Reliability analysis applied to structural tests

The application of reliability theory to predict, from structural fatigue test data, the risk of failure of a structure under service conditions because its load-carrying capability is progressively reduced by the extension of a fatigue crack, is considered. The procedure is applicable to both safe-life and fail-safe structures and, for a prescribed safety level, it will enable an inspection procedure to be planned or, if inspection is not feasible, it will evaluate the life to replacement. The theory has been further developed to cope with the case of structures with initial cracks, such as can occur in modern high-strength materials which are susceptible to the formation of small flaws during the production process. The method has been applied to a structure of high-strength steel and the results are compared with those obtained by the current life estimation procedures. This has shown that the conventional methods can be unconservative in certain cases, depending on the characteristics of the structure and the design operating conditions. The suitability of the probabilistic approach to the interpretation of the results from full-scale fatigue testing of aircraft structures is discussed and the assumptions involved are examined.

Diamond, P.↗

The Philosophy which underlies the structural tests of a supersonic transport aircraft with particular attention to the thermal cycle

The information presented is based on data obtained from the Concorde. Much of this data also applies to other supersonic transport aircraft. The design and development of the Concorde is a joint effort of the British and French, and the structural test program is shared, as are all the other activities. Vast numbers of small specimens have been tested to determine the behavior of the materials used in the aircraft. Major components of the aircraft structure, totalling almost a complete aircraft, have been made and are being tested to help the constructors in each country in the design and development of the structure. Tests on two complete airframes will give information for the certification of the aircraft. A static test was conducted in France and a fatigue test in the United Kingdom. Fail-safe tests are being made to demonstrate the crack-propagation characteristics of the structure and its residual strength. Aspects of the structural test program are described in some detail, dealing particularly with the problems associated with the thermal cycle. The biggest of these problems is the setting up of the fatigue test on the complete airframe; therefore, this is covered more extensively with a discussion about how the test time can be shortened and with a description of the practical aspects of the test.

Ripley, E. L.↗

Interaction of High-cycle and Low-cycle Fatigue of Haynes 188 Alloy at 1400 F Deg

The interaction of low-cycle fatigue (LCF) and high-cycle fatigue (HCF) was evaluated at the NASA Lewis Research Center on Haynes 188 alloy at 1400 F. Completely reversed, axial-load, strain-controlled fatigue tests were performed to determine the baseline data for this study. Additional specimens for interaction tests were cycled first at a high strain range for various small portions of expected LCF life followed by a step change to a low strain range to failure in HCF. Failure was defined as complete specimen separation. The resultant lives varied between 10 and 5000 cycles for the low-cycle fatigue tests and between 4500 and 3 million for the high-cycle fatigue tests. For the interaction tests the low-cycle-life portion ranged from 30 and 1000 applied cycles while the high-frequency life ranged from 300 and 300,000 cycles to failure. The step change results showed a significant nonlinear interaction in expected life. Application of a small part of the LCF life drastically decreased the available HCF life as compared with what would have been expected by the classical linear damage rule (LDR).

Peter T Bizon↗

Performance of a quantitative study of instability-related delamination growth

An experimental program was conducted to quantify instability-induced imbedded delamination growth. Static tests on double cantilever beam (DCB) specimens yielded the critical mode 1 strain energy release rate (G sub 1 C) for T300/5208 graphite/epoxy. Static tests on mixed mode cracked lap shear (CLS) specimens, and a nonlinear finite element analysis (NFEA) of the CLS specimen to separate mode 1 and mode 2 effects, yielded the critical mode 2 strain energy release rate (G sub 2 C) for T300/5208. Constant amplitude fatigue tests on DCB and CLS specimens, along with the NFEA results on CLS specimens, quantified mode 1 and mode 2 contributions to delamination growth rate. Fatigue tests were conducted at a frequency (omega) of 10 Hertz, maintaining the minimum to maximum cyclic load ratio (R) at 0.05. Static compression and constant amplitude compression fatigue tests were also conducted on specimens with imbedded through the width (ITTW) delaminations. Kapton imbeddments were located below 3, 4 or 6 plies in a 64-ply laminate, during layup, to simulate ITTW delaminations.

Ramkumar, R. L.↗

High temperature, low-cycle fatigue of copper-base alloys for rocket nozzles. Part 2: Strainrange partitioning and low-cycle fatigue results at 538 deg C

Low-cycle fatigue tests of 1/2 Hard AMZIRC Copper and NARloy Z were performed in argon at 538 C to determine partitioned strain range versus life relationships. Strain-controlled low-cycle fatigue tests of a Zr-Cr-Mg copper-base alloy were also performed. Strain ranges, lower than those employed in previous tests, were imposed in order to extend the fatigue life curve out to approximately 400,000 cycles. An experimental copper alloy and an experimental silver alloy were also studied. Tensile tests were performed in air at room temperature and in argon at 538 C. Strain-controlled low-cycle fatigue tests were performed at 538 C in argon to define the fatigue life over the regime from 300 to 3,000 cycles. For the silver alloy, three additional heat treatments were introduced, and a limited evaluation of the short-term tensile and low-cycle fatigue behavior at 538 C was performed.

Conway, J. B.↗

Detecting gear tooth fracture in a high contact ratio face gear mesh

This paper summarized the results of a study in which three different vibration diagnostic methods were used to detect gear tooth fracture in a high contact ratio face gear mesh. The NASA spiral bevel gear fatigue test rig was used to produce unseeded fault, natural failures of four face gear specimens. During the fatigue tests, which were run to determine load capacity and primary failure mechanisms for face gears, vibration signals were monitored and recorded for gear diagnostic purposes. Gear tooth bending fatigue and surface pitting were the primary failure modes found in the tests. The damage ranged from partial tooth fracture on a single tooth in one test to heavy wear, severe pitting, and complete tooth fracture of several teeth on another test. Three gear fault detection techniques, FM4, NA4*, and NB4, were applied to the experimental data. These methods use the signal average in both the time and frequency domain. Method NA4* was able to conclusively detect the gear tooth fractures in three out of the four fatigue tests, along with gear tooth surface pitting and heavy wear. For multiple tooth fractures, all of the methods gave a clear indication of the damage. It was also found that due to the high contact ratio of the face gear mesh, single tooth fractures did not significantly affect the vibration signal, making this type of failure difficult to detect.

Zakrajsek, James J.↗

Simulation of Fatigue Crack Initiation at Corrosion Pits With EDM Notches

Uniaxial fatigue tests were conducted to compare the fatigue life of laboratory produced corrosion pits, similar to those observed in the shuttle main landing gear wheel bolt-hole, and an electro-discharged-machined (EDM) flaw. EDM Jaws are used to simulate corrosion pits during shuttle wheel (dynamometer) testing. The aluminum alloy, (AA 7050) laboratory fatigue tests were conducted to simulate the local stress level contained in the wheel bolt-hole. Under this high local stress condition, the EDM notch produced a fatigue life similar to test specimens containing corrosion pits of similar size. Based on the laboratory fatigue test results, the EDM Jaw (semi-circular disc shaped) produces a local stress state similar to corrosion pits and can be used to simulate a corrosion pit during the shuttle wheel dynamometer tests.

Smith, Stephen W.↗

Design of a Compact Fatigue Tester for Testing Irradiated Materials

A compact fatigue testing machine that can be easily inserted into a hot cell for characterization of irradiated materials is beneficial to help determine relative fatigue performance differences between new and irradiated material. Hot cell use has been carefully considered by limiting the size and weight of the machine, simplifying sample loading and test setup for operation via master-slave manipulator, and utilizing an efficient design to minimize maintenance. Funded from a US-Japan collaborative effort, the machine has been specifically designed to help characterize titanium material specimens. These specimens are flat cantilevered beams for initial studies, possibly utilizing samples irradiated at other sources of beam. The option to test spherically shaped samples cut from the T2K vacuum window is also available. The machine is able to test a sample to $10^7$ cycles in under a week, with options to count cycles and sense material failure. The design of this machine will be presented along with current status.

Hartsell, Brian↗

Employing sequential experiments to gain insights on the interaction between creep and fatigue damage in Ni‐base superalloys

Abstract The interaction between creep and fatigue damage in Ni‐base superalloy CMSX‐8 was explored using a sequential workflow that decouples creep and fatigue steps to quantify how accumulated creep damage interacts with subsequent isothermal low‐cycle fatigue (LCF) and vice versa. Two workflows were considered: creep followed by LCF and LCF followed by creep. For the first workflow, the subsequent LCF was evaluated at temperatures of 20°C, 750°C, and 1100°C. It was found that the extent of deleterious interaction of prior creep on LCF depended on increasing subsequent fatigue test temperature. For the LCF followed by creep, fatigue tests were first conducted at 20°C and 1100°C to 60% of life, and then creep was conducted at 800°C, where primary creep is promoted, or 900°C, where primary creep is absent. LCF damage accumulated at 1100°C accelerated creep and decreased ductility, while fatigue damage at room temperature had minimal effect on the creep behavior.

Gorgannejad, Sanam↗

Room Temperature and Elevated Temperature Composite Sandwich Joint Testing

Testing of composite sandwich joint elements has been completed to verify the strength capacity of joints designed to carry specified running loads representative of a high speed civil transport wing. Static tension testing at both room and an elevated temperature of 350 F and fatigue testing at room temperature were conducted to determine strength capacity, fatigue life, and failure modes. Static tension test results yielded failure loads above the design loads for the room temperature tests, confirming the ability of the joint concepts tested to carry their design loads. However, strength reductions as large as 30% were observed at the elevated test temperature, where all failure loads were below the room temperature design loads for the specific joint designs tested. Fatigue testing resulted in lower than predicted fatigue lives.

Walker, Sandra P.↗

Effects of Strain Gauge Coatings on Water Intrusion in Submerged Composite Coupon Testing

Marine energy structures are typically made using composite materials and are repeatedly loaded by currents and waves. Submersion and repeated loading lead to two environmental effects: moisture intrusion and mechanical fatigue. To understand their combined effects, submerged fatigue testing can be used. Submerged fatigue testing often requires submerged instrumentation to validate component manufacturing methods and models. Strain measurements are critical for understanding marine energy component loads. One common method for measuring strain is by using foil strain gauges, but the durability of strain gauges in submerged fatigue conditions is not well-understood. To increase strain gauge durability and protection from contamination, delamination, and water intrusion, strain gauge coatings may be applied over strain gauges and wire connections. In this study, strain gauges were adhered to composite coupons, coated, and mechanically tested in a water tank. Cycles to composite failure, cycles to strain gauge failure (SGF), strains, and SGF modes were used to measure the effects of strain gauge coatings on composite fatigue life and strain gauge durability. The coatings did not have significant effects on composite fatigue life or strain gauge durability. The methods developed and measurements taken at the coupon scale in this study will be used to inform methods and designs for subsequent submerged subcomponent testing, full-scale testing, and standards development. The benefits of designing marine energy structures to informed standards and designs are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.

composite materials↗

Low-cycle fatigue analysis of a cooled copper combustion chamber

A three-dimensional finite element elastoplastic strain analysis was performed for the throat section of regeneratively cooled rocket engine combustion chamber. The analysis included thermal and pressure loads, and the effects of temperature dependent material properties, to determine the strain range corresponding to the engine operating cycle. The strain range was used in conjunction with OFHC copper isothermal fatigue test data to predict engine low-cycle fatigue life. The analysis was performed for chamber configuration and operating conditions corresponding to a hydrogen-oxygen chamber which was fatigue tested to failure at the NASA Lewis Research Center.

Miller, R. W.↗

Integrating Oil Debris and Vibration Gear Damage Detection Technologies Using Fuzzy Logic

A diagnostic tool for detecting damage to spur gears was developed. Two different measurement technologies, wear debris analysis and vibration, were integrated into a health monitoring system for detecting surface fatigue pitting damage on gears. This integrated system showed improved detection and decision-making capabilities as compared to using individual measurement technologies. This diagnostic tool was developed and evaluated experimentally by collecting vibration and oil debris data from fatigue tests performed in the NASA Glenn Spur Gear Fatigue Test Rig. Experimental data were collected during experiments performed in this test rig with and without pitting. Results show combining the two measurement technologies improves the detection of pitting damage on spur gears.

Dempsey, Paula J.↗

Acoustic emission characteristics of copper alloys under low-cycle fatigue conditions

The acoustic emission (AE) characteristics of pure copper, zirconium-copper, and several copper alloys were determined to develop nondestructive evaluation schemes of thrust chambers through AE techniques. The AE counts rms voltages, frequency spectrum, and amplitude distribution analysis evaluated AE behavior under fatigue loading conditions. The results were interpreted with the evaluation of wave forms, crack propagation characteristics, as well as scanning electron fractographs of fatigue-tested samples. AE signals at the beginning of a fatigue test were produced by a sample of annealed alloys. A sample of zirconium-containing alloys annealed repeatedly after each fatigue loading cycle showed numerous surface cracks during the subsequent fatigue cycle, emitting strong-burst AE signals. Amplitude distribution analysis exhibits responses that are characteristic of certain types of AE signals.

Krampfner, Y.↗

Fatigue of continuous fiber reinforced metallic materials

The complex damage mechanisms that occur in fiber reinforced advanced metallic materials are discussed. As examples, results for several layups of SCS-6/Ti-15-3 composites are presented. Fatigue tests were conducted and analyzed for both notched and unnotched specimens at room and elevated temperatures. Test conditions included isothermal, non-isothermal, and simulated mission profile thermomechanical fatigue. Test results indicated that the stress in the 0 degree fibers is the controlling factor for fatigue life for a given test condition. An effective strain approach is presented for predicting crack initiation at notches. Fiber bridging models were applied to crack growth behavior.

Johnson, W. S.↗

Very High Cycle Fatigue of a Cast Aluminum Alloy: Size Effect and Crack Initiation

Fatigue properties of an Al-Si-Cu cast alloy were investigated with life up to very high cycle fatigue regime. Particular attention was given to specimen size effect and fatigue crack initiation mechanism. Uniaxial fatigue tests with constant amplitudes were carried out by using ultrasonic fatigue testing machine operating at 20 kHz, compared to the results obtained by using conventional hydraulic fatigue machine at 35 Hz. In order to evaluate the size effect, two sets of specimens with different dimensions were used. The results show that the fatigue strength of the studied alloy decreases with the increase in specimen size. Scanning electron microscopy observation of fracture surfaces revealed that most fatigue cracks initiated from microstructural defects such as porosity located on specimen surface or in subsurface. Weibull statistical analysis of fatigue data accounting for size effect was performed to predict the fatigue life of the Al-Si-Cu alloy in the very high cycle regime. Good agreement was found between the fatigue life prediction and the experimental data.

36 MATERIALS SCIENCE↗

A fatigue study of electrical discharge machine (EDM) strain-gage balance materials

A fatigue study was undertaken to determine how much electrical-discharge-machine (EDM) processing affected the fatigue life of balance materials: EDM and regular milling-machine (MM) samples were compared. Simulation of a typical balance stress configuration was devised for the fatigue testing in order to obtain results more closely related to balance situations. The fatigue testing of the EDM and MM specimens has indicated that the EDM technique does indeed reduce the fatigue life of 15-5PH steel, the first balance material tested. This conclusion was based on comparisons of the specimen fatigue lives with theoretical and manufacturer's data. Hence the EDM surface effects are detrimental to the fatigue life of this balance material.

Rhew, Ray D.↗