Search NASA⌕ Search

SEARCH · Search NASA

Results for “electric resistance heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Low-Temperature Annealing of Nanoscale Defects in Polycrystalline Graphite

Polycrystalline graphite contains multi-scale defects, which are difficult to anneal thermally because of the extremely high temperatures involved in the manufacturing process. In this study, we demonstrate annealing of nuclear graphite NBG-18 at temperatures below 28 °C, exploiting the electron wind force, a non-thermal stimulus. High current density pulses were passed through the specimens with a very low-duty cycle so that the electron momentum could mobilize the defects without heating the specimen. The effectiveness of this technique is presented with a significant decrease in electrical resistivity, defect counts from X-ray computed tomography, Raman spectroscopy, and nanoindentation-based mechanical characterization. Such multi-modal evidence highlights the feasibility of nanoscale defect control at temperatures about two orders of magnitude below the graphitization temperature.

Liu, Gongyuan↗

Material variability as measured by low temperature electrical resistivity.

Low temperature electrical resistivity was used to determine the material variability (1) between different manufacturers, (2) between different heats from the same manufacturer, and (3) within a given heat for Al 2024, Al-5% Mg alloys, Inconel 718, A286 stainless, and AISI 316. Generally, the coefficient of variation for solution annealed alloys ranged from 1.2 to 14% between manufacturers, 0.8 to 5.1% between heats, and 0.1 to 1.6% within a heat with stainless steels at the low ends and Al 2024 at the high ends. The variability is increased if the material is in a precipitation-hardened condition. A statistical analysis suggests that the variability within a heat is non-normal.

Clark, A. F.↗

A brief description of geological and geophysical exploration of the Marysville geothermal area

Extensive geological and geophysical surveys were carried out at the Marysville geothermal area during 1973 and 1974. The area has high heat flow (up to microcalories per square centimeter-second, a negative gravity anomaly, high electrical resistivity, low seismic ground noise, and nearby microseismic activity. Significant magnetic and infrared anomalies are not associated with the geothermal area. The geothermal anomaly occupies the axial portion of a dome in Precambrian sedimentary rocks intruded by Cretaceous and Cenozoic granitic rocks. The results from a 2.4-km-deep test well indicate that the cause of the geothermal anomaly is hydrothermal convection in a Cenozoic intrusive. A maximum temperature of 95 C was measured at a depth of 500 m in the test well.

Blackwell, D. D.↗

Dependence of resistivity on the doping level of polycrystalline silicon

The electrical resistivity of polycrystalline silicon films has been studied as a function of doping concentration and heat treatment. The films were grown by the chemical vapor decomposition of silane on oxidized silicon wafers. The resistivity of the as-deposited films was widely scattered but independent of dopant atom concentration at the lightly doped levels and was strong function of dopant level in the more heavily doped regions. Postdeposition heat treatments in an oxidizing atmosphere remove scatter in the data. The resultant resistivity for dopant levels less than 10 to the 16th atoms/per cu cm was approximately equal to that of intrinsic silicon. In the next 2 orders of magnitude increase in dopant level, the resistivity dropped 6 orders of magnitude. A model, based on high dopant atom segregation in the grain boundaries, is proposed to explain the results.

Fripp, A. L.↗

Soliton and strong Langmuir turbulence in solar flare processes

The occurrence of modulational instability in the current sheet of a solar flare is investigated. Special attention is given to the plasma microinstability in this sheet and its relation to the flare process. It is found that solitons or strong Langmuir turbulence are likely to occur in the diffusion region under solar flare conditions in which the electric resistivity could be enhanced by several orders of magnitude in the region, resulting in significant heating and stochastic acceleration of particles. A numerical example is used to demonstrate the transition of the magnetic field velocity and plasma density from the outer MHD region into the diffusive region and then back out again with the completion of the energy conversion process. This is all made possible by an increase in resistivity of four to five orders of magnitude over the classical value.

Song, M. T.↗

Nature of convection-stabilized dc arcs in dual-flow nozzle geometry. I - The cold flow field and dc arc characteristics. II - Optical diagnostics and theory

Steady-state low-current air arcs in a dual-flow nozzle system are studied experimentally. The cold flow field with no arc is investigated using a 12.7-mm diameter dual-flow nozzle in a steady-flow facility. Mach number and mass flux distributions are determined for various nozzle-pressure ratios and nozzle-gap spacing. It is found that the shock waves in the converging-diverging nozzles result in a decrease in overal resistance by about 15 percent. Also, Schlieren and differential interferometry techniques are used to visualize the density gradients within the arc plasma and thermal mantle. Both optical techniques reveal a laminar arc structure for a reservoir pressure of 1 atm at various current levels. Experimentally determined axial static pressure and cold-flow mass flux rate distributions and a channel-flow model with constant arc temperatre are used to solve the energy integral for the arc radius as a function of axial distance. The arc electric field strength, voltage, resistance, and power are determined with Ohm's law and the total heat transfer is related to arc power.

Serbetci, Ilter↗

Structural Acoustic Response of a Shape Memory Alloy Hybrid Composite Panel (Lessons Learned)

This study presents results from an effort to fabricate a shape memory alloy hybrid composite (SMAHC) panel specimen and test the structure for dynamic response and noise transmission characteristics under the action of thermal and random acoustic loads. A method for fabricating a SMAHC laminate with bi-directional SMA reinforcement is described. Glass-epoxy unidirectional prepreg tape and Nitinol ribbon comprise the material system. Thermal activation of the Nitinol actuators was achieved through resistive heating. The experimental hardware required for mechanical support of the panel/actuators and for establishing convenient electrical connectivity to the actuators is presented. Other experimental apparatus necessary for controlling the panel temperature and acquiring structural acoustic data are also described. Deficiency in the thermal control system was discovered in the process of performing the elevated temperature tests. Discussion of the experimental results focuses on determining the causes for the deficiency and establishing means for rectifying the problem.

Turner, Travis L.↗

We Just Want to Pump…You Up! Forecasting Grid-Connected Heat Pump Water Heater Energy Savings and Load Shifting Potential for the Southeast U.S.

Heat pump water heaters (HPWH) can achieve energy savings of 60-70% compared to conventional electric-resistance water heaters. However, even with a favorable simple payback period within the typical product lifetime, HPWHs make up only 1% of all electric water heaters sold in the residential sector. Market adoption is challenged, in part, by the lack of effective energy efficiency programs in the U.S. region with the greatest amount of residential electric water heaters. The recent integration of connected functionality into HPWHs offers the capability to shift load without undue negative impact on customers. This capability can provide value to utilities with peak load constraints, motivating them to promote HPWHs for the first time. This paper will present a methodology to forecast connected HPWH energy use and extrapolate load shifting potential for the Southeast U.S. region. The methodology leverages data from a robust connected HPWH field study conducted in the Pacific Northwest. A coefficient of performance (COP) relationship for HPWHs was developed using ambient and inlet water temperature data to forecast HPWH performance on a month-by-month basis. Using the forecasted COP, HPWH operating hours were calculated for meeting load, which serve as the proxy to extrapolate load shifting potential from the Pacific Northwest to the Southeast. As a use case, analytical results are presented for a specific utility. This methodology, in combination with market analysis, facilitates the development of customized energy savings and load shifting forecasts to understand the potential impacts of launching connected HPWH programs in specific utility service territories.

heat pump water heater, energy savings, load shift↗

Influence of Fiber Content, Thermal Cycles and Creep on Electrical Resistivity Measurements of SiCf/SiC Minicomposites

Fiber-reinforced Ceramic Matrix Composites (CMCs) are currently being used in high-temperature applications such as jet engine components. In such extreme environment applications, materials are exposed to many mechanical and thermal loading cycles during the life of the component. This exposure can degrade the component, and thus, components need to be monitored and inspected during service. The electrical resistivity nondestructive evaluation technique has been shown to be very sensitive to damage in CMCs, and although its performance is highly dependent on temperature, this temperature-dependence is still not well understood. Therefore, this current study aims to establish the influence of thermal cycles, creep, CVI-SiC matrix cracks and fiber volume fraction on the electrical resistance of Hi Nicalon and Hi-Nicalon Type S SiC fiber-reinforced minicomposites with BN interphases. Minicomposites with 97% CVI-SiC matrix volume fraction were used to characterize the electrical resistivity of the CVI-SiC matrix. Next, models were constructed to calculate fiber resistivity and onset and evolution of damage during tensile testing at room-temperature. The thermal cycles were achieved by heating as-received and precracked specimens to 1200°C and then cooling them to room temperature, with or without applied stress on fibers.

creep↗

Mechanical Properties and Real-Time Damage Evaluations of Environmental Barrier Coated SiC/SiC CMCs Subjected to Tensile Loading Under Thermal Gradients

SiC/SiC ceramic matrix composites (CMCs) require new state-of-the art environmental barrier coatings (EBCs) to withstand increased temperature requirements and high velocity combustion corrosive combustion gasses. The present work compares the response of coated and uncoated SiC/SiC CMC substrates subjected to simulated engine environments followed by high temperature mechanical testing to asses retained properties and damage mechanisms. Our focus is to explore the capabilities of electrical resistance (ER) measurements as an NDE technique for testing of retained properties under combined high heat-flux and mechanical loading conditions. Furthermore, Acoustic Emission (AE) measurements and Digital Image Correlation (DIC) were performed to determine material damage onset and accumulation.

Ceramic matrix composites↗

3D Printed Carbon Fiber Reinforced Carbon: An energy efficient alternative to graphite EFAS tooling

Carbon fiber preforms are printed in a Quasi-Isotropic layup, where the fibers are aligned to the X and Y axes, and ±45° in plane. Thermal and electrical conductivity values along the fiber axes are comparable to graphite but are extremely low through the Z axis. Low conductivity (high resistivity) in the axis of current flow enables more efficient Joule heating.

36 MATERIALS SCIENCE↗

A thermal/nonthermal model for solar hard X-ray bursts

A formalism is developed for analyzing high-resolution hard X-ray spectra, incorporating the coexistence of thermal and nonthermal bremsstrahlung. The two processes are physically linked by the presence of electric currents, which both heat the surrounding plasma via Joule dissipation and accelerate electrons via the runaway process. We use this formalism to analyze the flare of 1980 June 27 and find that both the gradual and spike components of the hard X-ray emission are consistent with runaway acceleration. We also find that significant heating is observed only in the gradual component. The electric field is always sub-Dreicer, the maximum total potential drop in the acceleration region is found to be approximately 100 kV in two of the spikes, and the average accelerated electron flux is approximately 10(exp 34) electrons/s. We argue that classical resistivity is a valid assumption for this event and find the density in the current channels (approximately 10(exp 11)/cc) and a lower limit on the volume of the heated plasma. We find that the ratio of the electric field to the Dreicer field (epsilon = E/E(sub D) varies systematically, whereas the value of E alone does not. We also find that the acceleration region fragmented into many current/return current pairs, and that the fragmentation varied systematically. We also discuss further implications of this model.

Benka, Stephen G.↗

Thermoelectric heat pump water heater priced for mass market deployment with 30% energy savings

This project, a Cooperative Research and Development Agreement (CRADA) partnership between A. O. Smith and Oak Ridge National Laboratory (ORNL), was initiated to develop a heat pump water heater (HPWH) based on thermoelectric (TE) heat pump technology capable of seeing widespread market adoption by having a one-year payback versus electric resistance options.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Highly Conducting Graphite Epoxy Composite Demonstrated

Weight savings as high as 80 percent could be achieved if graphite polymer composites could replace aluminum in structures such as electromagnetic interference shielding covers and grounding planes. This could result in significant cost savings, especially for the mobile electronics found in spacecraft, aircraft, automobiles, and hand-held consumer electronics. However, such composites had not yet been fabricated with conductivity sufficient to enable these applications. To address this lack, a partnership of the NASA Lewis Research Center, Manchester College, and Applied Sciences, Inc., fabricated nonmetallic composites with unprecedented electrical conductivity. For these composites, heat-treated, vapor-grown graphite fibers were selected which have a resistivity of about 80 mW-cm, more than 20 times more conductive than typical carbon fibers. These fibers were then intercalated with iodine bromide (IBr). Intercalation is the insertion of guest atoms or molecules between the carbon planes of the graphite fibers. Since the carbon planes are not highly distorted in the process, intercalation has little effect on mechanical and thermal properties. Intercalation does, however, lower the carbon fiber resistivity to less than 10 mW-cm, which is comparable to that of metal fibers. Scaleup of the reaction was required since the initial intercalation experiments would be carried out on 20-mg quantities of fibers, and tens of grams of intercalated fibers would be needed to fabricate even small demonstration composites. The reaction was first optimized through a time and temperature study that yielded fibers with a resistivity of 8.7 2 mW-cm when exposed to IBr vapor at 114 C for 24 hours. Stability studies indicated that the intercalated fibers rapidly lost their conductivity when exposed to temperatures as low as 40 C in air. They were not, however, susceptible to degradation by water vapor in the manner of most graphite intercalation compounds. The 1000-fold scaleup experiments concluded that 114 C was near the optimum temperature, but that the intercalation time needed to be lengthened by a factor of 3.

Gaier, James R.↗

Static Dissipative Cable Ties, Such as for Radiation Belt Storm Probes

Methods of cyclically heating and cooling an article formed of a static dissipative ETFE resin, such as to reduce an electrical resistivity and/or to increase a tensile strength of the article, and methods of irradiating an article formed of a static dissipative ETFE resin, such as to increase a tensile strength of the article. Also disclosed herein are articles formed of a static dissipative ETFE resin, and processed in accordance with methods disclosed herein. Such an article may include, for example and without limitation, a cable strap to wrap, support, and/or secure one or more wires or cables, such as a cable tie.

Langley, Patrick T.↗

Modelling and Simulation of a Thermoelectric Heat Pump with Micro-Channel Heat Transfer

Thermoelectric heat pumps (TEHPs) have advantages of modularity and simple design for heating and cooling in some applications. Models of thermoelectric (TE) heat pumps are widely studied. Nevertheless, most existing modeling work focuses on the TE material or air-sourced TE modules. TEHP modeling, especially the relationship between modules and heat exchangers, has not been comprehensively conducted. This work presents a water-to-water TEHP modeling framework that combines Goldsmid’s approach for TE material performance, Gnielinski’s correlation for convective heat transfer, and thermal balance theory for heat exchange networks. This combined framework provides an accurate theoretical analysis of the water-to-water TEHP system. Subsequently, the framework was used to empirically determine TE material properties (electric resistivity, thermal conductivity, and Seebeck coefficient) that minimize modeling errors versus experimentally observed values from the literature. Finally, an additional set of experimental TEHP data was used to validate the model, all with relative absolute deviations of approximately 10% when predicting heating capacity and 10%–20% when forecasting cooling capacity at a 30 K temperature lift. For future work, people can further develop models of TEHPs with an air-based heat sink on one side and water channels on the other side.

Wan, Hanlong↗