Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A co-axial electron gun to generate millimeter-wave RF using the two-stream instability

A novel source for broadband millimeter-wave RF is being designed at Los Alamos National Laboratory utilizing the two-stream instability. This RF source offers the potential for consistent output power over a large bandwidth on a single device. The source is designed to use two co-axial electron beams coupled into solenoidal magnetic fields. This is accomplished using two cathodes independently modulated nested in each other. The electron beam energy from the innermost cathode will fall in the range between 15 and 20 keV with the beam energy from the outer cathode being 75%–95% of the inner beam energy. In order to efficiently match the beam from the outer cathode into the solenoidal magnetic field, shields are used around the cathodes to shape the electric field in the gun region to extend the electrostatic focal length of the beams for better coupling into the magnetic field. As a result, we present the design of electron guns and expected performance using Trak simulations.

47 OTHER INSTRUMENTATION↗

RFA Measurement of E-Cloud Generation Process at Fermilab Main Injector

Fermilab aims to provide greater beam power for the neutrino physics program. As the beam power increases, the unwanted production of secondary electrons in the beam pipe, known as ‘electron cloud’ or ‘E-cloud’ may become disruptive to high intensity operation. Instrumentation has been deployed in the Fermilab Main Injector (MI) to study E-cloud. One of these is a Retard Field Analyzer (RFA) that can be used to directly measure E-cloud generation at the location of the instrument. Studies of the dependence of E-cloud on beam intensity and bunch length have been carried out. The experimental results are compared to POSINST simulations. These simulations are guided by measurements from a Secondary Electron Yield (SEY) test stand installed in the MI to measure the SEY of materials such as the beam pipe stainless steel. The SEY has a strong influence on the E-cloud density. Results of these comprehensive studies comparing the RFA data with realistic MI simulations will be presented.

43 PARTICLE ACCELERATORS↗

Filamentation and focusing of electron beams due to interactions with plasma waves

Results of numerical modeling of the interaction of an electron beam propagating across relativistic plasma waves indicate that electron beam filamentation and focusing may occur under certain conditions. The model is based on solving the relativistic equation of motion in three dimensions for the individual electrons in a tenuous Gaussian beam, as they pass through a relativistic plasma wave. Several electron beam and plasma wave parameters were varied, and the results are summarized. One of the results is that the spacing of the electron beam filaments correlates with the wavelength of the plasma wave. The electron beam filaments appear as vertical slabs after the beam exits the plasma waves. The electron beam also compresses to a focus after it exits the plasma, and the focal distance depends on several parameters including the electron beam energy and phase velocity of the relativistic plasma wave. It is suggested that these focusing and filamentation phenomena may be the basis for diagnostics schemes for laser plasma interactions. The parameters used in the model were electron beam energies in the 5–50 keV range and plasma wave properties typical for the beat-wave produced by CO2 lasers, which correspond to the facilities available in our laboratory. The limitations of these results to lower energy density beam and plasma regimes and to higher energy density regimes will be discussed.

47 OTHER INSTRUMENTATION↗

The NEWS-G detector at SNOLAB

The New Experiments With Spheres-Gas (NEWS-G) collaboration intends to achieve sub-GeV/c 2 Weakly Interacting Massive Particles (WIMPs) detection using Spherical Proportional Counters (SPCs). SPCs are gaseous detectors relying on ionisation with a single ionization electron energy threshold. The latest generation of SPC for direct dark matter searches has been installed at SNOLAB in Canada in 2021. This article details the different processes involved in the fabrication of the NEWS-G experiment. Also outlined in this paper are the mitigation strategies, measurements of radioactivity of the different components, and estimations of induced background event rates that were used to quantify and address detector backgrounds.

47 OTHER INSTRUMENTATION↗

Time Projection Chamber (TPC) detectors for nuclear astrophysics studies with gamma beams

Gamma-Beams at the HIS facility in the USA and anticipated at the ELI-NP facility, now constructed in Romania, present unique new opportunities to advance research in nuclear astrophysics; not the least of which is resolving open questions in oxygen formation during stellar helium burning via a precise measurement of the 12C() reaction. Time projection chamber (TPC) detectors operating with low pressure gas (as an active target) are ideally suited for such studies. We look over the progress of the current research program and plans for the future at the HIS facility with the optical readout TPC (O-TPC) and the development of an electronic readout TPC for the ELI-NP facility (ELITPC).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-dimensional correlation analysis for x-ray photoelectron spectroscopy

Abstract X-ray photoelectron spectroscopy (XPS) measures the binding energy of core-level electrons, which are well-localised to specific atomic sites in a molecular system, providing valuable information on the local chemical environment. The technique relies on measuring the photoelectron spectrum upon x-ray photoionisation, and the resolution is often limited by the bandwidth of the ionising x-ray pulse. This is particularly problematic for time-resolved XPS, where the desired time resolution enforces a fundamental lower limit on the bandwidth of the x-ray source. In this work, we report a novel correlation analysis which exploits the correlation between the x-ray and photoelectron spectra to improve the resolution of XPS measurements. We show that with this correlation-based spectral-domain ghost imaging method we can achieve sub-bandwidth resolution in XPS measurements. This analysis method enables XPS for sources with large bandwidth or spectral jitter, previously considered unfeasible for XPS measurements.

47 OTHER INSTRUMENTATION↗

An Open-Cell Environmental Transmission Electron Microscopy Technique for In Situ Characterization of Samples in Aqueous Liquid Solutions

The desire to image specimens in liquids has led to the development of open-cell and closed-cell techniques in transmission electron microscopy (TEM). The closed-cell approach is currently more common in TEM and has yielded new insights into a number of biological and materials processes in liquid environments. The open-cell approach, which requires an environmental TEM (ETEM), is technically challenging but may be advantageous in certain circumstances due to fewer restrictions on specimen and detector geometry. Here, we demonstrate a novel approach to open-cell liquid TEM, in which we use salt particles to facilitate the in situ formation of droplets of aqueous solution that envelope specimen particles coloaded with the salt. This is achieved by controlling sample temperature between 1 and 10°C and introducing water vapor to the ETEM chamber above the critical pressure for the formation of liquid water on the salt particles. Our use of in situ hydration enables specimens to be loaded into a microscope in a dry state using standard 3 mm TEM grids, allowing specimens to be prepared using trivial sample preparation techniques. Furthermore, our future aim will be to combine this technique with an in situ light source to study photocorrosion in aqueous environments.

47 OTHER INSTRUMENTATION↗

Development of slurry targets for high repetition-rate x-ray free electron laser experiments

Combining an x-ray free electron laser with a high-power laser driver enables the study of equations-of-state, high strain-rate deformation processes, structural phase transitions, and transformation pathways as a function of pressure to hundreds of GPa along different thermodynamic compression paths. Future high repetition-rate laser operation will enable data to be accumulated at >1 Hz, which poses a number of experimental challenges, including the need to rapidly replenish the target. Here, we present a combined shock compression and an x-ray diffraction study on epoxy (50% vol.)-crystalline grains (50% vol.) slurry targets, which can be fashioned into extruded ribbons for high repetition-rate operation. For shock-loaded NaCl-slurry samples, we observe pressure, density, and temperature states within the embedded NaCl grains consistent with observations from shock-compressed single-crystal NaCl.

47 OTHER INSTRUMENTATION↗

Experimental demonstration of attosecond pump–probe spectroscopy with an X-ray free-electron laser

Pump–probe experiments with subfemtosecond resolution are the key to understanding electronic dynamics in quantum systems. Here we demonstrate the generation and control of subfemtosecond pulse pairs from a two-colour X-ray free-electron laser. By measuring the delay between the two pulses with an angular streaking diagnostic, we characterize the group velocity of the X-ray free-electron laser and show control of the pulse delay down to 270as. Here, we confirm the application of this technique to a pump–probe measurement in core-ionized para-aminophenol. These results reveal the ability to perform pump–probe experiments with subfemtosecond resolution and atomic site specificity.

47 OTHER INSTRUMENTATION↗

Exploration of Optimizing FPGA-based Qubit Controller for Experiments on Superconducting Quantum Computing Hardware

This work explores avenues and target areas for optimizing FPGA-based control hardware for experiments conducted on superconducting quantum computing systems and serves as an introduction to some of the current research at the intersection of classical and quantum computing hardware. With the promise of building larger-scale error-corrected quantum computers based on superconducting qubit architecture, innovations to room-temperature control electronics are needed to bring these quantum realizations to fruition. The QICK (Quantum Instrumentation Control Kit) is one leading experimental FPGA-based implementations. However, its integration into other experimental quantum computing architectures, especially those using superconducting radiofrequency (SRF) cavities, is largely unexplored. We identify some key target areas for optimizing control electronics for superconducting qubit architectures and provide some preliminary results to the resolution of a control pulse waveform. With optimizations targeted at 3D superconducting qubit setups, we hope to bring to light some of the requirements in classical computational methodologies to bring out the full potential of this quantum computing architecture, and to convey the excitement of progress in this research.

43 PARTICLE ACCELERATORS↗

An ultra-compact x-ray free-electron laser

In the field of beam physics, two frontier topics have taken center stage due to their potential to enable new approaches to discovery in a wide swath of science. These areas are: advanced, high gradient acceleration techniques, and x-ray free electron lasers (XFELs). Further, there is intense interest in the marriage of these two fields, with the goal of producing a very compact XFEL. In this context, recent advances in high gradient radio-frequency cryogenic copper structure research have opened the door to the use of surface electric fields between 250 and 500 MV m -1 . Such an approach is foreseen to enable a new generation of photoinjectors with six-dimensional beam brightness beyond the current state-of-the-art by well over an order of magnitude. This advance is an essential ingredient enabling an ultra-compact XFEL (UC-XFEL). In addition, one may accelerate these bright beams to GeV scale in less than 10 m. Such an injector, when combined with inverse free electron laser-based bunching techniques can produce multi-kA beams with unprecedented beam quality, quantified by 50 nm-rad normalized emittances. The emittance, we note, is the effective area in transverse phase space (x, p x /m e c) or (y, p y /m e c) occupied by the beam distribution, and it is relevant to achievable beam sizes as well as setting a limit on FEL wavelength. These beams, when injected into innovative, short-period (1–10 mm) undulators uniquely enable UC-XFELs having footprints consistent with university-scale laboratories. We describe the architecture and predicted performance of this novel light source, which promises photon production per pulse of a few percent of existing XFEL sources. We review implementation issues including collective beam effects, compact x-ray optics systems, and other relevant technical challenges. To illustrate the potential of such a light source to fundamentally change the current paradigm of XFELs with their limited access, we examine possible applications in biology, chemistry, materials, atomic physics, industry, and medicine—including the imaging of virus particles—which may profit from this new model of performing XFEL science.

47 OTHER INSTRUMENTATION↗

Rethinking Coherent Diffraction Instruments for High Brightness Sources

Over the past two decades, exceptional progress has been made providing coherent x-ray beams at both high-brightness synchrotron sources and x-ray free electron lasers (XFEL). The availability of these coherent x-rays has led to a surge in instruments that exploit x-ray coherence for either x-ray photon correlation spectroscopy (XPCS) or coherent diffraction imaging (CDI). A key to these techniques has been to resolve, or at least nearly resolve, the speckles associated with the scattering from structural disorder. Given practical limits on detector pixel size, this requires long sample-to-detector distances. This paper presents numerical simulations of an instrument that can efMiciently provide a long sample-detector distance while maintaining the ability to rapidly set momentum transfer by inserting crystals with different order in the incident beam, thus changing in incident direction instead of moving the detector.

Fuoss, Paul H↗

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam↗

A LArTPC with Vertical Drift for the DUNE Far Detector

The Far Detector of the Deep Underground Neutrino Experiment (DUNE) will be a large LArdetector located at a baseline of 1300 kilometers, 1.5 km deep underground. It is planned to bemade up of four modules, each with a total mass of 17 kt of LAr, at least the first two of which willconsist in Liquid Argon Time Projection Chambers (LArTPCs). To prove the feasibility of theLArTPC technology at the kiloton scale, the ProtoDUNE Single and Dual-Phase detectors wereconstructed and operated at the CERN Neutrino facility.This document describes the Vertical Drift detector concept, which is proposed to instrument thesecond DUNE module. It consists of a TPC where the electrons drift vertically, with a cathodesuspended at mid-height, towards anodes placed at the bottom and top of the detector. The anodeswould be made out of printed PCBs instead of wires, and the new disposition would allow the topreadout electronics to be accessible during the lifetime of the experiment. An enhanced photo-detection system is also proposed, with the photo-sensors placed on the cryostat walls and thecathode, but posing a challenge in terms of power and signal transmission. Studies are ongoingboth to overcome the technical challenges of this new design and to finalize the concept.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron density measurement using a partially covered hairpin resonator in an inductively coupled plasma

Hairpin probes are used to determine electron densities via measuring the shift of the resonant frequency of the probe structure when immersed in a plasma. This manuscript presents new developments in hairpin probe hardware and theory that have enabled measurements in a high electron density plasma, up to approximately 10 12 cm -3 , corresponding to a plasma frequency of about 9 GHz. Hardware developments include the use of both quarter-wavelength and three-quarter-wavelength partially covered hairpin probes in a transmission mode together with an easily reproducible implementation of the associated microwave electronics using commercial off-the-shelf components. The three-quarter-wavelength structure is operated at its second harmonic with the purpose of measuring higher electron densities. New theory developments for interpreting the probe measurements include the use of a transmission line model to find an accurate relationship between the resonant frequency of the probe and the electron density, including effects of partially covering the probes with epoxy. Measurements are taken in an inductively coupled plasma sustained in argon at pressures below 50 mTorr. Results are compared with Langmuir probe and interferometry measurements.

47 OTHER INSTRUMENTATION↗

The 6-minute walk test predicts mortality in a pulmonary nontuberculous mycobacteria-predominant bronchiectasis cohort

Background: Bronchiectasis is a chronic lung condition frequently associated with nontuberculous mycobacteria pulmonary (NTM) disease. Persons with these conditions are at increased risk of mortality. Patient reported outcome (PRO) instruments and the 6-minute walk test (6MWT) have been shown to predict mortality for several lung conditions, but these measures have not been fully evaluated for bronchiectasis and NTM. Methods: We conducted a retrospective cohort study among adult patients enrolled in a natural history study of bronchiectasis at the National Heart, Lung, and Blood Institute. Electronic medical records were queried for demographic, clinical, microbiologic, radiographic, and PRO instrument data: St. George’s Respiratory Questionnaire (SGRQ), Medical Research Council Dyspnea Scale, and the Pulmonary Symptom Severity Score (PSSS). The study baseline date was defined as the patient’s first visit after January 1st, 2015 with a SGRQ or 6MWT completed. Follow-up was defined as the interval between the study baseline visit and date of death or December 31st, 2019. Sex-stratified Cox proportional-hazards regression was conducted to identify predictors of mortality. Separate models were run for each PRO and 6MWT measure, controlling for age, body mass index (BMI), fibrocavitary disease status, and M. abscessus infection. Results: In multivariable Cox proportional-hazards regression models, the PSSS-severity (aHR 1.29, 95% CI 1.04–1.59), the 6MWT total distance walked (aHR 0.938, 95% CI 0.896–0.981) and distance saturation product (aHR 0.930, 95% CI 0.887–0.974) independently predicted mortality. In addition, BMI was significantly predictive of mortality in all models. Conclusions: The 6MWT and a PRO instrument capturing symptom severity are independently predictive of mortality in our cohort of bronchiectasis patients.

6-minute walk test↗

X-ray free-electron laser wavefront sensing using the fractional Talbot effect

Wavefront sensing at X-ray free-electron lasers is important for quantitatively understanding the fundamental properties of the laser, for aligning X-ray instruments and for conducting scientific experimental analysis. A fractional Talbot wavefront sensor has been developed. This wavefront sensor enables measurements over a wide range of energies, as is common on X-ray instruments, with simplified mechanical requirements and is compatible with the high average power pulses expected in upcoming X-ray free-electron laser upgrades. Single-shot measurements were performed at 500 eV, 1000 eV and 1500 eV at the Linac Coherent Light Source. These measurements were applied to study both mirror alignment and the effects of undulator tapering schemes on source properties. The beamline focal plane position was tracked to an uncertainty of 0.12 mm, and the source location for various undulator tapering schemes to an uncertainty of 1m, demonstrating excellent sensitivity. These findings pave the way to use the fractional Talbot wavefront sensor as a routine, robust and sensitive tool at X-ray free-electron lasers as well as other high-brightness X-ray sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development and Application of In Situ Nanocharacterization to Photocatalytic Materials for Solar Fuel Generation

Photocatalytic materials offer an attractive approach for converting solar energy into chemical energy but the performance of the current generation of materials is insufficient to make a technology viable. To address this deficiency, it is necessary to develop a fundamental atomic level understanding of the functioning of such materials so that strategies can be developed to improve performance. This project was undertaken to explore the fundamental structure and properties of photocatalytic materials using atomic resolution imaging and spectroscopy techniques available on advanced transmission electron microscopy. Specifically, there is a need to develop an understanding of how atomic structures/defects and nanoparticle configurations regulate electronic, optical, and catalytic properties to facilitate the design of next generation photocatalysts for solar fuel production. The work focused on fundamental materials information that can be gained from advanced transmission electron microscopy study on novel and existing photocatalytic systems with an emphasis on the hydrogen evolution reaction (HER). Throughout the project, new instrumentation and microscopy characterization tools were developed. Two focus areas were: developing in situ TEM methods and advanced electron energy-loss spectroscopic for nanoscale analysis of catalysts. The work spanned a period of 12 years and for convenience, the report is divided into four phases, approximately corresponding to the four funding periods of the program. Most of the significant results are reported in archival journal publications.

36 MATERIALS SCIENCE↗