Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron irradiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Influence of metal ion complexation on the radiolytic longevity of butyramide extractants under direct dissolution conditions

The direct dissolution of volox-treated used nuclear fuel (UNF) into an organic solution—comprised of diluent and specialized extractants—poses a promising alternative to the traditional liquid-liquid solvent extraction approach to reprocessing UNF. However, moving to direct dissolution removes the presence of a concentrated nitric acid aqueous phase, which has been shown to significantly influence the radiolytic longevity of extractants in liquid-liquid solvent extraction flowsheets. With this in mind, and given the limited knowledge of radiation effects under direct dissolution conditions, we present a time-resolved and dose accumulation study on the impact of direct dissolution conditions on the radiolytic longevity of two candidate butyramide extractants—N,N-di-(2-ethylhexyl) butyramide (DEHBA) and N,N-di-(2-ethylhexyl)isobutyramide (DEHiBA)—in pre-equilibrated n-dodecane solvent in the presence and absence of process relevant metal ions, uranium and rhenium. Rhenium, and by extension technetium, extraction had little impact (=10%) on the overall radiolytic stability of these ligands, despite observed increases in chemical kinetic reactivity (>2×) of the corresponding complexes with the n-dodecane radical cation. Uranium-loading on the other hand, significantly improved the lifetime of both ligands (>30%) under gamma irradiation, with a greater stabilization observed for DEHBA over DEHiBA. This draft manuscript has been prepared in fulfillment of NTRD-MRWFD-2024 M3FT-24IN030101115.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Comparative characterization of mixed spectra and thermal neutron shielded irradiated tungsten

The effect of mixed spectra and thermal neutron shielded irradiation on tungsten was evaluated with plasma exposure in the tritium plasma experiment followed by thermal desorption spectroscopy, X-ray photoelectron spectroscopy, and transmission electron microscopy. The two different irradiation campaigns were performed at the High Flux Isotope Reactor to 0.39–0.74 displacement per atom (dpa) in the 894–1379 K temperature range. A neutron spectrum influence on the void size and void number density was not observed. However, a strong correlation was found between void size and void number density with temperature, but not with dpa in the limited dpa range of this study. Thermal neutron shielding significantly reduced the transmutation to Re+Os. Higher irradiation temperature will lead to larger voids with lower number density, which reduces deuterium retention. In conclusion, grain growth was also observed for high-temperature irradiation of over ~1300 K within the limited grains visible in the transmission electron microscopy specimens.

36 MATERIALS SCIENCE↗

High-Resolution Three-Dimensional Sculpting of Two-Dimensional Graphene Oxide by E-Beam Direct Write

On demand switchable additive/subtractive patterning of 2D nanomaterials is an essential capability for developing new concepts of functional nanomaterials and their device realizations. Traditionally, this is performed via a multi-step process using photoresist coating and patterning by conventional photo or electron beam lithography, which is followed by bulk dry/wet etch or deposition. This limits the range of functionalities and structural topologies that can be achieved, as well as increases the complexity, cost, and possibility of contamination which are significant barriers to device fabrication from highly sensitive 2D materials. Focused electron beam induced processing (FEBIP) enables a material chemistry/site-specific, high-resolution multi-mode atomic scale processing and provides unprecedented opportunities for direct-write, single-step surface patterning of 2D nanomaterials with an in-situ imaging capability. It allows for realizing a rapid multi-scale/multi-mode approach, ranging from an atomic scale manipulation (e.g., via targeted defect introduction as an active site) to a large-area surface modification on nano and micro scales, including patterned doping and material removal/deposition with 2D (in-plane)/3D (out-of-plane) control. In this work, we report on a new capability of FEBIP for nanoscale patterning of graphene oxide via removal of oxygenated carbon moieties with no use of reactive gas required for etching complemented by carbon atom deposition using focused electron beam. The mechanism of experimentally observed phenomena is explored using the density functional theory (DFT) calculations, revealing that interactions of e-beam liberated reactive oxygen radicals with carbon atoms on graphene basal plane lead to creation of atomic vacancies in the material. The reaction by-products are volatile carbon di-oxides, which are dissociated and volatilized from the graphene oxide surface functional groups by interactions with an energetic focused electron beam. Along with selective “subtractive” patterning of graphene oxide, the same electron beam with increased irradiation doses can deposit out-of-plane 3D carbon nanostructures on top of or around the 2D etched pattern, thus forming a hybrid 2D/3D nanocomposite with feature control down to a few nanometers. Furthermore, this in-operando dual nanofabrication capability of FEBIP is unmatched by any other nanopatterning techniques and opens a new design window for forming 2D/3D complex nanostructures and functional nanodevices.

36 MATERIALS SCIENCE↗

Evolution of extended defects in UO 2 during high temperature annealing

The evolution of thermophysical characteristics of uranium oxide (UO 2 ) under irradiation is a critical aspect of nuclear fuel performance of light water reactors. This study examines the effect of high-temperature annealing at 1000 °C - 1600 °C on defect evolution in krypton irradiated UO 2 at room temperature. Transmission electron microscopy analysis reveals that the size of irradiation-induced bubbles and dislocation loops increases but their density decreases with annealing temperatures. Perfect dislocation loops with = <110> dominate, regardless of the annealing temperature. A rate theory model for extended defect evolution is applied to conclude that current understanding of dynamical loop and bubble evolution at high-temperature annealing is governed by defect coalescence.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Flow Induced Vibration Studies in Pressurized Helium Gas Cooling Channels

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process. During irradiation, pressurized helium gas flows through 0.25 mm thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo-100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Longer duration testing will provide more data and verification for the findings presented in this report. The work will be continued in FY 24.

43 PARTICLE ACCELERATORS↗

Window Cooling Studies and Disk Vibration Testing on a Subset of Mo-100 Disks

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless-steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process, with a smaller percentage adding up to 2.2 kW of heat deposited on the Inconel window. During irradiation, pressurized helium gas flows through thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo 100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. LANL has previously also tested NMR’s Inconel beam window by heating the window, while flowing pressurized helium, using the average heat deposited on the window. However, the NMR beam is pulsed with a duty cycle of 12.5%, which introduces oscillation in temperature around the nominal 600 °C steady state value with each pulse. Available fatigue curves for Inconel are few, established for room temperature, and they are based on mechanical strain cycles not thermally induced strain as in the NMR target. The effect of pulsed beam heating on the Inconel window therefore needs to be quantified. This report details the experiments conducted to assess the factors that lead to mass loss in the NMR target disks as well as to understand the effect of a pulsed beam on NMR’s Inconel window. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 5 to 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Improved target holders significantly reduce disk mass loss to almost negligible quantities. This work finds that the larger window to first disk gap and improved target holder geometry should allow NMR to successfully conduct irradiations with minimal mass loss. The window tests were conducted to understand the effect of a pulsed beam on both the window longevity and to estimate the window temperature and displacement during pulsing. The experiments presented here were performed at significantly low power, due to the limitations of the induction heating system. The window temperature rose to approximately 73 °C with a significantly reduced power of 45 W without beam pulsing. With a 5 Hz pulse rate, 12.5% duty cycle, the window temperature remained constant at 26 °C. These experiments will be repeated with improved coil geometry and reported in upcoming journal papers.

42 ENGINEERING↗

Radiation Stability of Mixed Tin-Lead Halide Perovskites: Implications for Space Applications

Mixed organic-inorganic halide perovskite solar cells (PSCs) have received considerable attention in recent years for their impressive solar to electrical power efficiency gains and potentially lower material and processing costs for optoelectronic applications. In addition to terrestrial applications, PSCs are of interest to the space power markets for their low cost, low weight, adaptability to flexible architectures, and tolerance to high energy particle irradiation (mainly protons and electrons). Here we investigate the properties of mixed formamidinium-methylammonium tin-lead iodide (FASn)0.6(MAPb)0.4I3 perovskites which lower the lead content as well as the bandgap, making them attractive for the low bandgap absorber material in tandem PSCs. Through current density-voltage (JV) characterization at lower temperatures, majority carrier transport is hindered and a barrier to photogenerated carrier extraction is evident. This is attributed to the thermally induced change of the bandgap of the absorber layer relative to the energy selective contacts in the device. We find that although the architecture used here hinders the performance at temperatures below 225 K, the tolerance to high energy (3.7 MeV) protons is impressive, considerably out-performing commercially available thin-film CIGS. These results suggest further improvements to structural and interface stability as well as lightweight encapsulation could lead to all perovskite flexible tandem arrays deployed for power generation on missions to low Earth orbit, the moon, Mars, and beyond.

perovskite solar cells↗

Proton radiation resilience of CdSeTe photovoltaics: High predicted end-of-life performance for space applications

Two types of cadmium selenide telluride (CdSeTe) photovoltaic devices have been exposed to high-energy (150–1500 keV) protons with fluences ranging from 1 × 10 11 to 9 × 10 13 cm −2 . Pre- and post-irradiation current density vs voltage characteristic data were collected and analyzed. Arsenic-doped CdSeTe devices retained 80% of the power conversion efficiency (PCE) relative to control devices after exposure to 10 12 cm −2 650 keV protons, while copper-doped CdSeTe devices retained about 95% of the control PCE under the same irradiation condition. Displacement damage dose analysis coupled with simulations for duration-dependent performance in a medium Earth orbit space mission revealed superior PCE remaining factors, indicating greater resilience to proton bombardment than state-of-the-art multijunction III-V based space photovoltaic technologies.

CdTe solar cells↗

Flow Measurements in Pressurized Helium Gas Cooling Channels

Production of metastable Technetium-99 (Tc-99m) is vital to the medical imaging community. It is a radioactive tracer that emits gamma rays as it decays and it is these gamma rays that are then detected through imaging. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. One method of generating Mo-99 is using accelerator based technology, through the irradiation of Mo-100 using an electron beam. This is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar medical Radioisotopes (NMR) on their efforts to produce Mo-99 from the irradiation of Mo-100 targets. The NMR target consists of an Inconel window that allows the electron beam to penetrate and irradiate a stack of Mo-100 discs. The irradiation process generates large amounts of heat and requires extensive cooling of the Mo-100 targets and target housing using pressurized helium gas. Before beam on target, the design of the target stack and target housing is tested at LANL using laser based diagnostics experiments. We quantify the velocity field of the helium gas around the target housing to estimate whether the cooling provided is sufficient for the design and to validate computational fluid dynamics (CFD) models. Fiber optic imaging is also developed for use during cold testing (without beam on target) as well as during irradiation, to obtain real time information on disc performance.

07 ISOTOPE AND RADIATION SOURCES↗

Electronic stopping in molecular dynamics simulations of cascades in 3C–SiC

Here, we investigate the effect of the electronic stopping power on defect production due to ion irradiation of cubic silicon carbide using molecular dynamics simulations. We simulate 20 keV and 30 keV Si and C ions, with and without the electronic energy loss. The results show that the electronic stopping effects are more profound in the case of C irradiation, where the ratio of the electronic energy loss S e to the nuclear energy loss S n is much larger compared to the ratio for Si ions. These findings indicate that this ratio plays a role in the effect of the electronic stopping on ion irradiation.

36 MATERIALS SCIENCE↗

In-situ microstructure observation of oxidized SiC layer in surrogate TRISO fuel particles under krypton ion irradiation

In accidental scenarios of high temperature gas-cooled reactors, both oxidation of and irradiation to the SiC layer in tri-structural-isotropic (TRISO) fuel particles can change the microstructure and integrity of the fuel elements. Here, in the present study, microstructure and defect evolution in the oxidized SiC layer of surrogate TRISO fuel particles under 1.2 MeV krypton ion irradiation was observed by in-situ transmission electron microscopy. The SiC layers oxidized in water vapor at 1200 °C were irradiated azt room temperature and 800 °C and at damage levels of 0.28–11.2 dpa, respectively. SiC and SiO 2 were found to still be in their crystal structures at the damage level of 11.2 dpa at 800 °C, while SiC was observed to have been amorphized at only 0.56 dpa irradiation at room temperature. The defect number density at 800 °C was an order of magnitude lower than that in the sample irradiated at room temperature. Also, crystalline SiO 2 had higher radiation resistance compared to SiC. A defect reaction rate theory was utilized to understand the fundamental defect evolution process and irradiation resistance difference.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Understanding and quantifying electron beam effects during in situ TEM nanomechanical tensile testing on metal thin films

Transmission electron microscopy (TEM) imaging relies on high energy electrons for atomic scale resolution, however, the electrons themselves interact with and may alter the material being imaged. Using an in situ TEM MEMS-based nanomechanical testing technique, the effect of the electron beam (e-beam) on the deformation behavior of nanocrystalline Al and ultrafine-grained Au is investigated and quantified. We show that the e-beam enhances plastic deformation, leading to an increase in plastic strain rate and a decrease in true activation volume V* in Al (28 to 21b 3 , with b being the Burgers vector length). The e-beam has a much weaker effect on Au. The e-beam effect is not caused by knock-on damage, but rather an effective temperature increase due to additional atomic fluctuations provided by the e-beam. The effective temperature increase is larger for Al than Au. This e-beam effect does not change the deformation mechanisms, but instead accelerates the stress-driven, thermally activated plastic deformation. These experiments provide insight into the effects of the e-beam on plastic deformation in different metals and underscore the importance of understanding and quantifying these effects for proper interpretation of measured mechanical properties during in situ TEM experiments.

36 MATERIALS SCIENCE↗

Application of a deep learning semantic segmentation model to helium bubbles and voids in nuclear materials

Imaging nanoscale radiation-induced defects using the transmission electron microscope (TEM) is a key factor in the successful implementation of materials for nuclear energy structural applications. Analyzing each defect in a TEM micrograph is currently a manual task. To identify the defects in a single image can take anywhere from 15 min to an hour and a project can require the analysis of anywhere from tens to ≥ 100 images. Here, we use artificial intelligence (AI) models to automate this task. For simplification, we evaluated images with only a single type of defect; helium bubbles. Additionally, we performed semantic segmentation of these helium bubble defects in electron microscopy images of irradiated FeCrAl alloys using a deep learning DefectSegNet model. This model, which was previously used to classify crystal defects, is inspired by the classic DenseNet and U-Net image segmentation models. It claims high spatial resolution, but has poor performance at object boundaries. Our paper improves the DefectSegNet model’s application by adding two new features. First, the DefectSegNet model is applied not only to perform calculation pixel-wise but also object (or feature) wise. Because object-wise metrics are directly relevant to our final goal of detecting bubbles, whereas pixel-wise classification is only an intermediate step, it is an important part of our study. Second, a distance map loss (DML) function has been added to increase its performance at object boundaries. It is crucial to accurately represent defects boundaries, especially bubbles, in order to track the bubble-induced swelling caused by irradiation. The boundary-focused DML function is also compared to other loss functions like Cross-entropy, Weighted Binary Cross Entropy (WBCE), Dice and Intersection over Union (IOU). Finally, by incorporating new features, we found a marked improvement on segmentation quality and better shape preservation at the boundaries and areas of the bubbles.

42 ENGINEERING↗

Microstructure evolution in U-10Zr alloy irradiated by swift Xe ions at 700 °C

The post-irradiation examination (PIE) results of U-10Zr binary metallic fuel that was irradiated by 84 MeV Xe ions at 700 °C are reported here. The U-10Zr specimen was synthesized by homogenizing elemental U and Zr powders through arc-melting. The as-fabricated U-10Zr was dominated by the sub-micron acicular α+ δ phase. After being irradiated by 84 MeV Xe ions at 700 °C up to 2.19 ×10 17 ions/cm 2 fluence, the U-10Zr was speculated to evolve into micro-scale γ 1 + γ 2 phases as predicted by the U-Zr phase diagram. During post-irradiation cooling, the U-rich γ 1 phase was mainly transformed to the αphase, while the Zr-rich γ 2 phase was partially retained along with formation of hexagonal structure phase (δ or ω). Xe bubbles formed in the γ 1 and γ 2 phases have salient different morphologies, implying faster Xe diffusion in the γ 1 phase than the γ 2 phase. The quantitative bubble morphology data collected in this study can provide valuable references for the development and validation of fuel performance models for this fuel.

36 MATERIALS SCIENCE↗

Microstructure investigations of temperature effect on Al-UMo diffusion couples irradiated by swift Xe ions

Post-irradiation examination (PIE) results of microstructure in irradiated Al-UMo diffusion couples are reported here. These diffusion couples were irradiated by 60 MeV Xe ions at four different temperatures up to approximately 5.5 × 10 17 ions/cm 2 peak ion fluence. An Al-UMo interaction layer (IL) was found to form at all four investigated temperatures. The IL is homogeneously amorphous when formed up to 150 °C. At 215 °C, the (U,Mo)Al 3 nanocrystalline precipitates form within the amorphous IL matrix. Kirkendall voids with prominent temperature dependence were observed in both the Al layer and its interface with the IL. On the other hand, Xe bubbles were found to form in UMo and Al-UMo IL with different morphology. These microstructure features were quantitatively measured and are reported to provide valuable references for understanding the irradiation behavior of UMo/Al dispersion fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of radiation damage in 3D printed SiC

The SiC fuel matrix for advanced gas-cooled high temperature reactors as part of the Transformational Challenge Reactor program serves as the fuel particle container structure, a barrier to fission gas release, and a heat transfer medium. Its performance is particularly important because the fuel matrix must demonstrate good structural stability and thermal behaviors. An additive manufacturing methodology combining a binder jet 3D printing process with chemical vapor infiltration (CVI) for the production of SiC was recently developed. In this study, post irradiation examination by transmission electron microscopy shows that defect accumulation within the printed particles is very similar to other forms of high-purity SiC. However, damage accumulation was not directly observed in the CVI matrix because black spot damage and dislocation loops are difficult to image within the nanoscale highly faulted CVI matrix and because interstitial defects may rapidly annihilate at the stacking faults. Therefore, electron energy loss spectroscopy (EELS) analysis was used to analyze defect swelling in both the printed particles and the CVI matrix. The EELS analysis helped reveal that the radiation-induced swelling in the CVI matrix is similar to that of the printed SiC particles. This work shows that 3D printed SiC has behavior that is comparable to SiC processed by other means and that 3D printing could serve as a suitable processing technique for high-purity SiC for nuclear applications.

36 MATERIALS SCIENCE↗

X-ray induced grain boundary formation and grain rotation in Bi 2 Se 3

Optimizing grain boundary characteristics in polycrystalline materials can improve their properties. Many processing methods have been developed for grain boundary manipulation, including the use of intense radiation in certain applications. Here, in this work, we used X-ray free electron laser pulses to irradiate single-crystalline bismuth selenide (Bi 2 Se 3 ) and observed grain boundary formation and subsequent grain rotation in response to the X-ray radiation. Our observations with simultaneous transmission X-ray microscopy and X-ray diffraction demonstrate how intense X-ray radiation can rapidly change size and texture of grains.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kinetics of Radiation-induced Cr( II ) and Cr( III ) Redox Chemistry in Molten LiCl-KCl Eutectic

Chromium (Cr) is a frequent constituent of the metal alloys proposed for molten salt nuclear reactor (MSR) applications, and is typically the least noble metal ion present. Consequently, chromium is preferentially corroded into molten salt solutions. Here, the redox poise and redox cycling of chromium ions in the salt can greatly influence its corrosivity towards structural alloys, ultimately impacting the longevity of MSR systems. Radiation-induced chemistry is expected to play a significant role in determining the chromium oxidation state distribution during MSR operations. In the present research, electron pulse radiolysis techniques were employed to characterize the reactivity of Cr(II) and Cr(III) ions with primary radiolysis products in molten lithium chloride–potassium chloride (LiCl–KCl) eutectic over a temperature range of 400–600 °C. Both chromium oxidation states were found to rapidly react with the primary products of molten chloride salt radiolysis, i.e., the solvated electron (e S - ) and the dichlorine radical anion (Cl 2 ˙ - ). For reactions with the e S - , second-order rate coefficients (k) of k = (4.1 ± 0.2) and (6.1 ± 0.3) × 10 10 M -1 s -1 at 400 °C for Cr(II) and Cr(III), respectively, were determined. Temperature-dependent measurements allowed for the derivation of activation parameters for electron capture by Cr(II) and Cr(III). Both chromium ions also react with Cl 2 ˙ - , k = (7.2 ± 0.3) and (1.4 ± 0.1) × 10 9 M -1 s -1 at 400 °C for Cr(II) and Cr(III), respectively.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗