Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron linac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

FFA@CEBAF beam transport error and tolerance simulation studies

The Continuous Electron Beam Accelerator Facility (CEBAF) is a 12 GeV recirculating electron accelerator at the Thomas Jefferson National Accelerator Facility (JLAB). Major upgrades to the accelerator are being investigated which include a new 650 MeV injection beamline and state-of-the-art fixed-field alternating (FFA) gradient recirculation arcs. The upgrade will extend the energy of the electron beam to over 20 GeV. In this paper, we provide an error and tolerance simulation study of the amended beam optics transport of the existing accelerator tuned for 22 GeV operation. The study is conducted with the particle tracking codes elegant and Bmad in two parts. In the first part, we treat each section of the accelerator (electromagnetic arcs and linacs) modularly with ideal conditions at the beginning. The second part is a pseudo start-to-end (S2E) simulation with accumulated errors propagating from one beamline to the next.

Accelerator Physics↗

Observation of photo-induced plasmon–phonon coupling in PbTe via ultrafast x-ray scattering

We report the observation of photo-induced plasmon–phonon coupled modes in the group IV–VI semiconductor PbTe using ultrafast x-ray diffuse scattering at the Linac Coherent Light Source. We measure the near-zone-center excited-state dispersion of the heavily screened longitudinal optical (LO) phonon branch as extracted from differential changes in x-ray diffuse scattering intensity following above bandgap photoexcitation. We suggest that upon photoexcitation, the LO phonon-plasmon coupled (LOPC) modes themselves become coupled to longitudinal acoustic modes that drive electron band shifts via acoustic deformation potentials and possibly to low-energy single-particle excitations within the plasma and that these couplings give rise to displacement-correlations that oscillate in time with a period given effectively by the heavily screened LOPC frequency.

36 MATERIALS SCIENCE↗

Understanding the superconductivity and charge density wave interaction through quasi-static lattice fluctuations

In unconventional superconductors, coupled charge and lattice degrees of freedom can manifest in ordered phases of matter that are intertwined. In the cuprate family, fluctuating short-range charge correlations can coalesce into a longer-range charge density wave (CDW) order which is thought to intertwine with superconductivity, yet the nature of the interaction is still poorly understood. Here, by measuring subtle lattice fluctuations in underdoped YBa 2 Cu 3 O 6+y on quasi-static timescales (thousands of seconds) through X-ray photon correlation spectroscopy, we report sensitivity to both superconductivity and CDW. The atomic lattice shows remarkably faster relaxational dynamics upon approaching the superconducting transition at T c ≈ 65 K. By tracking the momentum dependence, we show that the intermediate scattering function almost monotonically scales with the relaxation distance of atoms away from their average positions above T c and in the presence of the CDW state, while this peculiar trend is reversed for other temperatures. These observations are consistent with an incipient CDW stabilized by local strain. This work provides insights into the crucial role of relaxational atomic fluctuations for understanding the electronic physics cuprates, which are inherently disordered due to carrier doping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correlation-driven attosecond photoemission delay in the plasmonic excitation of C60 fullerene

Extreme light confinement in plasmonic nanosystems enables novel applications in photonics, sensor technology, energy harvesting, biology, and quantum information processing. Fullerenes represent an extreme case for nanoplasmonics: they are sub-nanometer carbon- based molecules showing high-energy and ultrabroad plasmon resonances, however the fundamental mechanisms driving the plasmonic response and the corresponding collective electron dynamics are still elusive. Here, we uncover the dominant role of electron correlations in the dynamics of the giant plasmon resonance (GPR) of the sub-nanometer system C60 by employing attosecond photoemission chronoscopy. We find a characteristic photoemission delay of up to about 300 attoseconds that is purely induced by coherent large-scale electron correlations in the plasmonic potential. These results provide novel insights into the nature of the plasmon resonances in sub-nanometer systems and open new perspectives for advancing nanoplasmonic applications.

Biswas, Shubhadeep [SLAC National Accelerator Labo↗

Exploratory splitter bend system designs for FFA@CEBAF

An upgrade to the Continuous Electron Beam Accelerator Facility (CEBAF) at the Thomas Jefferson National Accelerator Facility (JLAB) is anticipated to provide an electron beam of over 20 GeV using the existing superconducting-RF linear accelerator and new fixed-field alternating (FFA) gradient recirculation arcs made up of Halbach-style permanent magnets. In the current design, the FFA arcs will carry six beams with energies of approximately 11, 13, 16, 18, 20, and 22 GeV which will require horizontal splitter lines to match the beam from the preceding linac. In this paper, we describe two alternative splitter beamline designs that are tuned to match the beam's Twiss parameters, R56, time-of-flight, bend-plane offset, and dispersion into the FFA cells.

Accelerator Physics↗

Geant4-based Analysis of Faraday Cup Performance for PIP-II Laser Wire Scanner System

The Proton Improvement Plan-II (PIP-II) accelerator upgrade at Fermilab marks a significant advancement in high-energy physics research. This initiative aims to enhance Fermilab's accelerator complex by replacing the existing linear accelerator (linac) with a warm front end (WFE) capable of accelerating H- beams up to 2.1 MeV. Subsequently, a superconducting linac (SCL), that further accelerates these beams up to 800 MeV. To accurately measure the transverse beam profile, traditional wire scanners will be utilized in the WFE section, while Laser wire scanners will be implemented along the SCL. The Faraday cup for the Laser wire scanners has been designed using the GEANT4 simulation toolkit. This poster presents a detailed analysis of its performance along the SCL, focusing on electron absorption, secondary electron emission, backscattering, etc.

Wijethunga, S. A.K.↗

Modular droplet injector for sample conservation providing new structural insight for the conformational heterogeneity in the disease-associated NQO1 enzyme

Droplet injection strategies are a promising tool to reduce the large amount of sample consumed in serial femtosecond crystallography (SFX) measurements at X-ray free electron lasers (XFELs) with continuous injection approaches. Here, we demonstrate a new modular microfluidic droplet injector (MDI) design that was successfully applied to deliver microcrystals of the human NAD(P)H:quinone oxidoreductase 1 (NQO1) and phycocyanin. We investigated droplet generation conditions through electrical stimulation for both protein samples and implemented hardware and software components for optimized crystal injection at the Macromolecular Femtosecond Crystallography (MFX) instrument at the Stanford Linac Coherent Light Source (LCLS). Under optimized droplet injection conditions, we demonstrate that up to 4-fold sample consumption savings can be achieved with the droplet injector. In addition, we collected a full data set with droplet injection for NQO1 protein crystals with a resolution up to 2.7 Å, leading to the first room-temperature structure of NQO1 at an XFEL. NQO1 is a flavoenzyme associated with cancer, Alzheimer's and Parkinson's disease, making it an attractive target for drug discovery. Further, our results reveal for the first time that residues Tyr128 and Phe232, which play key roles in the function of the protein, show an unexpected conformational heterogeneity at room temperature within the crystals. These results suggest that different substates exist in the conformational ensemble of NQO1 with functional and mechanistic implications for the enzyme's negative cooperativity through a conformational selection mechanism. Our study thus demonstrates that microfluidic droplet injection constitutes a robust sample-conserving injection method for SFX studies on protein crystals that are difficult to obtain in amounts necessary for continuous injection, including the large sample quantities required for time-resolved mix-and-inject studies.

59 BASIC BIOLOGICAL SCIENCES↗

Heat load measurements for the PIP-II pHB650 cryomodule

This study presents a brief overview of the 1st and 2nd phases and an in-depth analysis of the 3rd phase heat load testing performed on the pHB650 (prototype High Beta 650 MHz) cryomodule at PIP2IT (PIP-II Injector Test Facility), with a focus on both the results and the methodological advancements that have improved testing efficiency and accuracy. A key challenge identified in the testing campaign is the higher-than-expected heat loads observed in the first PIP-II (Proton Improvement Plan II) prototype cryomodules (pSSR1 and pHB650) tested at PIP2IT. Elevated heat loads are concerning given the fixed capacity of the PIP-II cryoplant that is currently being installed at Fermilab. However, understanding the sources of these elevated heat loads offers a critical opportunity to implement effective heat load mitigations on upcoming PIP-II cryomodules to stay within the available capacity of the PIP-II cryoplant. The study includes a summary of test results, descriptions of measurement procedures, and key observations on parameters directly and indirectly related to heat load measurements. Direct observations include measured heat loads and the effectiveness of JT heat exchanger under varying conditions, while indirect observation analyze factors such as the temperature distribution on the two-phase pipe and relief piping under varying conditions. Thermal acoustic oscillations (TAO) were identified during testing, which was mitigated by replacing the original G10 stem with a stainless steel stem equipped with wipers for the cryomodule cooldown valve. A major innovation during pHB650 Phase 3 testing was the development of an automated Python script to streamline data acquisition, analysis, and reporting of heat load results. This script automatically retrieved data from ACNET (Accelerator Control Network), performed heat load calculations, and generated detailed reports featuring plots and tables. This advancement significantly reduced manual labor and enhanced the thoroughness of data analysis compared to earlier campaigns. The heat load test reports were promptly uploaded to the electronic logbook shortly after each test, enabling rapid feedback and collaboration between the SRF and cryogenic teams. The heat load measurements included various components: HTTS (high-temperature thermal shield), LTTS (low-temperature thermal shield), 2K isothermal and non-isothermal heat loads. Results were recorded both within the cryomodule and between the bayonet can supply and return. Measurements were conducted under different operating conditions such as "standard", "linac", and "simulated dynamic". Additionally, HTTS and LTTS heat loads were calculated in real time, allowing for the tracking of thermal stability and identification of changes during testing, both in steady-state and transient conditions. The results of this testing campaign not only provide valuable insights into the performance of the pHB650 cryomodule but also highlight best practices and lessons learned that will inform future cryomodule testing at PIP2IT. These include adopting automated tools for data analysis, refining real-time measurement capabilities, and emphasizing detailed pre-test planning. The framework established in this campaign aims to set an improved standard for cryomodule testing and heat load reporting in future cryomodule test campaigns.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗

Fast and flexible control of beam longitudinal phase space for high-repetition-rate x-ray free-electron lasers

The wide-ranging requirements for the photon properties from multiple beamlines in superconducting based free-electron lasers (FELs) demand more challenging beam manipulation techniques. Shot-by-shot control of electron beam bunch length and peak current at high repetition rate up to megahertz is highly desired. In this paper, we present a comprehensive study of a method based on a 2-m-long normal conducting radio-frequency cavity to achieve fast and flexible control of beam compression and realize the full potential of the facility, including theoretical analysis, beam dynamics simulations, and conceptual cavity design for the Linac Coherent Light Source II and its high-energy upgrade. We illustrate the physical mechanism of the chirping cavity on the control of the final beam compression and propose methods to lower the requirements for the cavity parameters. The application of this method will allow tailored photon properties of individual beamlines to optimize their performance and drastically improve the multiplexing capabilities of a high-repetition rate FEL facility.

42 ENGINEERING↗

Heat load measurements for the PIP-II pHB650 cryomodule

Phase-3 testing of the pHB650 cryomodule at the PIP-II Injector Test Facility was conducted to evaluate the effectiveness of heat load mitigations performed after earlier phases of testing and to continue pinpointing any sources of unexpectedly high heat loads.. The programme measured HTTS, LTTS, and 2 K isothermal/non-isothermal loads under "standard", "linac", and "simulated dynamic" operating modes, recording data both inside the cryomodule and across the bayonet can circuits. Thermal-acoustic oscillations were eliminated by replacing the original G10 cooldown-valve stem with a stainless-steel stem fitted with wipers. A newly developed Python script automated acquisition of ACNET data, performed real-time heat-load calculations, and generated plots and tables that were posted to the electronic logbook within minutes, vastly reducing manual effort and accelerating feedback between SRF and cryogenics teams. Analysis showed that JT heat-exchanger effectiveness and temperature stratification in the two-phase and relief piping strongly influence the observed loads and helped isolate sources of excess heat. The campaign demonstrates that rigorous pre-test planning, real-time diagnostics, and automated reporting can improve both accuracy and efficiency, providing a template for future PIP-II cryomodule tests and for implementing targeted heat-load mitigations.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.] (ORCID:↗

Design and optimization of higher order mode couplers for the superconducting cavities of the PERLE energy recovery linac

The Powerful Energy Recovery Linac for Experiments (PERLE) is an energy recovery linac (ERL) facility based on superconducting radio-frequency (SRF) technology to be hosted at the Laboratoire de Physique des 2 Infinis Irène Joliot-Curie (IJCLab) in France. With a target beam power of 10 MW, PERLE aims to demonstrate the high-current, continuous wave, multi-pass operation to validate options for future high-energy machines, such as the 50 GeV ERL proposed for the Large Hadron electron Collider (LHeC) and the Future Circular electron-hadron Collider (FCC-eh), and host dedicated particle physics and nuclear experiments. In high-current ERLs, the regenerative Beam Breakup (BBU), emerging from the beam and cavity Higher Order Modes (HOMs) interaction, is a major concern for their stable operation. Beam-induced HOMs can increase the cavity heat load at cryogenic temperature and cause beam instabilities. HOM couplers are installed in the cavity beam pipes to absorb HOM energy and mitigate these effects. This thesis presents the design and optimization of several coaxial HOM couplers for the 5-cell 801.58 MHz elliptical Nb cavities of the 500 MeV PERLE ERL configuration. The RF transmission of the HOM couplers was optimized to enhance the damping of the most dangerous HOMs. The optimized HOM couplers were integrated into endgroups to simulate their damping performance and thermal behavior. The optimized HOM couplers were 3D-printed in epoxy and copper-coated. Low-power RF measurements were conducted on the produced HOM couplers installed in copper PERLE-type cavities to validate their damping performance and propose several endgroups for the PERLE 5-cell cavity to mitigate HOMs below the BBU instability limits.

Barbagallo, Carmelo↗

Evidence of Free-Bound Transitions in Warm Dense Matter and Their Impact on Equation-of-State Measurements

Warm dense matter (WDM) is now routinely created and probed in laboratories around the world, providing unprecedented insights into conditions achieved in stellar atmospheres, planetary interiors, and inertial confinement fusion experiments. However, the interpretation of these experiments is often filtered through models with systematic errors that are difficult to quantify. Due to the simultaneous presence of quantum degeneracy and thermal excitation, transitions in which free electrons are de-excited into thermally unoccupied bound states transferring momentum and energy to a scattered x-ray photon become viable. Here we show that such free-bound transitions are a particular feature of WDM and vanish in the limits of cold and hot temperatures. The inclusion of these transitions into the analysis of recent X-ray Thomson Scattering experiments on WDM at the National Ignition Facility and the Linac Coherent Light Source is required to obtain a physically consistent temperature from the Chihara decomposition. This interpretation is corroborated by agreement with a recently developed model-free thermometry technique and presents an important step for precisely characterizing and understanding the complex WDM state of matter.

Boehme, M [HZDR Dresden]↗

Ka-band linearizer for the Ultra-Compact X-ray free-electron laser at UCLA

There is a strong demand for accelerating structures able to achieve higher gradients and more compact dimensions for the next generation of linear accelerators for research, industrial and medical applications. Notably innovative technologies will permit compact and affordable advanced accelerators as the linear collider and X-ray free-electron lasers (XFELs) with accelerating gradients over twice the value achieved with current technologies. In particular XFELs are able to produce coherent X-ray pulses with peak brightness 10 orders of magnitude greater than preceding approaches, which has revolutionized numerous research fields through imaging of the nanoscopic world at the time and length scale of atom-based systems, that is of femtosecond and Angstrom. There is a strong interest for combining these two fields, to form a proper tool with the goal of producing a very compact XFEL in order to investigate multi-disciplinary topics in chemistry, biology, materials science, medicine and physics. In the framework of the Ultra-Compact XFEL project under study at the University of California, Los Angeles, a high gradient radio-frequency accelerating structure for the longitudinal phase-space linearization with an integrated voltage of at least 15 MV working on 6th harmonic of the main Linac frequency is required. We here present the electromagnetic design of a cryogenic normal-conducting 8 cm long Ka-band standing-wave linearizer working on π mode with a target accelerating gradient beyond 100 MV/m. The studies have been performed analytically and numerically to investigate the beam dynamics and electromagnetic issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Development of Energy-Recovery Linacs

Energy-recovery linacs (ERLs) have been emphasised by the recent (2020) update of the European Strategy for Particle Physics as one of the most promising technologies for the accelerator base of future high-energy physics. The current paper has been written as a base document to support and specify details of the recently published European roadmap for the development of energy-recovery linacs. The paper summarises the previous achievements on ERLs and the status of the field and its basic technology items. The main possible future contributions and applications of ERLs to particle and nuclear physics as well as industrial developments are presented. The paper includes a vision for the further future, beyond 2030, as well as a comparative data base for the main existing and forthcoming ERL facilities. A series of continuous innovations, such as on intense electron sources or high-quality superconducting cavity technology, will massively contribute to the development of accelerator physics at large. Industrial applications are potentially revolutionary and may carry the development of ERLs much further, establishing another shining example of the impact of particle physics on society and its technical foundation with a special view on sustaining nature.

43 PARTICLE ACCELERATORS↗

Absolute contrast estimation for soft X-ray photon fluctuation spectroscopy using a variational droplet model

Abstract X-ray photon fluctuation spectroscopy using a two-pulse mode at the Linac Coherent Light Source has great potential for the study of quantum fluctuations in materials as it allows for exploration of low-energy physics. However, the complexity of the data analysis and interpretation still prevent recovering real-time results during an experiment, and can even complicate post-analysis processes. This is particularly true for high-spatial resolution applications using CCDs with small pixels, which can decrease the photon mapping accuracy resulting from the large electron cloud generation at the detector. Droplet algorithms endeavor to restore accurate photon maps, but the results can be altered by their hyper-parameters. We present numerical modeling tools through extensive simulations that mimic previous x-ray photon fluctuation spectroscopy experiments. By modification of a fast droplet algorithm, our results demonstrate how to optimize the precise parameters that lift the intrinsic counting degeneracy impeding accuracy in extracting the speckle contrast. These results allow for an absolute determination of the summed contrast from multi-pulse x-ray speckle diffraction, the modus operandi by which the correlation time for spontaneous fluctuations can be measured.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coupled order parameters and photoinduced domain walls in the charge density wave of (TaSe 4 ) 2 I

The charge density wave in (TaSe 4 ) 2 I has drawn much attention recently as a controversial candidate for an axion insulator where the CDW breaks the chiral symmetry of the Weyl semimetal. Here we use ultrafast x-ray scattering to study the collective modes of this CDW. By measuring several diffraction peaks we find that the order parameter involves coupled optical and acoustic modes. For strong near-infrared excitation, the dynamics of the x-ray diffraction show evidence of photoinduced inversion of both components of the CDW order parameter, and associated domain walls. These results demonstrate the potential of ultrafast methods to induce topological defects through highly nonequilibrium dynamics. In (TaSe 4 ) 2 I these defects should lead to exotic electronic states due to the nontrivial topology of the band structure.

36 MATERIALS SCIENCE↗

Real‐time XFEL data analysis at SLAC and NERSC: A trial run of nascent exascale experimental data analysis

X‐ray scattering experiments using free electron lasers (XFELs) are a powerful tool to determine the molecular structure and function of unknown samples (such as COVID‐19 viral proteins). XFEL experiments are a challenge to computing in two ways: (i) due to the high cost of running XFELs, a fast turnaround time from data acquisition to data analysis is essential to make informed decisions on experimental protocols; (ii) data‐collection rates are growing exponentially, requiring new scalable algorithms. Here we report our experiences analyzing data from two experiments at the Linac Coherent Light Source (LCLS) during September 2020. Raw data were analyzed on NERSC's Cori XC40 system, using the Superfacility paradigm: our workflow automatically moves raw data between LCLS and NERSC, where it is analyzed using the software package CCTBX. We achieved real time data analysis with a turnaround time from data acquisition to full molecular reconstruction in as little as 10 min—sufficient time for the experiment's operators to make informed decisions. By hosting the data analysis on Cori, and by automating LCLS‐NERSC interoperability, we achieved a data analysis rate which matches the data acquisition rate. Completing data analysis within 10 min is a first for XFEL experiments and an important milestone if we are to keep up with data‐collection trends.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-Time XFEL Data Analysis at SLAC and NERSC: a Trial Run of Nascent Exascale Experimental Data Analysis

X-ray scattering experiments using Free Electron Lasers (XFELs) are a powerful tool to determine the molecular structure and function of unknown samples (such as COVID-19 viral proteins). XFEL experiments are a challenge to computing in two ways: i) due to the high cost of running XFELs, a fast turnaround time from data acquisition to data analysis is essential to make informed decisions on experimental protocols; ii) data collection rates are growing exponentially, requiring new scalable algorithms. Here we report our experiences analyzing data from two experiments at the Linac Coherent Light Source (LCLS) during September 2020. Raw data were analyzed on NERSC's Cori XC40 system, using the Superfacility paradigm: our workflow automatically moves raw data between LCLS and NERSC, where it is analyzed using the software package CCTBX. We achieved real time data analysis with a turnaround time from data acquisition to full molecular reconstruction in as little as 10 min -- sufficient time for the experiment's operators to make informed decisions. By hosting the data analysis on Cori, and by automating LCLS-NERSC interoperability, we achieved a data analysis rate which matches the data acquisition rate. Furthermore, completing data analysis with 10 mins is a first for XFEL experiments and an important milestone if we are to keep up with data collection trends.

Blaschke, Johannes P.↗