Search NASA⌕ Search

SEARCH · Search NASA

Results for “electricity model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Electrical Power Distribution and Control Modeling and Analysis

This slide presentation reviews the use of Electrical Power Distribution and Control (EPD&C) Modeling and how modeling can support analysis. The presentation discusses using the EASY5 model to simulate and analyze the Space Shuttle Electric Auxiliary Power Unit. Diagrams of the model schematics are included, as well as graphs of the battery cell impedance, hydraulic load dynamics, and EPD&C response to hydraulic load variations.

Fu, Johnny S.↗

Holistic Fuel Cell Electric Vehicle/Hydrogen Station Optimization Model (CRADA CRD-18-00745 Final Report)

The National Renewable Energy Lab (NREL), Argonne National Lab (ANL), Sandia National Lab (SNL), and Frontier Energy, Inc comprise a team that will perform a review of currently available models that can simulate both a hydrogen station and a fuel cell electric vehicle (FCEV), and whose owners are willing to make them available freely. We will then down select to a single model or model pair, secure agreements for their free use, and validate the resulting model or coupled models. For example, we may evaluate an existing 1-D hydrogen fueling model developed by Kyushu University for the Japanese New Energy and Industrial Technology Development Organization (NEDO). The validation will take place using data from various sources, potentially including the European Joint Research Center (JRC) HyTransfer project, SAE testing performed by Powertech to validate SAE J2601, and whole-station validation using the NREL’s Hydrogen Infrastructure Testing and Research Facility (HITRF). The team will make the model and all the validation data open to the public at the end of the project.

1-D hydrogen fueling model↗

Demonstration of a modeling toolkit for the design of building electrical distribution systems

The deployment of building equipment (e.g., lighting, security) and miscellaneous electrical loads that fundamentally require DC power for operation is increasing. Powering these DC loads has traditionally required an AC/DC converter, but the installation of photovoltaic (PV) and battery energy storage systems that primarily produce DC power eliminates the need for AC/DC converters at each end-device. However, analyzing system energy efficiency and cost for different electrical distribution architectures can be challenging as software tools that support this are not readily available. This paper presents preliminary results from a laboratory verification of the Building Electrical Efficiency Analysis Model (BEEAM) toolkit that was developed to address this gap. Three different eight-luminaire lighting systems comprised of market-available products were designed and modeled: one that used traditional AC distribution, a second that used a hybrid AC -to- centralized DC electrical distribution architecture, and a third that used a hybrid AC -to- distributed DC architecture. Notably, AC/DC conversions are required in all three systems. BEEAM models for LED drivers as well as Power-over-Ethernet (PoE) switches were created using laboratory characterization data. The lighting systems were simulated in Modelica, and the results were compared with each other and physics-based expectations. Simulation results show that PoE system energy efficiency is highly dependent on both device specification (e.g., LED driver and PoE switch efficiency) and system architecture (e.g., PoE switch loading) choices, as expected. For the products and system architectures selected for this study, the two DC systems were found to be less efficient than the AC system over the course of typical operation. In future work, simulation results will be compared with laboratory measurements to validate the usefulness of this software for design, and lighting systems with integrated PV and battery energy storage will be simulated to quantify the energy performance improvements that result from the elimination of some AC/DC converters.

Waghale, Anay S.↗

'Alfven wing' models of the induced electrical current system at Io - A probe of the ionosphere of Io

A novel class of models of the Alfven wing interaction between the Io plasma torus and Io's ionosphere has been developed and used to compute the magnetic field fluctuations at the position of the Voyager 1 flyby. These computations of the magnetic field signature are compared with the magnetic field measurements made during the flyby, and the differences between the model and observations are used as a probe of the structure of Io's ionosphere. The results of this model fitting indicate that a significant atmospheric neutral column density is required over a major part of the trailing hemisphere. This can be consistent with the cold-trap model for Io's neutral atmoshpere only if the major plumes near the center of the trailing hemisphere provide significant volumetric coverage. The Io plasma torus charged-mass density required for a proper match to the data is larger than earlier estimates based on the width of the Alfven wing signature.

Herbert, F.↗

A study of the electric field in an open magnetospheric model

The qualitative properties of an open magnetosphere and its electric field are examined and compared to a simple model of a dipole in a constant field and to actual observations. Many of these properties are found to depend on the separatrix, a curve connecting neutral points and separating different field-line regimes. In the simple model, the electric field in the central polar cap tends to point from dawn to dusk for a wide choice of external fields. Near the boundary of the polar cap electric equipotentials curve and become crescent-shaped, which may explain the correlation of polar magnetic variations with the azimuthal component of the interplanetary magnetic field, reported by Svalgaard. Modifications expected to occur in the actual magnetosphere are also investigated: in particular, it appears that bending of equipotentials may be reduced by cross-field flow during the merging of field lines and that open field lines connected to the polar caps emerge from a long and narrow slot extending along the tail.

Stern, D. P.↗

Evaluation of Electrical System Requirements for Implementing Turbine Electrified Energy Management

Turbine Electrified Energy Management (TEEM) is a concept concerned with the management of energy in an electrified propulsion system. The management of energy in the hybrid-electric architecture has potential to benefit the turbomachinery and the aircraft it powers. The concept is particularly useful for improving operability during transient operation and could be leveraged to design a better performing engine. The concept utilizes electric machines coupled to the engine shafts and an electric power distribution system that includes energy storage. A controller is used to decide when and how energy is moved around the electrified propulsion system, particularly when considering energy conversion between mechanical and electrical forms. Prior work has shown that the electric machines can be used to supply/or extract supplemental power to/from the engine shafts to improve their operability and achieve or enable propulsion efficiency and performance benefits. However, the previous studies did not consider the practical constraints of the electrical machines and energy storage devices that are required for implementing the TEEM system architecture concept. This paper presents an integrated engine and electrical system model that is used to evaluate the electrical system requirements. The model captures the physics of the conceptual, Advanced Geared Turbofan 30,000lbf (AGTF30) engine, which features advanced technologies such as a compact gas turbine and a variable area fan nozzle. For this work, the engine is augmented with electrical system components that allow for the implementation of the TEEM concept. The evaluation presented suggests the potential of the TEEM concept to provide performance benefits for a turbofan engine.

electrified↗

Evaluation of Electrical System Requirements for Implementing Turbine Electrified Energy Management

Turbine Electrified Energy Management (TEEM) is a concept concerned with the management of energy in an electrified propulsion system. The management of energy in the hybrid-electric architecture has potential to benefit the turbomachinery and the aircraft it powers. The concept is particularly useful for improving operability during transient operation and could be leveraged to design a better performing engine. The concept utilizes electric machines coupled to the engine shafts and an electric power distribution system that includes energy storage. A controller is used to decide when and how energy is moved around the electrified propulsion system, particularly when considering energy conversion between mechanical and electrical forms. Prior work has shown that the electric machines can be used to supply/or extract supplemental power to/from the engine shafts to improve their operability and achieve or enable propulsion efficiency and performance benefits. However, the previous studies did not consider the practical constraints of the electrical machines and energy storage devices that are required for implementing the TEEM system architecture concept. This paper presents an integrated engine and electrical system model that is used to evaluate the electrical system requirements. The model captures the physics of the conceptual, Advanced Geared Turbofan 30,000lbf (AGTF30) engine, which features advanced technologies such as a compact gas turbine and a variable area fan nozzle. For this work, the engine is augmented with electrical system components that allow for the implementation of the TEEM concept. The evaluation presented suggests the potential of the TEEM concept to provide performance benefits for a turbofan engine.

hybrid electric propulsion↗

Nuclear's Role in the U.S. Electricity System: A Multi-Model Inter-Comparison Analysis

A variety of US electric power sector capacity expansion models are used by decision makers and analysts to evaluate competition among generation, transmission, and storage technologies to meeting the demands of the system. CEMs use least-cost optimization to identify optimal portfolios of investments capable of satisfying all specified requirements. While CEMs are a useful tool to inform pathways to meet future needs, projections can differ significantly between tools for apparently similar scenario assumptions. Differences in model structure, scope, and input assumption contribute to this issue. This work compares model response with harmonization between four modeling teams on issues significant to the representation and development of nuclear energy.

capacity expansion model↗

Datasets for Widespread Residential Space Heating Electrification in Texas

In this experiment, we explore long term patterns in electricity demand driven by the dual effects of full electrification of space heating in Texas (by adoption of electric heat pumps), and climate change. We use a predictive model of electricity demand, climate projections, and an open source nodal power system (DC Optimal Power Flow) model of the Electric Reliability Council of Texas (ERCOT) system. Heat pumps are a more energy efficient way of providing space heating and cooling in homes. We attempt to exhaustively investigate the impacts of full residential space heating electrification by adoption of heat pumps for the segment of Texas households that currently rely on fossil fuels (about 40%), while simultaneously incorporating climate change meteorological variables. We explore a range of scenarios of heat pump efficiency and climate uncertainty over a long period of future years (2020-2099). In total, the simulation experiment generates 1,280 simulation years of hourly data. We report and analyze results in form of impacts on residential load, total load, peak load, seasonality of peaking, and reliability measured by occurrence and frequency of loss of load events. While the experiment is for ERCOT, the insights and approach can be applied to other regions. The results from the analysis can inform system planners on a range of potential capacity requirements/ reliability implications and/or risks of full space heating electrification via the adoption of electric heat pumps, given the uncertainty in the scenarios/ climate futures. The dataset includes model output for residential, non residential and total load, and the results from the GO ERCOT model runs for 4 RCP Scenarios (RCP 4.5 Cooler, RCP 4.5 Hotter, RCP 8.5 Cooler, RCP 8.5 Hotter), 4 Heating electrification Scenarios (Base , Standard Efficiency HP, High Efficiency HP, Ultra-High Efficiency HP) over 80 years (2020-2099). The metrological variables at BA scale were weighted weighted using population projections consistent with the SSP3 scenario.

Climate Change↗

Analyzing Distributed Processing For Electric Utilities

Distributed Processing Trade-Off Model for Electric Utility Operation computer program based upon study performed at California Institute of Technology for NASA's Jet Propulsion Laboratory. Study presented technique addressing question of tradeoffs between expanding communications network or expanding capacity of distributed computers in energy-management systems (EMS) of electric utility. Gives EMS planners macroscopic tool for evaluation of architectures of distributed-processing systems and major technical and economic tradeoffs as well as interactions within systems.

Klein, Stanley A.↗

Comparison between field mill and corona point instrumentation at Kennedy Space Center - Use of these data with a model to determine cloudbase electric fields

A novel coronal current-determining instrument is being used at NASA-KSC which overcomes previous difficulties with wind sensitivity and a voltage-threshold 'deadband'. The mounting of the corona needle at an elevated location reduces coronal and electrode layer space-charge influences on electric fields, rendering the measurement of space charge density possible. In conjunction with a space-charge compensation model, these features allow a more realistic estimation of cloud base electric fields and the potential for lightning strike than has previously been possible with ground-based sensors.

Markson, R.↗

Electrical Transfer Function and Poling Mechanisms for Nonlinear Optical Polymer Modulators

Electro-Optic Polymers hold great promise in increased electro-optic coefficients as compared to their inorganic corollaries. Many researchers have focused on quantum chemistry to describe how the dipoles respond to temperature and electric fields. Much work has also been done for single layer films to confirm these results. For optical applications, waveguide structures are utilized to guide the optical waves in 3 layer stacks. Electrode poling is the only practical poling method for these structures. This research takes an electrical engineering approach to develop poling models and electrical and optical transfer functions of the waveguide structure. The key aspect of the poling model is the large boundary charge density deposited during the poling process. The boundary charge density also has a large effect on the electrical transfer function which is used to explain the transient response of the system. These models are experimentally verified. Exploratory experiment design is used to study poling parameters including time, temperature, and voltage. These studies verify the poling conditions for CLDX/APC and CLDZ/APEC guest host electro optic polymer films in waveguide stacks predicted by the theoretical developments.

Watson, Michael Dale↗

Brayton Cycle Power Conversion Model for MW-Class Nuclear Electric Propulsion Mars Missions

A Brayton cycle based power conversion system for a nuclear electric propulsion application was modeled in Simulink as part of NASA’s space nuclear program in order to explore the impact of technology assumptions on the power conversion system performance and capabilities. The thermodynamic processes and algorithms within the model are documented, including a higher fidelity reactor model. Assumptions are chosen based on literature and subject matter expert review, and example results and capabilities of the model are shown. The effects of the turbine inlet and compressor inlet temperature on radiator area and thermal efficiency are discussed. For a He-Xe closed Brayton cycle, radiator areas as low as 650 m2/MWe are shown, with corresponding thermal efficiences at roughly 20% for the minimal radiator area solutions.

Brayton↗

Nightside plasmapause positions observed by DE-1 as a function of geomagnetic indices - Comparison with whistler observations and model calculations

The paper analyzes 28 plasmapause crossings made by the DE1 satellite in the night local time sector (from January to March 1982). Different signatures obtained by the Retarding Ion Mass Spectrometer instrument have been used for this analysis. The observed plasmapause positions (Lpp) have been organized as a function of geomagnetic indices. They are compared with the empirical relationship deduced by Carpenter and Parks (1973) from whistler observations. Moreover, the dependence of Lpp versus Kp has been inferred from model calculations using Kp dependent electric and magnetic fields derived from McIlwain's (1974) E3H electric field model and M2 magnetic field model respectively. Stationary models as well as time dependent ones, have been used to determine the positions of the plasmapause. The results of the model calculations are compared to the observations.

Decreau, P. M. E.↗

Dynamics Explorer guest investigator

A data base of satellite particle, electric field, image, and plasma data was used to determine correlations between the fields and the particle auroral boundaries. A data base of 8 days of excellent coverage from all instruments was completed. The geomagnetic conditions associated with each of the selected data periods, the number of UV image passes per study day that were obtained, and the total number of UV images for each day are given in tabular form. For each of the days listed in Table 1, both Vector Electric Field Instrument (VEFI) electric potential data and LAPI integrated particle energy fluxes were obtained. On the average, between 8 and 11 passes of useful data per day were obtained. These data are displayed in a format such that either the statistical electric field model potential or the statistical precipitation energy flux could be superimposed. The Heppner and Maynard (1987) and Hardy et al. (1987) models were used for the electric potential and precipitation, respectively. In addition, the auroral image intensity along the Dynamics Explorer-2 satellite pass could be computed and plotted along with the LAPI precipitation data and Hardy et al. (1987) values.

Sojka, Jan J.↗

Investigation of a vibration-damping unit for reduction in low-frequency vibrations of electric motors

The vibroacoustical characteristics of different types of electric motors are discussed. It is shown that the basic source of low frequency vibrations is rotor unbalance. A flexible damping support, with an antivibrator, is used to obtain the vibroacoustical effect of reduction in the basic harmonic of the electric motor. A model of the electric motor and the damping apparatus is presented. Mathematical models are developed to show the relationships of the parameters. The basic purpose in using a calculation model id the simultaneous replacement of the exciting force created by the rotor unbalance and its inertial rigidity characteristics by a limiting kinematic disturbance.

Grigoryey, N. V.↗

High Voltage Multiplier: A New, Compact Design using SiC High Frequency MOSFETs

In this report, power supply models for particle accelerators are examined and electrical equivalent model for a high-voltage multiplier power supply is developed. The ultimate goal is to provide the blue prints for the realization of real world models to power both the electrical and magnetic dipoles that make up the key components of the typical particle accelerator assembly.

43 PARTICLE ACCELERATORS↗