High-Resolution Electron Energy-Loss Spectroscopy (HREELS) Using a Monochromated TEM/STEM

A 200 keV FEI TF20 XT monochromated (scanning) transmission electron microscope funded by NASA's SRLIDAP program is undergoing installation at Lawrence Livermore National Laboratory. Instrument specifications in STEM mode are Cs =1.0 mm, Cc =1.2 mm, image resolution =0.18 nm, and in TEM mode Cs =1.3 mm, Cc =1.3 mm, information limit =0.14 nm. Key features of the instrument are a voltage-stabilized high tension (HT) supply, a monochromator, a high-resolution electron energy-loss spectrometer/energy filter, a high-resolution annular darkfield detector, and a solid-state x-ray energy-dispersive spectrometer. The high-tension tank contains additional sections for 60Hz and high frequency filtering, resulting in an operating voltage of 200 kV plus or minus 0.005V, a greater than 10-fold improvement over earlier systems. The monochromator is a single Wien filter design. The energy filter is a Gatan model 866 Tridiem-ERS high resolution GIF spec d for less than or equal to 0.15 eV energy resolution with 29 pA of current in a 2 nm diameter probe. 0.13 eV has already been achieved during early installation. The x-ray detector (EDAX/Genesis 4000) has a take-off angle of 20 degrees, an active area of 30 square millimeters, and a solid angle of 0.3 steradians. The higher solid angle is possible because the objective pole-piece allows the detector to be positioned as close as 9.47 mm from the specimen. The voltage-stabilized HT supply, monochromator and GIF enable high-resolution electron energy-loss spectroscopy (HREELS) with energy resolution comparable to synchrotron XANES, but with approximately 100X better spatial resolution. The region between 0 and 100 eV is called the low-loss or valence electron energy-loss spectroscopy (VEELS) region where features due to collective plasma oscillations and single electron transitions of valence electrons are observed. Most of the low-loss VEELS features we are detecting are being observed for the first time in IDPs. A major focus of our research is to understand the origin and significance of these features and how they might be exploited to gain insight about IDPs and other meteoritic materials.

Sai, Z. R.↗

Thermal detectors as X-ray spectrometers

Sensitive thermal detectors should be useful for measuring very small energy pulses, such as those produced by the absorption of X-ray photons. The measurement uncertainty can be very small, making the technique promising for high resolution nondispersive X-ray spectroscopy. The limits to the energy resolution of such thermal detectors are derived and used to find the resolution to be expected for a detector suitable for X-ray spectroscopy in the 100 eV to 10,000 eV range. If there is no noise in the thermalization of the X-ray, resolution better than 1 eV full width at half maximum is possible for detectors operating at 0.1 K. Energy loss in the conversion of the photon energy to heat is a potential problem. The loss mechanisms may include emission of photons or electrons, or the trapping of energy in long lived metastable states. Fluctuations in the phonon spectrum could also limit the resolution if phonon relaxation times are very long. Conceptual solutions are given for each of these possible problems.

Moseley, S. H.↗

Thermal detectors as X-ray spectrometers

Sensitive thermal detectors should be useful for measuring very small energy pulses, such as those produced by the absorption of X-ray photons. The measurement uncertainty can be very small, making the technique promising for high resolution nondispersive X-ray spectroscopy. The limits to the energy resolution of such thermal detectors are derived and used to find the resolution to be expected for a detector suitable for X-ray spectroscopy in the 100 eV to 10,000 eV range. If there is no noise in the thermalization of the X-ray, resolution better than 1 eV full width at half maximum is possible for detectors operating at 0.1 K. Energy loss in the conversion of the photon energy to heat is a potential problem. The loss mechanisms may include emission of photons or electrons, or the trapping of energy in long lived metastable states. Fluctuations in the phonon spectrum could also limit the resolution if phonon relaxation times are very long. Conceptual solutions are given for each of these possible problems.

Moseley, S. H.↗

Calibration and performance of the energetic X-ray imaging telescope experiment

The final integration and testing of the Energetic X-ray Imaging Telescope Experiment (EXITE) are described. The detector and telescope as finally assembled are described, and problems as well as solutions are detailed. The preflight calibration of the position-sensitive NaI detector revealed unanticipated effects in the energy spectra. In particular, an effect due to surface roughness (lack of firm optical polishing) on the crystal was found and calibrated. The radial variation of gain and resolution in the detector was also measured, and so-called flat fielding methods have been derived to analyze the data. The integration of the EXITE detector and gondola systems is described. Several novel features were developed for the EXITE gondola, most notably a shock absorber system. The performance of the detector and gondola systems was evaluated on a first balloon flight from Australia (May 1988) and a second flight from Ft. Sumner, New Mexico (October 1988).

Braga, Joao↗

Test and characterization of finely segmented pixel CZT detectors for future hard x-ray missions

The NuSTAR (Nuclear Spectroscopic Telescope Array) mission was launched in 2012, and it has successfully deployed the first orbiting telescopes to focus high energy X-ray (3 - 79 keV) light, providing a wealth of new information on high-energy X-rays sources. Follow-up missions, such as the proposed HEX-P, BEST, and FORCE, could perform a deeper black hole census providing a more refined measurement of black hole spins, allowing for greater knowledge about supermassive black holes. Here, these missions are motivated by the recent breakthroughs in the hard X-ray mirror technologies, where mirrors, either made of monolithic silicon segments, or made directly or via replication of shells, demonstrate the feasibility of making hard X-ray mirrors with angular resolutions of 5-10 arc-seconds Half Power Diameter (HPD) compared to the NuSTAR’s 1 arc-minute HPD. Such a high angular resolution requires matched detectors with higher degree of segmentation to fully benefit from the achievable improved spatial resolution. In the above framework, the HEXID ASIC, a novel pixelated front-end suitable for reading out a finely segmented CZT sensor with 150 μm pixel pitch in a hexagonal arrangement has been developed. This readout pixelated chip is capable of processing photon-generated charge packets over a large dynamic range (from 2 keV up to 180 keV), while keeping a low input noise (ENC <20 e - ). In this work, the initial characterization of the ASIC prototype will be presented.

47 OTHER INSTRUMENTATION↗

Radiation effects induced by the energetic protons in 8x8x32 mm3 CdZnTe detectors

We report CdZnTe (CZT) detectors have been used in the past and are being actively considered for future gamma-ray space telescopes. One of the challenges of operating CZT detectors in low Earth orbit is radiation damage caused by energetic protons. Previous studies concluded that fluences of 10 8 -10 9 p/cm 2 are sufficient to cause shifting of peak positions and degradations of energy resolution. Degradation of detectors after proton irradiation has been extensively investigated to determine their radiation resistance limits and performance recovering procedures for their applications in space and nuclear nonproliferation. Here we present the study of radiation effects induced by 100 MeV protons in 3-cm long CdZnTe detectors that we recently proposed for the gamma-ray telescope GECCO. The goal this study is to evaluate the feasibility of using such long CZT detectors in future space missions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray spectroscopy and imagery of supernova remnants with the Einstein Observatory

The two complementary spectroscopic instruments of the Einsten Observatory make possible X-ray spectroscopy of SNRs with considerably increased sensitivity and spectral resolution. The Solid State Spectrometer is a cryogenically cooled detector with 160 eV resolution, which suffices not only for the separation of lines due to different elements, but also the resolution of H-like, He-like and neutral lines from the same element for Si and above. The Focal Plane Crystal Spectrometer uses Bragg crystals to achieve excellent spectral resolution, but at the expense of sensitivity. Both instruments operate over most of the 0.2-4 keV energy band of the Einstein telescope, and are able to detect most of the important X-ray lines except the K lines of Fe and Ni.

Winkler, P. F.↗

Cosmic Ray Energy Determination by the Reduced-Opening Angle Method

Accurate measurement of the primary galactic cosmic ray species energy dependence in the regime beyond approx. 500 GeV/a is difficult due to the low flux and the limitations of energy measurement techniques. However, such observations are essential to resolve several questions of current interest such as: Is the enrichment of heavy species (Z greater that or equal to 6) cosmic rays first reported at higher energies by the proton satellite' and then later at lower energies real? The results from a previous deployment of the reduced opening angle technique are inconclusive but the authors do point to limitations in the previous techniques. Another intriguing puzzle is the energy dependence of silicon cosmic rays. Two independent experiments using different experimental techniques indicate that silicon is under-abundant. At present the observation is limited by statistics; it could still be a three sigma fluctuation. However, if confirmed the current models of acceleration and propagation which are species independent are seriously inadequate. To progress further the species and energy dependence must be accurately measured in a manner that is free from systematic uncertainty. In this report we show that the reduced opening angle method offers a simple and relatively inexpensive method to answer these questions. First we present the physics of the reduced opening angle and indicate the expected energy and charge resolution. The proposed detector design is then presented followed by the expected performance. Where ever possible simple phenomenological expressions that allow 'back of the envelope' estimates are given. More details are presented in the appendices. The limit of the energy resolution and the expected event rates for iron cosmic rays are calculated. Salient points are summarized in the conclusions.

Smith, Arthur E.↗

X-ray and γ-ray beam interstellar communication and implications for SETI

The possibility of detecting artificial signals transmitted by alien civilizations via collimated X-ray or gamma-ray beams is investigated. The prospect of using such beams for human communication within the solar system and beyond is also discussed. Detector responses were simulated for input signals and analyzed using relative entropy. For simplicity, all signals were assumed to use on-off keying (OOK) modulation. “Real” signals were generated by taking digital files and sequentially feeding their raw binary data to the detector simulator, the resulting normalized information content of the detector signals was plotted and compared to random noise signals. Since jpeg files contain compressed information, these served as a proxy for artificial alien signals. This showed that there is a clear difference in measured information content between natural and artificial signals, even with relatively poor time resolution in the detector causing the signals to be smeared (dead-time/rise-time intervals many times longer than the duration between signal pulses). It was found that so long as the signal lasts for at least several rise-time/dead-time intervals, the distinction between random and artificial signals is obvious. A space-telescope with high time resolution for searching for such signals is briefly described and its basic requirements are outlined.

43 PARTICLE ACCELERATORS↗

Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS

We consider the potential for a 10 kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model (BSM). Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several BSM scenarios such as neutrino nonstandard interactions and accelerator-produced dark matter. This detector’s performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of Cs and I nuclei and detection of neutrinos from a core-collapse supernova. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis and Evaluation of the LANDSAT-4 MSS and TM Sensors and Ground Data Processing Systems: Early Results

The MSS and TM sensor performances were evaluated by studying both the sensors and the characteristics of the data. Information content analysis, image statistics, band-to-band registration, the presence of failed or failing detectors, and sensor resolution are discussed. The TM data were explored from the point of view of adequacy of the ground processing and improvements that could be made to compensate for sensor problems and deficiencies. Radiometric correction processing, compensation for a failed detector, and geometric correction processing are also considered.

Bernstein, R.↗

High resolution decoding of Multi-Anode Microchannel Array detectors

The Multi-Anode Microchannel Array (MAMA) is a photon counting detector which utilizes a photocathode for photon to electron conversion, a microchannel plate (MCP) for signal amplification and a proximity focused anode array for position sensitivity. The detector electronics decode the position of an event through coincidence discrimination. The decoding algorithm which associates a given event with the appropriate pixel is determined by the geometry of the array. A new algorithm incorporated into a CMOS Application Specific Integrated Circuit (ASIC) decoder which improves the pixel spatial resolution is described. The new algorithm does not degrade the detector throughput and does not require any modifications to the detector tube. The standard MAMA detector has a pixel size of 25 x 25 square microns, but with the new decoder circuit the pixel size is reduced to 12.5 x 12.5 square microns. We have built the first set of decode electronics utilizing the new ASIC chips and report here on the first imaging tests of this system.

Kasle, David B.↗

3D-Reconstruction of Tau Neutrinos in LArTPC Detectors

The Deep Underground Neutrino Experiment (DUNE) is a next-generation neutrino experiment currently under construction. DUNE will consist of two high-resolution neutrino interaction imaging detectors exposed to the world’s most intense neutrino beam, with the Near Detector at Fermilab and the Far Detector 1,300 km away in the Sanford Underground Research Facility in South Dakota, US. The high statistics and excellent resolution capabilities of DUNE's $^{40}$Ar detector will allow us to make precision studies of oscillation parameters capable of searching for CP violation in the lepton sector, testing interaction models, and studying phenomena that have until now, seemed too complex to measure, like $\nu_\tau$ detection and therefore, providing the completion of the 3-flavor neutrino paradigm. Knowledge of the $\nu_\tau$ detection can impact a broad spectrum of open questions. These include searching for non-standard neutrino interactions, constraining the unitarity of the PMNS matrix, searching for sterile neutrinos, and studying neutrino interactions. In the case of LArTPC data, the detector hits can be considered nodes in a graph, and the edges represent the spatial and temporal relationships between them. By using graph neural networks, it is possible to exploit these relationships and improve the accuracy of particle identification and reconstruction. During my presentation and specifically for tau neutrino reconstruction, I will show the effectiveness and reliability of our in-house developed graph neural network (GNN), NuGraph. This GNN classifies detector hits based on the particle type responsible for their production, assuring that the system accurately identifies and categorizes information based on its unique characteristics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NASA's Advancements in Space-Based Spectrometry Lead to Improvements in Weather Prediction and Understanding of Climate Processes

AIRS is a precision state of the art High Spectral Resolution Multi-detector IR grating array spectrometer that was launched into a polar orbit on EOS Aqua in 2002. AIRS measures most of the infra-red spectrum with very low noise from 650/cm to 2660/cm with a resolving power of 2400 at a spatial resolution of 13 km. The objectives of AIRS were to perform accurate determination of atmospheric temperature and moisture profiles in up to 90% partial cloud cover conditions for the purpose of improving numerical weather prediction and understanding climate processes. AIRS data has also been used to determine accurate trace gas profiles. A brief overview of the retrieval methodology used to analyze AIRS observations under partial cloud cover will be presented and sample results will be shown from the weather and climate perspectives.

Susskind, Joel↗

Development Status of the KIPM Detector Consortium

A kinetic inductance phonon-mediated detector is a calorimeter that uses kinetic inductance detectors (KIDs) to read out phonon signals from the device substrate. We have established a consortium comprising university and national lab groups dedicated to advancing the state of the art in these detectors, with the ultimate goal of designing a detector with sub-eV threshold on energy deposited in the substrate, enabling searches for both light dark matter and low-energy neutrino interactions. This consortium brings together experts in KID design, phonon and quasi-particle dynamics, and noise modeling, along with specialized fabrication facilities, test platforms, and unique calibration capabilities. Recently, our consortium has demonstrated a resolution on energy absorbed by the sensor of 2.1 eV, the current record for phonon-sensitive KIDs. However, due to ∼ 1% phonon collection efficiency, the overall detector resolution was limited to 320 eV. Finally, the current focus of the consortium is modeling and improving the phonon collection efficiency and implementing low-T c superconductors, both of which serve to improve the overall energy resolution and threshold of the detectors.

Temples, Dylan J. [Fermi National Accelerator Labo↗

Beamline Spectroscopy of Integrated Circuits With Hard X-Ray Transition Edge Sensors at the Advanced Photon Source

At Argonne National Laboratory, we are developing hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to semiconductor-based energy-dispersive detectors, but with better collection efficiency than wavelength-dispersive instruments, will enable greatly improved X-ray emission and absorption spectroscopic measurements. Additionally, a prototype instrument with 24 microwave-frequency multiplexed pixels is now in testing at the Advanced Photon Source (APS) 1-BM beamline. Initial measurements show an energy resolution ten times better (150 eV compared to < 15 eV) than the silicon-drift detectors currently available to APS beamline users, and in particular demonstrate the ability to resolve closely-spaced emission lines in samples containing multiple transition metal elements, such as integrated circuits. Comparing fluorescence spectra of integrated circuits measured with our TESs at the beamline to those measured with silicon detectors, we find emission lines and elements largely hidden (e.g. Hf alongside Cu) from a semiconductor-based detector but well resolved by a TES. This directly shows the strengths of TES-based instruments in fluorescence mapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and performance of the Fermilab Constant Fraction Discriminator ASIC

Here, we present the design and performance characterization results of the novel Fermilab Constant Fraction Discriminator ASIC (FCFD) developed to readout low gain avalanche detector (LGAD) signals by directly using a constant fraction discriminator (CFD) to measure signal arrival time. Silicon detectors with time resolutions less than 30ps will play a critical role in future collider experiments, and LGADs have been demonstrated to provide the required time resolution and radiation tolerance for many such applications. The FCFD has a specially designed discriminator that is robust against amplitude variations of the signal from the LGAD that normally requires an additional correction step when using a traditional leading edge discriminator. The application of the CFD directly in the ASIC promises to be more reliable and reduces the complication of evolving time-walk corrections throughout the operational lifetime of the detector system. We will present a summary of the measured performance of the FCFD for input signals generated by internal charge injection, LGAD signals from an infrared laser, and LGAD signals from minimum-ionizing particles. The mean time response for LGAD signals with charge ranging between 5 and 26 fC has been measured to vary no more than 10ps, orders of magnitude more stable than an uncorrected leading edge discriminator based measurement, and effectively removes the need for any additional time-walk correction. The measured contribution to the time resolution from the FCFD ASIC is found to be 10ps for signals with charge above 20fC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗