Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed decision making”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Self-Organizing Map-Based Resilience Quantification and Resilient Control of Distribution Systems Under Extreme Events

Due to climate change, extreme weather events are occurring more frequently and with increasing impact. This trend poses a significant challenge for distribution system operators (DSO) to ensure that there is uninterrupted power supply to critical loads in their networks. To embed resilience into DSO's decision-making, resilience needs to be first quantified and then integrated into the system-level optimization. Therefore, this paper first develops a novel self-organizing map (SOM) based method (called SomRes) to quantify the time-varying resilience index of a system that can leverage the powerful classification property of SOMs and removes some of the disadvantages of subjective weight assignment methods. Using SomRes, a resilient resource allocation and operational dispatch algorithm is further developed to enhance system resilience against extreme events by considering the SomRes resilience index directly as the feedback. Here, the proposed resilience quantification approach is benchmarked with a state-of-the-art approach and the efficacy of the proposed resilient dispatch algorithm is demonstrated through several deterministic and statistical case studies on the IEEE 123-bus distribution system. Simulation studies show that the proposed SomRes quantification method is an appropriate indicator of system resilience, and the resilient resource allocation and dispatch strategy can significantly reduce critical load shedding under varying event propagation scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Transactive Energy Network Template Metamodel

While transactive energy, which is defined as an allocation of electricity based on dynamically discovered values or prices, has been extensively studied, its uptake and use has been slow. This report describes a tool, the transactive network template, which should hasten the creation and uptake of transactive energy networks. Some basic principles of transactive energy are familiar from existing wholesale electricity markets. Locational prices are calculated today for zones within bulk electric transmission systems. Locational prices differ while accounting for the locational costs of electricity generation and the losses and constraints incurred when electricity is transmitted from generators and distributed to consumers. A transactive energy network might include these transmission zones. However, current research strives to apply transactive energy also in electricity distribution circuits, buildings, and even for individual generating and consuming devices. At the same time, researchers explore how to apply transactive energy in real time during increasingly shorter time intervals. Automated computational agents become necessary as transactive energy becomes applied to smaller circuit zones and at faster dynamic timescales. A transactive energy network is an example of a multi-agent system. Each zone in the network is represented by its transactive agent, which makes decisions for and acts on behalf of a business entity that is responsible for and manages one of the circuit regions. A transactive energy network is also an example of a decentralized, distributed control system. Control decisions and responsibilities are distributed among the network’s transactive agents. The transactive agents are independent; that is, there typically is no centralized authority or oversight function. Instead, transactive agents exchange transactive signals and thereby negotiate the prices and quantities of electricity that they will exchange. Initially, the circuit regions and responsibilities of transactive agents appear to be very dissimilar. Each circuit region may comprise transmission, distribution, or building-level circuits. Each has a unique position and electrical connectivity within the transactive energy network. Each possesses unique assets that either generate or consume electricity, and these (e.g., renewable energy generator, diesel generator, aggregate utility load, building load, space conditioning, refrigerator, etc.) may further differ in their price flexibility and in their strategies for responding to dynamic electricity prices. Given such diversity, an implementer’s first inclination might be to start from scratch to define all these devices and to engineer their seemingly unique interactions. Given that each implementer’s perspective may be narrow within a transactive energy network, it is unlikely that uniquely engineered systems would interact well. This is where the transactive network template is applicable. The transactive network template is a metamodel that has been developed to guide implementers as they configure their own transactive agent within a network of such agents. The object-oriented design of the transactive network template provides basic code object types that may be used and extended by implementers to represent each of the assets in their circuit region. These objects further facilitate the transactive agent’s necessary computations, which are divided among responsibilities to schedule power usage, balance electric supply and demand, and coordinate the exchange of electricity with the other transactive agents. This report addresses the conceptual transactive network template design. Implementers are directed to more formal design documents and reference implementations. A Python™-based1 reference implementation of the transactive network template has been coded, and three implementations have been configured to represent a national laboratory and two university campuses. Version 2 of the transactive node template generalizes the market class and its methods to facilitate multiple, and more diverse market coordination mechanisms than were facilitated by and demonstrated using Version 1. Version 3 includes new Appendix B, which addresses the designs of methods that would make dynamic prices track approved electricity rates. In the future, the author wishes to make the transactive network template more generally applicable to networks that require more accurate power flow. Development of the transactive network template is jointly funded by the U.S. Department of Energy (DOE) Energy Efficiency and Renewable Energy and the DOE Office of Electricity. In late 2015, one of the first projects to be funded by the DOE Grid Laboratory Modernization Laboratory Consortium was the Clean Energy and Transactive Campus project, led by Pacific Northwest National Laboratory. DOE funds were matched by an investment by the Washington Department of Commerce through its Clean Energy Fund. The transactive network template was developed to guide the implementation of transactive energy networks within this project’s scope.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterization and Valuation of the Uncertainty of Calibrated Parameters in Microsimulation Decision Models

We evaluated the implications of different approaches to characterize the uncertainty of calibrated parameters of microsimulation decision models (DMs) and quantified the value of such uncertainty in decision making. We calibrated the natural history model of CRC to simulated epidemiological data with different degrees of uncertainty and obtained the joint posterior distribution of the parameters using a Bayesian approach. We conducted a probabilistic sensitivity analysis (PSA) on all the model parameters with different characterizations of the uncertainty of the calibrated parameters. We estimated the value of uncertainty of the various characterizations with a value of information analysis. We conducted all analyses using high-performance computing resources running the Extreme-scale Model Exploration with Swift (EMEWS) framework. The posterior distribution had a high correlation among some parameters. The parameters of the Weibull hazard function for the age of onset of adenomas had the highest posterior correlation of -0.958. When comparing full posterior distributions and the maximum-a-posteriori estimate of the calibrated parameters, there is little difference in the spread of the distribution of the CEA outcomes with a similar expected value of perfect information (EVPI) of $\$$653 and $\$$685, respectively, at a willingness-to-pay (WTP) threshold of $\$$66,000 per quality-adjusted life year (QALY). Ignoring correlation on the calibrated parameters’ posterior distribution produced the broadest distribution of CEA outcomes and the highest EVPI of $\$$809 at the same WTP threshold. Different characterizations of the uncertainty of calibrated parameters affect the expected value of eliminating parametric uncertainty on the CEA. Ignoring inherent correlation among calibrated parameters on a PSA overestimates the value of uncertainty.

97 MATHEMATICS AND COMPUTING↗

Multi-parametric analysis for mixed integer linear programming: An application to transmission upgrade and congestion management

Upgrading the capacity of existing transmission lines is essential for meeting the growing energy demands, facilitating the integration of renewable energy, and ensuring the security of the transmission system. This study focuses on the selection of lines whose capacities and by how much should be expanded from the perspective of the Independent System Operators (ISOs) to minimize the total system cost. We employ advanced multi-parametric programming and an enhanced branch-and-bound algorithm to address complex mixed-integer linear programming (MILP) problems, considering multi-period time constraints and physical limitations of generators and transmission lines. To characterize the various decisions in transmission expansion, we model the increased capacity of existing lines as parameters within a specified range. This study first relaxes the binary variables to continuous variables and applies the Lagrange method and Karush-Kuhn-Tucker (KKT) conditions to obtain optimal solutions and identify critical regions associated with active and inactive constraints. Moreover, we extend the traditional branch-and-bound (B&B) method by determining the problem’s upper and lower bounds at each node of the B&B decision tree, helping to manage computational challenges in large-scale MILP problems. Here, we compare the difference between the upper and lower bounds to obtain an approximate optimal solution within the decision-makers’ tolerable error range. In addition, the first derivative of the objective function on the parameters of each line is used to inform the selection of lines for easing congestion and maximizing social welfare. Finally, the capacity upgrades are selected by weighing the reductions in system costs against the expense of upgrading line capacities. The findings are supported by numerical simulations and provide transmission-line planners with decision-making guidance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

1.2.2.405 HydroWIRES Topic D1: Capacity Expansion Model (CEM) Enhancements

Long-term grid planning tools have difficulty representing detailed hydropower operating characteristics, which depend not only on technological specifications but also on water management practices and regulations. As a result, the value of hydropower is incompletely characterized, and the potential role of hydropower in the performance and resiliency of the future electric grid is not fully understood. This work will fill that gap by developing new ways to represent hydropower resource, technology, and operational characteristics in electric sector capacity expansion models and implementing them in the open-source version of the National Renewable Energy Laboratory's Regional Energy Deployment System (ReEDS) model. ReEDS is a well-established national scale grid planning tool used since 2003 by the U.S. Department of Energy and others to explore the evolution of the U.S. electric sector. Improvements will include a comprehensive national resource assessment for pumped storage hydropower and methods for modeling multiple hydropower technology categories characterized by technical, regulatory, and economic characteristics. The project will provide guiding principles and strategies for improving hydropower modeling in capacity expansion models and deliver a first-of-its kind versatile PSH dataset. All data, code, and methods will be publicly available, allowing the industry to better identify the value of hydropower in the future electricity system and make more informed planning decisions.

capacity expansion↗

Informing Cybersecurity Decisions With the Value-at-Risk Framework

Security at every site is critical to making hydropower a strong contributor to the country's grid, but with ongoing development and expanding capabilities, the diversity of the existing hydropower fleet makes across-the-board investment decisions difficult. The threat of cyberattacks naturally increases as the interconnection of Information Technology and Operational Technology networks broadens. Hydropower plants require custom analyses that are specific to the unique challenges and characteristics of any given facility. Facilities, however, often do not have the necessary resources for managers to make informed decisions on investments based on assessed capabilities and risks.

cybersecurity↗

Integration of On-board EOS Schedule Revision with Space Communication Emulation System

The need for on-board decision-making for planning science observations on Earth Observing Satellites is based on the fact that the desirability of acquiring an image can change dynamically, because of changes in meteorological conditions (e.g. cloud cover), unforeseen events such as fires, floods, or volcanic eruptions, or unexpected changes in satellite or ground station capability. In such cases, satellite resources, such as power and SSR capacity can potentially be better utilized taking another image that is of higher quality. Currently, typical Earth observing satellites cannot communicate directly with each other, and can only communicate with ground stations about 5% to 10% of the time. Because of the limited communication windows, as well as the cost and effort that would need to be expended in revising a mission schedule, a ground-based scheduler would have little or no opportunity to revise the schedule in response to the contingencies that may arise. For this reason, a distributed science planning system combining a ground-based scheduler with on-board schedule revision capabilities is warranted. This paper will describe algorithms for on-board decision-making for science planning and their integration with the advanced satellite control and communications technology developed at the Space Communication Emulation Facility (SCEF) at NASA Glenn Research Center. Our objective of demonstrating how advanced communications and scheduling technology can be combined to improve the scientific utility of images acquired by Earth observing systems will be discussed via a description of a number of realistic flight scenarios.

Khatib, Lina↗

Error Detection and Error Classification: Failure Awareness in Data Transfer Scheduling

Data transfer in distributed environment is prone to frequent failures resulting from back-end system level problems, like connectivity failure which is technically untraceable by users. Error messages are not logged efficiently, and sometimes are not relevant/useful from users point-of-view. Our study explores the possibility of an efficient error detection and reporting system for such environments. Prior knowledge about the environment and awareness of the actual reason behind a failure would enable higher level planners to make better and accurate decisions. It is necessary to have well defined error detection and error reporting methods to increase the usability and serviceability of existing data transfer protocols and data management systems. We investigate the applicability of early error detection and error classification techniques and propose an error reporting framework and a failure-aware data transfer life cycle to improve arrangement of data transfer operations and to enhance decision making of data transfer schedulers.

97 MATHEMATICS AND COMPUTING↗

Fast Determination of Distribution-Connected PV Impacts Using a Variable Time-Step Quasi-Static Time-Series Approach: Preprint

The increasing deployment of distribution-connected photovoltaic (DPV) systems requires utilities to complete complex interconnection studies. Relatively simple interconnection study methods worked well for low penetrations of photovoltaic systems, but more complicated quasi-static time-series (QSTS) analysis is required to make better interconnection decisions as DPV penetration levels increase. Tools and methods must be developed to support this. This paper presents a variable-time-step solver for QSTS analysis that significantly shortens the computational time and effort to complete a detailed analysis of the operation of a distribution circuit with many DPV systems. Specifically, it demonstrates that the proposed variable-time-step solver can reduce the required computational time by as much as 84% without introducing any important errors to metrics, such as the highest and lowest voltage occurring on the feeder, number of voltage regulator tap operations, and total amount of losses realized in the distribution circuit during a 1-yr period. Further improvement in computational speed is possible with the introduction of only modest errors in these metrics, such as a 91 percent reduction with less than 5 percent error when predicting voltage regulator operations.

14 SOLAR ENERGY↗

Governing in Time: Temporal Capacity and the Feasibility of Energy Transitions

Energy systems function as both technological systems and temporal institutions that shape how societies coordinate, justify, and support collective choices over time. This paper introduces the concept of governance horizons to explain why energy transitions can remain morally supported yet become institutionally weak under increasing pressure. We argue that governability depends on institutions' capacity to synchronize across multiple timeframes - aligning short-term decisions with intermediate coordination and long-term commitments. When this synchronization fails, transitions struggle not because their goals are dismissed, but because governance lacks sufficient time to justify, coordinate, and uphold decisions. Comparative analysis of San Antonio, Texas, and Interior Alaska reveals how energy system pressures generate distinct temporal configurations: San Antonio exhibits governance horizon stretching, where institutions must simultaneously meet near-term reliability demands and long-term transformation goals, while Interior Alaska exhibits horizon compression, where extreme environmental constraints force decision-making into short stabilization cycles. In both contexts, public support for sustainability goals coexists with institutional strain because evaluative judgments are unevenly distributed over time. A temporal configuration analysis is introduced as a diagnostic analytic stance for identifying these patterns. By treating temporal alignment as an explanatory variable rather than a background condition, this approach clarifies how feasibility, sequencing, and legitimacy are shaped by constraints on institutional time. The analysis demonstrates that successful energy transitions depend not only on technological innovation or institutional support, but on governance systems’ ability to sustain credible coordination across multiple time horizons.

Comparative case study↗

Assessment of the Current Level of Automation in the Manufacture of Fuel Cell Systems for Combined Heat and Power Applications

The U.S. Department of Energy (DOE) is interested in supporting manufacturing research and development (R&D) for fuel cell systems in the 10-1,000 kilowatt (kW) power range relevant to stationary and distributed combined heat and power applications, with the intent to reduce manufacturing costs and increase production throughput. To assist in future decision-making, DOE requested that theNational Renewable Energy Laboratory (NREL) provide a baseline understanding of the current levels of adoption of automation in manufacturing processes and flow, as well as of continuous processes. NREL identified and visited or interviewed key manufacturers, universities, and laboratories relevant to the study using a standard questionnaire. The questionnaire covered the current level ofvertical integration, the importance of quality control developments for automation, the current level of automation and source of automation design, critical balance of plant issues, potential for continuous cell manufacturing, key manufacturing steps or processes that would benefit from DOE support for manufacturing R&D, the potential for cell or stack design changes to support automation, andthe relationship between production volume and decisions on automation.

30 DIRECT ENERGY CONVERSION↗

Hanford Site Rare Plant Monitoring Report for Calendar Year 2022

Rare plants are monitored on the Hanford Site as distribution and abundance data of current and historic rare plant populations are necessary to make well-informed environmental and ecological resource management decisions. The Central Hanford Rare Plant Management Plan (DOE/RL-2021-35) guides rare plant monitoring methodology in the context of resource management at the Hanford Site. In 2022, a rare plant monitoring effort occurred on the portion of the Hanford Site (referred to herein as Central Hanford) managed by the U.S. Department of Energy, Richland Operations Office (DOE-RL; Figure 1). The goal of this effort was to revisit known occurrences of upland rare plant populations on Central Hanford to improve baseline information on locations of rare plant populations on the Hanford Site. Rare upland plants were thoroughly surveyed in 2021 but unusually low precipitation that year limited germination of many upland annual plants. Surveys in 2022 focused on rare upland annual species after the Hanford Site received higher than average spring precipitation that was expected to increase germination. Rainfall from April 2022 to June 2022 was 76% higher than average; however, these months were also colder than average. Winter rainfall from January 2022 to March 2022 was 84% lower than average. The high spring precipitation in 2022 appears to have triggered the germination of some populations of rare upland annuals but the dry winter and cold spring may have inhibited others. Population stability, viability, and threats were evaluated and will be used to inform future management of rare plant species.

54 ENVIRONMENTAL SCIENCES↗

Integrated Energy-Water Data for Cross-Sector Resilience

This white paper focuses on the “energy-for-water” domain, addressing the urgent need for integrated, empirical data to support regional management, benchmarking, and research on improving efficiency and developing technologies for water and wastewater management systems. The costs and energy required for the supply, treatment, and distribution of water and wastewater lack a standard data collection mechanism and centralized database or storage infrastructure, limiting data-driven decision-making across interdependent infrastructure systems.

42 ENGINEERING↗

Contaminant Source Identification from Finite Sensor Data: Perron–Frobenius Operator and Bayesian Inference

Sensors in the built environment ensure safety and comfort by tracking contaminants in the occupied space. In the event of contaminant release, it is important to use the limited sensor data to rapidly and accurately identify the release location of the contaminant. Identification of the release location will enable subsequent remediation as well as evacuation decision-making. In previous work, we used an operator theoretic approach—based on the Perron–Frobenius (PF) operator—to estimate the contaminant concentration distribution in the domain given a finite amount of streaming sensor data. In the current work, the approach is extended to identify the most probable contaminant release location. The release location identification is framed as a Bayesian inference problem. The Bayesian inference approach requires considering multiple release location scenarios, which is done efficiently using the discrete PF operator. The discrete PF operator provides a fast, effective and accurate model for contaminant transport modeling. The utility of our PF-based Bayesian inference methodology is illustrated using single-point release scenarios in both two and three-dimensional cases. The method provides a fast, accurate, and efficient framework for real-time identification of contaminant source location.

42 ENGINEERING↗

Neural network for processing both spatial and temporal data with time based back-propagation

Neural networks are computing systems modeled after the paradigm of the biological brain. For years, researchers using various forms of neural networks have attempted to model the brain's information processing and decision-making capabilities. Neural network algorithms have impressively demonstrated the capability of modeling spatial information. On the other hand, the application of parallel distributed models to the processing of temporal data has been severely restricted. The invention introduces a novel technique which adds the dimension of time to the well known back-propagation neural network algorithm. In the space-time neural network disclosed herein, the synaptic weights between two artificial neurons (processing elements) are replaced with an adaptable-adjustable filter. Instead of a single synaptic weight, the invention provides a plurality of weights representing not only association, but also temporal dependencies. In this case, the synaptic weights are the coefficients to the adaptable digital filters. Novelty is believed to lie in the disclosure of a processing element and a network of the processing elements which are capable of processing temporal as well as spacial data.

Villarreal, James A.↗

Biomimetic Models for An Ecological Approach to Massively-Deployed Sensor Networks

Promises of ubiquitous control of the physical environment by massively-deployed wireless sensor networks open avenues for new applications that will redefine the way we live and work. Due to small size and low cost of sensor devices, visionaries promise systems enabled by deployment of massive numbers of sensors ubiquitous throughout our environment working in concert. Recent research has concentrated on developing techniques for performing relatively simple tasks with minimal energy expense, assuming some form of centralized control. Unfortunately, centralized control is not conducive to parallel activities and does not scale to massive size networks. Execution of simple tasks in sparse networks will not lead to the sophisticated applications predicted. We propose a new way of looking at massively-deployed sensor networks, motivated by lessons learned from the way biological ecosystems are organized. We demonstrate that in such a model, fully distributed data aggregation can be performed in a scalable fashion in massively deployed sensor networks, where motes operate on local information, making local decisions that are aggregated across the network to achieve globally-meaningful effects. We show that such architectures may be used to facilitate communication and synchronization in a fault-tolerant manner, while balancing workload and required energy expenditure throughout the network.

Jones, Kennie H.↗

Mitigating the Impacts of Uncertain Geomagnetic Disturbances on Electric Grids: A Distributionally Robust Optimization Approach

Severe geomagnetic disturbances (GMDs) increase the magnitude of the electric field on the Earth’s surface (E-field) and drive geomagnetically-induced currents (GICs) along the transmission lines in electric grids. These additional currents can pose severe risks, such as current distortions, transformer saturation and increased reactive power losses, each of which can lead to system unreliability. Today several mitigation actions (e.g., changing grid topology) exist that can reduce the harmful GIC effects on the grids. Making such decisions can be challenging, however, because the magnitude and direction of the E-field are uncertain and non-stationary. In this paper, we model uncertain E-fields using the distributionally robust optimization (DRO) approach that determines optimal transmission grid operations such that the worst-case expectation of the system cost is minimized. We also capture the effect of GICs on the nonlinear AC power flow equations. For solution approaches, we develop an accelerated column-and-constraint generation (CCG) algorithm by exploiting a special structure of the support set of uncertain parameters representing the E-field. Extensive numerical experiments based on “epri-21” and “uiuc-150” systems, designed for GMD studies, demonstrate (i) the computational performance of the accelerated CCG algorithm, (ii) the superior performance of distributionally robust grid operations that satisfy nonlinear, nonconvex AC power flow equations and GIC constraints, in comparison with standard stochastic programming-based methods during the out-of-sample testing.

42 ENGINEERING↗

Initial Systems-Level Assessment of a Distributed Direct Air Capture System Concept at the Urban-scale (UrbanDAC)

Direct Air Capture (DAC) systems offer a promising solution for mitigating global carbon emissions by directly removing ambient carbon dioxide (CO 2 ) from the atmosphere. While future DAC facilities are typically envisioned as being large and centralized, small-scale systems present an alternative approach with advantages such as adaptability and lower uptake costs. By harnessing waste heat from the built environment, such small-scale systems become distributed DAC at the urban scale (UrbanDAC) that benefit from existing urban infrastructure, while presenting challenges such as identifying eligible buildings and sustainable transportation and storage of captured CO 2 . Collaborating with engineering experts and developers of a DAC unit that can be co-located with cooling towers of existing commercial buildings, this study explores the systems-level implications of UrbanDAC using a geographically explicit multi-decision criteria analysis (MCDA) framework. By considering various infrastructure and environmental factors, network analysis and geospatial techniques are applied to identify optimal building candidates for distributed DAC units within Knoxville, Tennessee, USA, as a representative mid-size city. The selected outputs of the MCDA are used to explore a scenario that assumes a CO 2 collection and transport route for 20 high-ranking candidate buildings; total carbon emissions, EV energy consumption, and net carbon dioxide removal (CDR) are then calculated. Results suggest that the spatial variation of optimal candidates between thriving commercial areas is an important planning consideration. Examining the feasibility of UrbanDAC at an urban planning level provides valuable insights into the barriers and enabling conditions for CDR in cities, where the vast majority of CO 2 emissions are produced, and supports decision-making processes for the implementation of decarbonization initiatives. Through this initial assessment, this research acts as a pilot study for an emerging technology that highlights the importance of distributed DAC technologies in addressing climate change and emphasizes the need for further research and exploration in this domain.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗