At least 307 records · Page 17

ECAR-6330 Rev 0 Computational Fluid Dynamics Evaluation of Core Pressure Drop for the Primary Coolant Apparatus Test

PCAT is a thermal-hydraulic test loop for MARVEL reactor. The design gap thickness between the heater rods of PCAT core is 1.0 mm. The heater elements were manufactured within a straightness tolerance for the designed gap thickness, but several elements have been distorted out of tolerance during the welding process. The distortion of heater rods could lead to flow maldistribution and excessive hotspot temperature when the gap between two heater rods is too narrow. Wire-wraps are the spacer devices widely used in the sodium cooled fast reactor system to maintain the design fuel pitch. Generally, a wire spacer can enhance the turbulent heat transfer, but it increases the pressure drop, which is not desirable for a natural-circulation system like PCAT. Therefore, three short wire-wrap spacers per heater have been proposed to contain the core pressure drops and keep the heater-to-heater gap in an acceptable range. The objectives of this ECAR is to evaluate the PCAR core pressure drop with short wire spacers to confirm that the additional pressure drop due to the wire spacer will not disturb the natural circulation of the PCAT.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Surface-Controlled Drop Oscillations in Space

Large liquid drops were deformed by an acoustic standing wave in a resonant air chanber called the Drop Physics Module, which was carried on Space Shuttle Columbia as part of the second United States Microgravity Laboratory mission. When this deforming force was suddenly reduced, the drops executed free oscillations about a perfect sherical equilibrium. Results are presented for pure water and aqueous solutions of soluble surfactants. [PACS: 43.25.U, 47.55Dz, 68.10.Cr, 83.10.-y].

microgravity drop oscillations drop physics module↗

Fitting the strong coupling constant with soft-drop thrust

Soft drop has been shown to reduce hadronisation effects at $e^+e^-$ colliders for the thrust event shape. In this context, we perform fits of the strong coupling constant for the soft-drop thrust distribution at NLO+NLL accuracy to pseudo data generated by the Sherpa event generator. In particular, we focus on the impact of hadronisation corrections, which we estimate both with an analytical model and a Monte-Carlo based one, on the fitted value of $\alpha_s(m_Z)$. We find that grooming can reduce the size of the shift in the fitted value of $\alpha_s$ due to hadronisation. In addition, we also explore the possibility of extending the fitting range down to significantly lower values of (one minus) thrust. Here, soft drop is shown to play a crucial role, allowing us to maintain good fit qualities and stable values of the fitted strong coupling. The results of these studies show that soft-drop thrust is a promising candidate for fitting $\alpha_s$ at $e^+ e^-$ colliders with reduced impact of hadronisation effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Origin and dynamics of vortex rings in drop splashing

A vortex is a flow phenomenon that is very commonly observed in nature. More than a century, a vortex ring that forms during drop splashing has caught the attention of many scientists due to its importance in understanding fluid mixing and mass transport processes. However, the origin of the vortices and their dynamics remain unclear, mostly due to the lack of appropriate visualization methods. Here, with ultrafast X-ray phase-contrast imaging, we show that the formation of vortex rings originates from the energy transfer by capillary waves generated at the moment of the drop impact. Interestingly, we find a row of vortex rings along the drop wall, as demonstrated by a phase diagram established here, with different power-law dependencies of the angular velocities on the Reynolds number. These results provide important insight that allows understanding and modelling any type of vortex rings in nature, beyond just vortex rings during drop splashing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measuring Liquid Drop Properties on Nanoscale 1D Patterned Photoresist Structures

This communication reports liquid wetting properties of DI-water on one-dimensional nano-patterned photoresist lines atop a silicon substrate as the pattern period is varied from 0.3- to 1.0-µm. Both constant photoresist height and constant width/height ratios are investigated. The line/period ratio was fixed at 0.3 (0.4) for different measurement sequences. The surface of the photoresist was treated with a short CHF 3 reactive ion etch to ensure consistent hydrophobic photoresist: water surface energies. Average parallel contact angle (θ || ), average perpendicular contact angle (θ ⊥ ), drop width (W), and drop length (L) at constant volume were measured on nano-patterned surfaces fabricated with interferometric lithography. Both θ || and θ ⊥ contact angles increase as the period (0.3- to 1-μm) increases; the θ || spreading rate is faster than θ ⊥ due to pinning on the grooves resulting in an elongated drop shape. The traditional Wenzel and Cassie-Baxter models of drop contact angles were developed for isotropic random 2D roughness and do not account for the anisotropy induced by the 1D line patterns. The observed angular variations with period are not consistent with either model. Understanding liquid wetting properties and hydrophobicity on 1D silicon surfaces has many applications in lab-on-a-chip, micro/nano-fluidic devices, roll-to-roll nano-imprint fabrication, self-cleaning surfaces, and micro-reactors.

42 ENGINEERING↗

Sudden Lifetime Drop Phenomena and their Effective Cures in PF-ring and PF-AR

In PF-ring and PF-AR, sudden drops in the electron beam lifetime, which are attributed to dust trapping, were frequently observed after extensive renewals of the storage rings. The reduced-lifetime state sometimes lasts for a few hours, and the mitigation of this problem was strongly demanded for stable user operations. Since a major source of dust particles was thought to be a distributed ion pump (DIP), we attempted switching the DIPs off during user operations in both the rings. As a result, occurrence of the lifetime drops was almost completely suppressed during single-bunch mode in PF-ring, while the occurrence frequency was reduced by only 38% in PF-AR. We found that the lifetime drops were sometimes accompanied by a transient increase in the vacuum pressure at some discharge-prone devices. Based on the hypothesis that the harmful dust could be generated by an electric discharge in vacuum, we attempted the conditioning of these devices in PF-AR by storing 25% higher current than usual. By combination of the DIP-OFF operation and the high-current conditioning, the occurrence frequency of the lifetime drops in PF-AR was reduced by no less than 67%.

43 PARTICLE ACCELERATORS↗

Pre-sheath density drop induced by ion-neutral friction along plasma blobs and implications for blob velocities

The pre-sheath density drop along the magnetic field in field-aligned, radially propagating plasma blobs is investigated in the TORPEX toroidal experiment [Fasoli et al., Plasma Phys. Controlled Fusion 52, 124020 (2010)]. Using Langmuir probes precisely aligned along the magnetic field, we measure the density n{sub se} at a poloidal limiter, where blobs are connected, and the upstream density n{sub 0} at a location half way to the other end of the blobs. The pre-sheath density drop n{sub se}/n{sub 0} is then computed and its dependence upon the neutral background gas pressure is studied. At low neutral gas pressures, the pre-sheath density drop is ≈0.4, close to the value of 0.5 expected in the collisionless case. In qualitative agreement with a simple model, this value decreases with increasing gas pressure. No significant dependence of the density drop upon the radial distance into the limiter shadow is observed. The effect of reduced blob density near the limiter on the blob radial velocity is measured and compared with predictions from a blob speed-versus-size scaling law [Theiler et al., Phys. Rev. Lett. 103, 065001 (2009)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fungal drops: a novel approach for macro- and microscopic analyses of fungal mycelial growth

Abstract This study presents an inexpensive approach for the macro- and microscopic observation of fungal mycelial growth. The ‘fungal drops’ method allows to investigate the development of a mycelial network in filamentous microorganisms at the colony and hyphal scales. A heterogeneous environment is created by depositing 15–20 µl drops on a hydrophobic surface at a fixed distance. This system is akin to a two-dimensional (2D) soil-like structure in which aqueous-pockets are intermixed with air-filled pores. The fungus (spores or mycelia) is inoculated into one of the drops, from which hyphal growth and exploration take place. Hyphal structures are assessed at different scales using stereoscopic and microscopic imaging. The former allows to evaluate the local response of regions within the colony (modular behaviour), while the latter can be used for fractal dimension analyses to describe the hyphal network architecture. The method was tested with several species to underpin the transferability to multiple species. In addition, two sets of experiments were carried out to demonstrate its use in fungal biology. First, mycelial reorganization of Fusarium oxysporum was assessed as a response to patches containing different nutrient concentrations. Second, the effect of interactions with the soil bacterium Pseudomonas putida on habitat colonization by the same fungus was assessed. This method appeared as fast and accessible, allowed for a high level of replication, and complements more complex experimental platforms. Coupled with image analysis, the fungal drops method provides new insights into the study of fungal modularity both macroscopically and at a single-hypha level.

Buffi, Matteo↗

Dropping cold quantum gases on Earth over long times and large distances

We analyze the evolution of a degenerate quantum gas (bosons and fermions) falling in Earth's gravity during long times (10 s) and over large distances (100 m). This models an experiment that is currently performed by the QUANTUS Collaboration at ZARM drop tower in Bremen, Germany. Starting from the classical mechanics of the drop capsule and a single particle trapped within, we develop a quantum field theoretical description for this experimental situation in an inertial frame, the corotating frame of the Earth, as well as the comoving frame of the drop capsule. Suitable transformations eliminate noninertial forces, provided all external potentials (trap, gravity) can be approximated with a second-order Taylor expansion around the instantaneous trap center. This is an excellent assumption, and the harmonic potential theorem applies. As a first application, we study the quantum dynamics of a cigar-shaped Bose-Einstein condensate in the Gross-Pitaevskii mean-field approximation. Due to the instantaneous transformation to the rest frame of the superfluid wave packet, the long-distance drop can be studied easily on a numerical grid.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transient dynamics in drop impact on a superheated surface

When a drop impinges on a superheated surface, a Leidenfrost vapor layer forms between the drop and the surface. Transient dynamics of the layer can play a critical role for cooling in power plants but is not fully understood. Here we successfully visualize transient dynamics of the layer using ultrafast X-ray imaging. We reveal that a vapor disk with a homogeneous thickness, developed during drop impact, grows in thickness following the Fourier law. At a certain thickness (12 ± 2 μm in this study) of the vapor disk, ripples generate at its periphery due to capillary waves, resulting in significant enhancement of drop vaporization.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The stopped-drop method: a novel setup for containment-free and time-resolved measurements

A novel setup for containment-free time-resolved experiments at a free-hanging drop is reported. Within a dead-time of 100 ms a drop of mixed reactant solutions is formed and the time evolution of a reaction can be followed from thereon by various techniques. As an example, a small-angle X-ray scattering study on the formation mechanism of EDTA-stabilized CdS both at a synchrotron and a laboratory X-ray source is presented here. While the evolution can be followed with one drop only at a synchrotron source, a stroboscopic mode with many drops is preferable for the laboratory source.

containment-free↗

Experimental verification of gain drop due to general ion recombination for a carbon-ion pencil beam

Purpose: Accurate dose measurement in radiotherapy is critically dependent on correction for gain drop, which is the difference of the measured current from the ideal saturation current due to general ion recombination. Although a correction method based on the Boag theory has been employed, the theory assumes that ionized charge density in an ionization chamber (IC) is spatially uniform throughout the irradiation volume. For particle pencil beam scanning, however, the charge density is not uniform, because the fluence distribution of a pencil beam is not uniform. The aim of this study was to verify the effect of the nonuniformity of ionized charge density on the gain drop due to general ion recombination. Methods: The authors measured the saturation curve, namely, the applied voltage versus measured current, using a large plane-parallel IC and 24-channel parallel-plate IC with concentric electrodes. To verify the effect of the nonuniform ionized charge density on the measured saturation curve, the authors calculated the saturation curve using a method which takes into account the nonuniform ionized charge density and compared it with the measured saturation curves. Results: Measurement values of the different saturation curves in the different channels of the concentric electrodes differed and were consistent with the calculated values. The saturation curves measured by the large plane-parallel IC were also consistent with the calculation results, including the estimation error of beam size and of setup misalignment. Although the impact of the nonuniform ionized charge density on the gain drop was clinically negligible with the conventional beam intensity, it was expected that the impact would increase with higher ionized charge density. Conclusions: For pencil beam scanning, the assumption of the conventional Boag theory is not valid. Furthermore, the nonuniform ionized charge density affects the prediction accuracy of gain drop when the ionized charge density is increased by a higher dose rate and/or lower beam size.

61 RADIATION PROTECTION AND DOSIMETRY↗

Testing Dynamic Earthquake Rupture Models Generated With Stochastic Stress Drop

In this study we investigate the performance of rupture dynamics modeling using heterogenous stress for a M6.5 crustal earthquake on a strike slip vertical fault. In our simulations we used heterogenous stress drop models with correlated stochastic perturbations following the work of Pitarka et al. (2009). The stress model with multiscale variability is designed to accommodate high-stress drop asperity areas and small-scale spatial stress variations. The stress drop and size of asperities are estimated following the IM2011 (Irikura and Miyake, 2011) recipe. In our spontaneous rupture modeling we use a linear slip weakening friction law, with depth depend strength excess, dynamic stress drop and slip weakening distance Dc. Our strategy in preparing the model parameters with vertical and lateral variability is in agreement with observations of earthquake rupture that have confirmed the existence of a shallow weak rupture zone consisting of ductile crustal material, located in the upper 4 km of the crust, and brittle seismogenic zone, underlying the weak zone. The primary objective of our study is to develop a procedure for preparing dynamic rupture models with multiscale variability, and validate spontaneous rupture modeling of strike-slip faults by comparing the resulting rupture kinematics and near-fault ground motion with empirical models for this type of rupture.

58 GEOSCIENCES↗

Harnessing the Hydroelectric Potential of Engineered Drops (Final Technical Report)

The potential for low-head hydropower in the engineered drops in both federal and private irrigation system is well known and significant. The environmental and socio/recreational impacts of harnessing this renewable energy resource in man-made conduits are much less, and often insignificant, compared with comparable hydro-electric potential in natural water features on rivers, lakes, and streams. Yet, few new plants have been commissioned in more than two decades. Over the same time period, low head hydro installations in Germany have more than doubled. The challenge is in finding economical ways to harness the hydro-electric potential in the engineered drops, and efficiently deliver the power to the grid. The objectives of Percheron Power, LLC's (Percheron Power) Project were to design, develop, permit, and operate an innovative low-head hydro-electric generation facility on an existing engineered drop of a large irrigation canal system. The hydro-electric generation facility was designed to employ a new type of turbine and technology, called an Archimedes Hydrodynamic Screw (AHS), to harness the existing potential of the engineered drop. The goal was to demonstrate the new lower cost AHS technology system to federal agencies, irrigation districts and other system owners and to support further development of new small hydropower projects at previously marginal low-head sites in the U.S. The objective of this funding opportunity of the Department of Energy Water Power Technologies Office was to reduce the Levelized Cost of Energy (LCOE) for small hydropower to less than ${$}$0.07/kWh (${$}$70/MWh) to be competitive with existing base-load power sources such as coal-powered power plants.

13 HYDRO ENERGY↗

Lifetime extension drop-test of real-world corroded 5 Quart Hagan nuclear material storage container

A 5Qt Hagan container with a 20-year history of nuclear material storage was challenged with three successive drop tests at a height of 3.7 meters. The total mass of the test package was 12.1 kg. The 1st and 2nd drop tests (center of gravity over the container bottom corner but 180 degrees apart on the container bottom face) passed the pre- and post- impact helium leak criterion at less than 1.00E-6 atm-cc/sec (ambient cubic centimeters per second). The 3rd and final test (center of gravity over top corner) failed with a post-impact gross leak of 1.1E-1 atmcc/sec. The RRFMC (Respirable Release Fraction Measurement Chamber) is a drop tower test system that is critical for the sustainability of the SAVY-4000™ series and Hagan-type (NFT Inc. Golden CO) nuclear material storage containers. These are the primary in-use nuclear material storage container types at the Los Alamos National Laboratory TA-55 facility. Results are presented to expand the technical knowledge basis for container lifetime, regarding actual exposure to corrosive gas species on the container inner surfaces. The primary source of general corrosion throughout the container is gaseous hydrogen chloride (HCl). This gas is generated by the degradation of the polyvinylchloride (PVC) bag-out bag. Additionally, in most cases, the nuclear material itself also releases HCl gas (due to residual chemical components associated with the material formation). The RRFMC drop tower gives the end-user the ability record and analyze high-speed video and photography and if needed aerosol mass release measurements. In this report the principal issue is the physical deformation of the 5Qt Hagan container. There were no mass release experiments of test aerosol mass in the present study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rapid Spaceborne Mapping of Wildfire Retardant Drops for Active Wildfire Management

Aerial application of fire retardant is a critical tool for managing wildland fire spread. Retardant applications are carefully planned to maximize fire line effectiveness, improve firefighter safety, protect high-value resources and assets, and limit environmental impact. However, topography, wind, visibility, and aircraft orientation can lead to differences between planned drop locations and the actual placement of the retardant. Information on the precise placement and areal extent of the dropped retardant can provide wildland fire managers with key information to (1) adaptively manage event resources, (2) assess the effectiveness of retardant slowing or stopping fire spread, (3) document location in relation to ecologically sensitive areas; and perform or validate cost-accounting for drop services. This study uses Sentinel-2 satellite data and commonly used machine learning classifiers to test an automated approach for detecting and mapping retardant application. We show that a multiclass model (retardant, burned, unburned, and cloud artifact classes) outperforms a single-class retardant model and that image differencing (post-application minus pre-application) outperforms single-image models. Compared to the random forest and support vector machine, the gradient boosting model performed the best with an overall accuracy of 0.88 and an F1 Score of 0.76 for fire retardant, though results were comparable for all three models. Our approach maps the full areal extent of the dropped retardant within minutes of image availability, rather than linear representations currently mapped by aerial GPS surveys. The development of this capability allows for the rapid assessment of retardant effectiveness and documentation of placement in relation to sensitive environments.

54 ENVIRONMENTAL SCIENCES↗

Ignition of partially shattered liquid fuel drops in a reflected shock wave environment

An experimental investigation of the ignition of individual fuel drops after their interaction with an incident and a reflected shock wave near the end wall of a shock tube has been carried out. The influence of the aerodynamic shattering of the fuel drop by the convective flow on the ignition characteristics has been examined by varying the drop-end wall separation distance. Data are presented which show the ignition delay times to be a function of the various experimental conditions encountered in this study. A comparison is made with previous investigations concerning the ignition of a liquid fuel drop due only to the interaction with an incident shock wave.

Wierzba, A. S.↗

The lift force on a drop in unbounded plane Poiseuille flow

The lift force on a deformable liquid sphere moving in steady, plane Poiseuille-Stokes flow and subjected to an external body force is calculated. The results are obtained by seeking a solution to Stokes' equations for the motion of the liquids inside and outside the slightly perturbed sphere surface, as expansions valid for small values of the ratio of the Weber number to the Reynolds number. When the ratio of the drop and external fluid viscosities is small, the lift exerted on a neutrally buoyant drop is found to be approximately one-tenth of the magnitude of the force reported by Wohl and Rubinow acting on the same drop in unbounded Poiseuille flow in a tube. The resultant trajectory of the drop is calculated and displayed as a function of the external body force.

Wohl, P. R.↗