Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrode degradation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Battery state-of-health diagnostics during fast cycling using physics-informed deep-learning

Rapid, in-situ Li-ion battery state-of-health (SOH) quantification is challenging. Li-ion battery aging can vary significantly with chemistry, operating conditions, cycling demands, electrode design, and operation history. As a cell ages, optimal and safe operating conditions need to be adapted to account for battery degradation by tracking critical aging modes such as loss-of-lithium-inventory (LLI), loss-of-active-material (LAM) in either electrode, and/or impedance rise. This manuscript describes a framework for identifying battery aging modes in-operando using fast-rate voltage charge/discharge responses. The framework uses a physically based Li-ion battery model to produce synthetic high-rate responses at aged states. The aging model is calibrated against experimental data from cells with different electrode loadings and cycled under a variety of fast-charging conditions (1 h, 15 min, 10 min, and 7 min charging). The synthetically generated high-rate responses at aged states are then used to train a deep-learning model to identify real cell state-of-health from fast charge/discharge battery voltage responses. The synthetically trained deep-learning model performance is validated by comparing to standard incremental capacity analysis and half-cell measurements. Finally, the framework demonstrates the benefits of using high-rate physics-based models to generate synthetic data for training deep-learning models.

25 ENERGY STORAGE↗

Hydrogen Crossover Flux through Two-Dimensional Nanomaterials

Energy storage and conversion devices require an ion-exchange membrane with high transmission of charge-balancing ions and separation of anode and cathode electrolytes/gases. This ensures optimum device performance. Most conventional membranes suffer huge cross-permeation resulting in low energy efficiency and material degradation. This work investigated hydrogen permeability and proton transmission through membrane electrode assemblies (MEAs) containing a monolayer of hexagonal boron nitride and single-layer and bi-layer graphene in a gas-phase small-scale cell and a liquid cell. Here we found that the hydrogen crossover flux through MEAs with 2D materials was inhibited by at least a factor of 5 compared to the one without. Single-layer graphene and boron nitride enabled high proton transmission, but bi-layer graphene inhibited proton conduction. Defect visualization of 2D materials revealed few atomic-scale defects in graphene. These findings suggest that a monolayer of 2D material may provide good selectivity for energy conversion and storage devices by blocking species crossover while allowing high proton transmission.

2D materials↗

Understanding and Strategies for Controlled Interfacial Phenomena in Lithium-Ion Batteries and Beyond

Electrolyte chemistry and properties and electrode structure and chemical properties particularly at the interfaces are crucial for the development of advanced battery components. This project focused on elucidating the roles of the electrolyte and electrode on the formation and evolution of the SEI layer and cell electrochemical performance on silicon and on Li metal anodes. For Si nano/microstructures we evaluated lithiation, volume changes, reactivity, and chemo-mechanical transformations as functions of nanoparticle size, shape, presence of coatings, electrolyte composition, electron leakage to the electrolyte, and cycling. For Li metal anodes we provided detailed analyses of the electrode and electrolyte effects on interfacial reactivity and as a function of microstructural evolution and underlying stochasticity as dendrites nucleate and grow. We thoroughly investigated and simulated how the chemistry of the various components of the electrolyte and the electrode architecture may affect the electrochemical reactions as well as cell degradation. A multiscale modeling approach was utilized, where atomistic simulations informed about the microscopic behavior of the system, and intermediate time and length scales were investigated with mesoscopic models. Results were also tested against selected experiments from our collaborators. The combined theoretical-experimental strategy saves costs by utilizing predictions from computational analyses to guide experimentation.

25 ENERGY STORAGE↗

Durable High Power Density Fuel Cell Cathodes for Heavy-Duty Vehicles

The aim of this project was to advance the performance and durability of proton exchange membrane fuel cells (PEMFCs) for their use in the electrification of heavy-duty vehicles (HDVs). With an emphasis on total cost of ownership for HDVs, the development of the fuel cells focuses more heavily on the efficiency and lifetime (i.e., durability) than past focus on platinum group metal (PGM) costs and power density. This project takes a unique approach to achieving these goals – using next-generation polymer electrolytes in the electrodes that yield significant improvements in performance and dramatic reductions in degradation rates. A key outcome of the project was an ionomer/catalyst combination of a Pt catalyst on a low surface area carbon support (Pt/LSC) with a high oxygen permeability ionomer (HOPI) that met both the project’s performance target (current at 0.8 V, >0.3 A/cm 2 ) and durability target (voltage loss at 0.8 A/cm 2 , <30 mV) with the goal of projected a >4X increase in life-time.

08 HYDROGEN↗

The role of oxygen in porous molybdenum electrodes for the alkali metal thermoelectric converter

A model for chemical reactions in porous molybdenum electrodes is presented which is based on thermochemical and kinetic data, known sodium-molybdenum-oxygen chemistry, X-ray diffraction analysis of molybdenum and molybdenum oxide electrodes, and the electrochemical behavior of the cell. Enhanced sodium transport through the electrode in its optimum performance state is found to be due to the high sodium ion conductivity of molten Na2MoO4 in the pores, and the electrical conduction to the molybdenum matrix by Na2Mo3O6. The decline of electrode performance is shown to be due to a combination of loss mechanisms for the Na-Mo-O compounds including reduction at short circuit, disproportionation of Na2Mo3O6 at open circuit, and the evaporation of Na2MoO4 at elevated temperature. It is suggested that operation of the cell at moderate voltage of about 0.5 V corresponding to maximum power may be a more stable condition for the porous electrode than open-circuit stand or short-circuit, where degradation reactions are heightened.

Williams, R. M.↗

On the role of the zirconia/ceria interface in the degradation of solid oxide electrolysis cells

Gd-doped Ceria (GDC) barrier layers are widely used in solid oxide electrolysis cells to prevent reactions between the Y-stabilized Zirconia (YSZ) electrolyte and oxygen electrode. In some cases, electrolysis operation causes fracture near the GDC/YSZ interface. Here, we explain this effect using a numerical calculation, showing that a peak oxygen pressure is observed near the GDC/YSZ interface during electrolysis operation. Moreover, GDC/YSZ interdiffusion and possible zirconate phase formation occurring during electrode firing yield a low oxygen ion conductivity region that introduces a much higher peak oxygen partial pressure at the interdiffusion layer/YSZ interface, thereby exacerbating degradation. The results indicate that the peak pressure can be reduced and, thereby, damage can be mitigated by altering processing in order to minimize interdiffusion, decreasing the GDC layer thickness, and reducing oxygen electrode polarization resistance or altering electrolyte transport properties, e.g., changing the Gd doping level of GDC to increase the oxygen vacancy diffusivity.

Physics↗

Hydrogen-Bonding Interactions in Hybrid Aqueous/Nonaqueous Electrolytes Enable Low-Cost and Long-Lifespan Sodium-Ion Storage

Although “water-in-salt” electrolytes have opened a new pathway to expand the electrochemical stability window of aqueous electrolytes, the electrode instability and irreversible proton co-insertion caused by aqueous media still hinder the practical application, even when using exotic fluorinated salts. In this study, an accessible hybrid electrolyte class based on common sodium salts is proposed, and crucially an ethanol-rich media is introduced to achieve highly stable Na-ion electrochemistry. Here, ethanol exerts a strong hydrogen-bonding effect on water, simultaneously expanding the electrochemical stability window of the hybridized electrolyte to 2.5 V, restricting degradation activities, reducing transition metal dissolution from the cathode material, and improving electrolyte–electrode wettability. The binary ethanol–water solvent enables the impressive cycling of sodium-ion batteries based on perchlorate, chloride, and acetate electrolyte salts. Notably, a Na 0.44 MnO 2 electrode exhibits both high capacity (81 mAh g –1 ) and a remarkably long cycle life >1000 cycles at 100 mA g –1 (a capacity decay rate per cycle of 0.024%) in a 1 M sodium acetate system. The Na 0.44 MnO 2 /Zn full cells also show excellent cycling stability and rate capability in a wide temperature range. The gained understanding of the hydrogen-bonding interactions in the hybridized electrolyte can provide new battery chemistry guidelines in designing promising candidates for developing low-cost and long-lifespan batteries based on other (Li + , K + , Zn 2+ , Mg 2+ , and Al 3+ ) systems.

25 ENERGY STORAGE↗

Soft x ray window encapsulant for HgI2 detectors

HgI2 is an excellent semiconductor material for a low energy, room temperature x-ray spectrometer. The high values of the atomic numbers for its constituent elements gives high x-ray and gamma ray stopping power. The band gap of HgI2 is significantly higher than other commonly used semiconductors. Owing to the large value band gap, the leakage current for HgI2 devices is smaller, thus allowing low noise performance. Devices fabricated from HgI2 crystals have demonstrated energy resolution sufficient to distinguish the x-ray emission from the neighboring elements on the periodic table. Also the power requirements of HgI2 are very low. These characteristics make a HgI2 spectrometer an ideal component in a satellite based detection system. Unfortunately, HgI2 crystals tend to deteriorate with time, even if protected by standard semiconductor encapsulants. This degradation ruins the performance of the device in terms of its energy resolution and pulse amplitude. The degrading mechanism is believed to be material loss occurring from below the electrodes, due to high vapor pressure of HgI2 at room temperature. To address this major obstacle to rapid expansion of HgI2 technology, a research program aimed at improving device stability by encapsulation with inert polymeric materials was carried out. The program focused specifically on optimizing the encapsulant materials and their deposition techniques. The principal objectives for this program were device encapsulation, device testing, and accelerated testing to ensure very long term stability of these high resolution sensors. A variety of encapsulants were investigated with the selection criteria based on their chemical diffusion barrier properties, mechanical stability, reactivity, and morphology of encapsulant films. The investigation covered different classes of encapsulants including solvent based encapsulants, vapor deposited encapsulants, and plasma polymerized encapsulants. A variety of characterization techniques were employed to examine their effectiveness in stabilizing HgI2 devices; these included permeability evaluation, vacuum and heat testing, scanning electron microscopy (SEM) as well as studying the detector performance of coated detectors. The plasma polymerized films appear to have entirely solved the HgI2 degradation problem. Another achievement of this program was the development of an accelerated testing technique which correlates extremely well with long term tesing.

Entine, G.↗

Diagnostic-free onboard battery health assessment

Diverse usage patterns induce complex and variable aging behaviors in lithiumion batteries, complicating accurate health diagnosis and prognosis. Separate diagnostic cycles are often used to untangle the battery’s current state of health from prior complex aging patterns. However, these same diagnostic cycles alter the battery’s degradation trajectory, are time-intensive, and cannot be practically performed in onboard applications. Here, in this work, we leverage portions of operational measurements in combination with an interpretable machine learning model to enable rapid, onboard battery health diagnostics and prognostics without offline diagnostic testing and the requirement of historical data. We integrate mechanistic constraints within an encoder-decoder architecture to extract electrode states in a physically interpretable latent space and enable improved reconstruction of the degradation path. The health diagnosis model framework can be flexibly applied across diverse application interests with slight fine-tuning.

battery aging reconstruction↗

Innovative duo-recombination layer design for effective hydrogen crossover mitigation in advanced MEAs for PEM water electrolyzers

Hydrogen crossover in proton exchange membrane water electrolyzers (PEMWEs) poses a safety hazard, reduces the overall efficiency, and limits the operational differential pressure range. Here, in this study, a membrane electrode assembly (MEA) with innovative Pt duo-recombination layer (DRL) design is developed by the unique reactive spray deposition technology (RSDT). The novel design comprises two thin RLs integrated within the volume of the membrane and has a total Pt loading of only 0.04 mg Pt cm −2 . Long-term durability test for over 3000 h is performed with as-fabricated MEA at steady-state conditions typical for an industrial hydrogen production system. The results from the durability test show that the newly developed DRL design effectively suppresses the H2 crossover to below 0.5 vol%. Furthermore, comprehensive post-test characterization of the MEA is performed and potential failure mechanisms in the Pt RLs observed during the durability test are identified and discussed in detail for the first time.

08 HYDROGEN↗

Capacity Fade of Graphite/NMC811: Influence of Particle Morphology, Electrolyte, and Charge Voltage

LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) is an important Li-ion battery cathode material; however, there is a tradeoff between delivered capacity and capacity retention. As the charge potential increases the capacity rises but at the expense of capacity retention. The decrease in capacity retention has been ascribed to several factors including particle cracking, surface reconstruction, transition metal dissolution, and electrolyte reactivity. The present study compares 4.1 and 4.3 V charging limits in commercially relevant graphite/NMC811 pouch cells for single crystal (SC) and polycrystalline (PC) NMC811 with ethylene carbonate (EC)-containing or EC-free electrolytes. The electrochemistry is rationalized through analysis of electrochemical impedance spectroscopy, positive electrode X-ray photoelectron spectroscopy, soft X-ray absorption spectroscopy, X-ray diffraction, and negative electrode mapping by X-ray fluorescence. Graphite/SC-NMC811 cells show high-capacity retention at 4.1 V but exhibit degradation at 4.3 V charging potentials. The EC-free electrolyte cells led to higher capacity fade, especially when charged to 4.3 V. Cathode dissolution and deposition on the negative electrode from PC-NMC811 cells was higher than for samples from SC-NMC811 cells. This study reveals the impact of material type, charge voltage, and electrolyte composition on the reactions at the positive electrode, their influence on the negative electrode, and evolution with cycle number.

36 MATERIALS SCIENCE↗

Highly Active and Durable Air Electrodes for Reversible Protonic Ceramic Electrochemical Cells Enabled by an Efficient Bifunctional Catalyst

The commercialization of reversible protonic ceramic electrochemical cells is hindered by the lack of highly active and durable air electrodes exposed to high concentration of steam under operating conditions. We report findings that dramatically enhance the electrocatalytic activity and stability of a conventional (La 0.6 Sr 0.4 ) 0.95 Co 0.2 Fe 0.8 O 3-δ (LSCF) air electrode by a multiphase catalyst coating composed of a conformal Pr 1-x Ba x CoO 3-δ thin film and exsolved BaCoO 3-δ nanoparticles, are reported. At 600 °C, the catalyst coating decreases the polarization resistance of the LSCF air electrode by a factor of 25 (from 1.09 to 0.043 Ω cm 2 ) in air and the degradation rate by two orders of magnitude (from 1.0 × 10 -2 to 1.8 × 10 -4 Ω cm2 h -1 in humidified air with 30 vol% H2O). Further, a single cell with the catalyst-coated LSCF air electrode at 600 °C demonstrates a high peak power density of 1.04 W cm -2 in the fuel cell mode and a high current density of 1.82 A cm -2 at 1.3 V in the electrolysis mode. The significantly enhanced performance of the LSCF air electrode is attributed mainly to the high rate of surface oxygen exchange, fast surface proton diffusion, and the rapid H 2 O and O 2 dissociation on the catalysts.

36 MATERIALS SCIENCE↗

Investigation of Membrane Chemical Degradation as a Function of Catalyst Platinum Loading

Membrane chemical degradation is one of many factors that can impact fuel cell durability. Additionally, the fuel cell’s lifetime heavily depends on the membrane and its ability to maintain chemical and mechanical integrity. Previous studies indicate that chemical degradation is due to the formation of hydroxyl radicals that attack the polymer structure resulting in membrane thinning, pinhole formation, and the release of fluoride and sulfate ions. Membrane durability was investigated using ultra-low Pt electrode loadings (≤ 0.1 mg Pt cm -2 ). Accelerated stress testing (US-DOE protocols) demonstrated that the degradation rate was found to increase with higher Pt loadings. This is most likely due to more heterogeneous sites for radical formation due to hydrogen crossover to the cathode. We also explored membrane degradation rates while varying catalyst layer thickness, ionomer to carbon ratio, and types of carbon support. All of the aforementioned variables impact the membrane degradation rates.

25 ENERGY STORAGE↗

Comparative Analysis of Capacitive Sensors with Different Geometrical layouts for Cable Insulation Degradation Detection

This paper presents a comparative analysis between an Interdigital Capacitor (IDC) sensor and a Serpentine Capacitive (SRC) sensor. The effects of electrode layouts on sensor performance are studied by means of finite element simulation where the geometrical dimensions (except electrode length) and material characteristics of both sensors are identical. Conformal IDC and SRC sensors with equal sensor area are modeled on a cable surface. The simulation results show a tradeoff between IDC and SRC sensors in terms of sensitivity and penetration depth. The SRC sensor shows 13.3% increase in sensitivity and 16.8% increase in capacitance compared to the IDC sensor, though the electric field penetration depth of the SRC sensor is 18.8% lower than the IDC sensor. In addition, the effects of change in electrode width, inter-electrode gap, and number of electrodes on SRC and IDC sensor comparative performance are evaluated.

Interdigital Capacitance, Serpentive Capacitive Se↗

Lattice-Oxygen-Driven Selective Oxidation Strategy for Stable Argyrodite Solid-State Lithium Metal Batteries

All-solid-state lithium metal batteries (ASSLMBs) with Li6PS5Cl argyrodite electrolytes and high-voltage LiNi0.8Mn0.1Co0.1O2 (NMC811) cathodes offer high energy density but suffer from rapid capacity fading due to the layered-to-rock-salt transition of NMC811 and structural degradation of Li6PS5Cl from parasitic interfacial reactions. Here, we demonstrate a catholyte engineering strategy using a Li2S scavenging additive to suppress interfacial reactivity and preserve the structural and electrochemical stability of both NMC811 and Li6PS5Cl. Incorporating 0.10 wt.% Li2S enables exceptional cycling stability, achieving 76% capacity retention after 550 cycles at C/10 and 88% retention after 800 cycles at C/3 at 60 degrees C, compared with rapid failure in pristine cells. Spectroscopic, electrochemical, and morphological analyses confirm that Li2S maintains electrode integrity by sustaining particle contact and suppressing phase decomposition. This work elucidates interfacial degradation pathways in NMC811/argyrodite systems and introduces a low-cost, scalable strategy to stabilize nickel-rich oxide cathodes in ASSLMBs, advancing their practical viability.

25 ENERGY STORAGE↗

Mitigation of rapid capacity decay in silicon-LiNi 0.6 Mn 0.2 Co 0.2 O 2 full batteries

Silicon (Si)-based materials have been considered as the most promising anode materials for high-energy-density lithium-ion batteries because of their higher storage capacity and similar operating voltage, as compared to the commercial graphite (Gr) anode. But the use of Si anodes including silicon-graphite (Si-Gr) blended anodes often leads to rapid capacity decay in Si-Gr/LiNixMnyCo z O 2 (x+y+z=1) full cells, which has been attributed to surface instability of the Si component. In addition to stabilizing the surface, this work investigates the potential of the Si-Gr blended anodes in a full-cell configuration and its impact on the capacity contribution from active components. Using dQ/dV plots of the full cells, a powerful but simple-to-implement differential potential approach is developed to decouple the capacity contribution and degradation from the graphite and silicon components. Data collected from three-electrode cells confirm the results from the differential potential approach, which suggests a voltage slippage to a higher voltage at the blended anode side. Additionally, the voltage slippage causes a reduced utilization of the Gr component and exacerbates side reactions between the Si-Gr anode and carbonate electrolytes. Furthermore, based on these failure mechanisms, we adopted a mitigation strategy to tune the open circuit voltage of the prelithiated anode while stabilizing the surface. As a result, the full cells with the modified Si-Gr anodes (mass loading, 2.5 mAh/cm 2 ) offer a highly reversible full-cell energy density of 390 Wh/kg (based on the mass of both anode and cathode materials in a full cell) with a cycling CE of 99.9% over 200 cycles.

25 ENERGY STORAGE↗

Diffusion of NiH on Ni(111) and of Ni with Adsorbed H on Ni(111) in the Context of Ni Coarsening in Solid Oxide Cells

In the Ni-based hydrogen electrode of a solid oxide cell (SOC), Ni coarsening is an important degradation mechanism and could be enhanced by NiH diffusing on the Ni particle surfaces. Here, in this work, the average lifetime and diffusion distance of NiH on Ni(111) are computed using density-functional theory and kinetic Monte Carlo methods. It is found that NiH is extremely short-lived and, thus, cannot promote coarsening in the SOC. Also, the diffusion of Ni on Ni(111) is shown to be at most slightly accelerated by H along NiH dissociation paths involving the movement of Ni with a nearby H. Based on this result, coarsening is not likely to be dramatically accelerated by the diffusion of Ni with H on Ni(111). However, support is provided for the experimental procedure of measuring the product of surface coverage and single-species diffusivity of Ni on Ni(111) in a hydrogen-rich atmosphere.

Ni coarsening↗

Reliability Issues with PME and BME Ceramic Capacitors

This work is a review of reliability issues specific for low-voltage precious metal electrode (PME) and base metal electrode (BME) multilayer ceramic capacitors (MLCC). A special attention is given to degradation and failures in capacitors with defects, in particular with cracks. Temperature and voltage reliability acceleration factors have been calculated based on approximation of distributions of degradation rates of leakage currents using a general log-linear Weibull model. Results show a substantial difference in behavior of BME and PME capacitors with defects. Mechanisms of degradation and failures in humid and dry environments and risks of overstressing capacitors during highly accelerated life testing (HALT) are discussed.

Teverovsky, Alexander↗