Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Three-dimensional self-consistent simulations of multipacting in superconducting radio frequency cavities

Superconducting radio frequency (SRF) cavities are a popular choice among researchers designing new accelerators because of the reduced power losses due to surface resistance. However, SRF cavities still have unresolved problems, including the loss of power to stray electrons. Sources of these electrons are field emission from the walls and ionization of background gas, but the predominant source is secondary emission yield (SEY) from electron impact. When the electron motion is in resonance with the cavity fields the electrons strike the cavity surface repeatedly creating a resonant build up of electrons referred to as multipacting. Cavity shaping has successfully reduced multipacting for cavities used in very high energy accelerators. However, multipacting is still a concern for the cavity power couplers, where shaping is not possible, and for cavities used to accelerate particles at moderate velocities. This Phase II project built upon existing models in the VORPAL simulation framework to allow for simulations of multipacting behavior in SRF cavities and their associated structures. The technical work involved allowed existing models of secondary electron generation to work with the complex boundary conditions needed to model the cavity structures. The types of data produced by VORPAL were also expanded to include data common used by cavity designers to evaluate cavity performance. Post-processing tools where also modified so provide information directly related to the conditions that produce multipacting. These new methods were demonstrated by running simulations of a cavity design being developed by researchers at Jefferson National Laboratory to attempt to identify the multipacting that would be an issue for the cavity design being considered. These simulations demonstrate that VORPAL now has the capabilities to assist researchers working with SRF cavities to understand and identify possible multipacting issues with their cavity designs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Three-dimensional self-consistent simulations of multipacting in superconducting radio frequency cavities

Superconducting radio frequency (SRF) cavities are a popular choice among researchers designing new accelerators because of the reduced power losses due to surface resistance. However, SRF cavities still have unresolved problems, including the loss of power to stray electrons. Sources of these electrons are field emission from the walls and ionization of background gas, but the predominant source is secondary emission yield (SEY) from electron impact. When the electron motion is in resonance with the cavity fields the electrons strike the cavity surface repeatedly creating a resonant build up of electrons referred to as multipacting. Cavity shaping has successfully reduced multipacting for cavities used in very high energy accelerators. However, multipacting is still a concern for the cavity power couplers, where shaping is not possible, and for cavities used to accelerate particles at moderate velocities. This Phase II project built upon existing models in the VORPAL simulation framework to allow for simulations of multipacting behavior in SRF cavities and their associated structures. The technical work involved allowed existing models of secondary electron generation to work with the complex boundary conditions needed to model the cavity structures. The types of data produced by VORPAL were also expanded to include data common used by cavity designers to evaluate cavity performance. Post-processing tools were also modified to provide information directly related to the conditions that produce multipacting. These new methods were demonstrated by running simulations of a cavity design being developed by researchers at Jefferson National Laboratory to attempt to identify the multipacting that would be an issue for the cavity design being considered. These simulations demonstrate that VORPAL now has the capabilities to assist researchers working with SRF cavities to understand and identify possible multipacting issues with their cavity designs.

43 PARTICLE ACCELERATORS↗

Oscillating plasma bubbles. I. Basic properties and instabilities

Plasma bubbles are created in an ambient discharge plasma. A bubble is a plasma volume of typically spherical shape, which is separated from the ambient plasma by a negatively biased grid of high transparency. Ions and electrons from the ambient plasma flow into the bubble volume. In steady state the flow of particles and currents is divergence-free, which is established by the plasma potential inside the bubble. The grid has two sheaths, one facing the ambient plasma, the other the bubble plasma. The inner sheath is observed to become unstable, causing the plasma potential in the bubble to oscillate. The instability arises from an excess of ions and a deficiency of electrons. Its frequency is in the range of the ion plasma frequency but depends on all parameters which influence the charge density in the sheath. When the grid voltage is very negative, electrons cannot enter the outer sheath, and the inner sheath becomes a virtual anode which reflects ions such that the bubble interior is empty. When an electron source is placed into the bubble it can neutralize the ions and the bubble refills. Without plasma sources or sinks the bubble plasma is extremely sensitive to perturbations by probes. Modified current-voltage characteristics of Langmuir and emissive probes are demonstrated. A sequence of papers first describes the basic steady-state properties, then the time evolution of bubbles, the effects of electron sources in bubbles, and the role of the grid and bubble geometry. The physics of plasma bubbles is important to several fields of basic plasma physics such as sheaths, sheath instabilities, diagnostic probes, electrostatic confinement, and current and space charge neutralization of beams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-current diode with ferroelectric plasma source-assisted hollow anode

The operation of a ferroelectric plasma source-assisted hollow anode (HA) electron source in a vacuum diode powered by an {approx}200 kV and {approx}400 ns pulsed generator was studied using time- and space-resolved laser induced fluorescence diagnostics. It was found that the plasma ion ''temperature'' in the vicinity of the HA output grid increases up to {approx}15 eV during the accelerating pulse, which is consistent with a model of the potential screening of the grid by the randomly moving ions [Phys. Plasmas 13, 073506 (2006)]. Also it was shown that the increase in the HA plasma potential up to several kilovolts because of the appearance of a noncompensated ion charge in the HA bulk plasma due to electrons fast extraction, leads to explosive emission centers being generated at the HA grid and to nonuniformity in the cross-sectional electron beam current density. Finally, the plasma prefilled mode of diode operation was studied using a simple one-dimensional model of the plasma erosion and the HA plasma electron heating by energetic ions was considered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bioavailability of Fe(III) in Loess Sediments: An Important Source of Electron Acceptors

A quantitative study was conducted to understand if Fe (III) in loess sediments is available for microbial respiration by using a common metal reducing bacterium, Shewanella putrefaciens, CN32. The loess samples were collected from three different sites: St. Louis (Peoria), Missouri, USA; Huanxia (HX) and Yanchang (YCH), Shanxi Province of China. Wet chemical analyses indicated that the total Fe concentration for the three samples was 1.69%, 2.76%, and 3.29%, respectively, of which 0.48%, 0.67%, and 1.27% was Fe(III). All unreduced loess sediments contained iron oxides and phyllosilicates (smectite, illite, chlorite, vermiculite), in addition to common minerals such as quartz, feldspar, plagioclase, calcite, and dolomite. Bioreduction experiments were performed at a loess concentration of 20 mg/mL using lactate as the sole electron donor, Fe(III) in loess as the sole electron acceptor in the presence and absence of anthraquinone-2, 6-disulfonate (AQDS) as an electron shuttle. Experiments were performed in non-growth (bicarbonate buffer) and growth (M1) media with a cell concentration of ~2.8 x 107 and 2.1 x 107 cells/mL, respectively. The unreduced and bioreduced solids were analyzed by X-ray diffraction (XRD), Mössbauer spectroscopy, diffuse reflection spectroscopy (DRS), and scanning electron microscopy/energy dispersive spectroscopy (SEM/EDS) methods. Despite many similarities among the three loess samples, the extent and rate of Fe (III) reduction varied significantly. For example, in presence of AQDS the extent of reduction in the non-growth experiment was 25% in HX, 34% in Peoria, and 38% in YCH. The extent of reduction in the growth experiment was 72% in HX, 94% in Peoria, and 56% in YCH. The extent of bioreduction was lower in absence of AQDS. Overall, AQDS and the M1 growth medium significantly enhanced the rate and extent of bioreduction. Fe(III) in iron oxides and Fe(III)-containing phyllosilicates was bioreduced. Biogenic illite, siderite, and vivianite formed. The results of this study suggest that Fe (III) in loess sediments represents a potentially important source of electron acceptors to support microbial activity in dry environments.

58 GEOSCIENCES↗

Combined experimental setup for spin- and angle-resolved direct and inverse photoemission

We present a combined experimental setup for spin- and angle-resolved direct and inverse photoemission in the vacuum ultraviolet energy range for measurements of the electronic structure below and above the Fermi level. Both techniques are installed in one ultrahigh-vacuum chamber and, as a consequence, allow quasisimultaneous measurements on one and the same sample preparation. The photoemission experiment consists of a gas discharge lamp and an electron energy analyzer equipped with a spin polarization detector based on spin-polarized low-energy electron diffraction. Our homemade inverse-photoemission spectrometer comprises a GaAs photocathode as spin-polarized electron source and Geiger-Mueller counters for photon detection at a fixed energy of 9.9 eV. The total energy resolution of the experiment is better than 50 meV for photoemission and better than 200 meV for inverse photoemission. The performance of our combined direct and inverse-photoemission experiment with respect to angular and energy resolutions is exemplified by the Fermi-level crossing of the Cu(111) L-gap surface state. Spin-resolved measurements of Co films on Cu(001) are used to characterize the Sherman function of the spin polarization detector as well as the spin polarization of our electron source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of ultra-low-energy electron scattering cross sections of atoms and molecules

A new experimental technique for the total cross section measurements of ultra-low energy electron collisions with atoms and molecules utilizing the synchrotron radiation is presented. The technique employs a combination of the penetrating field technique and the threshold photoionization of rare gas atoms using the synchrotron radiation as an electron source in order to produce a high resolution electron beam at very low energy. Absolute total cross sections for electron scattering from He, Ne, Ar, Kr, and Xe in the energy region from extremely low electron energy to 20 eV are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Injection System Diagnostics

The linac beam diagnostics will be provided by Research Instruments (former ACCEL) as part of the linac package: • one removable Faraday cup after electron source, • five wall current monitors (WCM) located after electron source, bunching system and accelerating sections 1, 2, and 3, • six removable YAG:Ce screens including cameras, • five sets of buttons for beam position monitoring. BNL will provide receivers for the beam position monitors (BPMs).

36 MATERIALS SCIENCE↗

First Demonstration of Electron Beam Generation and Characterization With an All Superconducting Radio-Frequency (SRF) Photoinjector

In preparation for a high brightness, high average current electron source for the energy recovery linac BERLinPro an all superconducting radio-frequency (SRF) photoinjector is now in operation at Helmholtz-Zentrum Berlin. The aim of this experiment is beam demonstration with a high brightness electron source able to generate short, few ps long pulse length electron bunches from a superconducting (SC) cathode film made of Pb coated on the backplane of a Nb SRF cavity. This paper describes the setup of the experiment, first results from beam measurements and capabilities of the source derived from beam dynamics considerations. In April 2011 the photoinjector generated and accelerated for the first time electron beam. This result marks the highlight of the project running for two years starting with project approval in May 2009.

43 PARTICLE ACCELERATORS↗

Laparoscopic tumor therapy using high energy electron irradiation

A laparoscopic tumor therapy method and an articulated electron beam transport system are provided for use with a high power, long focus electron source for tumor therapy. The high power, long focus electron source generates an e-beam. The e-beam is transported through a laparoscopic tube proximate a target tumor for electron irradiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electron-stimulated reactions in nanoscale water films adsorbed on (alpha)-Al2O3(0001)

The radiation-induced decomposition and desorption of nanoscale amorphous solid water (D2O) films adsorbed on -Al2O3(0001) surface was studied at low temperature in ultrahigh vacuum using temperature programmed desorption (TPD) and electron stimulated desorption (ESD) with a mono-energetic, low energy electron source. ESD yields of molecular products ( D2, O2 and D¬2O) and the total sputtering yield increased with increasing D2O coverage up to ~15 water monolayers (i.e. ~15 1015 cm-2) to a coverage-independent level for thicker water films. Experiments with isotopically-layered water films (D2O and H2O) demonstrated that the highest water decomposition yields occurred at the interfaces of the nanoscale water films with the alumina substrate and vacuum. However, the increased reactivity of the water/alumina interface is relatively small compared to the enhancements in the non-thermal reactions previously observed at the water/Pt(111) and water/TiO2(110) interfaces. We propose that the relatively low activity of Al2O3(0001) for the radiation-induced production of molecular hydrogen is associated with lower reactivity of this surface with hydrogen atoms, which are likely precursors for the molecular hydrogen.

Petrik, Nikolay G.↗

Influence of Carbon Sources and Electron Shuttles on Ferric Iron Reduction by Cellulomonas sp. Strain ES6

Microbially reduced iron minerals can reductively transform a variety of contaminants including heavy metals, radionuclides, chlorinated aliphatics, and nitroaromatics. A number of Cellulomonas spp. strains, including strain ES6, isolated from aquifer samples obtained at the U.S. Department of Energy's Hanford site in Washington, have been shown to be capable of reducing Cr(VI), TNT, natural organic matter, and soluble ferric iron [Fe(III)]. This research investigated the ability of Cellulomonas sp. strain ES6 to reduce solid phase and dissolved Fe(III) utilizing different carbon sources and various electron shuttling compounds. Results suggest that Fe(III) reduction by and growth of strain ES6 was dependent upon the type of electron donor, the form of iron present, and the presence of synthetic or natural organic matter, such as anthraquinone-2,6-disulfonate (AQDS) or humic substances. This research suggests that Cellulomonas sp. strain ES6 could play a significant role in metal reduction in the Hanford subsurface and that the choice of carbon source and organic matter addition can allow for independent control of growth and iron reduction activity.

54 ENVIRONMENTAL SCIENCES↗

Experimental Characterization of Photoemission from Plasmonic Nanogroove Arrays

Metal photocathodes are an important source of high-brightness electron beams, ubiquitous in the operation of both large-scale accelerators and table-top microscopes. When the surface of a metal is nanoengineered with patterns on the order of the optical wavelength, it can lead to the excitation and confinement of surface-plasmon-polariton waves that drive nonlinear photoemission. In this work, we aim to evaluate gold plasmonic nanogrooves as a concept for producing bright electron beams for accelerators via nonlinear photoemission. Here, we do this by first comparing their optical properties to numerical calculations from first principles to confirm our ability to fabricate these nanoscale structures. Their nonlinear photoemission yield is found by measuring emitted photocurrent as the intensity of their driving laser is varied. Finally, the mean transverse energy of this electron source is found using the solenoid-scan technique. Our data demonstrate the ability of these cathodes to provide a tenfold enhancement in the efficiency of photoemission over flat metals driven with a linear process. We find that these cathodes are robust and capable of reaching sustained average currents over 100 nA at optical intensities larger than 2 GW cm –2 with no degradation of performance. The emittance of the generated beam is found to be highly asymmetric, a fact we can explain with calculations involving the also asymmetric roughness of the patterned surface. These results demonstrate the use of nanoengineered surfaces as enhanced photocathodes, providing a robust air-stable source of high-average-current electron beams hopefully with great potential for industrial and scientific applications.

47 OTHER INSTRUMENTATION↗

Recent developments and operation of polarized photocathodes at Jefferson Lab

Spin-polarized electron sources are critical to a wide range of accelerator-based applications for nuclear and particle physics. At Thomas Jefferson National Accelerator Facility, they play a central role in delivering high-quality polarized beams for precision nuclear physics experiments and next-generation parity-violation measurements, where stringent control of systematic uncertainties is essential. These sources are also expected to be key components of other initiatives, including the Electron-Ion Collider and the potential future positron capabilities at Jefferson Lab. In this talk, I will present ongoing research and development efforts at Jefferson Lab focused on the design, fabrication and optimization of spin-polarized photocathodes. This includes growth using molecular beam epitaxy (MBE) or metal-organic chemical vapor deposition (MOCVD), along with detailed characterization of their performance metrics, such as quantum efficiency (QE), electron spin polarization and QE anisotropy, all of which are increasingly important metrics for polarized electron sources at Jefferson Lab and the Electron-Ion Collider. Strategies to mitigate QE anisotropy, which is critical for reducing helicity-correlated beam asymmetries in precision experiments such as MOLLER will be highlighted. Finally, I will present recent efforts aimed at improving the operational lifetime of spin-polarized photocathodes in injector environments, particularly under high-voltage conditions in DC electron guns. These developments are essential for enabling reliable, high-performance operation of polarized sources for current and future accelerator programs.

Kachwala, Alimohammed [Thomas Jefferson National A↗

Monte Carlo based beam model using a photon MLC for modulated electron radiotherapy

Purpose: Modulated electron radiotherapy (MERT) promises sparing of organs at risk for certain tumor sites. Any implementation of MERT treatment planning requires an accurate beam model. The aim of this work is the development of a beam model which reconstructs electron fields shaped using the Millennium photon multileaf collimator (MLC) (Varian Medical Systems, Inc., Palo Alto, CA) for a Varian linear accelerator (linac). Methods: This beam model is divided into an analytical part (two photon and two electron sources) and a Monte Carlo (MC) transport through the MLC. For dose calculation purposes the beam model has been coupled with a macro MC dose calculation algorithm. The commissioning process requires a set of measurements and precalculated MC input. The beam model has been commissioned at a source to surface distance of 70 cm for a Clinac 23EX (Varian Medical Systems, Inc., Palo Alto, CA) and a TrueBeam linac (Varian Medical Systems, Inc., Palo Alto, CA). For validation purposes, measured and calculated depth dose curves and dose profiles are compared for four different MLC shaped electron fields and all available energies. Furthermore, a measured two-dimensional dose distribution for patched segments consisting of three 18 MeV segments, three 12 MeV segments, and a 9 MeV segment is compared with corresponding dose calculations. Finally, measured and calculated two-dimensional dose distributions are compared for a circular segment encompassed with a C-shaped segment. Results: For 15 × 34, 5 × 5, and 2 × 2 cm{sup 2} fields differences between water phantom measurements and calculations using the beam model coupled with the macro MC dose calculation algorithm are generally within 2% of the maximal dose value or 2 mm distance to agreement (DTA) for all electron beam energies. For a more complex MLC pattern, differences between measurements and calculations are generally within 3% of the maximal dose value or 3 mm DTA for all electron beam energies. For the two-dimensional dose comparisons, the differences between calculations and measurements are generally within 2% of the maximal dose value or 2 mm DTA. Conclusions : The results of the dose comparisons suggest that the developed beam model is suitable to accurately reconstruct photon MLC shaped electron beams for a Clinac 23EX and a TrueBeam linac. Hence, in future work the beam model will be utilized to investigate the possibilities of MERT using the photon MLC to shape electron beams.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Production and ion-ion cooling of highly charged ions in electron string ion source

The scheme of an internal injection of Au atoms into the working space of the ''Krion-2'' electron string ion source (ESIS) was applied and tested. In this scheme Au atoms are evaporated from the thin tungsten wire surface in vicinity of the source electron string. Ion beams with charge states up to Au{sup 51+} were produced. Ion-ion cooling with use of C and O coolant ions was studied. It allowed increasing of the Au{sup 51+} ion yield by a factor of 2. Ions of Kr up to charge state 28+ were also produced in the source. Electron strings were first formed with injection electron energy up to 6 keV. Methods to increase the ESIS ion output are discussed.

43 PARTICLE ACCELERATORS↗

Results of the SLAC LCLS Gun High-Power RF Tests

The beam quality and operational requirements for the Linac Coherent Light Source (LCLS) currently being constructed at SLAC are exceptional, requiring the design of a new RF photocathode gun for the electron source. Based on operational experience at SLAC's GTF and SDL and ATF at BNL as well as other laboratories, the 1.6cell s-band (2856MHz) gun was chosen to be the best electron source for the LCLS, however a significant redesign was necessary to achieve the challenging parameters. Detailed 3-D analysis and design was used to produce near-perfect rotationally symmetric rf fields to achieve the emittance requirement. In addition, the thermo-mechanical design allows the gun to operate at 120Hz and a 140MV/m cathode field, or to an average power dissipation of 4kW. Both average and pulsed heating issues are addressed in the LCLS gun design. The first LCLS gun is now fabricated and has been operated with high-power RF. The results of these high-power tests are presented and discussed.

43 PARTICLE ACCELERATORS↗

Multi-alkalai photocathodes production for LEReC DC gun

Low Energy RHIC electron Cooling (LEReC) is a bunched electron cooler at RHIC. The LEReC’s electron source needs provide up to 85 mA average current electron beam. The Bi-alkali photocathodes are chosen as electron source due to its long lifetime and high QE at the visible wavelength. Because the DC gun needs to produce 24/7 beams over several months, two cathode production systems and three transfer systems carrying multiple cathodes are designed and one set commissioned. In this report, we will describe our photocathode production and transfer systems and discuss the cathode's performance from cathode growth system to the DC gun.

43 PARTICLE ACCELERATORS↗