Search NASA⌕ Search

SEARCH · Search NASA

Results for “diode model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Optical Measurements at the Combustor Exit of the HIFiRE 2 Ground Test Engine

The development of optical techniques capable of measuring in-stream flow properties of air breathing hypersonic engines is a goal of the Aerospace Propulsion Division at AFRL. Of particular interest are techniques such as tunable diode laser absorption spectroscopy that can be implemented in both ground and flight test efforts. We recently executed a measurement campaign at the exit of the combustor of the HIFiRE 2 ground test engine during Phase II operation of the engine. Data was collected in anticipation of similar data sets to be collected during the flight experiment. The ground test optical data provides a means to evaluate signal processing algorithms particularly those associated with limited line of sight tomography. Equally important, this in-stream data was collected to compliment data acquired with surface-mounted instrumentation and the accompanying flowpath modeling efforts-both CFD and lower order modeling. Here we discuss the specifics of hardware and data collection along with a coarse-grained look at the acquired data and our approach to processing and analyzing it.

Brown, Michael S.↗

Modeling of THz Lasers Based on Intersubband Transitions in Semiconductor Quantum Wells

In semiconductor quantum well structures, the intersubband energy separation can be adjusted to the terahertz (THz) frequency range by changing the well width and material combinations. The electronic and optical properties of these nanostructures can also be controlled by an applied dc electric field. These unique features lead to a large frequency tunability of the quantum well devices. In the on-going project of modeling of the THz lasers, we investigate the possibility of using optical pumping to generate THz radiation based on intersubband transitions in semiconductor quantum wells. We choose the optical pumping because in the electric current injection it is difficult to realize population inversion in the THz frequency range due to the small intersubband separation (4-40 meV). We considered both small conduction band offset (GaAs/AlGaAs) and large band offset (InGaAs/AlAsSb) quantum well structures. For GaAs/AlGaAs quantum wells, mid-infrared C02 lasers are used as pumping sources. For InGaAs/AlAsSb quantum wells, the resonant intersubband transitions can be excited by the near-infrared diode lasers. For three- and four-subband quantum wells, we solve the pumpfield-induced nonequilibrium distribution function for each subband of the quantum well system from a set of rate equations that include both intrasubband and intersubband relaxation processes. Taking into account the coherent interactions between pump and THz (signal) waves, we calculate the optical gain for the THz field. The gain arising from population inversion and stimulated Raman processes is calculated in a unified manner. A graph shows the calculated THz gain spectra for three-subband GaAs/AlGaAs quantum wells. We see that the coherent pump and signal wave interactions contribute significantly to the gain. The pump intensity dependence of the THz gain is also studied. The calculated results are shown. Because of the optical Stark effect and pump-induced population redistribution, the maximum THz gain saturates at larger pump intensities.

Liu, Ansheng↗

The Aquarius Salinity Retrieval Algorithm: Early Results

The Aquarius L-band radiometer/scatterometer system is designed to provide monthly salinity maps at 150 km spatial scale to a 0.2 psu accuracy. The sensor was launched on June 10, 2011, aboard the Argentine CONAE SAC-D spacecraft. The L-band radiometers and the scatterometer have been taking science data observations since August 25, 2011. The first part of this presentation gives an overview over the Aquarius salinity retrieval algorithm. The instrument calibration converts Aquarius radiometer counts into antenna temperatures (TA). The salinity retrieval algorithm converts those TA into brightness temperatures (TB) at a flat ocean surface. As a first step, contributions arising from the intrusion of solar, lunar and galactic radiation are subtracted. The antenna pattern correction (APC) removes the effects of cross-polarization contamination and spillover. The Aquarius radiometer measures the 3rd Stokes parameter in addition to vertical (v) and horizontal (h) polarizations, which allows for an easy removal of ionospheric Faraday rotation. The atmospheric absorption at L-band is almost entirely due to O2, which can be calculated based on auxiliary input fields from numerical weather prediction models and then successively removed from the TB. The final step in the TA to TB conversion is the correction for the roughness of the sea surface due to wind. This is based on the radar backscatter measurements by the scatterometer. The TB of the flat ocean surface can now be matched to a salinity value using a surface emission model that is based on a model for the dielectric constant of sea water and an auxiliary field for the sea surface temperature. In the current processing (as of writing this abstract) only v-pol TB are used for this last process and NCEP winds are used for the roughness correction. Before the salinity algorithm can be operationally implemented and its accuracy assessed by comparing versus in situ measurements, an extensive calibration and validation (cal/val) activity needs to be completed. This is necessary in order to tune the inputs to the algorithm and remove biases that arise due to the instrument calibration, foremost the values of the noise diode injection temperatures and the losses that occur in the feedhorns. This is the subject of the second part of our presentation. The basic tool is to analyze the observed difference between the Aquarius measured TA and an expected TA that is computed from a reference salinity field. It is also necessary to derive a relation between the scatterometer backscatter measurements and the radiometer emissivity that is induced by surface winds. In order to do this we collocate Aquarius radiometer and scatterometer measurements with wind speed retrievals from the WindSat and SSMIS F17 microwave radiometers. Both of these satellites fly in orbits that have the same equatorial ascending crossing time (6 pm) as the Aquarius/SAC-D observatory. Rain retrievals from WindSat and SSMIS F 17 can be used to remove Aquarius observations that are rain contaminated. A byproduct of this analysis is a prediction for the wind-induced sea surface emissivity at L-band.

Meissner, Thomas↗

Near UV atmospheric absorption measurements from the DC-8 aircraft during the 1987 airborne Antarctic ozone experiment

During the Airborne Antarctic Ozone Experiment from 28 August to 30 September 1987 near UV zenith scattered sky measurements were made over Antarctic from the NASA DC-8 aircraft using a one third m spectrograph equipped with a diode-array detector. Scattered sky light data in the wavelength range 348 nm to 388 nm was spectrally analyzed for O3, NO2, OClO, and BrO column abundances. Slant column abudances of O3, NO2, OClO and BrO were determined, using a computer algorithm of non-linear and linear least square correlation of Antarctic scattered sky spectra to laboratory absorption cross section data. Using measured vertical electrochemical sonde ozone profiles from Palmer, Halley Bay, and the South Pole Stations the slant columns of O3 were converted into vertical column abundances. The vertical column amounts of NO2, OClO, and BrO were derived using vertical profiles calculated by a chemical model appropriate for Antarctica. NO2 vertical column abundances show steep latitudinal decrease with increasing latitude for all 13 flights carried out during the mission. In the regions where NO2 abudances are low, OClO and BrO were observed. The spatial and temporal vertical column abundances of these species are discussed in the context of the chemistry and dynamics in the antarctic polar vortex during the austral spring.

Wahner, A.↗

Experiments with Lasers and Frequency Doublers

Solid state laser sources, such as diode-pumped Nd:YAG lasers, have given us CW laser light of high power with unprecedented stability and low noise performance. In these lasers most of the technical sources of noise can be eliminated allowing them to be operated close to the theoretical noise limit set by the quantum properties of light. The next step of reducing the noise below the standard limit is known as squeezing. We present experimental progress in generating reliably squeezed light using the process of frequency doubling. We emphasize the long term stability that makes this a truly practical source of squeezed light. Our experimental results match noise spectra calculated with our recently developed models of coupled systems which include the noise generated inside the laser and its interaction with the frequency doubler. We conclude with some observations on evaluating quadrature squeezed states of light.

Bachor, H.-A.↗

Reliability and performance experience with flat-plate photovoltaic modules

Statistical models developed to define the most likely sources of photovoltaic (PV) array failures and the optimum method of allowing for the defects in order to achieve a 20 yr lifetime with acceptable performance degradation are summarized. Significant parameters were the cost of energy, annual power output, initial cost, replacement cost, rate of module replacement, the discount rate, and the plant lifetime. Acceptable degradation allocations were calculated to be 0.0001 cell failures/yr, 0.005 module failures/yr, 0.05 power loss/yr, a 0.01 rate of power loss/yr, and a 25 yr module wear-out length. Circuit redundancy techniques were determined to offset cell failures using fault tolerant designs such as series/parallel and bypass diode arrangements. Screening processes have been devised to eliminate cells that will crack in operation, and multiple electrical contacts at each cell compensate for the cells which escape the screening test and then crack when installed. The 20 yr array lifetime is expected to be achieved in the near-term.

Ross, R. G., Jr.↗

Non-Micropipe Dislocations in 4H-SiC Devices: Electrical Properties and Device Technology Implications

It is well-known that SiC wafer quality deficiencies are delaying the realization of outstandingly superior 4H-SiC power electronics. While efforts to date have centered on eradicating micropipes (i.e., hollow core super-screw dislocations with Burgers vectors greater than or equal to 2c), 4H-SiC wafers and epilayers also contain elementary screw dislocations (i.e., Burgers vector = 1c with no hollow core) in densities on the order of thousands per sq cm, nearly 100-fold micropipe densities. While not nearly as detrimental to SiC device performance as micropipes, it has recently been demonstrated that elementary screw dislocations somewhat degrade the reverse leakage and breakdown properties of 4H-SiC p(+)n diodes. Diodes containing elementary screw dislocations exhibited a 5% to 35% reduction in breakdown voltage, higher pre-breakdown reverse leakage current, softer reverse breakdown I-V knee, and microplasmic breakdown current filaments that were non-catastrophic as measured under high series resistance biasing. This paper details continuing experimental and theoretical investigations into the electrical properties of 4H-SiC elementary screw dislocations. The nonuniform breakdown behavior of 4H-SiC p'n junctions containing elementary screw dislocations exhibits interesting physical parallels with nonuniform breakdown phenomena previously observed in other semiconductor materials. Based upon experimentally observed dislocation-assisted breakdown, a re-assessment of well-known physical models relating power device reliability to junction breakdown has been undertaken for 4H-SiC. The potential impact of these elementary screw dislocation defects on the performance and reliability of various 4H-SiC device technologies being developed for high-power applications will be discussed.

Neudeck, Philip G.↗

Single-Photon Counting Detector Scalability for High Photon Efficiency Optical Communications Links

For high photon-efficiency deep space or low power optical communications links, such as the Orion Artemis-2 Optical Communications System (O2O) project, the received optical signal is attenuated to the extent that single- photon detectors are required. For direct-detection receivers operating at 1.55 µm wavelength, single-photon detectors including Geiger-mode InGaAs avalanche photon diodes (APDs), and in particular superconducting nanowire single-photon detectors (SNSPDs) offer the highest sensitivity and fastest detection speeds. However, these photon detectors exhibit a recovery time between registered input pulses, effectively reducing the detection efficiency over the recovery interval, resulting in missed photon detections, reduced count rate, and ultimately limiting the achievable data rate. A method to overcome this limitation is to divide the received optical signal into multiple detectors in parallel. Here we analyze this approach for a receiver designed to receive a high photon efficiency serially concatenated pulse position modulation (SCPPM) input waveform. From measured count rate and efficiency data using commercial SNSPDs, we apply a model from which we determine the effective detection efficiency, or blocking loss, for different input signal rates. We analyze the scalability of adding detectors in parallel for different modulation orders and background levels to achieve desired data rates. Finally we show tradeoffs between the number of detectors and the required received optical power, useful for real link design considerations.

Vyhnalek, Brian E.↗

Pulse Response of the Short-Wave Infrared Detection System of the Ocean Color Instrument for the NASA PACE Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission is a hyperspectral Earth imager with a spatial resolution of 1 km x 1 km and a spectral resolution of 5 nm in 2.5 nm steps over 342-887 nm. In addition, OCI provides 7 discrete bands in the 940-2260 nm Short-Wave InfraRed (SWIR) range. The front-end optical imager is a rotating mirror-based system that images the ground scene onto a slit with an instantaneous field of view of 16 km x 1 km. For the SWIR bands, the slit-image is re-imaged onto a 16x1 micro-lens array that effectively acts as the focal plane since each lens element is fiber coupled to wavelength filtered InGaAs and HgCdTe Photo Diodes (PDs). The pulse response of the detection system is critical to OCI SWIR performance. We find that PDs introduce an inherent slow tail in the pulse response due to slow diffusion moving carriers in their n and p regions. We show that this introduces response errors ranging from 1 down to 0.01 % for up to tens of science pixels after the pulse depending on the PD design and materials. It is shown that the response is distinctly different for the InGaAs and HgCdTe PDs. We explain how the front-end design can further increase this error. Finally, we detail the cause of the slow pulse response tail, how to model it, its impact on OCI performance and how it is characterized and corrected to meet OCI requirements.

ocean color↗

Pulse Response of the Short-Wave Infrared Detection System of the Ocean Color Instrument for the NASA Pace Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission is a hyperspectral Earth imager with a spatial resolution of 1 km x 1 km and a spectral resolution of 5 nm in 2.5 nm steps over 342-887 nm. In addition, OCI provides 7 discrete bands in the 940-2260 nm Short-Wave InfraRed (SWIR) range. The front-end optical imager is a rotating mirror-based system that images the ground scene onto a slit with an instantaneous field of view of 16 km x 1 km. For the SWIR bands, the slit-image is re-imaged onto a 16x1 micro-lens array that effectively acts as the focal plane since each lens element is fiber coupled to wavelength filtered InGaAs and HgCdTe Photo Diodes (PDs). The pulse response of the detection system is critical to OCI SWIR performance. We find that PDs introduce an inherent slow tail in the pulse response due to slow diffusion moving carriers in their n and p regions. We show that this introduces response errors ranging from 1 down to 0.01 % for up to tens of science pixels after the pulse depending on the PD design and materials. It is shown that the response is distinctly different for the InGaAs and HgCdTe PDs. We explain how the front-end design can further increase this error. Finally, we detail the cause of the slow pulse response tail, how to model it, its impact on OCI performance and how it is characterized and corrected to meet OCI requirements.

ocean color↗

Super high compression of line drawing data

Models which can be used to accurately represent the type of line drawings which occur in teleconferencing and transmission for remote classrooms and which permit considerable data compression were described. The objective was to encode these pictures in binary sequences of shortest length but such that the pictures can be reconstructed without loss of important structure. It was shown that exploitation of reasonably simple structure permits compressions in the range of 30-100 to 1. When dealing with highly stylized material such as electronic or logic circuit schematics, it is unnecessary to reproduce configurations exactly. Rather, the symbols and configurations must be understood and be reproduced, but one can use fixed font symbols for resistors, diodes, capacitors, etc. Compression of pictures of natural phenomena such as can be realized by taking a similar approach, or essentially zero error reproducibility can be achieved but at a lower level of compression.

Cooper, D. B.↗

Lessons Learned from the Aquarius Radiometer Engineering Model

The Aquarius instrument is a combination microwave radiometer and scatterometer operating in the L-band for the measurement of sea surface salinity (SSS) over the open-ocean. "The Aquarius science goals are to observe and model the processes that relate salinity variations to climatic changes in the global cycling of water and to understand how these variations influence the general ocean circulation. By measuring salinity globally and synoptically every month for 3 years, Aquarius will provide an unprecedented new view of the ocean's role in climate." (http://aquarius.asfc.nasa.gov on Jan. 4, 2007). To launch in 2009, Aquarius will provide 8-day global coverage and monthly-averaged salinity maps at approx.120-km spatial resolution. Because the microwave emissivity of the ocean surface is weakly dependent upon salinity, the Aquarius radiometer remain sufficiently stable to provide accurate salinity measurements. An engineering model (EM) of one radiometer receiver was developed and tested for functionality and performance at NASA's Goddard Space Flight Center. It was tested for long-term stability starting July 27,2006. Two discrepancies where found at the start of testing and a four-month correction process ensued. This paper covers the testing and debugging of the EM radiometer through resolution of the problems. The radiometer is required to have calibration stability of less than or equal to 0.15 K over 7 days. The radiometer is in a three-beam push-broom configuration with each beam being an independent three-state Dicke radiometer (antenna, reference load, and additive noise). Internal noise diodes and reference loads provide periodic and rapid calibration of the receiver. Front-end loss contributions must be corrected as the lossy components are outside the calibration loop. A key design feature for obtaining stability is active thermal control of the front-end lossy components and the RF receiver. The thermal stability is predicted to be about 0.1 C over an orbit and no more than 1 C over a year. The radiometric stability requirement is 0.13 K rms 1 7 days without using temperature corrections. Temperature corrections and post-launch calibration are expected to extend the stability period through the life of the mission.

Piepmeier, Jeffrey↗

The JPL Field Emission Spectrometer

The Jet Propulsion Laboratory (JPL) Field Emission Spectrometer (FES) was built by Designs and Prototypes based on a set of functional requirements supplied by JPL. The instrument has a spectral resolution of 6 wavenumbers (wn) and can acquire spectra from either the Mid Infrared (3-5 mu m) or the Thermal Infrared (8-12 pm) depending on whether the InSb or HgCdTe detector is installed respectively. The instrument consists of an optical head system unit and battery. The optical head which is tripod mounted includes the interferometer and detector dewar assembly. Wavelength calibration of the interferometer is achieved using a Helium-Neon laser diode. The dewar needs replenishing with liquid Nitrogen approximately every four hours. The system unit includes the controls for operation and the computer used for acquiring viewing and processing spectra. Radiometric calibration is achieved with an external temperature-controlled blackbody that mounts on the fore-optics of the instrument. The blackbody can be set at 5 C increments between 10 and 55 C. The instrument is compact and weighs about 33 kg. Both the wavelength calibration and radiometric calibration of the instrument have been evaluated. The wavelength calibration was checked by comparison of the position of water features in a spectrum of the sky with their position in the output from a high resolution atmospheric model. The results indicatethat the features in the sky spectrum are within 6-8 wn of their position ill the model spectrum. The radiometric calibration was checked by first calibrating the instrument using the external blackbody supplied with the instrument and then measuring the radiance from another external blackbody at a series of temperatures. The temperatures of these radiance spectra were then recovered by inventing Planck's law and the recovered temperatures compared lo the measured blackbody temperature. These results indicate that radiometric calibration is good to 0.5 C over the range of temperatures 10 to 55 C. The results also indicate that the instrument drifts slowly over time and should be recalibrated every 20 to 30 minutes in the field to ensure good radiometric fidelity. The instrument has now been extensively tested in the field in the United States and Australia. These in situ field measurements are being used to validate emissivity spectra recovered from the Thermal Infrared Multispectral Scanner (TIMS) and also the Australian CO2 Laser. The availability of in situ measurements is proving crucial to validation of the spectra derived from the airborne instruments since many natural surfaces cannot be easily transported back to the laboratory.

Hook, Simon J.↗

The dc power control for a liquid-fed resistojet

A simple breadboard power controller was designed and demonstrated for a new liquid-fed water resistojet. The 1-piece laboratory model thruster has an integrated vaporizer/superheater using a single heating element. Heater temperature was maintained at or near a preset reference value with the closed loop controller providing pulse width modulated (PWM) dc power into the thruster heater. A combined thruster, temperature readout, PWM transfer function was experimentally determined. This transfer function was used to design a proportional plus integral controller that demonstrated zero steady state error, conservative stability margins and adequate transient response to step changes in propellant flow rate, input voltage and temperature reference. Initial turn-on temperature overshoot from room temperature to a 650 C setpoint was 80 C. In addition, EMI was alleviated by reducing heater dI/dt and dV/dt using a simple diode-inductor-capacitor network. Based on limited initial tests, thruster preheat with no propellant flow was necessary to achieve stable system operation during startup. Breadboard power efficiency was 99 percent at 1 kW, and component mass was 0.4 kg excluding the power loss and mass of an input filter required for spacecraft integration.

Gruber, Robert P.↗

dc power control for a liquid-fed resistojet

A simple breadboard power controller was designed and demonstrated for a new liquid-fed water resistojet. The 1-piece laboratory model thruster has an integrated vaporizer/superheater using a single heating element. Heater temperature was maintained at or near a preset reference value with the closed loop controller providing pulse width modulated (PWM) dc power into the thruster heater. A combined thruster, temperature readout, PWM transfer function was experimentally determined. This transfer function was used to design a proportional plus integral controller that demonstrated zero steady state error, conservative stability margins and adequate transient response to step changes in propellant flow rate, input voltage and temperature reference. Initial turn-on temperature overshoot from room temperature to a 650 C setpoint was 80 C. In addition, EMI was alleviated by reducing heater dI/dt and dV/dt using a simple diode-inductor-capacitor network. Based on limited initial tests, thruster preheat with no propellant flow was necessary to achieve stable system operation during startup. Breadboard power efficiency was 99 percent at 1 kW, and component mass was 0.4 kg excluding the power loss and mass of an input filter required for spacecraft integration.

Gruber, Robert P.↗

MARS 2020 Backshell Radiative Heating Measurement and Shock Tube Verification

In February 2021, the Perseverance rover was brought to the surface of Mars by the Mars 2020 mission. A feature of the Mars 2020 capsule was instrumentation to measure its entry, descent and landing (EDL) with the so-called Mars EDL Instrumentation 2 (MEDLI2) [1]. The MEDLI2 introduced, among other things, backshell instrumentation, including a broadband radiometer. The radiometer was mounted on the leeside of the vehicle next to thermocouple plugs and a heat flux gauge. The data returned by the leeside MEDLI2 heat flux gauge is largely analogous to that measured by the COMARS gauge flown on the ExoMars Schiaparelli [2] entry in that it is measuring heat flux in an area that is entirely dominated by radiative heating. The COMARS measurement provided excellent validation of backshell radiative heating models for Mars entry, albeit at a limited number of points [3]. The MEDLI2 heat flux gauge measurement effectively confirmed the quality of the prediction, extended over the full trajectory, as will be presented in this paper. The MEDLI2 radiometer,however, was blocked by ablation products and suffered a loss of half of its signal. The second backshell heat flux gauge installed on the windside of the vehicle was also well predicted, although the heating had both radiative and convective contributions. It was desired to reproduce the conditions of the Mars 2020 entry via ground testing in the Electric Arc Shock Tube (EAST) at NASA Ames. Tests to verify stagnation line heating were previously reported in EAST, confirming the presence of shock layer radiation as the major discrepancy in heatshield temperature modelling [4]. Therefore, tests for stagnation line heating were not repeated. Instead, the shock tube informed bias method [5, 6] was used to identify test conditions that may produce similarity to streamlines that pass around the backside of the vehicle and are responsible for the radiation observed at the two heat flux gauge locations. This method was used to identify a range of velocities and densities in the shock tube that are relevant for confirming the radiative environment encountered. This paper reports the results obtained in the 10 cm diameter EAST shock tube, corresponding to later trajectory points at ambient pressures of 1.1-2.0 Torr and velocities from 1.2-3.5 km/s. The test series employed two primary diagnostics: emission spectroscopy and tunable diode laser absorption spectroscopy (TDLAS). The emission spectroscopy performed broadband measurements of the radiative emission of the 4.3 and 2.7 m bands of CO2 at flight similar conditions, obtaining both spectral and spatial data corresponding to the relaxation behind the shock front. The TDLAS measured the absorption of several lines of CO and CO2 and obtains species number densities and temperatures as a function of time behind the shock front. This paper will review highlights of this test series and analyses of the emission and absorption data. While the datasets generally show good agreement with predictions, a few discrepancies and items for additional investigation are identified and will be discussed

Brett A Cruden↗

Sunspot bright rings and the thermal diffusivity of solar convection

Raster-scan observations of 10 sunspots, made in 1980 and 1981 with the 512-channel diode array and vacuum telescope at the Kitt Peak National Observatory, are reported. Data from several 10-min scans of 0.25-A passbands of clean continuum were summed to give an rms noise level of 0.25 percent, corrected by applying a limb-darkening curve, and analyzed to determine the average intensity for each of eight segments of a series of concentric rings around each sunspot. Faculae and pores were identified and discarded in constructing radial intensity profiles. Marginally significant bright symmetric rings (peak amplitude 0.1-0.3 percent) not attributable to residual facular signal or instrumental effects were observed around 6 of 10 sunspots. No evidence of more intense bright rings was found. These findings are discussed in terms of thermal-diffusion models proposed to explain the fate of the radiative flux blocked by sunspots.

Duvall, T., Jr.↗

Streak camera based SLR receiver for two color atmospheric measurements

To realize accurate two-color differential measurements, an image digitizing system with variable spatial resolution was designed, built, and integrated to a photon-counting picosecond streak camera, yielding a temporal scan resolution better than 300 femtosecond/pixel. The streak camera is configured to operate with 3 spatial channels; two of these support green (532 nm) and uv (355 nm) while the third accommodates reference pulses (764 nm) for real-time calibration. Critical parameters affecting differential timing accuracy such as pulse width and shape, number of received photons, streak camera/imaging system nonlinearities, dynamic range, and noise characteristics were investigated to optimize the system for accurate differential delay measurements. The streak camera output image consists of three image fields, each field is 1024 pixels along the time axis and 16 pixels across the spatial axis. Each of the image fields may be independently positioned across the spatial axis. Two of the image fields are used for the two wavelengths used in the experiment; the third window measures the temporal separation of a pair of diode laser pulses which verify the streak camera sweep speed for each data frame. The sum of the 16 pixel intensities across each of the 1024 temporal positions for the three data windows is used to extract the three waveforms. The waveform data is processed using an iterative three-point running average filter (10 to 30 iterations are used) to remove high-frequency structure. The pulse pair separations are determined using the half-max and centroid type analysis. Rigorous experimental verification has demonstrated that this simplified process provides the best measurement accuracy. To calibrate the receiver system sweep, two laser pulses with precisely known temporal separation are scanned along the full length of the sweep axis. The experimental measurements are then modeled using polynomial regression to obtain a best fit to the data. Data aggregation using normal point approach has provided accurate data fitting techniques and is found to be much more convenient than using the full rate single shot data. The systematic errors from this model have been found to be less than 3 ps for normal points.

Varghese, Thomas K.↗