Search NASA⌕ Search

SEARCH · Search NASA

Results for “difference frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A TECHNIQUE FOR FOREGROUND SUBTRACTION IN REDSHIFTED 21 cm OBSERVATIONS

One of the main challenges for future 21 cm observations is to remove foregrounds which are several orders of magnitude more intense than the H I signal. We propose a new technique for removing foregrounds of the redshifted 21 cm observations. We consider multi-frequency interferometer observations. We assume that the 21 cm signals in different frequency channels are uncorrelated and the foreground signals change slowly as a function of frequency. When we add the visibilities of all channels, the foreground signals increase roughly by a factor of {approx}N because they are highly correlated. However, the 21 cm signals increase by a factor of {approx}{radical}N because the signals in different channels contribute randomly. This enables us to obtain an accurate shape of the foreground angular power spectrum. Then, we obtain the 21 cm power spectrum by subtracting the foreground power spectrum obtained this way. We describe how to obtain the average power spectrum of the 21 cm signal.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental implementation of phase locking in a nonlinear interferometer

Based upon two cascade four-wave mixing processes in two identical hot rubidium vapor cells, a nonlinear interferometer has been experimentally realized [Jing et al., Appl. Phys. Lett. 99, 011110 (2011); Hudelist et al., Nat. Commun. 5, 3049 (2014)]. It has a higher degree of phase sensitivity than a traditional linear interferometer and has many potential applications in quantum metrology. Phase locking of the nonlinear interferometer is needed before it can find its way into applications. In this letter, we investigate the experimental implementation of phase locking of the relative phase between the three beams at different frequencies involved in such a nonlinear interferometer. We have utilized two different methods, namely, beat note locking and coherent modulation locking. We find that coherent modulation locking can achieve much better phase stability than beat note locking in our system. Our results pave the way for real applications of a nonlinear interferometer in precision measurement and quantum manipulation, for example, phase control in phase-sensitive N-wave mixing process, N-port nonlinear interferometer and quantum-enhanced real-time phase tracking.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

90-GHz flux-density measurements of variable radio sources

Results are presented for measurements of the flux densities of 10 variable extragalactic sources at 85.2 or 90 GHz, which were made over a period of almost seven years with the NRAO 36-ft millimeter-wave antenna. The primary flux-density calibration standards used include Jupiter, Saturn, Mars, and the small-diameter Galactic source DR 21. Measured flux densities are given as a function of time (in years) for the sources 3C 84, NRAO 150, 3C 120, OJ 287, 4C 39.25, 3C 273, 3C 279, 3C 345, BL Lac, and 3C 454.3. No statistically meaningful flux-density changes during an observing interval (1 to 3 days) are detected for any source, and a high degree of correlation between flux-density variations at 85.2 or 90 GHz and those observed at lower frequencies is found in all 10 sources. Some variations observed at different frequencies in several individual sources are briefly discussed.

Hobbs, R. W.↗

Surface scattering effects at different spectral regions

The development of theoretical models of rough surface scattering in different frequency regions is reviewed. The applications of the models to four different types of rough surface scattering are presented. The four categories of surface roughness effects are: (1) where the angular distribution of first-order average incoherent scattered power is proportional to the roughness spectrum of the surface; (2) where the horizontal roughness scale is less than the incident wavelength; (3) where both the horizontal and vertical roughness scales are large compared to the incident wavelength; and (4) scattering in the specular direction is dominated by large-scale roughness, and scattering in the opposite direction is dominated by small-scale roughness. Acoustic, optical and microwave scattering measurements from rough surfaces are presented which illustrate the four types of scattering behavior.

Fung, A. K.↗

100-GHz Phase Switch/Mixer Containing a Slot-Line Transition

A circuit that can function as a phase switch, frequency mixer, or frequency multiplier operates over a broad frequency range in the vicinity of 100 GHz. Among the most notable features of this circuit is a grounded uniplanar transition (in effect, a balun) between a slot line and one of two coplanar waveguides (CPWs). The design of this circuit is well suited to integration of the circuit into a microwave monolithic integrated circuit (MMIC) package. One CPW is located at the input end and one at the output end of the top side of a substrate on which the circuit is fabricated (see Figure 1). The input CPW feeds the input signal to antiparallel flip-chip Schottky diodes connected to the edges of the slot line. Phase switching is effected by the combination of (1) the abrupt transition from the input CPW to the slot line and (2) CPW ground tuning effected by switching of the bias on the diodes. Grounding of the slot metal to the bottom metal gives rise to a frequency cutoff in the slot. This cutoff is valuable for separating different frequency components when the circuit is used as a mixer or multiplier. Proceeding along the slot line toward the output end, one encounters the aforementioned transition, which couples the slot line to the output CPW. Impedance tuning of the transition is accomplished by use of a high-impedance section immediately before the transition.

Gaier, Todd↗

Carbon Nanotubes as Resonators for RF Spectrum Analyzers

Electromechanical resonators of a proposed type would comprise single carbon nanotubes suspended between electrodes (see Figure 1). Depending on the nanotube length, diameter, and tension, these devices will resonate at frequencies in a range from megahertz through gigahertz. Like the carbon-nanotube resonators described in the preceding article, these devices will exhibit high quality factors (Q values), will be compatible with integration with electronic circuits, and, unlike similar devices made from silicone and silicone carbide, will have tunable resonant frequencies as high as several GHz. An efficient electromechanical transduction method for the carbon nanotube resonators is provided by the previously observed variation of carbon nanotube length with charge injection. It was found that injection of electrons or holes, respectively, lengthens or shortens carbon nanotubes, by amounts of the order of a percent at bias levels of a few volts. The charge-dependent length change also enables a simple and direct means of tuning the resonant frequency by varying the DC bias and hence the tension along the tube, much like tuning a guitar string. In its basic form, the invention is a tunable high-Q resonator based on a suspended carbon nanotube bridge with attached electrodes (see Figure 1). An applied DC bias controls the tension and thus the frequency of resonance. If one were to superimpose a radio-frequency (RF) bias on the DC bias, then the resulting rapid variation in tension or length would set the tube into vibration. If, on the other hand, the carbon nanotube were to be set into vibration by interaction between an incident RF electric field and electric charges in the nanotube, then the vibration would give rise to an RF signal output that is proportional to the RF amplitude at the resonance frequency. Because the transduction mechanism is extremely sensitive and the active volume is only a few nanometers in diameter, this device is not well suited for use as a microwave power device. Instead, this carbon nanotube mechanical resonator would be useful primarily as part of a highly precise, sensitive, frequency-selective detector. An array of such devices featuring nanotubes of different lengths (and thus different frequencies) could be made to operate as a highspeed spectrum analyzer (see Figure 2)

Hunt, Brian↗

The study of microstrip antenna arrays and related problems

The work on rectangular microstrip antennas for dual frequency operation is reported on. The principle of this approach is based on the excitation of a patch for two or more different modes which correspond to different frequencies. However, for a given geometry, the modal frequencies have a fixed relationship; therefore, the usefulness of such a design is greatly limited. In this study three different methods have been contrived to control the frequency ratio over a wide range. First, as found prevously, if shorting pins are inserted at certain locations in the patch, the low frequency can be raised substantially. Second, if slots are cut in the patch, the high frequency can be lowered considerably. By using both techniques, the two frequency ratio can be varied approximately from 3 to 1.3. After that, the addition of more pins or slots becomes ineffective.

Lo, R. Q.↗

The Effect of Dose Rate on the Frequency of Specific-Locus Mutations Induced in Mouse Spermatogonia is Restricted to Larger Lesions; a Retrospective Analysis of Historical Data

A series of 19 large-scale germ-cell mutagenesis experiments conducted several decades ago led to the conclusion that low-LET radiation delivered to mouse spermatogonia at dose rates of 0.8 R/min and below induced only about one-third as many specific-locus mutations as did single, acute exposures at 24 R/min and above. A two-hit origin of the mutations was deemed unlikely in view of the then prevailing evidence for the small size of genetic lesions in spermatogonia. Instead, the dose-rate effect was hypothesized to be the result of a repair system that exists in spermatogonia, but not in more mature male reproductive cells. More recent genetic and molecular studies on the marker genes have identified the phenotypes associated with specific states of the mutant chromosomes, and it is now possible retrospectively to classify individual past mutations as "large lesions" or "other lesions". The mutation-frequency difference between high and low dose rates is restricted to the large lesion mutations, for which the dose-curve slopes differ by a factor exceeding 3.4. For other lesion mutations, there is essentially no difference between the slopes for protracted and acute irradiations; induced other lesions frequencies per unit dose remain similar for dose rates ranging over more than 7 orders of magnitude. For large lesions, these values rise sharply at dose rates >0.8 R/min, though they remain similar within the whole range of protracted doses, failing to provide evidence for a threshold dose rate. The downward bend at high doses that had been noted for X-ray-induced specific-locus mutations as a whole and ascribed to a positive correlation between spermatogonial death and mutation load is now found to be restricted to large lesion mutations. There is a marked difference between the mutation spectra (distributions among the seven loci) for large lesions and other lesions. Within each class, however, the spectra are similar for acute and protracted irradiation.

59 BASIC BIOLOGICAL SCIENCES↗

Control of multitransparency windows via dark-state phase manipulation

We identify a process in which we can control the behavior of an atomic medium to switch between transparent and enhanced-absorption at multiple frequencies. The process relies on the quantum interference between multiple dark states, which can be constructive or destructive at different frequencies and can be altered dramatically by changing the phase difference between the two circularly polarized components of a single coherent field. This phase-controlled switching behavior is obtainable without altering the powers or frequency detunings of the beams. We demonstrate the process experimentally by using two coherent fields and atomic rubidium vapor. Such selective switching between multiple frequency channels could also have applications in optical communication and quantum information processing.

74 ATOMIC AND MOLECULAR PHYSICS↗

Comparison of experimental rotor damping data-reduction techniques

The ability of existing data reduction techniques to determine frequency and damping from transient time-history records was evaluated. Analog data records representative of small-scale helicopter aeroelastic stability tests were analyzed. The data records were selected to provide information on the accuracy of reduced frequency and decay coefficients as a function of modal damping level, modal frequency, number of modes present in the time history record, proximity to other modes with different frequencies, steady offset in time history, and signal-to-noise ratio. The study utilized the results from each of the major U.S. helicopter manufacturers, the U.S. Army Aeroflightdynamics Directorate, and NASA Ames Research Center using their inhouse data reduction and analysis techniques. Consequently, the accuracy of different data analysis techniques and the manner in which they were implemented were also evaluated. It was found that modal frequencies can be accurately determined even in the presence of significant random and periodic noise. Identified decay coefficients do, however, show considerable variation, particularly for highly damped modes. The manner in which the data are reduced and the role of the data analyst was shown to be important. Although several different damping determination methods were used, no clear trends were evident for the observed differences between the individual analysis techniques. It is concluded that the data reduction of modal-damping characteristics from transient time histories results in a range of damping values.

Warmbrodt, William↗

WRF-simulated low-level jets over Iowa: characterization and sensitivity studies

Abstract. Output from 6 months of high-resolution simulations with the Weather Research and Forecasting (WRF) model are analyzed to characterize local low-level jets (LLJs) over Iowa for winter and spring in the contemporary climate. Low-level jets affect rotor plane aerodynamic loading, turbine structural loading and turbine performance, and thus accurate characterization and identification are pertinent. Analyses using a detection algorithm wherein the wind speed above and below the jet maximum must be below 80 % of the jet wind speed within a vertical window of approximately 20–530 m a.g.l. (above ground level) indicate the presence of an LLJ in at least one of the 14 700 4 km×4 km grid cells over Iowa on 98 % of nights. Nocturnal LLJs are most frequently associated with stable stratification and low turbulent kinetic energy (TKE) and hence are more frequent during the winter months. The spatiotemporal mean LLJ maximum (jet core) wind speed is 9.55 m s−1, and the mean height is 182 m. Locations of high LLJ frequency and duration across the state are seasonally varying, with a mean duration of 3.5 h. The highest frequency occurs in the topographically complex northwest of the state in winter and in the flatter northeast of the state in spring. Sensitivity of LLJ characteristics to the (i) LLJ definition and (ii) vertical resolution at which the WRF output is sampled is examined. LLJ definitions commonly used in the literature are considered in the first sensitivity analysis. These sensitivity analyses indicate that LLJ characteristics are highly variable with definition. Use of different definitions identifies both different frequencies of LLJs and different LLJ events. Further, when the model output is down-sampled to lower vertical resolution, the mean jet core wind speed height decreases, but spatial distributions of regions of high frequency and duration are conserved. Implementation of a polynomial interpolation to extrapolate down-sampled output to full-resolution results in reduced sensitivity of LLJ characteristics to down-sampling.

17 WIND ENERGY↗

Precision controlled atomic resolution scanning transmission electron microscopy using spiral scan pathways

Atomic-resolution imaging in an aberration-corrected scanning transmission electron microscope (STEM) can enable direct correlation between atomic structure and materials functionality. The fast and precise control of the STEM probe is, however, challenging because the true beam location deviates from the assigned location depending on the properties of the deflectors. To reduce these deviations, i.e. image distortions, we use spiral scanning paths, allowing precise control of a sub-Å sized electron probe within an aberration-corrected STEM. Although spiral scanning avoids the sudden changes in the beam location (fly-back distortion) present in conventional raster scans, it is not distortion-free. “Archimedean” spirals, with a constant angular frequency within each scan, are used to determine the characteristic response at different frequencies. We then show that such characteristic functions can be used to correct image distortions present in more complicated constant linear velocity spirals, where the frequency varies within each scan. Through the combined application of constant linear velocity scanning and beam path corrections, spiral scan images are shown to exhibit less scan distortion than conventional raster scan images. The methodology presented here will be useful for in situ STEM imaging at higher temporal resolution and for imaging beam sensitive materials.

47 OTHER INSTRUMENTATION↗

Moving electron density gratings induced in the beat-wave field of two counterpropagating laser pulses

The production and physical characteristics of moving electron density gratings (MEDGs) are investigated by analytical model and particle-in-cell (PIC) simulations. When the frequency difference of two counterpropagating pump pulses is equal to the electron plasma frequency, large amplitude electron plasma wave is resonantly excited in the plasma. As a result, electrons are excited to form a moving, gratinglike structure in the interfering region of pump pulses, while the ions keep at rest. The spatial period and velocity of the MEDG are obtained by solving the electron density modulation equation, which agrees well with one-dimensional PIC simulation results. When a short signal laser pulse is scattered on the MEDG, the frequency of the backscattering wave shifts due to the stimulated Raman scattering.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Ku band pulsed electron paramagnetic resonance spectrometer using an arbitrary waveform generator for quantum control experiments at millikelvin temperatures

We present a 17 GHz (Ku band) arbitrary waveform pulsed electron paramagnetic resonance spectrometer for experiments down to millikelvin temperatures. The spectrometer is located at room temperature, while the resonator is placed either in a room temperature magnet or inside a cryogen-free dilution refrigerator; the operating temperature range of the dilution unit is from ca. 10 mK to 8 K. This combination provides the opportunity to perform quantum control experiments on electron spins in the pure-state regime. At 0.6 T, spin echo experiments were carried out using γ-irradiated quartz glass from 1 K to 12.3 mK. With decreasing temperatures, we observed an increase in spin echo signal intensities due to increasing spin polarizations, in accordance with theoretical predictions. Through experimental data fitting, thermal spin polarization at 100 mK was estimated to be at least 99%, which was almost pure state. Next, to demonstrate the ability to create arbitrary waveform pulses, we generate a shaped pulse by superposing three Gaussian pulses of different frequencies. The resulting pulse was able to selectively and coherently excite three different spin packets simultaneously—a useful ability for analyzing multi-spin system and for controlling a multi-qubit quantum computer. By applying this pulse to the inhomogeneously broadened sample, we obtain three well-resolved excitations at 8 K, 1 K, and 14 mK.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single biphoton ququarts as either pure or mixed states

We analyze features of mixed biphoton polarization states, which arise from pure states of polarization-frequency biphoton ququarts after averaging over frequencies of photons. For mixed states, we find their concurrence C, Schmidt parameter K, degree of polarization P, as well as the von Neumann mutual information I. In some simple cases, we also find the relative entropy S{sub rel} and the degree of classical correlations C{sub cl}. In mixed states, the Schmidt parameter does not characterize the degree of entanglement anymore, as it does in pure states. Nevertheless, the Schmidt parameter remains useful even in the case of mixed states because it remains directly related to the degree of polarization. We compare results occurring in the cases of full pure polarization-frequency states of ququarts and mixed states (averaged over frequencies). Differences between these results can be seen in experiments with and without frequency filters in front of a detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗