Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Infrared intrusion detection system (IRIDS)

A system and method for intrusion detection includes an imager directed towards an object in an interior space. The imager is in data communication with a computer. The computer is arranged to process digital three-dimensional image data received from the imager and programmed to execute a change detection algorithm in response to the processed three-dimensional data to determine movement of the object. The computer generates an alarm output in response to detecting movement of the object above a predetermined threshold. The method includes providing an imager directed towards an object in an interior space; receiving Time of Flight signals by the imager; processing digital three-dimensional image data received from the imager; and executing a change detection algorithm in response to the processed three-dimensional data to determine movement of the object.

Russell, John L.↗

Preliminary design of an Earth-based debris detection system using current technology and existing installations

A simple instrument based on present-epoch technology for optical detection of orbital debris is described. The limits of detectability at various altitudes and under different operating conditions for this system are assessed. The kinds of information which can be deduced from this data are examined. Optimal systems for debris detection are discussed. Alternatives and possible improvements from new technologies are also considered.

Morgan, T. H.↗

All-to-all sequenced fault detection system

An apparatus, program product and method enable nodal fault detection by sequencing communications between all system nodes. A master node may coordinate communications between two slave nodes before sequencing to and initiating communications between a new pair of slave nodes. The communications may be analyzed to determine the nodal fault.

Archer, Charles Jens↗

Nonlocality in many-body quantum systems detected with two-body correlators

Contemporary understanding of correlations in quantum many-body systems and in quantum phase transitions is based to a large extent on the recent intensive studies of entanglement in many-body systems. In contrast, much less is known about the role of quantum nonlocality in these systems, mostly because the available multipartite Bell inequalities involve high-order correlations among many particles, which are hard to access theoretically, and even harder experimentally. Standard, “theorist- and experimentalist-friendly” many-body observables involve correlations among only few (one, two, rarely three...) particles. Typically, there is no multipartite Bell inequality for this scenario based on such low-order correlations. Recently, however, we have succeeded in constructing multipartite Bell inequalities that involve two- and one-body correlations only, and showed how they revealed the nonlocality in many-body systems relevant for nuclear and atomic physics [Tura et al., Science 344 (2014) 1256]. With the present contribution we continue our work on this problem. On the one hand, we present a detailed derivation of the above Bell inequalities, pertaining to permutation symmetry among the involved parties. On the other hand, we present a couple of new results concerning such Bell inequalities. First, we characterize their tightness. We then discuss maximal quantum violations of these inequalities in the general case, and their scaling with the number of parties. Moreover, we provide new classes of two-body Bell inequalities which reveal nonlocality of the Dicke states—ground states of physically relevant and experimentally realizable Hamiltonians. Finally, we shortly discuss various scenarios for nonlocality detection in mesoscopic systems of trapped ions or atoms, and by atoms trapped in the vicinity of designed nanostructures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Randomness fault detection system

A method and apparatus are provided for detecting a fault on a power line carrying a line parameter such as a load current. The apparatus monitors and analyzes the load current to obtain an energy value. The energy value is compared to a threshold value stored in a buffer. If the energy value is greater than the threshold value a counter is incremented. If the energy value is greater than a high value threshold or less than a low value threshold then a second counter is incremented. If the difference between two subsequent energy values is greater than a constant then a third counter is incremented. A fault signal is issued if the counter is greater than a counter limit value and either the second counter is greater than a second limit value or the third counter is greater than a third limit value.

Russell, B. Don↗

All row, planar fault detection system

An apparatus, program product and method for detecting nodal faults may simultaneously cause designated nodes of a cell to communicate with all nodes adjacent to each of the designated nodes. Furthermore, all nodes along the axes of the designated nodes are made to communicate with their adjacent nodes, and the communications are analyzed to determine if a node or connection is faulty.

42 ENGINEERING↗

Next Generation NASA Hazard Detection System Development

The SPLICE project is continuing NASA’s efforts to develop precision landing GN&C technologies for future lander missions. One of those technologies is the next generation Hazard Detection (HD) System, which consists of a new HD Lidar and HD Algorithms. The HD System is a modular system that will be adapted to meet specific mission needs in the future. This paper presents the design approach, the nominal concept of operations for which the first prototype is being designed, and the expected performance of the system.

Restrepo, Carolina I.↗

Laser Schlieren System Detects Sounds Of Leaks

Hostile environments monitored safely and noninvasively. Modified laser schlieren system acts as microphone to detect sounds of leaks remotely. Sensitive to acoustical frequencies above audible range and especially suited for monitoring leaks of high-pressure steam from boilers or chemical vapors from processing equipment. Does not require placement of delicate equipment in harsh environment monitored, and no contact needed with boiler or other unit being monitored. Detects sound waves via variation of index of refraction of air at acoustical frequencies. Used to monitor sound frequencies beyond range of human hearing.

Shakkottai, Parthasarathy P.↗

Federated Machine Learning-Based Anomaly Detection System for Synchrophasor Network Using Heterogeneous Data Sets: Preprint

Synchrophasor technology is widely deployed in the energy management system to monitor the grid health at micro level and perform necessary corrective actions in real time; however, integrated phasor devices and data aggregators are exposed to several cybersecurity threats. This paper proposes a federated ML(FML)-based ADS to detect several data integrity attacks in the synchrophasor network. The proposed approach integrates the horizontal FML technique and consists of substation-based local models and a control center-based global model. The proposed methodology includes training local models using heterogeneous data sets that include network and grid information and updating the global model through multiple iterations by sharing model gradients. Finally, the trained global model is applied to identify cyberattacks, normal operation, and physical events. To validate the proof of concept, we used synthetic data sets generated by Mississippi State University and Oak Ridge National Laboratory for training and testing the classification models using the National Renewable Energy Laboratory's high performance computing resources. Our experimental results, computed through several performance measures, reveal that the proposed approach shows consistent performance during the binary, three-class, and multiclass classifications while ensuring privacy of synchrophasor data.

anomaly detection system↗

Feasibility of an on-line fission-gas-leak detection system

Calculations were made to determine if a cladding failure could be detected in a 100-kW zirconium hydride reactor primary system by monitoring the highly radioactive NaK coolant for the presence of I-131. The system is to be completely sealed. A leak of 0.01 percent from a single fuel pin was postulated. The 0.364-MeV gamma of I-131 could be monitored on an almost continuous basis, while its presence could be varified by using a longer counting time for the 0.638-MeV gamma. A lithium-drifted germanium detector would eliminate radioactive corrosion product interference that could occur with a sodium iodide scintillation detector.

Lustig, P. H.↗

Design of infrasound-detection system via adaptive LMSTDE algorithm

A proposed solution to an aviation safety problem is based on passive detection of turbulent weather phenomena through their infrasonic emission. This thesis describes a system design that is adequate for detection and bearing evaluation of infrasounds. An array of four sensors, with the appropriate hardware, is used for the detection part. Bearing evaluation is based on estimates of time delays between sensor outputs. The generalized cross correlation (GCC), as the conventional time-delay estimation (TDE) method, is first reviewed. An adaptive TDE approach, using the least mean square (LMS) algorithm, is then discussed. A comparison between the two techniques is made and the advantages of the adaptive approach are listed. The behavior of the GCC, as a Roth processor, is examined for the anticipated signals. It is shown that the Roth processor has the desired effect of sharpening the peak of the correlation function. It is also shown that the LMSTDE technique is an equivalent implementation of the Roth processor in the time domain. A LMSTDE lead-lag model, with a variable stability coefficient and a convergence criterion, is designed.

Khalaf, C. S.↗

Data fusion for a vision-aided radiological detection system: Calibration algorithm performance

In order to improve the ability to detect, locate, track and identify nuclear/radiological threats, the University of Florida nuclear detection community has teamed up with the 3D vision community to collaborate on a low cost data fusion system. The key is to develop an algorithm to fuse the data from multiple radiological and 3D vision sensors as one system. The system under development at the University of Florida is being assessed with various types of radiological detectors and widely available visual sensors. A series of experiments were devised utilizing two EJ-309 liquid organic scintillation detectors (one primary and one secondary), a Microsoft Kinect for Windows v2 sensor and a Velodyne HDL-32E High Definition LiDAR Sensor which is a highly sensitive vision sensor primarily used to generate data for self-driving cars. Each experiment consisted of 27 static measurements of a source arranged in a cube with three different distances in each dimension. The source used was Cf-252. The calibration algorithm developed is utilized to calibrate the relative 3D-location of the two different types of sensors without need to measure it by hand; thus, preventing operator manipulation and human errors. The algorithm can also account for the facility dependent deviation from ideal data fusion correlation. Use of the vision sensor to determine the location of a sensor would also limit the possible locations and it does not allow for room dependence (facility dependent deviation) to generate a detector pseudo-location to be used for data analysis later. Using manually measured source location data, our algorithm-predicted the offset detector location within an average of 20 cm calibration-difference to its actual location. Calibration-difference is the Euclidean distance from the algorithm predicted detector location to the measured detector location. The Kinect vision sensor data produced an average calibration-difference of 35 cm and the HDL-32E produced an average calibration-difference of 22 cm. Using NaI and He-3 detectors in place of the EJ-309, the calibration-difference was 52 cm for NaI and 75 cm for He-3. In conclusion, the algorithm is not detector dependent; however, from these results it was determined that detector dependent adjustments are required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High efficiency method of fast neutron detection by oxide scintillators for detection systems of fissionable radioactive substances

Comparative measurements and analysis of detection efficiency (DE) of fast neutrons from {sup 239}Pu-Be source have been carried out in a broad energy range En {approx} 0.1 ./. 10 MeV using oxide scintillators BGO, GSO, CWO, ZnWO, ZnSe(Te, O), as well as LiI(Eu). DE of fast neutrons by heavy oxide scintillators was found to be very high ({approx} 40-50 %). The neutron inelastic scattering reaction (n, n'y) is considered as the most probable interaction mechanism of neutrons with nuclei of heavy oxide scintillators. It is concluded that heavy oxide scintillators, which are at the same time efficient gamma-detectors, allow creation of a highly efficient gamma-neutron detector ensuring high detection efficiency of fissionable radioactive substances. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗