At least 307 records · Page 17

Pulse shape measurements for neutron/gamma discrimination using the TOFPET2 ASIC

Many highly pixelated organic scintillator detection systems would benefit from independent readout of each scintillator pixel. Recent advances in Silicon Photomultiplier (SiPM) technology makes this goal feasible, however the data acquisition from potentially hundreds or thousands of channels requires a low-cost and compact solution. For pixelated neutron detection with organic scintillators, the capability to distinguish between neutron and gamma interactions using Pulse Shape Discrimination (PSD) is required along with pulse charge and time of arrival. The TOFPET2 ASIC from PETsys Electronics is a 64-channel readout chip providing pulse time and charge integration measurements from SiPMs, and is specifically designed for time-of-flight positron-emission tomography. Using an 8 × 8 array of 6 mm × 6 mm J-series SiPMs from SensL/OnSemi (ArrayJ-60035-64P-PCB), we have studied the energy and PSD performance of the TOFPET2 ASIC using a 4 × 4 array of 6 mm × 6 mm × 30 mm trans -Stilbene crystals from Inrad Optics and a custom SiPM routing board from PETsys Electronics. In conclusion, using a time-over-threshold method, we measure a maximum PSD figure-of-merit of approximately 1.2 at 478 keV (the Compton edge of 662 keV) for a J-series SiPM operating at an over-voltage of 3V.

47 OTHER INSTRUMENTATION↗

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION↗

A new hybrid gadolinium nanoparticles-loaded polymeric material for neutron detection in rare event searches

Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surrounding the active target volume. In the context of the development of DarkSide-20k detector at INFN Gran Sasso National Laboratory (LNGS), several R&D projects were conceived and developed for the creation of a new hybrid material rich in both hydrogen and gadolinium nuclei to be employed as an essential element of the neutron detector. Thanks to its very high cross-section for neutron capture, gadolinium is one of the most widely used elements in neutron detectors, while the hydrogen-rich material is instrumental in efficiently moderating the neutrons. In this paper results from one of the R&Ds are presented. In this effort the new hybrid material was obtained as a poly(methyl methacrylate) (PMMA) matrix, loaded with gadolinium oxide in the form of nanoparticles. We describe its realization, including all phases of design, purification, construction, characterization, and determination of mechanical properties of the new material.

Dark Matter detectors (WIMPs, axions, etc.)↗

High-resolution 3D-printed plastic scintillators with tertiary dye

Additive manufacturing offers efficient production of plastic scintillators with nontrivial geometries using vat polymerization, allowing fabrication of geometries which would be difficult or even impossible to produce using conventional subtractive manufacturing. This work presents a novel photocurable scintillator formula that includes coumarin 450 as a tertiary dye to enable high-resolution 3D printing via the manipulation of the 405 nm cure light. Bulk photocured and 3D printed (with and without tertiary dye) samples were compared through observational assessment and spectral response. All samples showed pulse shape discrimination between neutron and gamma events. Inclusion of the tertiary dye has minimal impact on emission spectrum and light output, but significant impact on print resolution as shown by comparison of printed high-complexity geometries and feature resolution test objects. With the use of a cure-limiting dye, unsupported features — such as freestanding pillars — were resolvable down to 0.7 mm. Even finer resolution at or below 0.1 mm was achieved in fully supported, integrated structures printed with off-the-shelf 405 nm desktop 3D printer. Scintillators demonstrated a light output up to 50% of EJ-200 with a PSD figure of merit up to 1.35 at 0.9–1.1 MeVee.

36 MATERIALS SCIENCE↗

STEM Ptychographic Holography of Electric and Magnetic Potentials

The development of fast an efficient direct electron imaging detectors have enabled the advancement of phase-imaging techniques in STEM such as iterative ptychography. As beneficial as these techniques are to imaging phase objects, the information recorded in the raw data is due to phase gradients across the probe, so it can be challenging to reconstruct slowly varying phase at lower spatial frequencies such as those induced by electric or magnetic potentials within the specimen. STEM holography [1,2] is an interferometric 4D-STEM technique where electrons in the beam are coherently divided into a superposition of two or more spatially separated probes which are then scanned over the specimen. For example, in a two-beam superposition, the two probes form overlapping bright field discs at the detector which then interfere (left of Fig. 1). Furthermore, if one probe passes through vacuum while the other transmits through the specimen, the resulting relative phase shift can be measured by recording shifts in the interference pattern. STEM holography is thus directly sensitive to the phase of the probe relative to the reference beam, and this phase can be measured regardless of the convergence angle of the probe, unlike single beam ptychography.

Biological Sciences↗

3 He +𝛼 resonances in 7 Be

Resonances in 7 Be which decay into the 3 He+α exit channel have been measured with improved precision using preexisting data sets. The energy and width of the J π =7/2 - state have been extracted from an invariant-mass study of projectile-breakup products originating from interactions of an E/A=10.7-MeV 10 C beam on Be and C targets. The excitation energy of this state (from the pole of the S-matrix) is determined to be E*=4.545(6)~MeV, a factor of 8 improvement in precision as compared to the ENSDF value. This improvement is enabled by fine tuning the detector calibrations using calibration resonances in 6 Li, 7 Li, 6 Be, 9 B, and 12 C whose decay energies are known to high precision. The J π =7/2- resonance in 7 Be can now itself be used as a calibration resonance in invariant-mass experiments. This utility is particularly helpful for 3 He energy calibrations of CsI(Tl) detectors which are often used in detector arrays employed for measurements with fast beams. This utility is demonstrated with a data set associated with E/A=70 MeV 7 Be beams which are inelastically excited to the 7/2 - and 5/2 - 1 resonances. Again using the pole of the S-matrix as the definition of the resonance parameters, the fitted excitation energy of the 5/2 - 1 resonance is 6.376(17) MeV, approximately 300 keV lower than the ENSDF value. Finally, its width of 565(4) keV is roughly half of the ENSDF value.

energy levels↗

Randomized Algorithms for Scientific Computing (RASC)

Randomized algorithms have propelled advances in artificial intelligence (AI) and represent a foundational research area in advancing AI for Science. Future advancements in DOE Office of Science priority areas such as climate science, astrophysics, fusion, advanced materials, combustion, and quantum computing all require randomized algorithms for surmounting challenges of complexity, robustness, and scalability. Advances in data collection and numerical simulation have changed the dynamics of scientific research and motivate the need for randomized algorithms. For instance, advances in imaging technologies such as X-ray ptychography, electron microscopy, electron energy loss spectroscopy, or adaptive optics lattice light-sheet microscopy collect hyperspectral imaging and scattering data in terabytes, at breakneck speed enabled by state-of-the-art detectors. The data collection is exceptionally fast compared with its analysis. Likewise, advances in high-performance architectures have made exascale computing a reality and changed the economies of scientific computing in the process. Floating-point operations that create data are essentially free in comparison with data movement. Thus far, most approaches have focused on creating faster hardware. Ironically, this faster hardware has exacerbated the problem by making data still easier to create. Under such an onslaught, scientists often resort to heuristic deterministic sampling schemes (e.g., low-precision arithmetic, sampling every nth element) and sacrifice potentially valuable accuracy. Dramatically better results can be achieved via randomized algorithms, reducing the data size as much as or more than naive deterministic subsampling can achieve, while retaining the high accuracy of computing on the full data set. By randomized algorithms we mean those algorithms that employ some form of randomness in internal algorithmic decisions to accelerate time to solution, increase scalability, or improve reliability. Examples include matrix sketching for solving large-scale least-squares problems (see Figure 1) and stochastic gradient descent for training machine learning models. We are not recommending heuristic methods but rather randomized algorithms that have certificates of correctness and probabilistic guarantees of optimality and near-optimality. Such approaches can be useful beyond acceleration, for example, in understanding how to avoid measure zero worst-case scenarios that plague methods such as QR matrix factorization.

97 MATHEMATICS AND COMPUTING↗

Graphical User Interface for a Biasing Board for the PSEC6

The PSEC6 is an application-specific integrated circuit (ASIC) designed for a readout system for a large area picosecond photodetector (LAPPD). The PSEC6 is currently in fabrication and pending testing. The testing system for the PSEC5, the previous iteration of the ASIC, required expensive and non-portable equipment, because the ASIC needs twelve adjustable reference voltages. The new testing system consists of an low-cost, open-source, cross-platform graphical user interface (GUI), a digital system, and a biasing board. The digital system is the interface between the GUI and biasing board, and can be implemented on a microcontroller or field-programmable gate array (FPGA). The biasing board contains twelve digital-to-analog converters (DACs) that are configurable via the GUI, which gives users the ability to write voltage values to all or specific DACs. The GUI was developed in C on Linux using the widget library GTK4 and cross-compiled for Windows compatibility. I2C and SPI protocols were implemented on an Adafruit Feather ESP32-S3 microcontroller to write commands to the DACs and PSEC6. A hardware implementation of the I2C protocol is in development on an FPGA. Since LAPPDs will be used by the Accelerator Neutrino Neutron Interaction Experiment (ANNIE) at Fermilab, the PSEC6 testing system in this internship project can potentially benefit future neutrino research. The project is relevant to the Department of Energy’s microelectronics mission, because the PSEC6 is an ASIC that will handle fast time signals arriving from the detector for readout. It also provided experience with building a cross-platform user interface, practicing digital design and implementation in hardware description language (HDL), and using simulations to inform new design iterations.

Guerrero, Sasha Camila [North Central Coll.]↗

Correlation of irradiation data using activation fluences and irradiation temperature.

Nil-ductility transition temperature data for A302-B ferritic steel were analyzed by using multiple regression. Four independent variables were used - i.e., specimen temperature during irradiation, and time-integrated specific activations (activation fluences) of fast-, intermediate-, and thermal-neutron detectors. The results of these analyses were predictive equations having the increase in transition temperature as the dependent variable. For a reference point, a similar analysis was also performed using the flux integral above 1 MeV and the irradiation temperature as independent variables. Also, the effect of excluding irradiation temperature from these analyses was studied. The results of the analyses showed that excellent correlation was achieved by using activation fluences and irradiation temperature as the independent variables. Irradiation temperature was found to account for from 29 to 46% of the data variability depending on the model used.

Lynch, J. H.↗

Design, fabrication, assembly and delivery of a laboratory prototype of a residual gas analyzer

The design, development, and testing of a wide mass range residual gas analyzer which will be one component of an integrated real time contamination monitor system are described. The instrument has been developed and tested to the laboratory prototype phase, demonstrating the performance that can be expected from a flight instrument of similar design. The instrument's analyzer is of the quadrupole type and a cold cathode ion source is employed as the ionizer. The associated electronics supply all necessary operating and mass sweep voltages for the ionizer, analyzer and electron multiplier ion detector. The instrument features a very fast linear electrometer with automatic range changing. The full mass range of 2 to 300 amu is automatically and repetitively scanned every sixty seconds and suitable telemetry outputs are provided for intensity and mass identification as well as a digital identification of the electrometer range.

Kreisman, W. S.↗

Cryogenic liquid-level detector

Detector is designed for quick assembly, fast response, and good performance under vibratory stress. Its basic parallel-plate open configuration can be adapted to any length and allows its calibration scale factor to be predicted accurately. When compared with discrete level sensors, continuous reading sensor was found to be superior if there is sloshing, boiling, or other disturbance.

Hamlet, J.↗

Transient response of Ge:Be and Ge:Zn FIR photoconductors under low background photon flux conditions

An experimental study of the transient behavior of Ge:Be and Ge:Zn photoconductors to changes in photon flux rates has been performed under the low background flux conditions (10 to the 8th photon/s) typical of astronomy and astrophysics applications. A characteristic transient behavior with time constants ranging from 0.1 to greater than 5 s has been observed in both materials when the shallow levels are very closely compensated. The detector response consists of both a fast and a slow component. The amplitude of the slow component can be up to 10 times greater than the initial fast component. It has been established that this phenomenon cannot be explained by current models of carrier sweep-out or dielectric relaxation. The transient behavior has been characterized as a function of temperature, electric field, photoconductive gain and material parameters.

Haegel, N. M.↗

Emittance Measurements at the Langley Chemical Physics Laboratory

Total hemispherical emittance measurements are made routinely for materials which may be heated by electrical resistance methods over the temperature range of 600 degrees to 2,000 F by using a black-body reference method. This employs a conical black body and a thermopile detector with a calcium fluoride lens. Emittance is obtained by measuring the radiant flux from the specimen strip and comparing it with the flux from an equal area of the black-body cone at the same temperature. The temperature measurements are made by use of thermocouples. It is planned to extend the temperature range of this type of measurement to temperatures above 2,000 F. Another technique has been investigated for measuring emittance of materials not amenable to electrical heating or thermocouple attachment. This method uses a black-body-cavity furnace similar to that used in reference 5 to measure emittance of transparent materials such as glass. The method employs a heated black-body cavity in which the semicircular specimen is allowed to come to the equilibrium temperature of the cavity and then is rotated in front of a water-cooled viewing port where a sensitive thermistor detector alternately views the specimen surface and the black-body cavity. The ratio of the two readings gives the specimen emittance directly, for the temperature of the black body. The detector output is recorded on a fast Brown self-balancing potentiometer. The furnace is provided with a water-cooled blackened shutter which may be inserted behind the specimen to eliminate any transmitted black-body radiation if the specimen is transparent. This apparatus is capable of measuring total normal emittance over the temperature range of 1,000 degrees to 2,000 F. Preliminary data for boron nitride specimens of two thicknesses are shown where total normal emittance is plotted against temperature for two experimental conditions: (1) black-body radiation incident on the back of the specimen and (2) no black-body radiation incident on the back of the specimen (that is, with a watercooled shutter behind the specimen). The data appear to indicate a slight transparency for the thin specimen and emittances of from 0.7 to 0.8 over the temperature range.

Lewis, B. W.↗

Absolute Distance Measurement with the MSTAR Sensor

The MSTAR sensor (Modulation Sideband Technology for Absolute Ranging) is a new system for measuring absolute distance, capable of resolving the integer cycle ambiguity of standard interferometers, and making it possible to measure distance with sub-nanometer accuracy. The sensor uses a single laser in conjunction with fast phase modulators and low frequency detectors. We describe the design of the system - the principle of operation, the metrology source, beamlaunching optics, and signal processing - and show results for target distances up to 1 meter. We then demonstrate how the system can be scaled to kilometer-scale distances.

modulation sideband technology for absolute rangin↗

Microstructural and Micro-Chemical Evolutions in the Irradiated UCO Fuel Kernels of AGR-1 and AGR-2 TRISO Fuel Particles

AGR-1 and AGR-2 TRISO fuel particles were fabricated with slightly different fuel kernel chemical compositions, modified fabrication processes, different fuel kernel diameters, and changed 235U enrichments. To correlate those differences with the fuel kernel responses to neutron irradiations in terms of irradiated fuel microstructure, fission products chemical and physical states, and fission gas bubble evolutions, extensive microstructural and analytical characterizations were conducted. The studies used a state of art transmission electron microscopy (TEM) equipped with Energy-dispersive X-ray spectroscopy (EDS) of four silicon solid-state detectors which have super sensitivity and fast speed. The TEM specimens were prepared from selected AGR-1 and AGR-2 irradiated fuel kernels exposed to safety testing after irradiation. The particles were chosen to represent a representative irradiation conditions with a fuel burnup within the range from 10.8 to 18.6% FIMA, and the time-average volume-average temperatures vary from 1070 to 1287°C. The 235U enrichment was 19.74 wt.% for the AGR1 fuel kernels and 14.03 wt.% for the AGR-2 fuel kernels. The TEM results show that there were significant microstructural reconstructions in the irradiated fuel kernels for both the AGR-1 and AGR-2 fuels. There are four major phases including fuel matrix of UO2 and UC, U2RuC2, and UMoC2 in the irradiated AGR2 fuel kernel. Zr and Nb form solid solution in the UC phase. UMoC2 phase often shows a detectable concentration of Tc. Pd was found to mainly locate in the buffer layer or to be associated with fission gas bubble within the UMoC2 phase. The EDS maps qualitatively show that the rare-earth fission products (Nb, et al.) preferentially reside in the UO2 phase. In contrast, in the irradiated AGR1 fuel kernel, no U2RuC2 or UMoC2 precipitates were positively identified. Instead, there is a high number of rod-shape precipitates enriched with Ru, Tc, Rh, and Pd observed in the fuel kernel center and edge zone. The difference of microstructural and micro-chemical evolutions in irradiated fuel kernels between the AGR-1 and AGR-2 TRISO fuel particle may result from a combined factor of irradiation temperature, fuel geometry and chemical composition. However, the irradiation temperature probably play a more deterministic role. Limited electron energy loss spectroscopy (EELS) characterizations on the AGR2 fuel kernel show that there is nearly no carbon in the UO2 phase while a small fraction of oxygen was detected in the UC/UMoC2 phase.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Graphical User Interface for a Biasing Board for the PSEC6

The PSEC6 is an application-specific integrated circuit (ASIC) designed for a readout system for a large area picosecond photodetector (LAPPD). The PSEC6 is currently in fabrication and pending testing. The testing system for the PSEC5, the previous iteration of the ASIC, required expensive and non-portable equipment, because the ASIC needs twelve adjustable reference voltages. The new testing system consists of an low-cost, open-source, cross-platform graphical user interface (GUI), a digital system, and a biasing board. The digital system is the interface between the GUI and biasing board, and can be implemented on a microcontroller or field-programmable gate array (FPGA). The biasing board contains twelve digital-to-analog converters (DACs) that are configurable via the GUI, which gives users the ability to write voltage values to all or specific DACs. The GUI was developed in C on Linux using the widget library GTK4 and cross-compiled for Windows compatibility. I2C and SPI protocols were implemented on an Adafruit Feather ESP32-S3 microcontroller to write commands to the DACs and PSEC6. A hardware implementation of the I2C protocol is in development on an FPGA. Since LAPPDs will be used by the Accelerator Neutrino Neutron Interaction Experiment (ANNIE) at Fermilab, the PSEC6 testing system in this internship project can potentially benefit future neutrino research. The project is relevant to the Department of Energy’s microelectronics mission, because the PSEC6 is an ASIC that will handle fast time signals arriving from the detector for readout. It also provided experience with building a cross-platform user interface, practicing digital design and implementation in hardware description language (HDL), and using simulations to inform new design iterations.

Guerrero, Sasha Camila [North Central Coll.]↗

Characterization of a Small-Scale Prototype Detector With Wide Dynamic Range for Time-Resolved High-Energy X-Ray Applications

We present characterization measurements of a fast-framing, wide-dynamic-range x-ray area detector intended for high-energy applications (≥20 keV photons). The MM-PAD-2.1 combines an integrating pixel front-end with a charge-removal mechanism to extend the maximum measurable signal to > 107 20-keV ph/pixel/frame. The charge-removal mechanism is dead-time-less (i.e., incoming signal continues to be integrated by the front-end while charge removal is taking place) up to an incoming photon rate of > 109 20-keV ph/pix/s. A 16×16 pixel prototype was fabricated and characterized using both laboratory and synchrotron x-ray sources, allowing for measurements from single-photon to high-flux conditions. High-flux measurements show linear performance up to ~1010 ph/s in a spot spanning approximately 2×1.5 pixels (FWHM). The onset of temporary radiation damage in the detector was observed during these measurements, manifesting as failure of the digital readout from the detector. These effects were seen to reverse after annealing at 30° C for several hours.

47 OTHER INSTRUMENTATION↗

Comparison of Feschenko BSM and Fast Faraday Cup with Low Energy Ion Beams

A comparison between Fast Faraday Cup and Feschenko longitudinal bunch shape detectors was recently performed at HELIAC Advanced Demonstrator beamline at GSI. Feschenko bunch shape monitor (BSM) uses the time to space conversion by means of secondary electrons emitted from a wire correlated to a rf deflector, while the fast Faraday cup (FFC) measures the deposited charge in a cup geometry matched to 50 Ohm. The FFC design aims to minimize the bunch shape dilution due to field polarization and secondary electrons produced on irradiation. An He¹⁺ with 100 µA average current and 1.4 MeV/u kinetic energy is utilized for this comparison. A buncher upstream of the detectors was operated to focus the beam longitudinally. The results are discussed in this contribution.