Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Perspective: Nonequilibrium dynamics of localized and delocalized excitons in colloidal quantum dot solids

Self-assembled quantum dot (QD) solids are a highly tunable class of materials with a wide range of applications in solid-state electronics and optoelectronic devices. In this perspective, the authors highlight how the presence of microscopic disorder in these materials can influence their macroscopic optoelectronic properties. Specifically, they consider the dynamics of excitons in energetically disordered QD solids using a theoretical model framework for both localized and delocalized excitonic regimes. In both cases, they emphasize the tendency of energetic disorder to promote nonequilibrium relaxation dynamics and discuss how the signatures of these nonequilibrium effects manifest in time-dependent spectral measurements. Moreover, they describe the connection between the microscopic dynamics of excitons within the material and the measurement of material specific parameters, such as emission linewidth broadening and energetic dissipation rate.

solar (photovoltaic), solid state lighting, photos↗

Development of a dynamic flow imaging phantom for dynamic contrast-enhanced CT

Purpose: Dynamic contrast enhanced CT (DCE-CT) studies with modeling of blood flow and tissue perfusion are becoming more prevalent in the clinic, with advances in wide volume CT scanners allowing the imaging of an entire organ with sub-second image frequency and sub-millimeter accuracy. Wide-spread implementation of perfusion DCE-CT, however, is pending fundamental validation of the quantitative parameters that result from dynamic contrast imaging and perfusion modeling. Therefore, the goal of this work was to design and construct a novel dynamic flow imaging phantom capable of producing typical clinical time-attenuation curves (TACs) with the purpose of developing a framework for the quantification and validation of DCE-CT measurements and kinetic modeling under realistic flow conditions. Methods: The phantom is based on a simple two-compartment model and was printed using a 3D printer. Initial analysis of the phantom involved simple flow measurements and progressed to DCE-CT experiments in order to test the phantoms range and reproducibility. The phantom was then utilized to generate realistic input TACs. A phantom prediction model was developed to compute the input and output TACs based on a given set of five experimental (control) parameters: pump flow rate, injection pump flow rate, injection contrast concentration, and both control valve positions. The prediction model is then inversely applied to determine the control parameters necessary to generate a set of desired input and output TACs. A protocol was developed and performed using the phantom to investigate image noise, partial volume effects and CT number accuracy under realistic flow conditionsResults: This phantom and its surrounding flow system are capable of creating a wide range of physiologically relevant TACs, which are reproducible with minimal error between experiments ({sigma}/{mu} < 5% for all metrics investigated). The dynamic flow phantom was capable of producing input and output TACs using either step function based or typical clinical arterial input function (AIF) inputs. The measured TACs were in excellent agreement with predictions across all comparison metrics with goodness of fit (R{sup 2}) for the input function between 0.95 and 0.98, while the maximum enhancement differed by no more than 3.3%. The predicted output functions were similarly accurate producing R{sup 2} values between 0.92 and 0.99 and maximum enhancement to within 9.0%. The effect of ROI size on the arterial input function (AIF) was investigated in order to determine an operating range of ROI sizes which were minimally affected by noise for small dimensions and partial volume effects for large dimensions. It was possible to establish the measurement sensitivity of both the Toshiba (ROI radius range from 1.5 to 3.2 mm ''low dose'', 1.4 to 3.0 mm ''high dose'') and GE scanner (1.5 to 2.6 mm ''low dose'', 1.1 to 3.4 mm ''high dose''). This application of the phantom also provides the ability to evaluate the effect of the AIF error on kinetic model parameter predictions. Conclusions: The dynamic flow imaging phantom is capable of producing accurate and reproducible results which can be predicted and quantified. This results in a unique tool for perfusion DCE-CT validation under realistic flow conditions which can be applied not only to compare different CT scanners and imaging protocols but also to provide a ground truth across multimodality dynamic imaging given its MRI and PET compatibility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The potential of positron emission tomography for intratreatment dynamic lung tumor tracking: A phantom study

Purpose: This study aims to evaluate the potential and feasibility of positron emission tomography for dynamic lung tumor tracking during radiation treatment. The authors propose a center of mass (CoM) tumor tracking algorithm using gated-PET images combined with a respiratory monitor and investigate the geometric accuracy of the proposed algorithm. Methods: The proposed PET dynamic lung tumor tracking algorithm estimated the target position information through the CoM of the segmented target volume on gated PET images reconstructed from accumulated coincidence events. The information was continuously updated throughout a scan based on the assumption that real-time processing was supported (actual processing time at each frame ≈10 s). External respiratory motion and list-mode PET data were acquired from a phantom programmed to move with measured respiratory traces (external respiratory motion and internal target motion) from human subjects, for which the ground truth target position was known as a function of time. The phantom was cylindrical with six hollow sphere targets (10, 13, 17, 22, 28, and 37 mm in diameter). The measured respiratory traces consisted of two sets: (1) 1D-measured motion from ten healthy volunteers and (2) 3D-measured motion from four lung cancer patients. The authors evaluated the geometric accuracy of the proposed algorithm by quantifying estimation errors (Euclidean distance) between the actual motion of targets (1D-motion and 3D-motion traces) and CoM trajectories estimated by the proposed algorithm as a function of time. Results: The time-averaged error of 1D-motion traces over all trajectories of all targets was 1.6 mm. The error trajectories decreased with time as coincidence events were accumulated. The overall error trajectory of 1D-motion traces converged to within 2 mm in approximately 90 s. As expected, more accurate results were obtained for larger targets. For example, for the 37 mm target, the average error over all 1D-motion traces was 1.1 mm; and for the 10 mm target, the average error over all 1D-motion traces was 2.8 mm. The overall time-averaged error of 3D-motion traces was 1.6 mm, which was comparable to that of the 1D-motion traces. There were small variations in the errors between the 3D-motion traces, although the motion trajectories were very different. The accuracy of the estimates was consistent for all targets except for the smallest. Conclusions: The authors developed an algorithm for dynamic lung tumor tracking using list-mode PET data and a respiratory motion signal, and demonstrated proof-of-principle for PET-guided lung tumor tracking. The overall tracking error in phantom studies is less than 2 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Controlling quantum many-body dynamics in driven Rydberg atom arrays

Dynamic stabilization of an array Large-scale systems comprising one-dimensional chains and two-dimensional arrays of excited atoms held in a programmable optical lattice are a powerful platform with which to simulate emergent phenomena. Bluvstein et al. built an array of up to 200 Rydberg atoms and subjected the system to periodic excitation. Under such driven excitation, they found that the array of atoms stabilized, freezing periodically into what looked like time crystals. Understanding and controlling the dynamic interactions in quantum many-body systems lies at the heart of contemporary condensed matter physics and the exotic phenomena that can occur. Science , this issue p. 1355

Science & Technology - Other Topics↗

Earth System Model Simulations of Ameriflux sites using dynamic roots and dynamic leaf to root allocation

This data package contains point-scale Earth System Model simulations run with DOE's E3SM Model. The package includes four sets of simulations, one set of simulations run in the default configuration, a second set of simulations run with the dynamic root module enabled, the third set with dynamic leaf to fine root allocation, and the fourth with the combination of dynamic roots and dynamic allocation. These simulations were run in point mode a Ameriflux sites, US-MMS, US-Moz, US-Syv, and US-NR1. These datasets can be used to assess the impact that dynamic roots have on Land Surface fluxes such as carbon and water. The simulations were run with atmospheric forcing from the Global Soil Wetness Project. We provide specifically here Gross Primary Production, Transpiration, relative root fraction per soil layer as well as Air Temperature, Precipitation and all the parameterizations used for the simulations. Our purpose for generating and analyzing these simulations was to assess the role that root dynamics and foraging for water has in the recovery timescale of ecosystems following climate perturbation. All data provided are in the "netcdf" format using standard CF-1 (Climate and Forecast) Convention. The data are all machine readable using various software platforms including Matlab, NCO, Panoply and R.

54 ENVIRONMENTAL SCIENCES↗

The effects of space charge on the dynamics of the booster synchrotron in the Jefferson Lab EIC

Optimization of the booster synchrotron design to operate in the extreme space-charge dominated regime is proposed. This study is motivated by the ultra-high luminosity promised by the JLEIC accelerator complex, which poses several beam dynamics and lattice design challenges for its individual components. We examine the effects of space charge on the dynamics of the booster synchrotron for the proposed JLEIC electron ion collider. This booster will inject and accumulate protons and heavy ions at an energy of 285 MeV and then engage in a process of acceleration and electron cooling to bring it to its extraction energy of 7 GeV. This would then be sent into the ion collider ring part of JLEIC. In order to examine the effects of space charge on the dynamics of this process we use the software SYNERGIA. We model both the initial coasting beam as well as proposed acceleration bunch properties to evaluate the best methods of creating the JLEIC beam.

Nissen, Edith↗

Special Issue: Microbial Community Modeling: Prediction of Microbial Interactions and Community Dynamics

Microbial communities are networks of species, the interaction structure of which dynamically reorganizes in a varying environment. Even in a static condition, community dynamics are often difficult to predict due to highly nonlinear interspecies interactions. Understanding fundamental principles of microbial interactions is therefore key for predicting and harnessing community function and properties. As extensively reviewed previously, mathematical models and computational methods that can predictively link interactions to community behaviors are indispensable tools for achieving this goal. This Special Issue of Processes collects eleven papers from lead scientists and researchers active in the area under the topic of “Microbial Community Modeling: Prediction of Microbial Interactions and Community Dynamics.” The collected papers cover various topics of interest: 1) two review/opinion papers discussing recent advances in biofilm modeling and specific issues for successful collaboration between experimentalists and theorists, 2) one paper on the dynamics of complex environmental communities, 3) six papers dealing with fundamental aspects of microbial interactions and stability in model communities, and 4) two papers on the development and utilization of microbial consortia for biotechnology applications.

Song, Hyun-Seob (ORCID:0000000221546358)↗

Dynamical Classification of Trans-Neptunian Objects Detected by the Dark Energy Survey

The outer solar system contains a large number of small bodies (known as trans-Neptunian objects or TNOs) that exhibit diverse types of dynamical behavior. The classification of bodies in this distant region into dynamical classes—subpopulations that experience similar orbital evolution—aids in our understanding of the structure and formation of the solar system. In this work, we propose an updated dynamical classification scheme for the outer solar system. This approach includes the construction of a new (automated) method for identifying mean motion resonances. We apply this algorithm to the current data set of TNOs observed by the Dark Energy Survey (DES) and present a working classification for all of the DES TNOs detected to date. Our classification scheme yields 1 inner centaur, 19 outer centaurs, 21 scattering disk objects, 47 detached TNOs, 48 securely resonant objects, 7 resonant candidates, and 97 classical belt objects. Among the scattering and detached objects, we detect 8 TNOs with semimajor axes greater than 150 au.

79 ASTRONOMY AND ASTROPHYSICS↗

Portable dynamic pressure generator for static and dynamic calibration of in situ pressure transducers

A portable dynamic pressure generator was developed to meet the requirements of determining the dynamic sensitivities of in situ pressure transducers at low frequencies. The device is designed to operate in a frequency range of 0 to 100 Hz, although it was only tested up to 30 Hz, and to generate dynamic pressures up to 13.8 kPa (2 psi). A description of the operating characteristics and instrumentation used for pressure, frequency, and displacement measurements is given. The pressure generator was used to statically and dynamically calibrate transducers. Test results demonstrated that a difference an exist between the static and dynamic sensitivity of a transducer, confirming the need for dynamic calibrations of in situ pressure transducers.

Bolt, P. A.↗

Flight-vehicle materials, structures, and dynamics - Assessment and future directions. Vol. 5 - Structural dynamics and aeroelasticity

Various papers on flight vehicle materials, structures, and dynamics are presented. Individual topics addressed include: general modeling methods, component modeling techniques, time-domain computational techniques, dynamics of articulated structures, structural dynamics in rotating systems, structural dynamics in rotorcraft, damping in structures, structural acoustics, structural design for control, structural modeling for control, control strategies for structures, system identification, overall assessment of needs and benefits in structural dynamics and controlled structures. Also discussed are: experimental aeroelasticity in wind tunnels, aeroservoelasticity, nonlinear aeroelasticity, aeroelasticity problems in turbomachines, rotary-wing aeroelasticity with application to VTOL vehicles, computational aeroelasticity, structural dynamic testing and instrumentation.

Noor, Ahmed K.↗

The Influence of Dynamic Contact Angle on Wetting Dynamics

When surface tension forces dominate, and regardless of whether the situation is static or dynamic, the contact angle (the angle the interface between two immiscible fluids makes when it contacts a solid) is the key parameter that determines the shape of a fluid-fluid interface. The static contact angle is easy to measure and implement in models predicting static capillary surface shapes and such associated quantities as pressure drops. By contrast, when the interface moves relative to the solid (as in dynamic wetting processes) the dynamic contact angle is not identified unambiguously because it depends on the geometry of the system Consequently, its determination becomes problematic and measurements in one geometry cannot be applied in another for prediction purposes. However, knowing how to measure and use the dynamic contact angle is crucial to determine such dynamics as a microsystem throughput reliably. In this talk we will present experimental and analytical efforts aimed at resolving modeling issues present in dynamic wetting. We will review experiments that show the inadequacy of the usual hydrodynamic model when a fluid-fluid meniscus moves over a solid surface such as the wall of a small tube or duct. We will then present analytical results that show how to parametrize these problems in a predictive manner. We will illustrate these ideas by showing how to implement the method in numerical fluid mechanical calculations.

Rame, Enrique↗

Overview of Dynamic Test Techniques for Flight Dynamics Research at NASA LaRC (Invited)

An overview of dynamic test techniques used at NASA Langley Research Center on scale models to obtain a comprehensive flight dynamics characterization of aerospace vehicles is presented. Dynamic test techniques have been used at Langley Research Center since the 1920s. This paper will provide a partial overview of the current techniques available at Langley Research Center. The paper will discuss the dynamic scaling necessary to address the often hard-to-achieve similitude requirements for these techniques. Dynamic test techniques are categorized as captive, wind tunnel single degree-of-freedom and free-flying, and outside free-flying. The test facilities, technique specifications, data reduction, issues and future work are presented for each technique. The battery of tests conducted using the Blended Wing Body aircraft serves to illustrate how the techniques, when used together, are capable of characterizing the flight dynamics of a vehicle over a large range of critical flight conditions.

Owens, D. Bruce↗

Slosh-Induced Ullage Collapse Validation by Computational Fluid Dynamics and Application to In-space Propellant Dynamics

Ullage collapse predictions made using Computational Fluid Dynamics (CFD) were validated then made for an in-space cryogenic propellant unsettling application. Ullage collapse is the decrease in propellant tank pressure due to cooling of the ullage gas, which can be significant for cryogenic propulsion systems. Vehicles may be developed that are robust to temperature and pressure changes caused by heat leaks, e.g., propellant tanks with high maximum operation pressures, technologies yielding active thermal conditioning, and systems with ample pressurant for conditioning. These methods are robust because additional mass, cost, and complexity are used to address cryogenic fluid management (CFM). As vehicles are optimized for increased payload capacity, tracking of events such as ullage collapse and self-pressurization in tanks will become increasingly important for propellant inventory calculations. Some ullage collapse events can be studied through ground experimentation, but propellant unsettling in and around in-space coast mission phases must be studied in the absence of an acceleration field. Computational Fluid Dynamics is a powerful tool to address this need, enabling prediction of complex physics prior to flight. Validation of the chosen CFD tool and modeling methodology was done using data from a previously conducted subscale slosh-induced ullage collapse ground test performed in part by the Japan Aerospace Exploration Agency (JAXA). A small tank was partially filled with liquid nitrogen and pressurized with gaseous nitrogen at various temperatures. The tank was oscillated laterally to induce high amplitude slosh dynamics resulting in wave breakup. Successful qualitative validation of slosh wave dynamics and quantitative validation of ullage collapse promoted confidence in extending ullage collapse predictions to a flight application. Mechanisms of ullage collapse caused by main engine cutoff while in-space were identified. Both slosh dynamics leading to engine shutdown and body dynamics following shutdown were shown to contribute to propellant unsettling and ullage collapse.

J M Brodnick↗

Generating Dynamic System Matrices for Dynamic SPECT

The purpose of the computer program is to generate system matrices that model data acquisition process in dynamic single photon emission computed tomography (SPECT). The application is for the reconstruction of dynamic data from projection measurements that provide the time evolution of activity uptake and wash out in an organ of interest. The measurement of the time activity in the blood and organ tissue provide time-activity curves (TACs) that are used to estimate kinetic parameters. The program provides a correct model of the in vivo spatial and temporal distribution of radioactive in organs. The model accounts for the attenuation of the internal emitting radioactivity, it accounts for the vary point response of the collimators, and correctly models the time variation of the activity in the organs. One important application where the software is being used in a measuring the arterial input function (AIF) in a dynamic SPECT study where the data are acquired from a slow camera rotation. Measurement of the arterial input function (AIF) is essential to deriving quantitative estimates of regional myocardial blood flow using kinetic models. A study was performed to evaluate whether a slowly rotating SPECT system could provide accurate AIF's for myocardial perfusion imaging (MPI). Methods: Dynamic cardiac SPECT was first performed in human subjects at rest using a Phillips Precedence SPECT/CT scanner. Dynamic measurements of Tc-99m-tetrofosmin in the myocardium were obtained using an infusion time of 2 minutes. Blood input, myocardium tissue and liver TACs were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K1. Results: The spatiotemporal 4D ML-EM reconstructions gave more accurate reconstructions that did standard frame-by-frame 3D ML-EM reconstructions. From additional computer simulations and phantom studies, it was determined that a 1 minute infusion with a SPECT system rotation speed providing 180 degrees of projection data every 54s can produce measurements of blood pool and myocardial TACs. This has important application in the circulation of coronary flow reserve using rest/stress dynamic cardiac SPECT. They system matrices are used in maximum likelihood and maximum a posterior formulations in estimation theory where through iterative algorithms (conjugate gradient, expectation maximization, or maximum a posteriori probability algorithms) the solution is determined that maximizes a likelihood or a posteriori probability function.

Source record↗

Application of a kinetic energy partitioning scheme for ab initio molecular dynamics to reactions associated with ionization in water tetramers

We give the details of a partitioning scheme of the kinetic energy in molecular dynamics based on instantaneous internal coordinates and atomic velocities. The scheme applied to the analysis of the short-time dynamics after ionization in ‘cyclic’ and ‘branched’ water tetramers illustrates that the tetrameric systems can be usefully partitioned into two subsystems, a ‘reactive trimer’ and a ‘solvent’ molecule. The partitioned kinetic energy exhibits a broad peak that can be assigned to the interaction between the two sub-systems, and a sharper peak arising from the proton transfer that occurs upon ionization. Comparison of the dynamics in tetramer clusters suggests that the stability of the hydroxyl radical formed upon ionization depends on the instantaneous configuration of the water molecules around the ionized water. These findings are consistent with those reported earlier for the (H2O)17 cluster. This work was supported in part by the Division of Chemical Sciences, Office of Basic Energy Sciences, of the U.S. Department of Energy (DOE). This research was performed in part using the Molecular Science Computing Facility in the William R. Wiley Environmental Molecular Sciences Laboratory (EMSL) at the Pacific Northwest National Laboratory (PNNL). The EMSL is funded by DOE’s Office of Biological and Environmental Research. PNNL is operated by Battelle for DOE.

ab initio molecular dynamics↗

Dynamic piezoresponse force microscopy: Spatially resolved probing of polarization dynamics in time and voltage domains

An approach for probing dynamic phenomena during hysteresis loop measurements in piezoresponse force microscopy (PFM) is developed. Dynamic PFM (D-PFM) necessitates development of 5-dimensional (5D) data acquisition protocols and associated methods for analysis and visualization of multidimensional data. Using a combination of multivariate statistical analysis and phenomenological fitting, we explore dynamic behavior during polarization switching in model ferroelectric films with dense ferroelastic domain structures and in ferroelectric capacitors. In polydomain films, multivariate analysis of the switching data suggests that ferroelectric and ferroelastic components can be decoupled and time dynamics can be explored. In capacitors, a strong correlation between polarization dynamics and microstructure is observed. The future potential of D-PFM for probing time-dependent hysteretic phenomena in ferroelectrics and ionic systems is discussed.

Dynamic piezoresponse force microscopy↗

Dynamic-range studies and improvements for multiplexed photonic Doppler velocimetry

This paper presents studies of the dynamic range achievable with multiplexed photonic Doppler velocimetry (MPDV) measurements, and demonstrates techniques to extend the dynamic range. Improved dynamic range for MPDV measurements is needed in order to track the velocity of the free surface behind a cloud of ejecta. Therefore, the authors have undertaken theoretical and experimental studies of factors affecting dynamic range, particularly in cases where the large number of MPDV probe points precludes high illumination power on each channel. To quantify the potential dynamic range of a given MPDV configuration, they introduce a metric called the frequency-domain number of bits, FNOB, which is less stringent than the formally defined equivalent number of bits (ENOB). This new metric is simple to compute in the lab, and it is well suited to conventional PDV analysis, which does not require digitizer phase coherence beyond tens of nanoseconds.

36 MATERIALS SCIENCE↗