Search NASA⌕ Search

SEARCH · Search NASA

Results for “error field”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Comparing field data using Alpert multi-wavelets

In this paper we introduce a method to compare sets of full-field data using Alpert tree-wavelet transforms. The Alpert tree-wavelet methods transform the data into a spectral space allowing the comparison of all points in the fields by comparing spectral amplitudes. The methods are insensitive to translation, scale and discretization and can be applied to arbitrary geometries. This makes them especially well suited for comparison of field data sets coming from two different sources such as when comparing simulation field data to experimental field data. We have developed both global and local error metrics to quantify the error between two fields. Additionally, we verify the methods on two-dimensional and three-dimensional discretizations of analytical functions. Furthermore, we then deploy the methods to compare full-field strain data from a simulation of elastomeric syntactic foam.

42 ENGINEERING↗

A parametric study of aliasing error for a narrow field of view scanning radiometer

Starting from the general measurement equation, it is shown that a NFOV scanner can be approximated by a spatially invariant system whose point spread function depends on the detector shape and angular characteristics and electrical filter transfer function for given patches at the top of the atmosphere. The radiometer is modeled by a detector, electrical filter, analog to digital converter followed by a reconstruction filter. The errors introduced by aliasing and blurring into a reconstruction of the input radiant exitance are modeled and analyzed for various detector shapes, sampling intervals, electrical filters and scan types. Quantitative results on the errors introduced are presented showing the various tradeoffs between design parameters. The results indicate that proper selection of detector shape coupled with electrical filter can reduce aliasing errors significantly.

Halyo, N.↗

SU-F-T-299: An Experimental 2D Computed Radiography (CR) Dosimeter for IMRT. Are In-Field Measurements Affected by the Low Energy Photon Overresponse?

Purpose: Computed Radiography (CR) dosimetry could offer film dosimetry resolution and flexibility but with reusability and instantaneous processing. For an experimental CR-plate, designed for radiotherapy (Zeff=18), CR’s typical out-of-field over-response to low energy photons was previously reduced to 8%. The present work assesses the impact of the residual over-response when open-fields are combined or when intensity modulated fields are used. Methods: Agfa Healthcare’s experimental CRplate was scanned and erased 4min after each irradiation using a flying-spot CR-15-X-engine based reader, which was adapted for radiotherapy dosimetry. A CR-plate specific calibration and uniformity correction was used.For open-fields two abutting half beams (5×10cm{sup 2}) captured out-offield and in-field doses in a single image. Additionally, both half beams were measured individually as well as a 3×18Gy open-field SBRT-lung treatment. For intensity modulated fields standard test patterns (Chair and Pyramid) and a clinical 5×5Gy rectal VMAT plan were captured. All measurements were compared to the corresponding dose calculations. Results: For open-fields the out-of-field overdose was clearly larger than the in-field overdose (10% vs. 4%). The sum of the individual measurements corresponded well with the combined measurement (dose difference, ΔD<−2.2%). The SBRT case had no overdose in the high dose region; ΔD=−5.6%±3.3%, the deviation was attributed to CR-fading effects (−0.3%/min) which were not corrected for.Compared to open-fields, intensity modulated deliveries had a further increased over-response out-offield (ΔD=+58% to +125% [Chair] +43% [Pyramid]), due to the increased amount of low energy photons for IMRT. However, this effect was not measured in-field where even decreased dose signals were observed (ΔD=−0.3% to +2.25% [Chair], −4.5% to −0.1% [Pyramid]). The rectal VMAT treatment had a dose difference +2.4%±6.0%. The in-field deviations were attributed to a residual non-uniformity. Conclusion: The experimental CRplate’s out-of-field over-response does not propagate in in-field overresponse errors when static or dynamic (IMRT/VMAT) abutting fields are used.

60 APPLIED LIFE SCIENCES↗

Overview of SIM external calibration

Like all astrometric instruments, the Space Interferometry Mission (SIM) suffers from field-dependent errors requiring calibration. Diffraction effects in the delay line, polarization rotations on comer cubes, and beam walk across imperfect optics, all contribute to field-distortion that is significantly larger than is acceptable. The bulk of the systematic error is linear across the field - that is, it results in a magnification error. We show that the linear terms are inconsequential to the performance of SIM because they are inseparable from baseline length and orientation errors. One approach to calibrating the higher-order terms is to perform external' calibration; that is, SIM periodically makes differential measurements of a field of bright stars whose positions are not precisely known. We describe the requirements and constraints on the external calibration process and lay the groundwork for a specific procedure detailed in accompanying papers.

Space↗

SU-E-J-235: Varian Portal Dosimetry Accuracy at Detecting Simulated Delivery Errors

Purpose: To use receiver operating characteristic (ROC) analysis to quantify the Varian Portal Dosimetry (VPD) application's ability to detect delivery errors in IMRT fields. Methods: EPID and VPD were calibrated/commissioned using vendor-recommended procedures. Five clinical plans comprising 56 modulated fields were analyzed using VPD. Treatment sites were: pelvis, prostate, brain, orbit, and base of tongue. Delivery was on a Varian Trilogy linear accelerator at 6MV using a Millenium120 multi-leaf collimator. Image pairs (VPD-predicted and measured) were exported in dicom format. Each detection test imported an image pair into Matlab, optionally inserted a simulated error (rectangular region with intensity raised or lowered) into the measured image, performed 3%/3mm gamma analysis, and saved the gamma distribution. For a given error, 56 negative tests (without error) were performed, one per 56 image pairs. Also, 560 positive tests (with error) with randomly selected image pairs and randomly selected in-field error location. Images were classified as errored (or error-free) if percent pixels with γ<κ was < (or ≥) τ. (Conventionally, κ=1 and τ=90%.) A ROC curve was generated from the 616 tests by varying τ. For a range of κ and τ, true/false positive/negative rates were calculated. This procedure was repeated for inserted errors of different sizes. VPD was considered to reliably detect an error if images were correctly classified as errored or error-free at least 95% of the time, for some κ+τ combination. Results: 20mm{sup 2} errors with intensity altered by ≥20% could be reliably detected, as could 10mm{sup 2} errors with intensity was altered by ≥50%. Errors with smaller size or intensity change could not be reliably detected. Conclusion: Varian Portal Dosimetry using 3%/3mm gamma analysis is capable of reliably detecting only those fluence errors that exceed the stated sizes. Images containing smaller errors can pass mathematical analysis, though may be detected by visual inspection. This work was not funded by Varian Oncology Systems. Some authors have other work partly funded by Varian Oncology Systems.

60 APPLIED LIFE SCIENCES↗

Stiffness-matrix condition number and shape sensitivity errors

This paper derives an error magnification index for assessing the sensitivity of the displacement field to errors in the load vector. It is shown that the error magnification index is less conservative than the stiffness-matrix condition number and that, for some cases, no error magnification occurs even when the condition number is very high. The proposed index was used to calculate the derivatives of beam response to changes in the beam structural parameters, using a semianalytical method. It is shown that the proposed index discriminates well between the calculation of the derivative with respect to length, which is very sensitive to errors, and the calculation of the derivative with respect to cross-sectional height, which is not sensitive.

Haftka, Raphael T.↗

On error sources during airborne measurements of the ambient electric field

The principal sources of errors during airborne measurements of the ambient electric field and charge are addressed. Results of their analysis are presented for critical survey. It is demonstrated that the volume electric charge has to be accounted for during such measurements, that charge being generated at the airframe and wing surface by droplets of clouds and precipitation colliding with the aircraft. The local effect of that space charge depends on the flight regime (air speed, altitude, particle size, and cloud elevation). Such a dependence is displayed in the relation between the collector conductivity of the aircraft discharging circuit - on one hand, and the sum of all the residual conductivities contributing to aircraft discharge - on the other. Arguments are given in favor of variability in the aircraft electric capacitance. Techniques are suggested for measuring from factors to describe the aircraft charge.

Evteev, B. F.↗

Interpolation Errors in Spectrum Analyzers

To obtain the proper measurement amplitude with a spectrum analyzer, the correct frequency-dependent transducer factor must be added to the voltage measured by the transducer. This report examines how entering transducer factors into a spectrum analyzer can cause significant errors in field amplitude due to the misunderstanding of the analyzer's interpolation methods. It also discusses how to reduce these errors to obtain a more accurate field amplitude reading.

Martin, J. L.↗

The error associated with use of various forms of the divergence equation to diagnose geopotential and temperature

This study utilizes a model-generated data set to evaluate the errors associated with the diagnosis of geopotential height using three approximate forms of the divergence equation (DE). The DE was solved on the original sigma-coordinate surfaces of the model to exclude any error produced in the process of interpolating the data from observation points to the coordinate surface of the DE. An inviscid, nonlinear, divergent DE produced rms geopotential height errors as large as 3 m and rms temperature errors of over 26 C in the lower planetary boundary layer (PBL), with minimal errors above 800 mb. Elimination of the isobaric divergence in the velocity field caused additional height errors of 5-6 m and temperature errors of 0.4-1.2 C in the free troposphere. Use of a further-degraded DE without nonlinear terms caused height errors of 10-15 m in the upper troposphere with modestly increased temperature errors. Error fields at all levels had synoptic-scale features, with some mesoalpha structure. No spatial noise was apparent. Use of a temporal spectral filter to eliminate high-frequency modes from the model-generated data did not significantly influence the error associated with use of various forms of the DE.

Modica, George M.↗

Flight research program. VI.

Correlation between heart rate, landing error and field of view for binocular and monocular sphere of vision of jet pilots

VISUAL FIELD↗

Optimization of multimagnetometer systems on a spacecraft

Magnetometers on a radial boom may be employed to determine the first N-1 multipole contributions to the spacecraft field and improve the total accuracy of a magnetic field experiment. The total error for systems of one to four magnetometers is investigated. The optimal magnetometer locations, for which the total error is a minimum, are found for given boom-length, instrument errors and magnetic field models characteristic for spacecraft with only a restricted or ineffective magnetic cleanliness program.

Neubauer, F. M.↗

Simplification of the Kalman filter for meteorological data assimilation

The paper proposes a new statistical method of data assimilation that is based on a simplification of the Kalman filter equations. The forecast error covariance evolution is approximated simply by advecting the mass-error covariance field, deriving the remaining covariances geostrophically, and accounting for external model-error forcing only at the end of each forecast cycle. This greatly reduces the cost of computation of the forecast error covariance. In simulations with a linear, one-dimensional shallow-water model and data generated artificially, the performance of the simplified filter is compared with that of the Kalman filter and the optimal interpolation (OI) method. The simplified filter produces analyses that are nearly optimal, and represents a significant improvement over OI.

Dee, Dick P.↗