Search NASA⌕ Search

SEARCH · Search NASA

Results for “dose response model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

The genotype-phenotype landscape of an allosteric protein

Allostery is a fundamental biophysical mechanism that underlies cellular sensing, signaling, and metabolism. Yet a quantitative understanding of allosteric genotype-phenotype relationships remains elusive. Here, we report the large-scale measurement of the genotype-phenotype landscape for an allosteric protein: the lac repressor from Escherichia coli , LacI. Using a method that combines long-read and short-read DNA sequencing, we quantitatively measure the dose-response curves for nearly 10 5 variants of the LacI genetic sensor. The resulting data provide a quantitative map of the effect of amino acid substitutions on LacI allostery and reveal systematic sequence-structure-function relationships. We find that in many cases, allosteric phenotypes can be quantitatively predicted with additive or neural-network models, but unpredictable changes also occur. For example, we were surprised to discover a new band-stop phenotype that challenges conventional models of allostery and that emerges from combinations of nearly silent amino acid substitutions.

59 BASIC BIOLOGICAL SCIENCES↗

Improving Medication Regimen Recommendation for Parkinson’s Disease Using Sensor Technology

Parkinson’s disease medication treatment planning is generally based on subjective data obtained through clinical, physician-patient interactions. The Personal KinetiGraph™ (PKG) and similar wearable sensors have shown promise in enabling objective, continuous remote health monitoring for Parkinson’s patients. In this proof-of-concept study, we propose to use objective sensor data from the PKG and apply machine learning to cluster patients based on levodopa regimens and response. The resulting clusters are then used to enhance treatment planning by providing improved initial treatment estimates to supplement a physician’s initial assessment. We apply k-means clustering to a dataset of within-subject Parkinson’s medication changes—clinically assessed by the MDS-Unified Parkinson’s Disease Rating Scale-III (MDS-UPDRS-III) and the PKG sensor for movement staging. A random forest classification model was then used to predict patients’ cluster allocation based on their respective demographic information, MDS-UPDRS-III scores, and PKG time-series data. Clinically relevant clusters were partitioned by levodopa dose, medication administration frequency, and total levodopa equivalent daily dose—with the PKG providing similar symptomatic assessments to physician MDS-UPDRS-III scores. A random forest classifier trained on demographic information, MDS-UPDRS-III scores, and PKG time-series data was able to accurately classify subjects of the two most demographically similar clusters with an accuracy of 86.9%, an F1 score of 90.7%, and an AUC of 0.871. A model that relied solely on demographic information and PKG time-series data provided the next best performance with an accuracy of 83.8%, an F1 score of 88.5%, and an AUC of 0.831, hence further enabling fully remote assessments. These computational methods demonstrate the feasibility of using sensor-based data to cluster patients based on their medication responses with further potential to assist with medication recommendations.

59 BASIC BIOLOGICAL SCIENCES↗

Biological Response to SPE Exposures

It has long been recognized that a single solar particle event (SPE) can produce, over a short period of time, exposures on the order of LD50 for humans under normal physiological conditions. It is further recognized that recovery from injury over the period of exposure would greatly increase the chances of survival (dose rate effects) although such effects were left unquantified. In the present report we use the bioresponse model derived from a broad range of animal and human exposure data for evaluation of troop readiness in tactical nuclear warfare to evaluate the biological risk posed by the solar event of 4 August 1972. The astronaut blood forming organ (BFO) exposure in deep space would have been 2.2 Sv (1.6 Gy) in a space suit, 1.8 Sv (1.3 Gy) in an aluminum pressure vessel, and 0.7 Sv (0.5 Gy) in an equipment room compared to an X-ray mortality threshold of 1.5 Gy (assuming high dose rate). We find BFO dose rate effectiveness factors for this SPE on the order of 3 to 4, greatly reducing the mortality risks for this event. There is an approximate 3 percent chance that an even larger event may occur for which exposures could be 2-4 times higher. Assured survival of the astronaut requires added shelter shielding and a warning system for this event. The required mass of the shelter shield can be greatly reduced by using hydrogenous materials such as polymers, water, food, and other biological materials in its construction. Limitations of the current bioresponse model arise from the exposures taking place in the microgravity environment wherein the immune system is already challenged and the effective mortality threshold may be reduced by a factor of two. Such microgravity effects could greatly affect astronaut risks.

Wilson, J. W.↗

Lifelong cytomegalovirus and early‐LIFE irradiation synergistically potentiate age‐related defects in response to vaccination and infection

Abstract While whole‐body irradiation (WBI) can induce some hallmarks of immune aging, (re)activation of persistent microbial infection also occurs following WBI and may contribute to immune effects of WBI over the lifespan. To test this hypothesis in a model relevant to human immune aging, we examined separate and joint effects of lifelong latent murine cytomegalovirus (MCMV) and of early‐life WBI over the course of the lifespan. In late life, we then measured the response to a West Nile virus (WNV) live attenuated vaccine, and lethal WNV challenge subsequent to vaccination. We recently published that a single dose of non‐lethal WBI in youth, on its own, was not sufficient to accelerate aging of the murine immune system, despite widespread DNA damage and repopulation stress in hematopoietic cells. However, 4Gy sub‐lethal WBI caused manifest reactivation of MCMV. Following vaccination and challenge with WNV in the old age, MCMV‐infected animals experiencing 4Gy, but not lower, dose of sub‐lethal WBI in youth had reduced survival. By contrast, old irradiated mice lacking MCMV and MCMV‐infected, but not irradiated, mice were both protected to the same high level as the old non‐irradiated, uninfected controls. Analysis of the quality and quantity of anti‐WNV immunity showed that higher mortality in MCMV‐positive WBI mice correlated with increased levels of MCMV‐specific immune activation during WNV challenge. Moreover, we demonstrate that infection, including that by WNV, led to MCMV reactivation. Our data suggest that MCMV reactivation may be an important determinant of increased late‐life mortality following early‐life irradiation and late‐life acute infection.

59 BASIC BIOLOGICAL SCIENCES↗

Utilizing HYSPLIT for Emergency Response Modeling at SRS

At SRS, emergency responders use a variety of tools to detect, track, and mitigate hazardous material releases into the atmosphere. Two models currently used at SRS are Puff-Plume and the Lagrangian Particle Dispersion Model (LPDM), a Gaussian and Lagrangian model, respectively. A decision has been made to replace LPDM with the more widely-supported Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model for evaluating inhalation and ingestion doses following a release. HYSPLIT is designed to compute complex dispersion and deposition simulation To achieve the implementation of HYSPLIT, we have developed a preliminary UI framework that will allow HYSPLIT to be run on ATG computers without the need for active network connections, thus avoiding the loss of capabilities in the event of a network outage during an emergency.

Earley, Ian↗

Vehicle Design Data Format and Process for a Complete TARIS and OLTARIS Radiation Analysis for Designers and Engineers

Protecting astronauts from space radiation is a complex task when it comes to modeling and simulation. This document shows what information is needed from a spacecraft designer using CAD (Computer-Assisted Design) at each phase of the design to enable the engineers to evaluate the design phase against space radiation limits to determine the suitability of the design for space flight. The current personal exposure limits are listed in NASA STD-3001. A proxy to determine the REID (Radiation Exposure Induced Death) in NASA STD-3001 is the whole body effective dose equivalent (E or effective dose). For short-term tissue effects, organ-averaged gray equivalent (G (sub T)) is used. The TARIS (Tool for the Assessment of Radiation In Space - for LaRC (Langley Research Center) engineers) and OLTARIS (On-Line TARIS) - for designers) systems are used to generate these response functions. The E can use ICRP60 or NASA Q-values. A possible space radiation design basis environment for short-term tissue effects is described and used in all analyses. A single space vehicle was designed with three astronaut configurations and two of those configurations were used in a storm shelter thickness perturbation analysis. Conversion of the data from the CAD model to input necessary for TARIS and OLTARIS is also discussed in detail with relevant examples.

Singleterry, Robert C.↗

The effect of track structure on the induction of chromosomal aberrations in murine cells

PURPOSE: To measure chromosome aberrations in C3H 10T1/2 mouse fibroblasts using FISH painting at the first mitosis following exposure to 30 keV/microm hydrogen or neon ions. MATERIALS AND METHODS: Cells in plateau-phase were irradiated with 0.86 MeV protons at the TTT-3 Tandem accelerator in Naples (Italy), or with 400 MeV/n Ne ions at the HIMAC accelerator in Chiba (Japan). Colcemid-blocked cells were harvested at the first mitosis following exposure, and chromosome spreads were hybridized in situ with a fluorescein-labelled composite mouse DNA probe specific for chromosomes 2 and 8. RESULTS: Protons were more efficient than neon ions at the same LET in the induction of chromosome interchanges and breaks. Yields of complex exchanges were similar for both particles at the same dose, but protons produced mostly insertions, while with Ne exposure non-reciprocal exchanges were the most frequent complex-type exchange. CONCLUSIONS: Charged particles with the same LET produce different yields of chromosome aberrations, and some observed differences can be explained based on the available track-structure models.

NASA Center JSC↗

Simulation and Modeling of Time-Resolved X-Ray Detector for the Saturn Accelerator

In this work, we present the technology-aided computer design (TCAD) device simulation and modeling of a silicon p-i-n diode for detecting time-dependent X-ray radiation. We show that the simulated forward and reverse breakdown current–voltage characteristics agree well with the measured data under nonradiation environment by only calibrating carrier lifetimes for the forward bias case and avalanche model critical fields for the reverse bias condition. Using the calibrated parameters and other nominal material properties, we simulated the radiation responses of the p-i-n diode and compared with experimental data when the diode was exposed to X-ray radiation at Sandia’s Saturn facility and the Idaho State University (ISU) TriMeV facility. For Saturn’s Gaussian dose-rate pulses, we show three findings from TCAD simulations. First, the simulated photocurrents are in excellent agreement with the measured data for two dose-rate pulses with peak values of 1.16×10 10 and 1.88×10 10 rad(Si)/s. Second, the simulation results of high dose-rate pulses predict increased delayed photocurrents with longer time tails in the diode electrical responses due to excess carrier generation. Third, simulated peak values of diode radiation responses versus peak dose rates at different bias conditions provide useful guidance to determine the dose-rate range that the p-i-n diode can reliably detect in experiment. For TriMeV’s non-Gaussian dose-rate pulse, our simulated diode response is in decent agreement with the measured data without further calibration. We also studied the effects of device geometry, recombination process, and dose-rate enhancement via TCAD simulations to understand the higher measured response in the time after the peak dose-rate radiation for the p-i-n diode exposed to TriMeV irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chromosome Aberrations in Astronauts

A review of currently available data on in vivo induced chromosome damage in the blood lymphocytes of astronauts proves that, after protracted exposure of a few months or more to space radiation, cytogenetic biodosimetry analyses of blood collected within a week or two of return from space provides a reliable estimate of equivalent radiation dose and risk. Recent studies indicate that biodosimetry estimates from single spaceflights lie within the range expected from physical dosimetry and biophysical models, but very large uncertainties are associated with single individual measurements and the total sample population remains low. Retrospective doses may be more difficult to estimate because of the fairly rapid time-dependent loss of "stable" aberrations in blood lymphocytes. Also, biodosimetry estimates from individuals who participate in multiple missions, or very long (interplanetary) missions, may be complicated by an adaptive response to space radiation and/or changes in lymphocyte survival and repopulation. A discussion of published data is presented and specific issues related to space radiation biodosimetry protocols are discussed.

George, Kerry A.↗

Considering Cell Proliferation to Optimize Detection of Radiation-induced 53BP1+ Foci in 15 Mouse Strains ex vivo

Due to high metabolic activity, proliferating cells continuously generate free radicals, which induce DNA double strand breaks (DSB). Fluorescently tagged nuclear foci of DNA repair protein 53 binding protein-1(53BP1) are used as a standard metric for measuring DSB formation at baseline and in response to environmental insults such as radiation. Here we demonstrate that the background level of spontaneous 53BP1+ foci formation can be modeled mathematically as a function of cell confluence, which is a metric of proliferation rate. This model was validated using spontaneous 53BP1+ foci data from 68 cultures of primary skin fibroblasts derived from 15 different strains of mice, showing a ~10 fold decrease from low to full confluence that is independent of mouse strain. We developed an online open access tool to correct for the impact of cell confluence on the detection of radiation-induced 53BP1+ foci (RIF). This tool provides guidelines for the number of cells required to reach statistical significance for the detection of excess foci induced by low doses of ionizing radiation as a function of confluence and time post-irradiation. We hope that this quantification tool will help the radiation biology community in the design of future experiments that utilize 53BP1+ foci-based quantification of radiation responses in vitro. Our “tool for enhanced results of RIF in cells” (terRIFic) can be found at: https://radbiolab.shinyapps.io/terrific/

Radiation, DNA damage, confluence↗

Non-Ionizing Millimeter Waves Non-Thermal Radiation of Saccharomyces cerevisiae—Insights and Interactions

Non-ionizing millimeter-waves (MMW) interact with cells in a variety of ways. Here the inhibited cell division effect was investigated using 85–105 GHz MMW irradiation within the International Commission on Non-Ionizing Radiation Protection (ICNIRP) non-thermal 20 mW/cm 2 safety standards. Irradiation using a power density of about 1.0 mW/cm 2 SAR over 5–6 h on 50 cells/μL samples of Saccharomyces cerevisiae model organism resulted in 62% growth rate reduction compared to the control (sham). The effect was specific for 85–105 GHz range and was energy- and cell density-dependent. Irradiation of wild type and Δrad52 (DNA damage repair gene) deleted cells presented no differences of colony growth profiles indicating non-thermal MMW treatment does not cause permanent genetic alterations. Dose versus response relations studied using a standard horn antenna (~1.0 mW/cm 2 ) and compared to that of a compact waveguide (17.17 mW/cm 2 ) for increased power delivery resulted in complete termination of cell division via non-thermal processes supported by temperature rise measurements. We have shown that non-thermal MMW radiation has potential for future use in treatment of yeast related diseases and other targeted biomedical outcomes.

59 BASIC BIOLOGICAL SCIENCES↗

Novel Image Processing Interface to Relate DSB Spatial Distribution from Immunofluorescence Foci Experiments to the State-of-the-Art Models of DNA Breakage

A recently developed software (NASARadiationTrackImage) allows a quick and automatic segmentation of foci that indicate spatial localization of specific proteins that are visualized by immunofluorescence. Of interest are the spatial and temporal distribution of foci such as gammaH2AX, a signal of the phosphorylation of a variant of the histone H2A that has been shown to correspond to DSBs, or proteins involved in DSB processing, such as ATM, Rad51, and p53, following exposures of human cells to high charge and energy (HZE) ion irradiation. Experimental data are recorded as sets of two-dimensional images in color with cells and foci of gammaH2AX, ATM, Rad51 or others shown. Different cells, levels of radiation and timing after radiation were recorded. The software allows us to calculate the number of foci per cell, overall intensity of light in foci and their spatial organization. A simple statistical model allows for testing of foci overlap (eclipse). A more complex statistical model previously known as DNAbreak simulates track structure and random chromosome geometry. It has one adjustable parameter corresponding to an average intensity of DSB creation in cubic micrometers of DNA volume per particle track or unit dose. Its limitation is the low-resolution limit both in physical space and DSB's along DNA. It works adequately on the scale of a cell and provides further insights on how the geometry of tracks and DNA affects genomic damage of the cell and subsequent repair. Future developments of the model for the description of the time evolution of DNA damage response proteins, and more robust track structure models will be discussed.

Ponomarev, A. L.↗

Two-stage model of radon-induced malignant lung tumors in rats: effects of cell killing

A two-stage stochastic model of carcinogenesis is used to analyze lung tumor incidence in 3750 rats exposed to varying regimens of radon carried on a constant-concentration uranium ore dust aerosol. New to this analysis is the parameterization of the model such that cell killing by the alpha particles could be included. The model contains parameters characterizing the rate of the first mutation, the net proliferation rate of initiated cells, the ratio of the rates of cell loss (cell killing plus differentiation) and cell division, and the lag time between the appearance of the first malignant cell and the tumor. Data analysis was by standard maximum likelihood estimation techniques. Results indicate that the rate of the first mutation is dependent on radon and consistent with in vitro rates measured experimentally, and that the rate of the second mutation is not dependent on radon. An initial sharp rise in the net proliferation rate of initiated cell was found with increasing exposure rate (denoted model I), which leads to an unrealistically high cell-killing coefficient. A second model (model II) was studied, in which the initial rise was attributed to promotion via a step function, implying that it is due not to radon but to the uranium ore dust. This model resulted in values for the cell-killing coefficient consistent with those found for in vitro cells. An "inverse dose-rate" effect is seen, i.e. an increase in the lifetime probability of tumor with a decrease in exposure rate. This is attributed in large part to promotion of intermediate lesions. Since model II is preferable on biological grounds (it yields a plausible cell-killing coefficient), such as uranium ore dust. This analysis presents evidence that a two-stage model describes the data adequately and generates hypotheses regarding the mechanism of radon-induced carcinogenesis.

NASA Program Radiation Health↗

Space Weather Architecture Options to Support Human and Robotic Deep Space Exploration

Understanding solar energetic particle (SEP) event characteristics is critical to the proper design of human and robotic space missions. This report details a study of operational response time for monitoring space weather for crewed flights, specifically targeting lunar and Mars missions. The NESC assessment team evaluated the required minimum latency for data streams and forecasts that will directly affect mission operations using a 41-year database (i.e., European Space Agency (ESA) Solar Energetic Particle Environment Modeling (SEPEM) RSDv2.0) of SEP events. The database contained 192 SEP events that resulted in a dose increase above background levels. Of those, 10% were “multiple events,” or events that occurred in quick succession. The analysis provides probabilistic values for time to peak flux and dose rate for the duration of each event. This NESC assessment also evaluated the SEP threshold levels for exploration missions to determine the relevant energy range of required proton measurements.

Solar energetic particle↗

The effect of heat treatment on the defect evolution in LPBF 316H stainless steel

This work investigates the effect of processing and heat treatment on defect evolution and irradiation response of laser powder bed fusion (LPBF) 316H stainless steel, with comparisons to LPBF 316L and wrought 316L/316H. Using in-situ and ex-situ ion irradiations across a wide parameter space—temperature (300–675 °C), dose (0.2–25 dpa), dose rate (10 -3 –10 -5 dpa/s), and helium co-implantation (20–2500 appm)—we correlated void swelling, dislocation loop evolution, and segregation behavior with pre-irradiation microstructures (as-built, stress-relieved, solution-annealed, and cold-worked). Results show that swelling is strongly controlled by dislocation density: intermediate densities maximize swelling, while solution annealing or cold working reduce susceptibility to levels comparable to wrought alloys. Low dose rates and helium both promote cavity nucleation and lower the incubation barrier, with helium suppressing the role of dislocation density and driving swelling behavior toward wrought-like response. Loop evolution in SA LPBF 316H resembles wrought 316L but shows localized denuded zones near low-angle grain boundaries. STEM-EDS mapping further revealed Ni segregation at voids and sparse Al-rich oxides, without evidence of Ni–Si precipitates. Collectively, these findings identify dislocation density, helium content, and dose rate as the factors governing swelling in LPBF 316H and provide mechanistic datasets for model validation, supporting LAIN and the qualification of AM austenitic steels for nuclear service.

316 stainless steel↗

Transfer Factors for the FRMAC Assessment Manual and Turbo FRMAC to Improve Radiological Dose Assessment

The Turbo FRMAC analysis tool is used to perform complex calculations to quickly evaluate radiological consequences and aid in decision making during an emergency response by assessing impacts to the public, workers, and the food supply. Turbo FRMAC calculations are based on methods established by the Federal Radiological Monitoring and Assessment Center (FRMAC). To be able to assess impacts, input data called transfer factors that describe radionuclide uptake by local plants and animals are required. During the code application exercises in late 2016, identifying, finding, and validating nonstandard transfer factors proved to be time consuming and diverted the teams’ activity away from other critical tasks. As a result, a task was undertaken to dramatically expand the list of available transfer factors (food and non-food) and incorporate these factors into Turbo FRMAC. This will ultimately result in improved efficiency of the assessment team to perform calculations during times when the FRMAC is activated and provide more defensible, vetted data from which to calculate results. As a result of these and subsequent exercises, transfer factors were needed for the following items: bell peppers, Christmas tree, deer, flowers, fresh cucumbers, tomatoes, grapefruit, lichens, mushrooms, oranges, snap beans, squash, strawberries, sugarcane for sugar and seed, sweet corn, tea, tobacco, tree bark, and watermelon. To expand the applicability of the information tables, generic transfer data were also provided for common categories and recommendations were made for expanding the list of chemicals based on chemical similarity. The data presented in this report were compiled from recent literature with most of the data encompassing the period from 2000 to 2018. The following radionuclides were targeted during the literature search: elements associated with reactor accidents or nuclear detonations (Sr 89/90, Cs 134/137, Ce 141/144, Ru 103/106, I 129/131/133, Pu 238/239, Am 241, Zr 95, and Nb 95) and elements associated with industrial accidents or dirty bombs (Ir 192 and Co 60). Data from other elements were evaluated if they were identified during the literature search. In addition, reports were evaluated that were recommended by the research consultants. For each plant or animal transfer factor, the goal was to determine the geometric mean, the geometric standard deviation, the minimum, the maximum, and the number of measurements used. If only one measurement was available that was presented as the mean. Concentration ratios with large geometric standard deviations (GSDs) were generally the result of a paucity of measurements or a few disparate measurements. Measurement disparity was observed for data from different soil types. The geometric mean (GM) is a good reference value for planning and responses purposes, but the location-specific concentrations are unlikely to be similar to the model results. Recommendations for further work include: segregating the data to reflect the influence of soil type, developing approaches to incorporate animal data based on aggregated transfer measurements, and including data for foliar deposition on plants.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Deterministic Electron, Photon, Proton and Heavy Ion Radiation Transport Suite for the Study of the Jovian System

A deterministic suite of radiation transport codes, developed at NASA Langley Research Center (LaRC), which describe the transport of electrons, photons, protons, and heavy ions in condensed media is used to simulate exposures from spectral distributions typical of electrons, protons and carbon-oxygen-sulfur (C-O-S) trapped heavy ions in the Jovian radiation environment. The particle transport suite consists of a coupled electron and photon deterministic transport algorithm (CEPTRN) and a coupled light particle and heavy ion deterministic transport algorithm (HZETRN). The primary purpose for the development of the transport suite is to provide a means for the spacecraft design community to rapidly perform numerous repetitive calculations essential for electron, proton and heavy ion radiation exposure assessments in complex space structures. In this paper, the radiation environment of the Galilean satellite Europa is used as a representative boundary condition to show the capabilities of the transport suite. While the transport suite can directly access the output electron spectra of the Jovian environment as generated by the Jet Propulsion Laboratory (JPL) Galileo Interim Radiation Electron (GIRE) model of 2003; for the sake of relevance to the upcoming Europa Jupiter System Mission (EJSM), the 105 days at Europa mission fluence energy spectra provided by JPL is used to produce the corresponding dose-depth curve in silicon behind an aluminum shield of 100 mils ( 0.7 g/sq cm). The transport suite can also accept ray-traced thickness files from a computer-aided design (CAD) package and calculate the total ionizing dose (TID) at a specific target point. In that regard, using a low-fidelity CAD model of the Galileo probe, the transport suite was verified by comparing with Monte Carlo (MC) simulations for orbits JOI--J35 of the Galileo extended mission (1996-2001). For the upcoming EJSM mission with a potential launch date of 2020, the transport suite is used to compute the traditional aluminum-silicon dose-depth calculation as a standard shield-target combination output, as well as the shielding response of high charge (Z) shields such as tantalum (Ta). Finally, a shield optimization algorithm is used to guide the instrument designer with the choice of graded-Z shield analysis.

Norman, Ryan B.↗

Simulation of proton-induced energy deposition in integrated circuits

A time-efficient simulation technique was developed for modeling the energy deposition by incident protons in modern integrated circuits. To avoid the excessive computer time required by many proton-effects simulators, a stochastic method was chosen to model the various physical effects responsible for energy deposition by incident protons. Using probability density functions to describe the nuclear reactions responsible for most proton-induced memory upsets, the simulator determines the probability of a proton hit depositing the energy necessary for circuit destabilization. This factor is combined with various circuit parameters to determine the expected error-rate in a given proton environment. An analysis of transient or dose-rate effects is also performed. A comparison to experimental energy-disposition data proves the simulator to be quite accurate for predicting the expected number of events in certain integrated circuits.

Fernald, Kenneth W.↗