental results indicate that increasing Reynolds number from 5.0 to 20.0 x 10 to the 6th power decreased the dynamic pressure by 4.0 to 6.5 percent at M = 0.5 and 0.8.

Cole, S. R.↗

Performance tests of a cryogenic hybrid magnetic bearing for turbopumps

Experiments were performed on a Hybrid Magnetic Bearing designed for cryogenic applications such as turbopumps. This bearing is considerably smaller and lighter than conventional magnetic bearings and is more efficient because it uses a permanent magnet to provide a bias flux. The tests were performed in a test rig that used liquid nitrogen to simulate cryogenic turbopump temperatures. The bearing was tested at room temperature and at liquid nitrogen temperature (-320 F). The maximum speed for the test rig was 14000 rpm. For a magnetic bearing stiffness of 20000 lb/in, the flexible rotor had two critical speeds. A static (nonrotating) bearing stiffness of 85000 lb/in was achieved. Magnetic bearing stiffness, permanent magnet stiffness, actuator gain, and actuator force interaction between two axes were evaluated, and controller/power amplifier characteristics were determined. The tests revealed that it is feasible to use this bearing in the cryogenic environment and to control the rotor dynamics of flexible rotors when passing through bending critical speeds. The tests also revealed that more effort should be placed on enhancing the controller to achieve higher bearing stiffness and on developing displacement sensors that reduce drift caused by temperature and reduce sensor electrical noise.

Dirusso, Eliseo↗

Liquid Acquisition Device Hydrogen Outflow Testing on the Cryogenic Propellant Storage and Transfer Engineering Design Unit

As part of the NASA Cryogenic Propellant Storage and Transfer (CPST) Engineering Design Unit (EDU) testing with liquid hydrogen, screen-channel liquid acquisition devices (LADs) were tested during liquid hydrogen outflow from the EDU tank. A stainless steel screen mesh (325x2300 Dutch T will weave) was welded to a rectangular cross-section channel to form the basic LAD channel. Three LAD channels were tested, each having unique variations in the basic design. The LADs fed a common outflow sump at the aft end of the 151 cu. ft. volume aluminum tank, and included a curved section along the aft end and a straight section along the barrel section of the tank. Wet-dry sensors were mounted inside the LAD channels to detect when vapor was ingested into the LADs during outflow. The use of warm helium pressurant during liquid hydrogen outflow, supplied through a diffuser at the top of the tank, always led to early breakdown of the liquid column. When the tank was pressurized through an aft diffuser, resulting in cold helium in the ullage, LAD column hold-times as long as 60 minutes were achieved, which was the longest duration tested. The highest liquid column height at breakdown was 58 cm, which is 23 less than the isothermal bubble-point model value of 75 cm. This paper discusses details of the design, construction, operation and analysis of LAD test data from the CPST EDU liquid hydrogen test.

Liquid hydrogen↗